Skip to main content

Showing 1–4 of 4 results for author: Garty, G

.
  1. arXiv:2201.09778  [pdf

    physics.acc-ph physics.bio-ph physics.ins-det

    Traceable Dosimetry for MeV Ion Beams

    Authors: Guy Garty, Andrew D. Harken, David J. Brenner

    Abstract: Standard dosimetry protocols exist for highly penetrating photon and particle beams used in the clinic and in research. However, these protocols cannot be directly applied to shallow penetration MeV-range ion beams. The Radiological Research Accelerator Facility has been using such beams for almost 50 years to irradiate cell monolayers, using self-developed dosimetry, based on tissue equivalent io… ▽ More

    Submitted 24 January, 2022; originally announced January 2022.

    Comments: Submitted to Journal of Instrumentation

  2. VADER: a VAriable Dose-rate External 137Cs irradiatoR for internal emitter and low dose rate studies

    Authors: Guy Garty, Yan** Xu, Gary W. Johnson, Lubomir B. Smilenov, Simon K. Joseph, Monica Pujol-Canadell, Helen C. Turner, Shanaz A. Ghanhi, Qi Wang, Rompin Shih, Robort Morton, David Cuniberti, Shad R. Morton, Carlos Bueno-Beti, Thomas L. Morgan, Peter F. Caracappa, Evangelia C. Laiakis, Albert J. Fornace Jr., David J. Brenner

    Abstract: Beyond prompt irradiation, Cs-137 is likely to be the most biologically important agent released in many accidental (or malicious) radiation exposure scenarios. Cs-137 either can enter the food chain or be consumed or if present in the environment (e.g. fallout) can provide external irradiation. In either case, due to the high penetration of the 662 keV gamma rays emitted by Cs-137, the individual… ▽ More

    Submitted 28 May, 2019; v1 submitted 10 May, 2019; originally announced May 2019.

    Journal ref: Scientific Reports, 2020. 10(1), p. 19899

  3. arXiv:1904.07311  [pdf

    physics.med-ph physics.ins-det

    An injectable dosimeter for small animal irradiations

    Authors: Guy Garty, Monica C. Pujol, David J. Brenner

    Abstract: We have developed a novel in-vivo dosimeter based on glass encapsulated TLD rods. These encapsulated rods can be injected into mice and used for validating doses to an individual mouse in a protracted irradiation scenario where the mouse is free to move in an inhomogenous radiation field. Data from 30 irradiated mice shows a reliable dose reconstruction within 10% of the nominal delivered dose.

    Submitted 15 April, 2019; originally announced April 2019.

    Journal ref: Phys. Med. Biol. 64 (2019) 18NT01

  4. Map** the Sensitive Volume of an Ion-Counting Nanodosimeter

    Authors: Reinhard Schulte, Vladimir Bashkirov, Sergei Shchemelinin, Amos Breskin, Rachel Chechik, Guy Garty, Andrew Wroe, Bernd Grosswendt

    Abstract: We present two methods of independently map** the dimensions of the sensitive volume in an ion-counting nanodosimeter. The first method is based on a calculational approach simulating the extraction of ions from the sensitive volume, and the second method on probing the sensitive volume with 250 MeV protons. Sensitive-volume maps obtained with both methods are compared and systematic errors in… ▽ More

    Submitted 22 January, 2006; originally announced January 2006.

    Comments: 27 pages, 8 figures. Submitted to JINST, Jan. 16 2006