-
Measurement of the cosmic-ray proton spectrum from 40 GeV to 100 TeV with the DAMPE satellite
Authors:
Q. An,
R. Asfandiyarov,
P. Azzarello,
P. Bernardini,
X. J. Bi,
M. S. Cai,
J. Chang,
D. Y. Chen,
H. F. Chen,
J. L. Chen,
W. Chen,
M. Y. Cui,
T. S. Cui,
H. T. Dai,
A. D'Amone,
A. De Benedittis,
I. De Mitri,
M. Di Santo,
M. Ding,
T. K. Dong,
Y. F. Dong,
Z. X. Dong,
G. Donvito,
D. Droz,
J. L. Duan
, et al. (129 additional authors not shown)
Abstract:
The precise measurement of the spectrum of protons, the most abundant component of the cosmic radiation, is necessary to understand the source and acceleration of cosmic rays in the Milky Way. This work reports the measurement of the cosmic ray proton fluxes with kinetic energies from 40 GeV to 100 TeV, with two and a half years of data recorded by the DArk Matter Particle Explorer (DAMPE). This i…
▽ More
The precise measurement of the spectrum of protons, the most abundant component of the cosmic radiation, is necessary to understand the source and acceleration of cosmic rays in the Milky Way. This work reports the measurement of the cosmic ray proton fluxes with kinetic energies from 40 GeV to 100 TeV, with two and a half years of data recorded by the DArk Matter Particle Explorer (DAMPE). This is the first time an experiment directly measures the cosmic ray protons up to ~100 TeV with a high statistics. The measured spectrum confirms the spectral hardening found by previous experiments and reveals a softening at ~13.6 TeV, with the spectral index changing from ~2.60 to ~2.85. Our result suggests the existence of a new spectral feature of cosmic rays at energies lower than the so-called knee, and sheds new light on the origin of Galactic cosmic rays.
△ Less
Submitted 30 September, 2019; v1 submitted 27 September, 2019;
originally announced September 2019.
-
The on-orbit calibration of DArk Matter Particle Explorer
Authors:
G. Ambrosi,
Q. An,
R. Asfandiyarov,
P. Azzarello,
P. Bernardini,
M. S. Cai,
M. Caragiulo,
J. Chang,
D. Y. Chen,
H. F. Chen,
J. L. Chen,
W. Chen,
M. Y. Cui,
T. S. Cui,
H. T. Dai,
A. D'Amone,
A. De Benedittis,
I. De Mitri,
M. Ding,
M. Di Santo,
J. N. Dong,
T. K. Dong,
Y. F. Dong,
Z. X. Dong,
D. Droz
, et al. (133 additional authors not shown)
Abstract:
The DArk Matter Particle Explorer (DAMPE), a satellite-based cosmic ray and gamma-ray detector, was launched on December 17, 2015, and began its on-orbit operation on December 24, 2015. In this work we document the on-orbit calibration procedures used by DAMPE and report the calibration results of the Plastic Scintillator strip Detector (PSD), the Silicon-Tungsten tracKer-converter (STK), the BGO…
▽ More
The DArk Matter Particle Explorer (DAMPE), a satellite-based cosmic ray and gamma-ray detector, was launched on December 17, 2015, and began its on-orbit operation on December 24, 2015. In this work we document the on-orbit calibration procedures used by DAMPE and report the calibration results of the Plastic Scintillator strip Detector (PSD), the Silicon-Tungsten tracKer-converter (STK), the BGO imaging calorimeter (BGO), and the Neutron Detector (NUD). The results are obtained using Galactic cosmic rays, bright known GeV gamma-ray sources, and charge injection into the front-end electronics of each sub-detector. The determination of the boundary of the South Atlantic Anomaly (SAA), the measurement of the live time, and the alignments of the detectors are also introduced. The calibration results demonstrate the stability of the detectors in almost two years of the on-orbit operation.
△ Less
Submitted 3 July, 2019;
originally announced July 2019.
-
Calibration of the DAMPE Plastic Scintillator Detector and its on-orbit performance
Authors:
Meng Ding,
Yapeng Zhang,
Yong-Jie Zhang,
Yuan-Peng Wang,
Tie-Kuang Dong,
Antonio De Benedittis,
Paolo Bernardini,
Fang Fang,
Yao Li,
Jie Liu,
Peng-Xiong Ma,
Zhi-Yu Sun,
Valentina Gallo,
Stefania Vitillo,
Zhao-Min Wang,
Yu-Hong Yu,
Chuan Yue,
Qiang Yuan,
Yong Zhou,
Yun-Long Zhang
Abstract:
DArk Matter Particle Explorer (DAMPE) is a space-borne apparatus for detecting the high-energy cosmic-rays like electrons, $γ$-rays, protons and heavy-ions. Plastic Scintillator Detector (PSD) is the top-most sub-detector of the DAMPE. The PSD is designed to measure the charge of incident high-energy particles and it also serves as a veto detector for discriminating $γ$-rays from charged particles…
▽ More
DArk Matter Particle Explorer (DAMPE) is a space-borne apparatus for detecting the high-energy cosmic-rays like electrons, $γ$-rays, protons and heavy-ions. Plastic Scintillator Detector (PSD) is the top-most sub-detector of the DAMPE. The PSD is designed to measure the charge of incident high-energy particles and it also serves as a veto detector for discriminating $γ$-rays from charged particles. In this paper, PSD on-orbit calibration procedure is described, which includes five steps of pedestal, dynode correlation, response to minimum-ionizing particles (MIPs), light attenuation function and energy reconstruction. A method for reconstructing the charge of incident high energy cosmic-ray particles is introduced. The detection efficiency of each PSD strip is verified to be above 99.5%, the total efficiency of the PSD for charged particles is above 99.99%.
△ Less
Submitted 23 October, 2018;
originally announced October 2018.
-
In-flight performance of the DAMPE silicon tracker
Authors:
A. Tykhonov,
G. Ambrosi,
R. Asfandiyarov,
P. Azzarello,
P. Bernardini,
B. Bertucci,
A. Bolognini,
F. Cadoux,
A. D'Amone,
A. De Benedittis,
I. De Mitri,
M. Di Santo,
Y. F. Dong,
M. Duranti,
D. D'Urso,
R. R. Fan,
P. Fusco,
V. Gallo,
M. Gao,
F. Gargano,
S. Garrappa,
K. Gong,
M. Ionica,
D. La Marra,
F. Loparco
, et al. (17 additional authors not shown)
Abstract:
DAMPE (DArk Matter Particle Explorer) is a spaceborne high-energy cosmic ray and gamma-ray detector, successfully launched in December 2015. It is designed to probe astroparticle physics in the broad energy range from few GeV to 100 TeV. The scientific goals of DAMPE include the identification of possible signatures of Dark Matter annihilation or decay, the study of the origin and propagation mech…
▽ More
DAMPE (DArk Matter Particle Explorer) is a spaceborne high-energy cosmic ray and gamma-ray detector, successfully launched in December 2015. It is designed to probe astroparticle physics in the broad energy range from few GeV to 100 TeV. The scientific goals of DAMPE include the identification of possible signatures of Dark Matter annihilation or decay, the study of the origin and propagation mechanisms of cosmic-ray particles, and gamma-ray astronomy. DAMPE consists of four sub-detectors: a plastic scintillator strip detector, a Silicon-Tungsten tracKer-converter (STK), a BGO calorimeter and a neutron detector. The STK is composed of six double layers of single-sided silicon micro-strip detectors interleaved with three layers of tungsten for photon conversions into electron-positron pairs. The STK is a crucial component of DAMPE, allowing to determine the direction of incoming photons, to reconstruct tracks of cosmic rays and to estimate their absolute charge (Z). We present the in-flight performance of the STK based on two years of in-flight DAMPE data, which includes the noise behavior, signal response, thermal and mechanical stability, alignment and position resolution.
△ Less
Submitted 27 June, 2018;
originally announced June 2018.
-
Internal alignment and position resolution of the silicon tracker of DAMPE determined with orbit data
Authors:
A. Tykhonov,
G. Ambrosi,
R. Asfandiyarov,
P. Azzarello,
P. Bernardini,
B. Bertucci,
A. Bolognini,
F. Cadoux,
A. D'Amone,
A. De Benedittis,
I. De Mitri,
M. Di Santo,
Y. F. Dong,
M. Duranti,
D. D'Urso,
R. R. Fan,
P. Fusco,
V. Gallo,
M. Gao,
F. Gargano,
S. Garrappa,
K. Gong,
M. Ionica,
D. La Marra,
S. J. Lei
, et al. (18 additional authors not shown)
Abstract:
The DArk Matter Particle Explorer (DAMPE) is a space-borne particle detector designed to probe electrons and gamma-rays in the few GeV to 10 TeV energy range, as well as cosmic-ray proton and nuclei components between 10 GeV and 100 TeV. The silicon-tungsten tracker-converter is a crucial component of DAMPE. It allows the direction of incoming photons converting into electron-positron pairs to be…
▽ More
The DArk Matter Particle Explorer (DAMPE) is a space-borne particle detector designed to probe electrons and gamma-rays in the few GeV to 10 TeV energy range, as well as cosmic-ray proton and nuclei components between 10 GeV and 100 TeV. The silicon-tungsten tracker-converter is a crucial component of DAMPE. It allows the direction of incoming photons converting into electron-positron pairs to be estimated, and the trajectory and charge (Z) of cosmic-ray particles to be identified. It consists of 768 silicon micro-strip sensors assembled in 6 double layers with a total active area of 6.6 m$^2$. Silicon planes are interleaved with three layers of tungsten plates, resulting in about one radiation length of material in the tracker. Internal alignment parameters of the tracker have been determined on orbit, with non-showering protons and helium nuclei. We describe the alignment procedure and present the position resolution and alignment stability measurements.
△ Less
Submitted 22 March, 2018; v1 submitted 7 December, 2017;
originally announced December 2017.
-
Direct detection of a break in the teraelectronvolt cosmic-ray spectrum of electrons and positrons
Authors:
G. Ambrosi,
Q. An,
R. Asfandiyarov,
P. Azzarello,
P. Bernardini,
B. Bertucci,
M. S. Cai,
J. Chang,
D. Y. Chen,
H. F. Chen,
J. L. Chen,
W. Chen,
M. Y. Cui,
T. S. Cui,
A. D'Amone,
A. De Benedittis,
I. De Mitri,
M. Di Santo,
J. N. Dong,
T. K. Dong,
Y. F. Dong,
Z. X. Dong,
G. Donvito,
D. Droz,
K. K. Duan
, et al. (133 additional authors not shown)
Abstract:
High energy cosmic ray electrons plus positrons (CREs), which lose energy quickly during their propagation, provide an ideal probe of Galactic high-energy processes and may enable the observation of phenomena such as dark-matter particle annihilation or decay. The CRE spectrum has been directly measured up to $\sim 2$ TeV in previous balloon- or space-borne experiments, and indirectly up to…
▽ More
High energy cosmic ray electrons plus positrons (CREs), which lose energy quickly during their propagation, provide an ideal probe of Galactic high-energy processes and may enable the observation of phenomena such as dark-matter particle annihilation or decay. The CRE spectrum has been directly measured up to $\sim 2$ TeV in previous balloon- or space-borne experiments, and indirectly up to $\sim 5$ TeV by ground-based Cherenkov $γ$-ray telescope arrays. Evidence for a spectral break in the TeV energy range has been provided by indirect measurements of H.E.S.S., although the results were qualified by sizeable systematic uncertainties. Here we report a direct measurement of CREs in the energy range $25~{\rm GeV}-4.6~{\rm TeV}$ by the DArk Matter Particle Explorer (DAMPE) with unprecedentedly high energy resolution and low background. The majority of the spectrum can be properly fitted by a smoothly broken power-law model rather than a single power-law model. The direct detection of a spectral break at $E \sim0.9$ TeV confirms the evidence found by H.E.S.S., clarifies the behavior of the CRE spectrum at energies above 1 TeV and sheds light on the physical origin of the sub-TeV CREs.
△ Less
Submitted 29 November, 2017;
originally announced November 2017.
-
The DArk Matter Particle Explorer mission
Authors:
J. Chang,
G. Ambrosi,
Q. An,
R. Asfandiyarov,
P. Azzarello,
P. Bernardini,
B. Bertucci,
M. S. Cai,
M. Caragiulo,
D. Y. Chen,
H. F. Chen,
J. L. Chen,
W. Chen,
M. Y. Cui,
T. S. Cui,
A. D'Amone,
A. De Benedittis,
I. De Mitri,
M. Di Santo,
J. N. Dong,
T. K. Dong,
Y. F. Dong,
Z. X. Dong,
G. Donvito,
D. Droz
, et al. (139 additional authors not shown)
Abstract:
The DArk Matter Particle Explorer (DAMPE), one of the four scientific space science missions within the framework of the Strategic Pioneer Program on Space Science of the Chinese Academy of Sciences, is a general purpose high energy cosmic-ray and gamma-ray observatory, which was successfully launched on December 17th, 2015 from the Jiuquan Satellite Launch Center. The DAMPE scientific objectives…
▽ More
The DArk Matter Particle Explorer (DAMPE), one of the four scientific space science missions within the framework of the Strategic Pioneer Program on Space Science of the Chinese Academy of Sciences, is a general purpose high energy cosmic-ray and gamma-ray observatory, which was successfully launched on December 17th, 2015 from the Jiuquan Satellite Launch Center. The DAMPE scientific objectives include the study of galactic cosmic rays up to $\sim 10$ TeV and hundreds of TeV for electrons/gammas and nuclei respectively, and the search for dark matter signatures in their spectra. In this paper we illustrate the layout of the DAMPE instrument, and discuss the results of beam tests and calibrations performed on ground. Finally we present the expected performance in space and give an overview of the mission key scientific goals.
△ Less
Submitted 14 September, 2017; v1 submitted 26 June, 2017;
originally announced June 2017.
-
Charge reconstruction study of the DAMPE Silicon-Tungsten Tracker with ion beams
Authors:
Rui Qiao,
Wen-Xi Peng,
Dong-Ya Guo,
Hao Zhao,
Huan-Yu Wang,
Ke Gong,
Fei Zhang,
Xin Wu,
Phillip Azzarello,
Andrii Tykhonov,
Ruslan Asfandiyarov,
Valentina Gallo,
Giovanni Ambrosi,
Nicola Mazziotta,
Ivan De Mitri
Abstract:
The DArk Matter Particle Explorer (DAMPE) is one of the four satellites within Strategic Pioneer Research Program in Space Science of the Chinese Academy of Science (CAS). DAMPE can detect electrons, photons in a wide energy range (5 GeV to 10 TeV) and ions up to iron (100GeV to 100 TeV). Silicon-Tungsten Tracker (STK) is one of the four subdetectors in DAMPE, providing photon-electron conversion,…
▽ More
The DArk Matter Particle Explorer (DAMPE) is one of the four satellites within Strategic Pioneer Research Program in Space Science of the Chinese Academy of Science (CAS). DAMPE can detect electrons, photons in a wide energy range (5 GeV to 10 TeV) and ions up to iron (100GeV to 100 TeV). Silicon-Tungsten Tracker (STK) is one of the four subdetectors in DAMPE, providing photon-electron conversion, track reconstruction and charge identification for ions. Ion beam test was carried out in CERN with 60GeV/u Lead primary beams. Charge reconstruction and charge resolution of STK detectors were investigated.
△ Less
Submitted 27 May, 2017;
originally announced May 2017.
-
Design of the readout electronics for the DAMPE Silicon Tracker detector
Authors:
Fei Zhang,
Wen-Xi Peng,
Ke Gong,
Di Wu,
Yi-Fan Dong,
Rui Qiao,
Rui-Rui Fan,
**-Zhou Wang,
Huan-Yu Wang,
Xin Wu,
Daniel La Marra,
Philipp Azzarello,
Valentina Gallo,
Giovanni Ambrosi,
Andrea Nardinocchi
Abstract:
The Silicon Tracker (STK) is a detector of the DAMPE satellite to measure the incidence direction of high energy cosmic ray. It consists of 6 X-Y double layers of silicon micro-strip detectors with 73,728 readout channels. It's a great challenge to readout the channels and process the huge volume of data in the critical space environment. 1152 Application Specific Integrated Circuits (ASIC) and 38…
▽ More
The Silicon Tracker (STK) is a detector of the DAMPE satellite to measure the incidence direction of high energy cosmic ray. It consists of 6 X-Y double layers of silicon micro-strip detectors with 73,728 readout channels. It's a great challenge to readout the channels and process the huge volume of data in the critical space environment. 1152 Application Specific Integrated Circuits (ASIC) and 384 ADCs are adopted to readout the detector channels. The 192 Tracker Front-end Hybrid (TFH) modules and 8 identical Tracker Readout Board (TRB) modules are designed to control and digitalize the front signals. In this paper, the design of the readout electronics for STK and its performance will be presented in detail.
△ Less
Submitted 16 June, 2016;
originally announced June 2016.
-
Oxygen contamination in liquid Argon: combined effects on ionization electron charge and scintillation light
Authors:
R. Acciarri,
M. Antonello,
B. Baibussinov,
M. Baldo-Ceolin,
P. Benetti,
F. Calaprice,
E. Calligarich,
M. Cambiaghi,
N. Canci,
F. Carbonara,
F. Cavanna,
S. Centro,
A. G. Cocco,
F. Di Pompeo,
G. Fiorillo,
C. Galbiati,
V. Gallo,
L. Grandi,
G. Meng,
I. Modena,
C. Montanari,
O. Palamara,
L. Pandola,
F. Pietropaolo,
G. L. Raselli
, et al. (8 additional authors not shown)
Abstract:
A dedicated test of the effects of Oxygen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. Two detectors have been used: the WArP 2.3 lt prototype and a small (0.7 lt) dedicated detector, coupled with a system for the injection of controlled amounts of gaseous Oxygen. Purpose of the test with the 0.7 lt detector is to d…
▽ More
A dedicated test of the effects of Oxygen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. Two detectors have been used: the WArP 2.3 lt prototype and a small (0.7 lt) dedicated detector, coupled with a system for the injection of controlled amounts of gaseous Oxygen. Purpose of the test with the 0.7 lt detector is to detect the reduction of the long-lived component lifetime of the Argon scintillation light emission at increasing O2 concentration. Data from the WArP prototype are used for determining the behavior of both the ionization electron lifetime and the scintillation long-lived component lifetime during the O2-purification process activated in closed loop during the acquisition run. The electron lifetime measurements allow to infer the O2 content of the Argon and correlate it with the long-lived scintillation lifetime data. The effect of Oxygen contamination on the scintillation light has been thus measured over a wide range of O2 concentration, spanning from about 10^-3 ppm up to about 10 ppm. The rate constant of the light quenching process induced by Oxygen in LAr has been found to be k'(O2)=0.54+-0.03 micros^-1 ppm^-1.
△ Less
Submitted 8 April, 2008;
originally announced April 2008.
-
Effects of Nitrogen contamination in liquid Argon
Authors:
R. Acciarri,
M. Antonello,
B. Baibussinov,
M. Baldo-Ceolin,
P. Benetti,
F. Calaprice,
E. Calligarich,
M. Cambiaghi,
N. Canci,
F. Carbonara,
F. Cavanna,
S. Centro,
A. G. Cocco,
F. Di Pompeo,
G. Fiorillo,
C. Galbiati,
V. Gallo,
L. Grandi,
G. Meng,
I. Modena,
C. Montanari,
O. Palamara,
L. Pandola,
F. Pietropaolo,
G. L. Raselli
, et al. (7 additional authors not shown)
Abstract:
A dedicated test of the effects of Nitrogen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. A detector has been designed and assembled for this specific task and connected to a system for the injection of controlled amounts of gaseous Nitrogen into the liquid Argon. Purpose of the test is to detect the reduction of the…
▽ More
A dedicated test of the effects of Nitrogen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. A detector has been designed and assembled for this specific task and connected to a system for the injection of controlled amounts of gaseous Nitrogen into the liquid Argon. Purpose of the test is to detect the reduction of the Ar scintillation light emission as a function of the amount of the Nitrogen contaminant injected in the Argon volume. A wide concentration range, spanning from about 10^-1 ppm up to about 10^3 ppm, has been explored. Measurements have been done with electrons in the energy range of minimum ionizing particles (gamma-conversion from radioactive sources). Source spectra at different Nitrogen contaminations are analyzed, showing sensitive reduction of the scintillation yield at increasing concentrations. The rate constant of the light quenching process induced by Nitrogen in liquid Ar has been found to be k(N2)=0.11 micros^-1 ppm^-1. Direct PMT signals acquisition at high time resolution by fast Waveform recording allowed to extract with high precision the main characteristics of the scintillation light emission in pure and contaminated LAr. In particular, the decreasing behavior in lifetime and relative amplitude of the slow component is found to be appreciable from O(1 ppm) of Nitrogen concentrations.
△ Less
Submitted 8 April, 2008;
originally announced April 2008.
-
First results from a Dark Matter search with liquid Argon at 87 K in the Gran Sasso Underground Laboratory
Authors:
P. Benetti,
R. Acciarri,
F. Adamo,
B. Baibussinov,
M. Baldo-Ceolin,
M. Belluco,
F. Calaprice,
E. Calligarich,
M. Cambiaghi,
F. Carbonara,
F. Cavanna,
S. Centro,
A. G. Cocco,
F. Di Pompeo,
N. Ferrari,
G. Fiorillo,
C. Galbiati,
V. Gallo,
L. Grandi,
A. Ianni,
G. Mangano,
G. Meng,
C. Montanari,
O. Palamara,
L. Pandola
, et al. (7 additional authors not shown)
Abstract:
A new method of searching for dark matter in the form of weakly interacting massive particles (WIMP) has been developed with the direct detection of the low energy nuclear recoils observed in a massive target (ultimately many tons) of ultra pure Liquid Argon at 87 K. A high selectivity for Argon recoils is achieved by the simultaneous observation of both the VUV scintillation luminescence and of…
▽ More
A new method of searching for dark matter in the form of weakly interacting massive particles (WIMP) has been developed with the direct detection of the low energy nuclear recoils observed in a massive target (ultimately many tons) of ultra pure Liquid Argon at 87 K. A high selectivity for Argon recoils is achieved by the simultaneous observation of both the VUV scintillation luminescence and of the electron signal surviving columnar recombination, extracted through the liquid-gas boundary by an electric field. First physics results from this method are reported, based on a small 2.3 litre test chamber filled with natural Argon and an accumulated fiducial exposure of about 100 kg x day, supporting the future validity of this method with isotopically purified 40Ar and for a much larger unit presently under construction with correspondingly increased sensitivities.
△ Less
Submitted 16 January, 2007; v1 submitted 10 January, 2007;
originally announced January 2007.