-
Developments and applications of the OPTIMADE API for materials discovery, design, and data exchange
Authors:
Matthew L. Evans,
Johan Bergsma,
Andrius Merkys,
Casper W. Andersen,
Oskar B. Andersson,
Daniel Beltrán,
Evgeny Blokhin,
Tara M. Boland,
Rubén Castañeda Balderas,
Kamal Choudhary,
Alberto Díaz Díaz,
Rodrigo Domínguez García,
Hagen Eckert,
Kristjan Eimre,
María Elena Fuentes Montero,
Adam M. Krajewski,
Jens Jørgen Mortensen,
José Manuel Nápoles Duarte,
Jacob Pietryga,
Ji Qi,
Felipe de Jesús Trejo Carrillo,
Antanas Vaitkus,
Jusong Yu,
Adam Zettel,
Pedro Baptista de Castro
, et al. (34 additional authors not shown)
Abstract:
The Open Databases Integration for Materials Design (OPTIMADE) application programming interface (API) empowers users with holistic access to a growing federation of databases, enhancing the accessibility and discoverability of materials and chemical data. Since the first release of the OPTIMADE specification (v1.0), the API has undergone significant development, leading to the upcoming v1.2 relea…
▽ More
The Open Databases Integration for Materials Design (OPTIMADE) application programming interface (API) empowers users with holistic access to a growing federation of databases, enhancing the accessibility and discoverability of materials and chemical data. Since the first release of the OPTIMADE specification (v1.0), the API has undergone significant development, leading to the upcoming v1.2 release, and has underpinned multiple scientific studies. In this work, we highlight the latest features of the API format, accompanying software tools, and provide an update on the implementation of OPTIMADE in contributing materials databases. We end by providing several use cases that demonstrate the utility of the OPTIMADE API in materials research that continue to drive its ongoing development.
△ Less
Submitted 5 April, 2024; v1 submitted 1 February, 2024;
originally announced February 2024.
-
The human factor: results of a small-angle scattering data analysis Round Robin
Authors:
Brian R. Pauw,
Glen J. Smales,
Andy S. Anker,
Daniel M. Balazs,
Frederick L. Beyer,
Ralf Bienert,
Wim G. Bouwman,
Ingo Breßler,
Joachim Breternitz,
Erik S Brok,
Gary Bryant,
Andrew J. Clulow,
Erin R. Crater,
Frédéric De Geuser,
Alessandra Del Giudice,
Jérôme Deumer,
Sabrina Disch,
Shankar Dutt,
Kilian Frank,
Emiliano Fratini,
Elliot P. Gilbert,
Marc Benjamin Hahn,
James Hallett,
Max Hohenschutz,
Martin Hollamby
, et al. (24 additional authors not shown)
Abstract:
A Round Robin study has been carried out to estimate the impact of the human element in small-angle scattering data analysis. Four corrected datasets were provided to participants ready for analysis. All datasets were measured on samples containing spherical scatterers, with two datasets in dilute dispersions, and two from powders. Most of the 46 participants correctly identified the number of pop…
▽ More
A Round Robin study has been carried out to estimate the impact of the human element in small-angle scattering data analysis. Four corrected datasets were provided to participants ready for analysis. All datasets were measured on samples containing spherical scatterers, with two datasets in dilute dispersions, and two from powders. Most of the 46 participants correctly identified the number of populations in the dilute dispersions, with half of the population mean entries within 1.5% and half of the population width entries within 40%, respectively. Due to the added complexity of the structure factor, much fewer people submitted answers on the powder datasets. For those that did, half of the entries for the means and widths were within 44% and 86% respectively. This Round Robin experiment highlights several causes for the discrepancies, for which solutions are proposed.
△ Less
Submitted 7 March, 2023;
originally announced March 2023.
-
A Blockchain-based Data Governance Framework with Privacy Protection and Provenance for e-Prescription
Authors:
Rodrigo Dutra Garcia,
Gowri Sankar Ramachandran,
Raja Jurdak,
Jo Ueyama
Abstract:
Real-world applications in healthcare and supply chain domains produce, exchange, and share data in a multi-stakeholder environment. Data owners want to control their data and privacy in such settings. On the other hand, data consumers demand methods to understand when, how, and who produced the data. These requirements necessitate data governance frameworks that guarantee data provenance, privacy…
▽ More
Real-world applications in healthcare and supply chain domains produce, exchange, and share data in a multi-stakeholder environment. Data owners want to control their data and privacy in such settings. On the other hand, data consumers demand methods to understand when, how, and who produced the data. These requirements necessitate data governance frameworks that guarantee data provenance, privacy protection, and consent management. We introduce a decentralized data governance framework based on blockchain technology and proxy re-encryption to let data owners control and track their data through privacy-enhancing and consent management mechanisms. Besides, our framework allows the data consumers to understand data lineage through a blockchain-based provenance mechanism. We have used Digital e-prescription as the use case since it has multiple stakeholders and sensitive data while enabling the medical fraternity to manage patients' prescription data, involving patients as data owners, doctors and pharmacists as data consumers. Our proof-of-concept implementation and evaluation results based on CosmWasm, Ethereum, and pyUmbral PRE show that the proposed decentralized system guarantees transparency, privacy, and trust with minimal overhead.
△ Less
Submitted 27 December, 2021;
originally announced December 2021.
-
Noise Reduction to Compute Tissue Mineral Density and Trabecular Bone Volume Fraction from Low Resolution QCT
Authors:
Felix Thomsen,
José M. Fuertes García,
Manuel Lucena,
Juan Pisula,
Rodrigo de Luis García,
Jan Broggrefe,
Claudio Delrieux
Abstract:
We propose a 3D neural network with specific loss functions for quantitative computed tomography (QCT) noise reduction to compute micro-structural parameters such as tissue mineral density (TMD) and bone volume ratio (BV/TV) with significantly higher accuracy than using no or standard noise reduction filters. The vertebra-phantom study contained high resolution peripheral and clinical CT scans wit…
▽ More
We propose a 3D neural network with specific loss functions for quantitative computed tomography (QCT) noise reduction to compute micro-structural parameters such as tissue mineral density (TMD) and bone volume ratio (BV/TV) with significantly higher accuracy than using no or standard noise reduction filters. The vertebra-phantom study contained high resolution peripheral and clinical CT scans with simulated in vivo CT noise and nine repetitions of three different tube currents (100, 250 and 360 mAs). Five-fold cross validation was performed on 20466 purely spongy pairs of noisy and ground-truth patches. Comparison of training and test errors revealed high robustness against over-fitting. While not showing effects for the assessment of BMD and voxel-wise densities, the filter improved thoroughly the computation of TMD and BV/TV with respect to the unfiltered data. Root-mean-square and accuracy errors of low resolution TMD and BV/TV decreased to less than 17% of the initial values. Furthermore filtered low resolution scans revealed still more TMD- and BV/TV-relevant information than high resolution CT scans, either unfiltered or filtered with two state-of-the-art standard denoising methods. The proposed architecture is threshold and rotational invariant, applicable on a wide range of image resolutions at once, and likely serves for an accurate computation of further micro-structural parameters. Furthermore, it is less prone for over-fitting than neural networks that compute structural parameters directly. In conclusion, the method is potentially important for the diagnosis of osteoporosis and other bone diseases since it allows to assess relevant 3D micro-structural information from standard low exposure CT protocols such as 100 mAs and 120 kVp.
△ Less
Submitted 4 November, 2020;
originally announced November 2020.