-
Characterization of the PADME positron beam for the X17 measurement
Authors:
S. Bertelli,
F. Bossi,
B. Buonomo,
R. De Sangro,
C. Di Giulio,
E. Di Meco,
K. Dimitrova,
D. Domenici,
F. Ferrarotto,
G. Finocchiaro,
L. G. Foggetta,
A. Frankenthal,
M. Garattini,
G. Georgiev,
P. Gianotti,
S. Ivanov,
Sv. Ivanov,
V. Kozhuharov,
E. Leonardi,
E. Long,
M. Mancini,
G. C. Organtini,
M. Raggi,
I. Sarra,
R. Simeonov
, et al. (5 additional authors not shown)
Abstract:
This paper presents a detailed characterization of the positron beam delivered by the Beam Test Facility at Laboratori Nazionali of Frascati to the PADME experiment during Run III, which took place from October to December 2022. It showcases the methodology used to measure the main beam parameters such as the position in space, the absolute momentum scale, the beam energy spread, and its intensity…
▽ More
This paper presents a detailed characterization of the positron beam delivered by the Beam Test Facility at Laboratori Nazionali of Frascati to the PADME experiment during Run III, which took place from October to December 2022. It showcases the methodology used to measure the main beam parameters such as the position in space, the absolute momentum scale, the beam energy spread, and its intensity through a combination of data analysis and Monte Carlo simulations. The results achieved include an absolute precision in the momentum of the beam to within $\sim$ 1-2 MeV$/c$, a relative beam energy spread below 0.25\%, and an absolute precision in the intensity of the beam at the level of 2\% percent.
△ Less
Submitted 12 May, 2024;
originally announced May 2024.
-
Status and Prospects of PADME
Authors:
Susanna Bertelli,
Fabio Bossi,
Riccardo De Sangro,
Claudio Di Giulio,
Elisa Di Meco,
Danilo Domenici,
Giuseppe Finocchiaro,
Luca Gennaro Foggetta,
Marco Garattini,
Andrea Ghigo,
Paola Gianotti,
Marco Mancini,
Ivano Sarra,
Tommaso Spadaro,
Eleuterio Spiriti,
Clara Taruggi,
Elisabetta Vilucchi,
Venelin Kozhuharov,
Kalina Dimitrova,
Simeon Ivanov,
Svetoslav Ivanov,
Radoslav Simeonov,
Georgi Georgiev,
Fabio Ferrarotto,
Emanuele Leonardi
, et al. (6 additional authors not shown)
Abstract:
The Positron Annihilation to Dark Matter Experiment (PADME) was designed and constructed to search for dark photons ($A'$) in the process $e^+e^-\rightarrowγA'$, using the positron beam at the Beam Test Facility (BTF) at the National Laboratories of Frascati (LNF). Since the observation of an anomalous spectra in internal pair creation decays of nuclei seen by the collaboration at the ATOMKI insti…
▽ More
The Positron Annihilation to Dark Matter Experiment (PADME) was designed and constructed to search for dark photons ($A'$) in the process $e^+e^-\rightarrowγA'$, using the positron beam at the Beam Test Facility (BTF) at the National Laboratories of Frascati (LNF). Since the observation of an anomalous spectra in internal pair creation decays of nuclei seen by the collaboration at the ATOMKI institute, the PADME detector has been modified and a new data-taking run has been undertaken to probe the existance of the so-called ``X17" particle
△ Less
Submitted 15 May, 2023;
originally announced May 2023.
-
Cross-section measurement of two-photon annihilation in-flight of positrons at $\sqrt{s}=20$ MeV with the PADME detector
Authors:
F. Bossi,
P. Branchini,
B. Buonomo,
V. Capirossi,
A. P. Caricato,
G. Chiodini,
R. De Sangro,
C. Di Giulio,
D. Domenici,
F. Ferrarotto,
G. Finocchiaro,
L. G Foggetta,
A. Frankenthal,
M. Garattini,
G. Georgiev,
F. Giacchino,
P. Gianotti,
S. Ivanov,
Sv. Ivanov,
V. Kozhuharov,
E. Leonardi,
E. Long,
M. Martino,
I. Oceano,
F. Oliva
, et al. (13 additional authors not shown)
Abstract:
The inclusive cross-section of annihilation in flight $e^+e^-\rightarrowγγ$ of 430 MeV positrons with atomic electrons of a thin diamond target has been measured with the PADME detector at the Laboratori Nazionali di Frascati. The two photons produced in the process were detected by an electromagnetic calorimeter made of BGO crystals. This measurement is the first one based on the direct detection…
▽ More
The inclusive cross-section of annihilation in flight $e^+e^-\rightarrowγγ$ of 430 MeV positrons with atomic electrons of a thin diamond target has been measured with the PADME detector at the Laboratori Nazionali di Frascati. The two photons produced in the process were detected by an electromagnetic calorimeter made of BGO crystals. This measurement is the first one based on the direct detection of the photon pair and one of the most precise for positron energies below 1 GeV. This measurement represents a necessary step to search for dark sector particles and mediators weakly coupled to photons and/or electrons with masses ranging from 1 MeV to 20 MeV with PADME. The measurement agrees with the Next to Leading Order QED prediction within the overall 6% uncertainty.
△ Less
Submitted 7 November, 2022; v1 submitted 26 October, 2022;
originally announced October 2022.
-
Dark sector studies with the PADME experiment
Authors:
Anna Paola Caricato,
Maurizio Martino,
Isabella Oceano,
Federica Oliva,
Stefania Spagnolo,
Gabriele Chiodini,
Fabio Bossi,
Riccardo De Sangro,
Claudio Di Giulio,
Danilo Domenici,
Giuseppe Finocchiaro,
Luca Gennaro Foggetta,
Marco Garattini,
Andrea Ghigo,
Federica Giacchino,
Paola Gianotti,
Tommaso Spadaro,
Eletuerio Spiriti,
Clara Taruggi,
Elisabetta Vilucchi,
Venelin Kozhuharov,
Simeon Ivanov,
Svetoslav Ivanov,
Radoslav Simeonov,
Georgi Georgiev
, et al. (13 additional authors not shown)
Abstract:
The Positron Annihilation to Dark Matter Experiment (PADME) uses the positron beam of the DA$Φ$NE Beam-Test Facility, at the Laboratori Nazionali di Frascati (LNF) to search for a Dark Photon $A'$. The search technique studies the missing mass spectrum of single-photon final states in $e^+e^-\rightarrow A'γ$ annihilation in a positron-on-thin-target experiment. This approach facilitates searches f…
▽ More
The Positron Annihilation to Dark Matter Experiment (PADME) uses the positron beam of the DA$Φ$NE Beam-Test Facility, at the Laboratori Nazionali di Frascati (LNF) to search for a Dark Photon $A'$. The search technique studies the missing mass spectrum of single-photon final states in $e^+e^-\rightarrow A'γ$ annihilation in a positron-on-thin-target experiment. This approach facilitates searches for new particles such as long lived Axion-Like-Particles, protophobic X bosons and Dark Higgs. This talk illustrated the scientific program of the experiment and its first physics results. In particular, the measurement of the cross-section of the SM process $e^+e^-\rightarrow γγ$ at $\sqrt{s}$=21 MeV was shown.
△ Less
Submitted 1 May, 2023; v1 submitted 29 September, 2022;
originally announced September 2022.
-
SHERPAD: test of Slow high-efficiency extraction of Positrons from a Ring At DAFNE
Authors:
Paolo Valente,
Davide Annucci,
Oscar Roberto Blanco Garcia,
Marco Garattini,
Paola Gianotti,
Susanna Guiducci,
Andrea Liedl,
Mauro Raggi
Abstract:
The idea of using fixed-target annihilations of a high-energy positron beam on a target for producing a new, very feebly interacting particle has been exploited by the PADME experiment at LNF using the extracted beam from the LINAC in the BTF facility. Extracting the beam from a synchrotron would improve by several orders of magnitude the duty-cycle of the LINAC, thus greatly extending the physics…
▽ More
The idea of using fixed-target annihilations of a high-energy positron beam on a target for producing a new, very feebly interacting particle has been exploited by the PADME experiment at LNF using the extracted beam from the LINAC in the BTF facility. Extracting the beam from a synchrotron would improve by several orders of magnitude the duty-cycle of the LINAC, thus greatly extending the physics reach of such experiments. The option of substituting or complementing the standard, slow 1/3 of integer resonant extraction technique by using coherent phenomena in a bent crystal, like the channeling has been studied by the SHERPA experiment. Both using the DAFNE main positron ring or the smaller dam** ring (accumulator) as pulse extender of the LINAC have been considered.
We here propose to demonstrate the feasibility of this technique performing an experiment on the DAFNE positron main ring, installing in a suitable vacuum goniometer a thin Silicon crystal, bent in the (110) direction in order to provide a ~1 mrad kick, and then simulating the extraction process with a virtual septum: instead of performing a real extraction, the crossing of the gap of a septum magnet is simulated by detecting positrons at its position (at phase advance close to 1/4) by means of a Silicon pixel detector inserted in the ring, in a secondary vacuum of a Roman pot.
△ Less
Submitted 30 June, 2022;
originally announced June 2022.
-
Commissioning of the PADME experiment with a positron beam
Authors:
P. Albicocco,
R. Assiro,
F. Bossi,
P. Branchini,
B. Buonomo,
V. Capirossi,
E. Capitolo,
C. Capoccia,
A. P. Caricato,
S. Ceravolo,
G. Chiodini,
G. Corradi,
R. De Sangro,
C. Di Giulio,
D. Domenici,
F. Ferrarotto,
S. Fiore,
G. Finocchiaro,
L. G Foggetta,
A. Frankenthal,
M. Garattini,
G. Georgiev,
F. Giacchino,
A. Ghigo,
P. Gianotti
, et al. (31 additional authors not shown)
Abstract:
The PADME experiment is designed to search for a hypothetical dark photon $A^{\prime}$ produced in positron-electron annihilation using a bunched positron beam at the Beam Test Facility of the INFN Laboratori Nazionali di Frascati. The expected sensitivity to the $A^{\prime}$-photon mixing parameter $ε$ is 10$^{-3}$, for $A^{\prime}$ mass $\le$ 23.5 MeV/$c^{2}$ after collecting $\sim 10^{13}$ posi…
▽ More
The PADME experiment is designed to search for a hypothetical dark photon $A^{\prime}$ produced in positron-electron annihilation using a bunched positron beam at the Beam Test Facility of the INFN Laboratori Nazionali di Frascati. The expected sensitivity to the $A^{\prime}$-photon mixing parameter $ε$ is 10$^{-3}$, for $A^{\prime}$ mass $\le$ 23.5 MeV/$c^{2}$ after collecting $\sim 10^{13}$ positrons-on-target.
This paper presents the PADME detector status after commissioning in July 2019. In addition, the software algorithms employed to reconstruct physics objects, such as photons and charged particles, and the calibration procedures adopted are illustrated in detail. The results show that the experimental apparatus reaches the design performance, and is able to identify and measure standard electromagnetic processes, such as positron Bremsstrahlung, electron-positron annihilation into two photons.
△ Less
Submitted 20 July, 2022; v1 submitted 6 May, 2022;
originally announced May 2022.
-
The PADME beam line Monte Carlo simulation
Authors:
F. Bossi,
P. Branchini,
B. Buonomo,
V. Capirossi,
A. P. Caricato,
G. Chiodini,
R. De Sangro,
C. Di Giulio,
D. Domenici,
F. Ferrarotto,
S. Fiore,
G. Finocchiaro,
L. G Foggetta,
A. Frankenthal,
M. Garattini,
G. Georgiev,
A. Ghigo,
P. Gianotti,
F. Iazzi,
S. Ivanov,
Sv. Ivanov,
V. Kozhuharov,
E. Leonardi,
E. Long,
M. Martino
, et al. (16 additional authors not shown)
Abstract:
The PADME experiment at the DA$Φ$NE Beam-Test Facility (BTF) of the INFN Laboratory of Frascati is designed to search for invisible decays of dark sector particles produced in electron-positron annihilation events with a positron beam and a thin fixed target, by measuring the missing mass of single-photon final states. The presence of backgrounds originating from beam halo particles can significan…
▽ More
The PADME experiment at the DA$Φ$NE Beam-Test Facility (BTF) of the INFN Laboratory of Frascati is designed to search for invisible decays of dark sector particles produced in electron-positron annihilation events with a positron beam and a thin fixed target, by measuring the missing mass of single-photon final states. The presence of backgrounds originating from beam halo particles can significantly reduce the sensitivity of the experiment. To thoroughly understand the origin of the beam background contribution, a detailed Geant4-based Monte Carlo simulation has been developed, containing a full description of the detector together with the beam line and its optical elements. This simulation allows the full interactions of each particle to be described, both during beam line transport and during detection, a possibility which represents an innovative way to obtain reliable background predictions
△ Less
Submitted 12 April, 2022;
originally announced April 2022.
-
Multiple scattering of channeled and non-channeled positively charged particles in bent monocrystalline silicon
Authors:
W. Scandale,
G. Arduini,
F. Cerutti,
L. S. Esposito,
M. Garattini,
S. Gilardoni,
R. Losito,
A. Masi,
D. Mirarchi,
S. Montesano,
S. Redaelli,
R. Rossi,
G. Smirnov,
L. Burmistrov,
S. Dubos,
V. Puill,
A. Stocchi,
L. Bandiera,
V. Guidi,
A. Mazzolari,
M. Romagnoni,
F. Murtas,
F. Addesa,
G. Cavoto,
F. Iacoangeli
, et al. (17 additional authors not shown)
Abstract:
We present the results of an experimental study of multiple scattering of positively charged high energy particles in bent samples of monocrystalline silicon. This work confirms the recently discovered effect of a strong reduction in the rms multiple scattering angle of particles channeled in the silicon (111) plane. The effect is observed in the plane orthogonal to the bending plane. We show in d…
▽ More
We present the results of an experimental study of multiple scattering of positively charged high energy particles in bent samples of monocrystalline silicon. This work confirms the recently discovered effect of a strong reduction in the rms multiple scattering angle of particles channeled in the silicon (111) plane. The effect is observed in the plane orthogonal to the bending plane. We show in detail the influence of angular constraints on the magnitude of the effect. Comparison of the multiple scattering process at different energies indicates a violation of the law of inverse proportionality of the rms angle of channeled particles with energy. By increasing the statistics, we have improved the results of multiple scattering measurements for particles moving, but not channeled, in silicon crystals.
△ Less
Submitted 31 January, 2022; v1 submitted 24 January, 2022;
originally announced January 2022.
-
Crystal slow extraction of positrons from DAFNE: the SHERPA project
Authors:
M. Garattini,
D. Annucci,
O. R. Blanco-Garcia,
P. Gianotti,
S. Guiducci,
A. Liedl,
M. Raggi,
P. Valente
Abstract:
The SHERPA project aim is to develop an efficient technique to extract a positron beam from one of the accelerator rings composing the DAFNE complex at the Frascati National Laboratory of INFN, setting up a new beam line able to deliver positron spills of O(ms) length, excellent beam energy spread and emittance. The most common approach to slowly extract from a ring is to increase betatron oscilla…
▽ More
The SHERPA project aim is to develop an efficient technique to extract a positron beam from one of the accelerator rings composing the DAFNE complex at the Frascati National Laboratory of INFN, setting up a new beam line able to deliver positron spills of O(ms) length, excellent beam energy spread and emittance. The most common approach to slowly extract from a ring is to increase betatron oscillations approaching a tune resonance in order to gradually eject particles from the circulating beam. SHERPA proposes a paradigm change using coherent processes in bent crystals to kick out positrons from the ring, a cheaper and less complex alternative. A description of this innovative non-resonant extraction technique is reported in this manuscript, including its performance preliminary estimation.
△ Less
Submitted 6 October, 2021;
originally announced October 2021.
-
Double-crystal measurements at the CERN SPS
Authors:
W. Scandale,
G. Arduini,
F. Cerutti,
M. D'Andrea,
L. S. Esposito,
M. Garattini,
S. Gilardoni,
D. Mirarchi,
S. Montesano,
A. Natochii,
S. Redaelli,
R. Rossi,
G. I. Smirnov,
L. Burmistrov,
S. Dubos,
V. Puill,
A. Stocchi,
F. Addesa,
F. Murtas,
F. Galluccio,
A. D. Kovalenko,
A. M. Taratin,
A. S. Denisov,
Yu. A. Gavrikov,
Yu. M. Ivanov
, et al. (13 additional authors not shown)
Abstract:
The UA9 setup, installed in the Super Proton Synchrotron (SPS) at CERN, was exploited for a proof of principle of the double-crystal scenario, proposed to measure the electric and the magnetic moments of short-lived baryons in a high-energy hadron collider, such as the Large Hadron Collider (LHC). Linear and angular actuators were used to position the crystals and establish the required beam confi…
▽ More
The UA9 setup, installed in the Super Proton Synchrotron (SPS) at CERN, was exploited for a proof of principle of the double-crystal scenario, proposed to measure the electric and the magnetic moments of short-lived baryons in a high-energy hadron collider, such as the Large Hadron Collider (LHC). Linear and angular actuators were used to position the crystals and establish the required beam configuration. Timepix detectors and high-sensitivity Beam Loss Monitors were exploited to observe the deflected beams. Linear and angular scans allowed exploring the particle interactions with the two crystals and recording their efficiency. The measured values of the beam trajectories, profiles and of the channeling efficiency agree with the results of a Monte-Carlo simulation.
△ Less
Submitted 26 March, 2021;
originally announced March 2021.
-
Reduction of multiple scattering of high-energy positively charged particles during channeling in single crystals
Authors:
W. Scandale,
L. S. Esposito,
M. Garattini,
R. Rossi,
V. Zhovkovska,
A. Natochii,
F. Addesa,
F. Iacoangeli,
F. Galluccio,
F. Murtas,
A. G. Afonin,
Yu. A. Chesnokov,
A. A. Durum,
V. A. Maisheev,
Yu. E. Sandomirskiy,
A. A. Yanovich,
G. I. Smirnov,
Yu. A. Gavrikov,
Yu. M. Ivanov,
M. A. Koznov,
M. V. Malkov,
L. G. Malyarenko,
I. G. Mamunct,
J. Borg,
T. James
, et al. (2 additional authors not shown)
Abstract:
We present the experimental observation of the reduction of multiple scattering of high-energy positively charged particles during channeling in single crystals. According to our measurements the rms angle of multiple scattering in the plane orthogonal to the plane of the channeling is less than half that for non-channeled particles moving in the same crystal. In the experiment we use focusing ben…
▽ More
We present the experimental observation of the reduction of multiple scattering of high-energy positively charged particles during channeling in single crystals. According to our measurements the rms angle of multiple scattering in the plane orthogonal to the plane of the channeling is less than half that for non-channeled particles moving in the same crystal. In the experiment we use focusing bent single crystals. Such crystals have a variable thickness in the direction of beam propagation. This allows us to measure rms angles of scattering as a function of thickness for channeled and non-channeled particles. The behaviour with thickness of non-channeled particles is in agreement with expectations whereas the behaviour of channeled particles has unexpected features. We give a semi-quantitative explanation of the observed effect.
△ Less
Submitted 1 October, 2019;
originally announced October 2019.
-
Double-crystal setup measurements at the CERN SPS
Authors:
W. Scandale,
F. Cerutti,
L. S. Esposito,
M. Garattini,
S. Gilardoni,
S. Montesano,
R. Rossi,
L. Burmistrov,
S. Dubos,
A. Natochii,
V. Puill,
A. Stocchi,
V. Zhovkovska,
F. Murtas,
F. Addesa,
F. Iacoangeli,
F. Galluccio,
A. D. Kovalenko,
A. M. Taratin,
G. I. Smirnov,
A. S. Denisov,
Yu. A. Gavrikov,
Yu. M. Ivanov,
L. P. Lapina,
L. G. Malyarenko
, et al. (11 additional authors not shown)
Abstract:
In this paper, we discuss an experimental layout for the two-crystals scenario at the Super Proton Synchrotron (SPS) accelerator. The research focuses on a fixed target setup at the circulating machine in a frame of the Physics Beyond Colliders (PBC) project at CERN. The UA9 experiment at the SPS serves as a testbench for the proof of concept, which is planning to be projected onto the Large Hadro…
▽ More
In this paper, we discuss an experimental layout for the two-crystals scenario at the Super Proton Synchrotron (SPS) accelerator. The research focuses on a fixed target setup at the circulating machine in a frame of the Physics Beyond Colliders (PBC) project at CERN. The UA9 experiment at the SPS serves as a testbench for the proof of concept, which is planning to be projected onto the Large Hadron Collider (LHC) scale. The presented in the text configuration was used for the quantitative characterization of the deflected particle beam by a pair of bent silicon crystals. For the first time in the double-crystal configuration, a particle deflection efficiency by the second crystal of $0.188 \pm 3 \cdot 10^{-5}$ and $0.179 \pm 0.013$ was measured on the accelerator by means of the Timepix detector and Beam Loss Monitor (BLM) respectively. In this setup, a wide range angular scan allowed a possibility to \textit{in situ} investigate different crystal working regimes (channeling, volume reflection, etc.), and to measure a bent crystal torsion.
△ Less
Submitted 6 September, 2019;
originally announced September 2019.
-
Results on Multiple Coulomb Scattering from 12 and 20 GeV electrons on Carbon targets
Authors:
G. Abbiendi,
J. Bernhard,
F. Betti,
M. Bonanomi,
C. M. Carloni Calame,
M. Garattini,
Y. Gavrikov,
G. Hall,
F. Iacoangeli,
F. Ignatov,
M. Incagli,
V. Ivanchenko,
F. Ligabue,
T. O. James,
U. Marconi,
C. Matteuzzi,
M. Passera,
M. Pesaresi,
F. Piccinini,
R. N. Pilato,
F. Pisani,
A. Principe,
W. Scandale,
R. Tenchini,
G. Venanzoni
Abstract:
Multiple scattering effects of 12 and 20 GeV electrons on 8 and 20 mm thickness carbon targets have been studied with high-resolution silicon microstrip detectors of the UA9 apparatus at the H8 line at CERN. Comparison of the scattering angle between data and GEANT4 simulation shows excellent agreement in the core of the distributions leaving some residual disagreement in the tails.
Multiple scattering effects of 12 and 20 GeV electrons on 8 and 20 mm thickness carbon targets have been studied with high-resolution silicon microstrip detectors of the UA9 apparatus at the H8 line at CERN. Comparison of the scattering angle between data and GEANT4 simulation shows excellent agreement in the core of the distributions leaving some residual disagreement in the tails.
△ Less
Submitted 19 April, 2020; v1 submitted 28 May, 2019;
originally announced May 2019.
-
Commissioning and operation of the Cherenkov detector for proton Flux Measurement of the UA9 Experiment
Authors:
F. M. Addesa,
L. Burmistrov,
D. Breton,
G. Cavoto,
V. Chaumat,
S. Dubos,
L. Esposito,
F. Galluccio,
M. Garattini,
F. Iacoangeli,
J. Maalmi,
D. Mirarchi,
A. Natochii,
V. Puill,
R. Rossi,
W. Scandale,
S. Montesano,
A. Stocchi
Abstract:
The UA9 Experiment at CERN-SPS investigates channeling processes in bent silicon crystals with the aim to manipulate hadron beams. Monitoring and characterization of channeled beams in the high energy accelerators environment ideally requires in-vacuum and radiation hard detectors. For this purpose the Cherenkov detector for proton Flux Measurement (CpFM) was designed and developed. It is based on…
▽ More
The UA9 Experiment at CERN-SPS investigates channeling processes in bent silicon crystals with the aim to manipulate hadron beams. Monitoring and characterization of channeled beams in the high energy accelerators environment ideally requires in-vacuum and radiation hard detectors. For this purpose the Cherenkov detector for proton Flux Measurement (CpFM) was designed and developed. It is based on thin fused silica bars in the beam pipe vacuum which intercept charged particles and generate Cherenkov light. The first version of the CpFM is installed since 2015 in the crystal-assisted collimation setup of the UA9 experiment. In this paper the procedures to make the detector operational and fully integrated in the UA9 setup are described. The most important standard operations of the detector are presented. They have been used to commission and characterize the detector, providing moreover the measurement of the integrated channeled beam profile and several functionality tests as the determination of the crystal bending angle.
The calibration has been performed with Lead (Pb) and Xenon (Xe) beams and the results are applied to the flux measurement discussed here in detail.
△ Less
Submitted 12 April, 2019;
originally announced April 2019.