-
High Photon Upconversion Efficiency with Hybrid Triplet Sensitizers by Ultrafast Hole-Routing in Electronic-Doped Nanocrystals
Authors:
Alessandra Ronchi,
Chiara Capitani,
Graziella Gariano,
Valerio Pinchetti,
Matteo Luca Zaffalon,
Francesco Meinardi,
Sergio Brovelli1,
Angelo Monguzzi
Abstract:
Low power photon upconversion (UC) based on sensitized triplet-triplet annihilation (sTTA) is considered as the most promising upwards wavelength-shifting technique to enhance the light harvesting capability of solar devices by recovering the low-energy tail of the solar spectrum. Semiconductor nanocrystals (NCs) with conjugated organic ligands have been proposed as broadband sensitizers for exten…
▽ More
Low power photon upconversion (UC) based on sensitized triplet-triplet annihilation (sTTA) is considered as the most promising upwards wavelength-shifting technique to enhance the light harvesting capability of solar devices by recovering the low-energy tail of the solar spectrum. Semiconductor nanocrystals (NCs) with conjugated organic ligands have been proposed as broadband sensitizers for extending the light-harvesting capability of sTTA-UC molecular absorbers. Key to their functioning is efficient energy transfer (ET) from the NC to the triplet state of the ligands that sensitizes the triplet state of free emitters, whose annihilation generates the upconverted emission. To date, the triplet sensitization efficiency in such systems is limited by parasitic processes, such as charge transfer (typically of the photohole) to the organic ligand due to the disadvantageous band alignment of typical NCs and organic moieties. Available strategies only partially mitigate such losses and intrinsically limit the ET yield. Here we demonstrate a new exciton-manipulation approach that enables loss-free ET without detrimental side-effects. Specifically, we use CdSe NCs doped with gold atoms featuring a hole-accepting state in the NC bandgap at a higher energy than the HOMO level of the ligand 9-anthracene acid. Upon photoexcitation, the NC photoholes are routed to the Au-state faster than their transfer to the ligand, producing a long-lived bound exciton in perfect resonance with its triplet state. This hinders hole-transfer losses and results in ~100% efficient ET, over 50-fold higher than in standard NCs. By combining our hybrid sensitizers with an annihilator moiety, we achieved an sTTA-UC efficiency of ~12% (~24% in the normalized definition), which is the highest value for hybrid upconverters based on sTTA reported to date and approaches optimized organic systems.
△ Less
Submitted 21 April, 2020;
originally announced April 2020.
-
Calibration of the compact neutron spectrometer at PTB
Authors:
M. Osipenko,
V. Ceriale,
G. Gariano,
M. Girolami,
S. Cerchi,
R. Nolte,
E. Pirovano,
M. Ripani,
D. M. Trucchi
Abstract:
In the present article we describe the calibration measurements of the compact neutron spectrometer at certified PTB neutron source. The spectrometer is based on two diamond detectors enclosing the Li-6 neutron converter. The incident neutron energy is measured through the sum of energies of the two conversion reaction products: t and alpha. The prototype used in this work was based on two 4x4 mm2…
▽ More
In the present article we describe the calibration measurements of the compact neutron spectrometer at certified PTB neutron source. The spectrometer is based on two diamond detectors enclosing the Li-6 neutron converter. The incident neutron energy is measured through the sum of energies of the two conversion reaction products: t and alpha. The prototype used in this work was based on two 4x4 mm2, 100 um thick single crystal CVD commercial diamond plates. The measurements were performed in the fission spectrum domain at five different neutron energies varying from 0.3 up to 2 MeV. The obtained data showed a very good neutron energy reconstruction, i.e. in agreement with its reference values within statistical uncertainties or with deviation below 11 keV in absolute scale. The energy resolution of the spectrometer was found to be about 100 keV (RMS) with a small (about 9 keV/MeV) rising trend towards higher energies. The measured detection efficiency was found to be compatible with expectations based on analytical calculations and on Geant4 simulations within 3% statistical and 4% systematic precision.
△ Less
Submitted 15 October, 2018;
originally announced October 2018.
-
Production and Integration of the ATLAS Insertable B-Layer
Authors:
B. Abbott,
J. Albert,
F. Alberti,
M. Alex,
G. Alimonti,
S. Alkire,
P. Allport,
S. Altenheiner,
L. Ancu,
E. Anderssen,
A. Andreani,
A. Andreazza,
B. Axen,
J. Arguin,
M. Backhaus,
G. Balbi,
J. Ballansat,
M. Barbero,
G. Barbier,
A. Bassalat,
R. Bates,
P. Baudin,
M. Battaglia,
T. Beau,
R. Beccherle
, et al. (352 additional authors not shown)
Abstract:
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and i…
▽ More
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and integrated luminosities realised following the shutdown. Because of the extreme radiation and collision rate environment, several new radiation-tolerant sensor and electronic technologies were utilised for this layer. This paper reports on the IBL construction and integration prior to its operation in the ATLAS detector.
△ Less
Submitted 6 June, 2018; v1 submitted 2 March, 2018;
originally announced March 2018.
-
Upgrade of compact neutron spectrometer for high flux environments
Authors:
M. Osipenko,
A. Bellucci,
V. Ceriale,
D. Corsini,
G. Gariano,
F. Gatti,
M. Girolami,
S. Minutoli,
F. Panza,
M. Pillon,
M. Ripani,
D. M. Trucchi
Abstract:
In this paper a new version of Li6-based neutron spectrometer for high flux environments is described. The new spectrometer was built with commercial single crystal Chemical Vapour Deposition diamonds of electronic grade. These crystals feature better charge collection as well as higher radiation hardness. Ohmic metal contacts were deposited on the diamonds suppressing build-up of space charge obs…
▽ More
In this paper a new version of Li6-based neutron spectrometer for high flux environments is described. The new spectrometer was built with commercial single crystal Chemical Vapour Deposition diamonds of electronic grade. These crystals feature better charge collection as well as higher radiation hardness. Ohmic metal contacts were deposited on the diamonds suppressing build-up of space charge observed in the previous prototypes. New passive preamplification of signal at detector side was implemented to improve the resolution. This preamplification is based on RF transformer not sensitive to high neutron flux. Compact mechanical design allowed to reduce detector size to a tube of 1 cm diameter and 13 cm long. The spectrometer was tested in thermal column of TRIGA reactor and at DD neutron generator. The test results indicate an energy resolution of 72 keV (RMS) and coincidence timing resolution of 68 ps (RMS). The measured data are in agreement with Geant4 simulations except for larger energy loss tail presumably related to imperfections of metal contacts and glue expansion.
△ Less
Submitted 18 July, 2017;
originally announced July 2017.
-
Test Beam Results of 3D Silicon Pixel Sensors for the ATLAS upgrade
Authors:
ATLAS 3D Collaboration,
P. Grenier,
G. Alimonti,
M. Barbero,
R. Bates,
E. Bolle,
M. Borri,
M. Boscardin,
C. Buttar,
M. Capua,
M. Cavalli-Sforza,
M. Cobal,
A. Cristofoli,
G-F. Dalla Betta,
G. Darbo,
C. Da ViĆ ,
E. Devetak,
B. DeWilde,
B. Di Girolamo,
D. Dobos,
K. Einsweiler,
D. Esseni,
S. Fazio,
C. Fleta,
J. Freestone
, et al. (68 additional authors not shown)
Abstract:
Results on beam tests of 3D silicon pixel sensors aimed at the ATLAS Insertable-B-Layer and High Luminosity LHC (HL-LHC)) upgrades are presented. Measurements include charge collection, tracking efficiency and charge sharing between pixel cells, as a function of track incident angle, and were performed with and without a 1.6 T magnetic field oriented as the ATLAS Inner Detector solenoid field. Sen…
▽ More
Results on beam tests of 3D silicon pixel sensors aimed at the ATLAS Insertable-B-Layer and High Luminosity LHC (HL-LHC)) upgrades are presented. Measurements include charge collection, tracking efficiency and charge sharing between pixel cells, as a function of track incident angle, and were performed with and without a 1.6 T magnetic field oriented as the ATLAS Inner Detector solenoid field. Sensors were bump bonded to the front-end chip currently used in the ATLAS pixel detector. Full 3D sensors, with electrodes penetrating through the entire wafer thickness and active edge, and double-sided 3D sensors with partially overlap** bias and read-out electrodes were tested and showed comparable performance.
△ Less
Submitted 21 January, 2011;
originally announced January 2011.