Cosmic Background Neutrinos Deflected by Gravity: DEMNUni Simulation Analysis
Authors:
Beatriz Hernández-Molinero,
Carmelita Carbone,
Raul Jimenez,
Carlos Peña Garay
Abstract:
The local supercluster acts as a gravity deflection source for cosmic background neutrinos. This deflection by gravity changes the neutrino helicity and therefore has important consequences for ground based tritium capture experiments aimed at determining if the neutrino is Dirac or Majorana. Here we explore the deflection effect of the local supercluster using the higher resolution DEMNUni simula…
▽ More
The local supercluster acts as a gravity deflection source for cosmic background neutrinos. This deflection by gravity changes the neutrino helicity and therefore has important consequences for ground based tritium capture experiments aimed at determining if the neutrino is Dirac or Majorana. Here we explore the deflection effect of the local supercluster using the higher resolution DEMNUni simulation suite and reaffirm our previous results. We show that the lightest neutrinos are ultra-relativistic enough to suffer little deflection by gravity and at the same time not relativistic enough to achieve the same capture rate for Dirac and Majorana cases. This means that the capture rate in Ptolemy-like experiments will be sensitive to the neutrino nature and that gravity deflection enlarges the difference between Majorana and Dirac rates. Moreover, using the relation between mass and momentum of the neutrinos frozen Fermi-Dirac distribution, we are able to calculate the deflection angle for different neutrino masses from the same set of neutrinos obtained from the simulation. Doing so, we provide a formula to compute the deflection angle for any neutrino mass, such that when cosmology detects an absolute neutrino mass, precise predictions can be made for tritium ground-based detectors on Earth aimed to determine neutrinos nature.
△ Less
Submitted 29 January, 2023;
originally announced January 2023.
-
The Canfranc Axion Detection Experiment (CADEx): Search for axions at 90 GHz with Kinetic Inductance Detectors
Authors:
Beatriz Aja,
Sergio Arguedas Cuendis,
Ivan Arregui,
Eduardo Artal,
R. Belén Barreiro,
Francisco J. Casas,
Maria C. de Ory,
Alejandro Díaz-Morcillo,
Luisa de la Fuente,
Juan Daniel Gallego,
José María García-Barceló,
Benito Gimeno,
Alicia Gomez,
Daniel Granados,
Bradley J. Kavanagh,
Miguel A. G. Laso,
Txema Lopetegi,
Antonio José Lozano-Guerrero,
Maria T. Magaz,
Jesús Martín-Pintado,
Enrique Martínez-González,
Jordi Miralda-Escudé,
Juan Monzó-Cabrera,
Jose R. Navarro-Madrid,
Ana B. Nuñez Chico
, et al. (11 additional authors not shown)
Abstract:
We propose a novel experiment, the Canfranc Axion Detection Experiment (CADEx), to probe dark matter axions with masses in the range 330-460 $μ$eV, within the W-band (80-110 GHz), an unexplored parameter space in the well-motivated dark matter window of Quantum ChromoDynamics (QCD) axions. The experimental design consists of a microwave resonant cavity haloscope in a high static magnetic field cou…
▽ More
We propose a novel experiment, the Canfranc Axion Detection Experiment (CADEx), to probe dark matter axions with masses in the range 330-460 $μ$eV, within the W-band (80-110 GHz), an unexplored parameter space in the well-motivated dark matter window of Quantum ChromoDynamics (QCD) axions. The experimental design consists of a microwave resonant cavity haloscope in a high static magnetic field coupled to a highly sensitive detecting system based on Kinetic Inductance Detectors via optimized quasi-optics (horns and mirrors). The experiment is in preparation and will be installed in the dilution refrigerator of the Canfranc Underground Laboratory. Sensitivity forecasts for axion detection with CADEx, together with the potential of the experiment to search for dark photons, are presented.
△ Less
Submitted 6 June, 2022;
originally announced June 2022.
-
Snowmass 2021 White Paper: The Selena Neutrino Experiment
Authors:
A. E. Chavarria,
C. Galbiati,
B. Hernandez-Molinero,
Al. Ianni,
X. Li,
Y. Mei,
D. Montanino,
X. Ni,
C. Peña Garay,
A. Piers,
H. Wang
Abstract:
Imaging devices made from an ionization target layer of amorphous selenium (aSe) coupled to a silicon complementary metal-oxide-semiconductor (CMOS) active pixel array for charge readout are a promising technology for neutrino physics. The high spatial resolution in a solid-state target provides unparalleled rejection of backgrounds from natural radioactivity in the search for neutrinoless $ββ$ de…
▽ More
Imaging devices made from an ionization target layer of amorphous selenium (aSe) coupled to a silicon complementary metal-oxide-semiconductor (CMOS) active pixel array for charge readout are a promising technology for neutrino physics. The high spatial resolution in a solid-state target provides unparalleled rejection of backgrounds from natural radioactivity in the search for neutrinoless $ββ$ decay and for electron neutrino ($ν_e$) spectroscopy with $^{82}$Se. In this white paper, we summarize the broad scientific program of a large imaging detector with a 10-ton target of $^{82}$Se. We review the detector technology, and outline the ongoing research program to realize this experiment.
△ Less
Submitted 16 March, 2022;
originally announced March 2022.
-
Design of new resonant haloscopes in the search for the darkmatter axion: a review of the first steps in the RADES collaboration
Authors:
A. Díaz-Morcillo,
J. M. García Barceló,
A. J. Lozano-Guerrero,
P. Navarro,
B. Gimeno,
S. Arguedas Cuendis,
A. Álvarez Melcón,
C. Cogollos,
S. Calatroni,
B. Döbrich,
J. D. Gallego,
J. Golm,
I. G. Irastorza,
C. Malbrunot,
Jordi Miralda-Escudé,
C. Peña Garay,
J. Redondo,
W. Wuensch
Abstract:
Within the increasing interest in the dark matter axion detection through haloscopes, in which different international groups are currently involved, the RADES group was established in 2016 with the goal of develo** very sensitive detection systems to be operated in dipole magnets. This review deals with the work developed by this collaboration during its first five years, from the first designs…
▽ More
Within the increasing interest in the dark matter axion detection through haloscopes, in which different international groups are currently involved, the RADES group was established in 2016 with the goal of develo** very sensitive detection systems to be operated in dipole magnets. This review deals with the work developed by this collaboration during its first five years, from the first designs, based on the multi-cavity concept, aiming to increase the haloscope volume and, so, to improve its sensitivity, their evolution, the data acquisition design, and, finally, the first experimental run. Moreover, the envisaged work within RADES, for both dipole and solenoid magnets, in the short and medium term is also presented.
△ Less
Submitted 22 January, 2022; v1 submitted 29 November, 2021;
originally announced November 2021.
-
Wide-band full-wave electromagnetic modal analysis of the coupling between dark-matter axions and photons in microwave resonators
Authors:
P. Navarro,
Benito Gimeno,
A. Alvarez Melcon,
S. Arguedas Cuendis,
C. Cogollos,
A. Diaz-Morcillo,
J. D. Gallego,
J. M. Garcia Barcelo,
J. Golm,
I. G. Irastorza,
A. J. Lozano Guerrero,
C. Penya Garay
Abstract:
The electromagnetic coupling axion-photon in a microwave cavity is revisited with the Boundary Integral - Resonant Mode Expansion (BI-RME) 3D technique. Such full-wave modal technique has been applied for the rigorous analysis of the excitation of a microwave cavity with an axion field. In this scenario, the electromagnetic field generated by the axion-photon coupling can be assumed to be driven b…
▽ More
The electromagnetic coupling axion-photon in a microwave cavity is revisited with the Boundary Integral - Resonant Mode Expansion (BI-RME) 3D technique. Such full-wave modal technique has been applied for the rigorous analysis of the excitation of a microwave cavity with an axion field. In this scenario, the electromagnetic field generated by the axion-photon coupling can be assumed to be driven by equivalent electrical charge and current densities. These densities have been inserted in the general BI-RME 3D equations, which express the RF electromagnetic field existing within a cavity as an integral involving the Dyadic Green functions of the cavity (under Coulomb gauge) as well as such densities. This method is able to take into account any arbitrary spatial and temporal variation of both magnitude and phase of the axion field. Next, we have obtained a simple network driven by the axion current source, which represents the coupling between the axion field and the resonant modes of the cavity. With this approach, it is possible to calculate the extracted and dissipated RF power as a function of frequency along a broad band and without Cauchy-Lorentz approximations, obtaining the spectrum of the electromagnetic field generated in the cavity, and dealing with modes relatively close to the axion resonant mode. Moreover, with this technique we have a complete knowledge of the signal extracted from the cavity, not only in magnitude but also in phase. This can be an interesting issue for future analysis where the axion phase is an important parameter.
△ Less
Submitted 11 April, 2022; v1 submitted 7 July, 2021;
originally announced July 2021.
-
First results of the CAST-RADES haloscope search for axions at 34.67 $μ$eV
Authors:
A. Álvarez Melcón,
S. Arguedas Cuendis,
J. Baier,
K. Barth,
H. Bräuniger,
S. Calatroni,
G. Cantatore,
F. Caspers,
J. F Castel,
S. A. Cetin,
C. Cogollos,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
A. Díaz-Morcillo,
B. Döbrich,
H. Fischer,
W. Funk,
J. D Gallego,
J. M García Barceló,
A. Gardikiotis,
J. Garza,
B. Gimeno,
S. Gninenko
, et al. (34 additional authors not shown)
Abstract:
We present results of the Relic Axion Dark-Matter Exploratory Setup (RADES), a detector which is part of the CERN Axion Solar Telescope (CAST), searching for axion dark matter in the 34.67$μ$eV mass range. A radio frequency cavity consisting of 5 sub-cavities coupled by inductive irises took physics data inside the CAST dipole magnet for the first time using this filter-like haloscope geometry. An…
▽ More
We present results of the Relic Axion Dark-Matter Exploratory Setup (RADES), a detector which is part of the CERN Axion Solar Telescope (CAST), searching for axion dark matter in the 34.67$μ$eV mass range. A radio frequency cavity consisting of 5 sub-cavities coupled by inductive irises took physics data inside the CAST dipole magnet for the first time using this filter-like haloscope geometry. An exclusion limit with a 95% credibility level on the axion-photon coupling constant of g$_{aγ}\gtrsim 4\times10^{-13} \text{GeV}^{-1}$ over a mass range of 34.6738 $μ$eV < $m_a$ < 34.6771 $μ$eV is set. This constitutes a significant improvement over the current strongest limit set by CAST at this mass and is at the same time one of the most sensitive direct searches for an axion dark matter candidate above the mass of 25 $μ$eV. The results also demonstrate the feasibility of exploring a wider mass range around the value probed by CAST-RADES in this work using similar coherent resonant cavities.
△ Less
Submitted 27 October, 2021; v1 submitted 28 April, 2021;
originally announced April 2021.
-
Scalable haloscopes for axion dark matter detection in the 30$μ$eV range with RADES
Authors:
A. Álvarez Melcón,
S. Arguedas Cuendis,
C. Cogollos,
A. Díaz-Morcillo,
B. Döbrich,
J. D. Gallego,
J. M. García Barceló,
B. Gimeno,
J. Golm,
I. G. Irastorza,
A. J. Lozano-Guerrero,
C. Malbrunot,
A. Millar,
P. Navarro,
C. Peña Garay,
J. Redondo,
W. Wuensch
Abstract:
RADES (Relic Axion Detector Exploratory Setup) is a project with the goal of directly searching for axion dark matter above the $30 μ$eV scale employing custom-made microwave filters in magnetic dipole fields. Currently RADES is taking data at the LHC dipole of the CAST experiment. In the long term, the RADES cavities are envisioned to take data in the (baby)-IAXO magnet. In this article we report…
▽ More
RADES (Relic Axion Detector Exploratory Setup) is a project with the goal of directly searching for axion dark matter above the $30 μ$eV scale employing custom-made microwave filters in magnetic dipole fields. Currently RADES is taking data at the LHC dipole of the CAST experiment. In the long term, the RADES cavities are envisioned to take data in the (baby)-IAXO magnet. In this article we report on the modelling, building and characterisation of an optimised microwave-filter design with alternating irises that exploits maximal coupling to axions while being scalable in length without suffering from mode-mixing. We develop the mathematical formalism and theoretical study which justifies the performance of the chosen design. We also point towards the applicability of this formalism to optimise the MADMAX dielectric haloscopes.
△ Less
Submitted 22 June, 2020; v1 submitted 18 February, 2020;
originally announced February 2020.
-
The 3 cavity prototypes of RADES, an axion detector using microwave filters at CAST
Authors:
S. Arguedas Cuendis,
A. Álvarez Melcón,
C. Cogollos,
A. Díaz-Morcillo,
B. Döbrich,
J. D. Gallego,
B. Gimeno,
I. G. Irastorza,
A. J. Lozano-Guerrero,
C. Malbrunot,
P. Navarro,
C. Peña Garay,
J. Redondo,
T. Vafeiadis,
W. Wuensch
Abstract:
The Relic Axion Detector Experimental Setup (RADES) is an axion search project that uses a microwave filter as resonator for Dark Matter conversion. The main focus of this publication is the description of the 3 different cavity prototypes of RADES. The result of the first tests of one of the prototypes is also presented. The filters consist of 5 or 6 stainless steel sub-cavities joined by rectang…
▽ More
The Relic Axion Detector Experimental Setup (RADES) is an axion search project that uses a microwave filter as resonator for Dark Matter conversion. The main focus of this publication is the description of the 3 different cavity prototypes of RADES. The result of the first tests of one of the prototypes is also presented. The filters consist of 5 or 6 stainless steel sub-cavities joined by rectangular irises. The size of the sub-cavities determines the working frequency, the amount of sub-cavities determine the working volume. The first cavity prototype was built in 2017 to work at a frequency of $\sim$ 8.4 GHz and it was placed at the 9 T CAST dipole magnet at CERN. Two more prototypes were designed and built in 2018. The aim of the new designs is to find and test the best cavity geometry in order to scale up in volume and to introduce an effective tuning mechanism. Our results demonstrate the promising potential of this type of filter to reach QCD axion sensitivity at X-Band frequencies.
△ Less
Submitted 11 March, 2019;
originally announced March 2019.
-
Cosmic-ray muon flux at Canfranc Underground Laboratory
Authors:
Wladyslaw Henryk Trzaska,
Maciej Slupecki,
Iulian Bandac,
Alberto Bayo,
Alessandro Bettini,
Leonid Bezrukov,
Timo Enqvist,
Almaz Fazliakhmetov,
Aldo Ianni,
Lev Inzhechik,
Jari Joutsenvaara,
Pasi Kuusiniemi,
Kai Loo,
Bayarto Lubsandorzhiev,
Alexander Nozik,
Carlos Peña Garay,
Maria Poliakova
Abstract:
Residual flux and angular distribution of high-energy cosmic muons have been measured in two underground locations at the Canfranc Underground Laboratory (LSC) using a dedicated Muon Monitor. The instrument consists of three layers of fast scintillation detector modules operating as 352 independent pixels. The monitor has flux-defining area of 1 m${}^{2}$, covers all azimuth angles, and zenith ang…
▽ More
Residual flux and angular distribution of high-energy cosmic muons have been measured in two underground locations at the Canfranc Underground Laboratory (LSC) using a dedicated Muon Monitor. The instrument consists of three layers of fast scintillation detector modules operating as 352 independent pixels. The monitor has flux-defining area of 1 m${}^{2}$, covers all azimuth angles, and zenith angles up to $80^\circ$. The measured integrated muon flux is $(5.26 \pm 0.21) \times 10^{-3}$ m${}^{-2}$s${}^{-1}$ in the Hall A of the LAB2400 and $(4.29 \pm 0.17) \times 10^{-3}$ m${}^{-2}$s${}^{-1}$ in LAB2500. The angular dependence is consistent with the known profile and rock density of the surrounding mountains. In particular, there is a clear maximum in the flux coming from the direction of the Rioseta valley.
△ Less
Submitted 18 July, 2019; v1 submitted 3 February, 2019;
originally announced February 2019.
-
Looking for Axion Dark Matter in Dwarf Spheroidals
Authors:
Andrea Caputo,
Carlos Peña Garay,
Samuel J. Witte
Abstract:
We study the extent to which the decay of cold dark matter axions can be probed with forthcoming radio telescopes such as the Square Kilometer Array (SKA). In particular we focus on signals arising from dwarf spheroidal galaxies, where astrophysical uncertainties are reduced and the expected magnetic field strengths are such that signals arising from axion decay may dominate over axion-photon conv…
▽ More
We study the extent to which the decay of cold dark matter axions can be probed with forthcoming radio telescopes such as the Square Kilometer Array (SKA). In particular we focus on signals arising from dwarf spheroidal galaxies, where astrophysical uncertainties are reduced and the expected magnetic field strengths are such that signals arising from axion decay may dominate over axion-photon conversion in a magnetic field. We show that with $\sim100$ hours of observing time, SKA could improve current sensitivity by a factor of about five.
△ Less
Submitted 14 March, 2019; v1 submitted 22 May, 2018;
originally announced May 2018.
-
Axion Searches with Microwave Filters: the RADES project
Authors:
Alejandro Álvarez Melcón,
Sergio Arguedas Cuendis,
Cristian Cogollos,
Alejandro Díaz-Morcillo,
Babette Döbrich,
Juan Daniel Gallego,
Benito Gimeno,
Igor G. Irastorza,
Antonio José Lozano-Guerrero,
Chloé Malbrunot,
Pablo Navarro,
Carlos Peña Garay,
Javier Redondo,
Theodoros Vafeiadis,
Walter Wuensch
Abstract:
We propose, design and construct a variant of the conventional axion haloscope concept that could be competitive in the search for dark matter axions of masses in the decade 10-100 $μ$eV. Theses masses are located somewhat above the mass range in which existing experiments have reached sensitivity to benchmark QCD axion models. Our haloscope consists of an array of small microwave cavities connect…
▽ More
We propose, design and construct a variant of the conventional axion haloscope concept that could be competitive in the search for dark matter axions of masses in the decade 10-100 $μ$eV. Theses masses are located somewhat above the mass range in which existing experiments have reached sensitivity to benchmark QCD axion models. Our haloscope consists of an array of small microwave cavities connected by rectangular irises, in an arrangement commonly used in radio-frequency filters. The size of the unit cavity determines the main resonant frequency, while the possibility to connect a {large} number of cavities allows to reach large detection volumes. We develop the theoretical framework of the detection concept, and present design prescriptions to optimize detection capabilities. We describe the design and realization of a first small-scale prototype of this concept, called Relic Axion Detector Exploratory Setup (RADES). It consists of a copper-coated stainless steel five-cavities microwave filter with the detecting mode operating at around 8.4 GHz. This structure has been electromagnetically characterized at 2 K and 298 K, and it is now placed in ultra-high vacuum in one of the twin-bores of the 9 T CAST dipole magnet at CERN. We describe the data acquisition system developed for relic axion detection, and present preliminary results of the electromagnetic properties of the microwave filter, which show the potential of filters to reach QCD axion window sensitivity at X-band frequencies.
△ Less
Submitted 17 May, 2018; v1 submitted 3 March, 2018;
originally announced March 2018.