-
Quantitative Diffractometric Biosensing
Authors:
Yves Blickenstorfer,
Markus Müller,
Roland Dreyfus,
Andreas Michael Reichmuth,
Christof Fattinger,
Andreas Frutiger
Abstract:
Diffractometric biosensing is a promising technology to overcome critical limitations of refractometric biosensors, the dominant class of label-free optical transducers. These limitations manifest themselves by higher noise and drifts due to insufficient rejection of refractive index fluctuations caused by variation in temperature, solvent concentration, and most prominently, non-specific binding.…
▽ More
Diffractometric biosensing is a promising technology to overcome critical limitations of refractometric biosensors, the dominant class of label-free optical transducers. These limitations manifest themselves by higher noise and drifts due to insufficient rejection of refractive index fluctuations caused by variation in temperature, solvent concentration, and most prominently, non-specific binding. Diffractometric biosensors overcome these limitations with inherent self-referencing on the submicron scale with no compromise on resolution. Despite this highly promising attribute, the field of diffractometric biosensors has only received limited recognition. A major reason is the lack of a general quantitative analysis. This hinders comparison to other techniques and amongst different diffractometric biosensors. For refractometric biosensors, on the other hand, such a comparison is possible by means of the refractive index unit (RIU). In this publication, we suggest the coherent surface mass density, $Γ_{\rm{coh}}$, as a quantity for label-free diffractometric biosensors with the same purpose as RIU in refractometric sensors. It is easy to translate $Γ_{\rm{coh}}$ to the total surface mass density $Γ_{\rm{tot}}$, which is an important parameter for many assays. We provide a generalized framework to determine $Γ_{\rm{coh}}$ for various diffractometric biosensing arrangements which enables quantitative comparison. Additionally, the formalism can be used to estimate background scattering in order to further optimize sensor configurations. Finally, a practical guide with important experimental considerations is given to enable readers of any background to apply the theory. Therefore, this paper provides a powerful tool for the development of diffractometric biosensors and will help the field to mature and unveil its full potential.
△ Less
Submitted 30 November, 2020;
originally announced November 2020.
-
A promising approach for the real-time quantification of cytosolic protein-protein interactions in living cells
Authors:
Ilaria Incaviglia,
Andreas Frutiger,
Yves Blickenstorfer,
Fridolin Treindl,
Giulia Ammirati,
Ines Lüchtefeld,
Birgit Dreier,
Andreas Plückthun,
Janos Vörös,
Andreas M Reichmuth
Abstract:
In recent years, cell-based assays have been frequently used in molecular interaction analysis. Cell-based assays complement traditional biochemical and biophysical methods, as they allow for molecular interaction analysis, mode of action studies and even drug screening processes to be performed under physiologically relevant conditions. In most cellular assays, biomolecules are usually labeled to…
▽ More
In recent years, cell-based assays have been frequently used in molecular interaction analysis. Cell-based assays complement traditional biochemical and biophysical methods, as they allow for molecular interaction analysis, mode of action studies and even drug screening processes to be performed under physiologically relevant conditions. In most cellular assays, biomolecules are usually labeled to achieve specificity. In order to overcome some of the drawbacks associated with label-based assays, we have recently introduced cell-based molography as a biosensor for the analysis of specific molecular interactions involving native membrane receptors in living cells. Here, we expand this assay to cytosolic protein-protein interactions. First, we created a biomimetic membrane receptor by tethering one cytosolic interaction partner to the plasma membrane. The artificial construct is then coherently arranged into a two-dimensional pattern within the cytosol of living cells. Thanks to the molographic sensor, the specific interactions between the coherently arranged protein and its endogenous interaction partners become visible in real-time without the use of a fluorescent label. This method turns out to be an important extension of cell-based molography because it expands the range of interactions that can be analyzed by molography to those in the cytosol of living cells.
△ Less
Submitted 26 November, 2020;
originally announced November 2020.
-
Principles for sensitive and robust biomolecular interaction analysis - The limits of detection and resolution of diffraction-limited focal molography
Authors:
Andreas Frutiger,
Yves Blickenstorfer,
Silvio Bischof,
Csaba Forró,
Matthias Lauer,
Volker Gatterdam,
Christof Fattinger,
János Vörös
Abstract:
Label-free biosensors enable the monitoring of biomolecular interactions in real-time, which is key to the analysis of the binding characteristics of biomolecules. While refractometric optical biosensors are sensitive and well-established, they are susceptible to any change of the refractive index in the sensing volume caused by minute variations in composition of the sample buffer, temperature dr…
▽ More
Label-free biosensors enable the monitoring of biomolecular interactions in real-time, which is key to the analysis of the binding characteristics of biomolecules. While refractometric optical biosensors are sensitive and well-established, they are susceptible to any change of the refractive index in the sensing volume caused by minute variations in composition of the sample buffer, temperature drifts and nonspecific binding to the sensor surface. Refractometric biosensors require reference channels as well as temperature stabilisation and their applicability in complex fluids such as blood is limited by nonspecific bindings. Focal molography does not measure the refractive index of the entire sensing volume but detects the diffracted light from a coherent assembly of analyte molecules. Thus, it does not suffer from the limitations of refractometric sensors since they stem from non-coherent processes and therefore do not add to the coherent molographic signal. The coherent assembly is generated by selective binding of the analyte molecules to a synthetic binding pattern - the mologram. Focal Molography has been introduced theoretically and verified experimentally in previous papers. However, further understanding of the underlying physics and a diffraction-limited readout is needed to unveil its full potential. This paper introduces refined theoretical models which can accurately quantify the amount of matter bound to the mologram from the diffracted intensity. In addition, it presents measurements of diffraction-limited molographic foci. These improvements enabled us to demonstrate a resolution in real-time binding experiments comparable to the best SPR sensors, without the need of temperature stabilisation or drift correction and to detect small molecules label-free in an endpoint format. The presented experiments exemplify the robustness and sensitivity of diffractometric sensors.
△ Less
Submitted 27 August, 2018; v1 submitted 23 August, 2018;
originally announced August 2018.