Deep Learning for fully automatic detection, segmentation, and Gleason Grade estimation of prostate cancer in multiparametric Magnetic Resonance Images
Authors:
Oscar J. Pellicer-Valero,
José L. Marenco Jiménez,
Victor Gonzalez-Perez,
Juan Luis Casanova Ramón-Borja,
Isabel Martín García,
María Barrios Benito,
Paula Pelechano Gómez,
José Rubio-Briones,
María José Rupérez,
José D. Martín-Guerrero
Abstract:
The emergence of multi-parametric magnetic resonance imaging (mpMRI) has had a profound impact on the diagnosis of prostate cancers (PCa), which is the most prevalent malignancy in males in the western world, enabling a better selection of patients for confirmation biopsy. However, analyzing these images is complex even for experts, hence opening an opportunity for computer-aided diagnosis systems…
▽ More
The emergence of multi-parametric magnetic resonance imaging (mpMRI) has had a profound impact on the diagnosis of prostate cancers (PCa), which is the most prevalent malignancy in males in the western world, enabling a better selection of patients for confirmation biopsy. However, analyzing these images is complex even for experts, hence opening an opportunity for computer-aided diagnosis systems to seize. This paper proposes a fully automatic system based on Deep Learning that takes a prostate mpMRI from a PCa-suspect patient and, by leveraging the Retina U-Net detection framework, locates PCa lesions, segments them, and predicts their most likely Gleason grade group (GGG). It uses 490 mpMRIs for training/validation, and 75 patients for testing from two different datasets: ProstateX and IVO (Valencia Oncology Institute Foundation). In the test set, it achieves an excellent lesion-level AUC/sensitivity/specificity for the GGG$\geq$2 significance criterion of 0.96/1.00/0.79 for the ProstateX dataset, and 0.95/1.00/0.80 for the IVO dataset. Evaluated at a patient level, the results are 0.87/1.00/0.375 in ProstateX, and 0.91/1.00/0.762 in IVO. Furthermore, on the online ProstateX grand challenge, the model obtained an AUC of 0.85 (0.87 when trained only on the ProstateX data, tying up with the original winner of the challenge). For expert comparison, IVO radiologist's PI-RADS 4 sensitivity/specificity were 0.88/0.56 at a lesion level, and 0.85/0.58 at a patient level. Additional subsystems for automatic prostate zonal segmentation and mpMRI non-rigid sequence registration were also employed to produce the final fully automated system. The code for the ProstateX-trained system has been made openly available at https://github.com/OscarPellicer/prostate_lesion_detection. We hope that this will represent a landmark for future research to use, compare and improve upon.
△ Less
Submitted 2 February, 2022; v1 submitted 23 March, 2021;
originally announced March 2021.
Computational hemodynamics in arteries with the one-dimensional augmented fluid-structure interaction system: viscoelastic parameters estimation and comparison with in-vivo data
Authors:
Giulia Bertaglia,
Adrián Navas-Montilla,
Alessandro Valiani,
Manuel Ignacio Monge García,
Javier Murillo,
Valerio Caleffi
Abstract:
Mathematical models are widely recognized as a valuable tool for cardiovascular diagnosis and the study of circulatory diseases, especially to obtain data that require otherwise invasive measurements. To correctly simulate body hemodynamics, the viscoelastic properties of vessel walls are a key aspect to be taken into account as they play an essential role in cardiovascular behavior. The present w…
▽ More
Mathematical models are widely recognized as a valuable tool for cardiovascular diagnosis and the study of circulatory diseases, especially to obtain data that require otherwise invasive measurements. To correctly simulate body hemodynamics, the viscoelastic properties of vessel walls are a key aspect to be taken into account as they play an essential role in cardiovascular behavior. The present work aims to apply the augmented fluid-structure interaction system of blood flow to real case studies to assess the validity of the model as a valuable resource to improve cardiovascular diagnostics and the treatment of pathologies. First, the ability of the model to correctly simulate pulse waveforms in single arterial segments is verified using literature benchmark test cases. Such cases are designed taking into account a simple elastic behavior of the wall in the upper thoracic aorta and in the common carotid artery. Furthermore, in-vivo pressure waveforms, extracted from tonometric measurements performed on four human common carotid arteries and two common femoral arteries, are compared to numerical solutions. It is highlighted that the viscoelastic dam** effect of arterial walls is required to avoid an overestimation of pressure peaks. An effective procedure to estimate the viscoelastic parameters of the model is herein proposed, which returns hysteresis curves of the common carotid arteries dissipating energy fractions in line with values calculated from literature hysteresis loops in the same vessel.
△ Less
Submitted 6 December, 2019;
originally announced December 2019.