Low-Dose TOF-PET Based on Surface Electron Production in Dielectric Laminar MCPs
Authors:
Kepler Domurat-Sousa,
Cameron Poe,
Henry J. Frisch,
Bernhard W. Adams,
Camden Ertley,
Neal Sullivan
Abstract:
We present simulations of whole-body low-dose time-of-flight positron emission tomography (TOF-PET) based on the direct surface production [1] by 511 keV gamma rays of energetic electrons via the Photo-electric and Compton Effects, eliminating the scintillator and photodetector sub-systems in PET scanners. In Ref. [1] we described Microchannel Plates (MCP) constructed from thin dielectric laminae…
▽ More
We present simulations of whole-body low-dose time-of-flight positron emission tomography (TOF-PET) based on the direct surface production [1] by 511 keV gamma rays of energetic electrons via the Photo-electric and Compton Effects, eliminating the scintillator and photodetector sub-systems in PET scanners. In Ref. [1] we described Microchannel Plates (MCP) constructed from thin dielectric laminae containing heavy nuclei such as lead or tungsten (LMCP$^{\rm{TM}}$). The laminae surfaces are micro-patterned to form channels, which can then be functionalized to support secondary electron emission in the manner of conventional MCPs.
We have simulated direct conversion using modifications to the TOPAS Geant4-based tool kit. A 20 $\times$ 20 $\times$ 2.54 cm$^3$ LMCP, composed of 150-micron thick lead-glass laminae, is predicted to have a $\ge 30$% conversion efficiency to a primary electron that penetrates an interior wall of a pore. The subsequent secondary electron shower is largely confined to one pore and can provide high space and time resolutions.
In whole-body PET scanners the technique eliminates the scintillator and photodetector subsystems. The consequent absence of a photocathode allows assembly of large arrays at atmospheric pressure and less stringent vacuum requirements, including use of pumped and cycled systems.
TOPAS simulations of the Derenzo and XCAT-brain phantoms are presented with dose reductions of factors of 100 and 1000 from a literature benchmark. New applications of PET at a significantly lower radiation dose include routine screening for early detection of pathologies, the use in diagnostics in previously unserved patient populations such as children, and a larger installed facility base in rural and under-served populations, where simpler gamma detectors and lower radiation doses may enable small low-cost portable PET scanners.
△ Less
Submitted 18 October, 2023; v1 submitted 5 July, 2023;
originally announced July 2023.
-
Surface Direct Conversion of 511 keV Gamma Rays in Large-Area Laminated Multichannel-Plate Electron Multipliers
Authors:
Kepler Domurat-Sousa,
Cameron Poe,
Henry J. Frisch,
Bernhard W. Adams,
Camden Ertley,
Neal Sullivan
Abstract:
We have used the TOPAS simulation framework to model the direct conversion of 511 keV gamma rays to electrons in a micro-channel plate (MCP) constructed from thin laminae of a heavy-metal-loaded dielectric such as lead-glass, patterned with micro-channels (LMCP). The laminae serve as the converter of the gamma ray to a primary electron within a depth from a channel-forming surface such that the el…
▽ More
We have used the TOPAS simulation framework to model the direct conversion of 511 keV gamma rays to electrons in a micro-channel plate (MCP) constructed from thin laminae of a heavy-metal-loaded dielectric such as lead-glass, patterned with micro-channels (LMCP). The laminae serve as the converter of the gamma ray to a primary electron within a depth from a channel-forming surface such that the electron penetrates the channel surface (`surface direct conversion'). The channels are coated with a secondary-emitting material to produce electron multiplication in the channels. The laminae are stacked on edge with the channels running from the top of the resulting `slab' to the bottom; after assembly the slab is metalized top and bottom to form the finished LMCP.
The shape of the perimeter of a lamina determines the dimensions of the slab at the lamina location in the slab, allowing non-uniform cross-sections in slab thickness, width, and length. The slab also can be non-planar, allowing curved surfaces in both lateral dimensions. The laminar construction allows incorporating structural elements in the LMCP for modular assembly in large-area arrays.
The channels can be patterned on the laminae surfaces with internal shapes and structure, texture, and coatings optimized for specific applications and performance. The channels can be non-uniform across the LMCP and need not be parallel in either transverse direction.
Surface direct conversion of the gamma ray to an electron eliminates the common two-step conversion of the gamma ray into an optical photon in a scintillator followed by the conversion of the photon into an electron in a photodetector. The simulations predict an efficiency for conversion of 511 keV gamma rays of $\gtrapprox$ 30\% for a 2.54 cm-thick lead-glass LMCP. The elimination of the photocathode allows assembly at atmospheric pressure.
△ Less
Submitted 21 July, 2023; v1 submitted 20 June, 2023;
originally announced June 2023.
-
Simulation of a Compton-based detector for low-dose high-resolution time-of-flight positron emission tomography
Authors:
Kepler Domurat-Sousa,
Cameron M. Poe,
Maya S. McDaniel,
Eric Spieglan,
Joao F. Shida,
Evan Angelico,
Bernhard W. Adams,
Patrick J. La Riviere,
Henry J. Frisch,
Allison H. Squires
Abstract:
Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental physics. A new type of TOF-PET detector employing low-atomic number (low-Z) scintillation media and large-area, high-resolution photodetectors to record Compton scatte…
▽ More
Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental physics. A new type of TOF-PET detector employing low-atomic number (low-Z) scintillation media and large-area, high-resolution photodetectors to record Compton scattering locations in the detector has been proposed as a promising alternative, but the minimum technical requirements for such a system have not yet been established. Here we present a simulation study evaluating the potential of a proposed low-Z detection medium, linear alkylbenzene (LAB) doped with a switchable molecular recorder, for next-generation TOF-PET detection. We developed a custom Monte Carlo simulation of full-body TOF-PET using the TOPAS Geant4 software package. By quantifying contributions and tradeoffs for energy, spatial, and timing resolution of the detector, we show that at reasonable combination of specifications, our likelihood-based identification of pairs of first interaction locations in the simulated detector identifies 87.1% of pairs with zero or negligible error, and correctly rejects 90% of all in-patient scatters. The same specifications give TOF-PET sensitivity of ~66.7% and PSF width 4.6 mm with clear contrast. A detector with these specifications provides a clear image of a brain phantom simulated at less than 1% of a standard radiotracer dose.
△ Less
Submitted 3 January, 2024; v1 submitted 11 May, 2023;
originally announced May 2023.
-
Adding Stroboscopic Muon Information For Reduction of Systematic Uncertainties in DUNE
Authors:
Henry J. Frisch
Abstract:
Muons have a similar latency/energy correlation from pion decay as do the neutrinos, and hence in each time-slice in a stroboscopic analysis measurements of their momentum spectra can reduce systematic uncertainties due to flux. There are, however, unique issues for muons: 1) during standard neutrino data-taking muon measurements in the forward direction must be in formidable high-flux high-radiat…
▽ More
Muons have a similar latency/energy correlation from pion decay as do the neutrinos, and hence in each time-slice in a stroboscopic analysis measurements of their momentum spectra can reduce systematic uncertainties due to flux. There are, however, unique issues for muons: 1) during standard neutrino data-taking muon measurements in the forward direction must be in formidable high-flux high-radiation environments; 2) because of the very high incident hadron flux in the Absorber Hall, muons must be detected after a thick absorber, imposing a range cutoff at a momentum much above the minimum neutrino momentum of interest; 3) the muon velocity, unlike that of neutrinos, differs from $c$, and so the muon detected time will require correction for the muon flight path, requiring measurement of the muon momentum; 4) multiple scattering is significant for low-momentum muons, and so a `good geometry' is essential for precision muon flux measurements; and 5) developments in psec timing allow muon momenta in the momentum region of interest to be measured precisely by time-of-flight over short distances with photodetectors of a few-psec resolution. Here we advocate that a program of extensive precise low-intensity muon momentum spectrum measurements be carried out early in the LBNF program before the Absorber Hall becomes too hot. The low-momentum muon spectra taken in this experiment would be cross-normalized to the high-intensity neutrino data through the currently planned muon monitors which can operate in both the low and high intensity geometries.
While beyond the scope of uniquely muon-related issues, the note includes a proposal for an long-base-line oscillation analysis strategy that exploits stroboscopic information for both neutrinos and muons to reduce systematic uncertainties on the neutrino fluxes and event selection in Far and Near detectors.
△ Less
Submitted 16 December, 2022;
originally announced December 2022.
-
Low-Dose High-Resolution TOF-PET Using Ionization-activated Multi-State Low-Z Detector Media
Authors:
Joao Francisco Shida,
Eric Spieglan,
Bernhard W. Adams,
Evan Angelico,
Kepler Domurat-Sousa,
Andrey Elagin,
Henry J. Frisch,
Patrick La Riviere,
Allison H. Squires
Abstract:
We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatter…
▽ More
We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a `Switchillator', that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.
△ Less
Submitted 3 August, 2021;
originally announced August 2021.
-
Segmented Anodes with Sub-millimeter Spatial Resolution for MCP-Based Photodetectors
Authors:
**seo Park,
Fangjian Wu,
Evan Angelico,
Henry J. Frisch,
Eric Spieglan
Abstract:
Micro-channel-plate-based photo-detectors are unique in being capable of covering areas of many square-meters while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, time resolutions of 30-50 psec for single photons. Incorporating a capacitively-coupled anode allows for the use of external pickup electrodes optimized for occupancy, rate,…
▽ More
Micro-channel-plate-based photo-detectors are unique in being capable of covering areas of many square-meters while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, time resolutions of 30-50 psec for single photons. Incorporating a capacitively-coupled anode allows for the use of external pickup electrodes optimized for occupancy, rate, and time/space resolution. The signal pickup antenna can be implemented as a printed circuit card with a pattern chosen to match the specific application needs. The electrode elements are typically either a 2-dimensional array of pads for high-occupancy/high-rate applications, or a 1-dimensional array of strips for low-occupancy/low-rate, and a lower channel count. Here we present pad patterns that enhance charge-sharing between pads to significantly lower the required channel count/area while maintaining spatial resolutions of 100 to 200 microns for charged particles and 400 microns to 1 mm for single photons. Patterns that use multiple signal layers in the capacitively-coupled printed circuit signal pickup board can lower the channel count even further, moving the scaling behavior in the number of pads versus total area from quadratic to linear.
△ Less
Submitted 17 July, 2020; v1 submitted 15 July, 2020;
originally announced July 2020.
-
Measuring the Neutrino Event Time in Liquid Argon by a Post-Reconstruction One-parameter Fit
Authors:
Evan Angelico,
Andrey Elagin,
Henry J. Frisch,
Matthew Wetstein
Abstract:
We propose a relatively simple method to measure the event time in liquid Argon (LAr) TPC-based neutrino detectors that takes advantage of the topological reconstruction of each event from the TPC data prior to performing a one-parameter fit. Measured times and positions of detected photons are fit to the expected pattern of light from the tracks as reconstructed using the electron drift. The even…
▽ More
We propose a relatively simple method to measure the event time in liquid Argon (LAr) TPC-based neutrino detectors that takes advantage of the topological reconstruction of each event from the TPC data prior to performing a one-parameter fit. Measured times and positions of detected photons are fit to the expected pattern of light from the tracks as reconstructed using the electron drift. The event can be treated as a rigid body with only the neutrino interaction time as a free parameter. The optical properties of LAr are comparable to those of water for Cherenkov light in visible wavelengths. Data-Monte Carlo comparisons of the light patterns, given the known track topology from electron drift, enable in situ calibration of the optical model and further optimization of the timing. A back-of-the-envelope calculation predicts that the single parameter fit for the interaction time requires a significantly lower photodetector coverage than needed for the same precision in conventional warm-liquid detectors.
△ Less
Submitted 1 April, 2020;
originally announced April 2020.
-
Air-Transfer Production Method for Large-Area Picosecond Photodetectors
Authors:
E. Angelico,
A. Elagin,
H. J. Frisch,
E. Spieglan,
B. W. Adams,
M. R. Foley,
M. J. Minot
Abstract:
We have designed and prototyped the process steps for the batch production of large-area micro-channel-plate photomultipliers (MCP-PMT) using the "air-transfer" assembly process developed with single $LAPPD^{\text{TM}}$ modules. Results are presented addressing the challenges of designing a robust package that can transmit large numbers of electrical signals for pad or strip readout from inside th…
▽ More
We have designed and prototyped the process steps for the batch production of large-area micro-channel-plate photomultipliers (MCP-PMT) using the "air-transfer" assembly process developed with single $LAPPD^{\text{TM}}$ modules. Results are presented addressing the challenges of designing a robust package that can transmit large numbers of electrical signals for pad or strip readout from inside the vacuum tube and hermetically sealing the large-perimeter window-body interface. We have also synthesized a photocathode in a large-area low-aspect-ratio volume, and shown that the micro-channel plates recover their functionality after cathode synthesis. The steps inform a design for a multi-module batch facility employing dual nested low-vacuum (LV) and ultra-high-vacuum (UHV) systems in a small-footprint. The facility design provides full access to multiple MCP-PMT modules prior to hermetic pinch-off for leak-checking and real-time photocathode optimization.
△ Less
Submitted 13 March, 2020;
originally announced March 2020.
-
Performance of Large Area Picosecond Photo-Detectors (LAPPD)
Authors:
A. V. Lyashenko,
B. W. Adams,
M. Aviles,
T. Cremer,
C. D. Ertley,
M. R. Foley,
M. J. Minot,
M. A. Popecki,
M. E. Stochaj,
W. A. Worstell,
J. W. Elam,
A. U. Mane,
O. H. W. Siegmund,
H. J. Frisch,
A. L. Elagin,
E. Angelico,
E. Spieglan
Abstract:
We report on performance results achieved for recently produced LAPPDs - largest comercially available planar geometry photodetectors based on microchannel plates. These results include electron gains of up to $10^{7}$, low dark noise rates ($\sim$100 Hz/cm$^{2}$ at a gain of $6\cdot10^6$), single photoelectron (PE) timing resolution of $\sim$50 picoseconds RMS (electronics limited), and single ph…
▽ More
We report on performance results achieved for recently produced LAPPDs - largest comercially available planar geometry photodetectors based on microchannel plates. These results include electron gains of up to $10^{7}$, low dark noise rates ($\sim$100 Hz/cm$^{2}$ at a gain of $6\cdot10^6$), single photoelectron (PE) timing resolution of $\sim$50 picoseconds RMS (electronics limited), and single photoelectron spatial resolution along and across strips of 3.2mm (electronics limited) and 0.8 mm RMS respectively and high (about 25\% or higher in some units) QE uniform bi-alkali photocathodes. LAPPDs is a good candidate to be employed in neutrino experiments (e.g. ANNIE, WATCHMAN, DUNE), particle collider experiments (e.g. EIC), neutrinoless double-beta decay experiments (e.g. THEIA), medical and nuclear non-proliferation applications.
△ Less
Submitted 23 September, 2019;
originally announced September 2019.
-
Pisa and the Collider Detector at Fermilab: a History of the Establishment of Precision Physics With a Calorimetric Spectrometer at a Hadron Collider
Authors:
Henry J. Frisch
Abstract:
This is a personal and admittedly US-centric attempt to summarize the foundational impact of the Pisa CDF Group on the conceptual design, construction, and early operation of the CDF Detector at Fermilab. I have tried to go back to original documents where possible.
This is a personal and admittedly US-centric attempt to summarize the foundational impact of the Pisa CDF Group on the conceptual design, construction, and early operation of the CDF Detector at Fermilab. I have tried to go back to original documents where possible.
△ Less
Submitted 13 August, 2018;
originally announced August 2018.
-
Drifting Photons on Optical Paths: Mirrors, Sub-mm Resolution in 4 Dimensions, and Transverse/Longitudinal Phase Space: Exploiting Time Resolution
Authors:
Henry J. Frisch
Abstract:
I discuss the status of MCP-based photo-detector amplification sections and Cherenkov light sources for precise timing measurements of charged particles and gamma rays. Sub-psec resolution is predicted for the large pulses such as those produced by a charged particle or electromagnetic shower traversing a photo-detector entrance window. Measuring events with sub-mm resolution in each of the 4 dime…
▽ More
I discuss the status of MCP-based photo-detector amplification sections and Cherenkov light sources for precise timing measurements of charged particles and gamma rays. Sub-psec resolution is predicted for the large pulses such as those produced by a charged particle or electromagnetic shower traversing a photo-detector entrance window. Measuring events with sub-mm resolution in each of the 4 dimensions expands the optical phase space from 4 dimensions, allowing emittance transformations that can minimize expensive instrumented photo-sensitive area.
△ Less
Submitted 13 July, 2018;
originally announced July 2018.
-
A Modular Data Acquisition System using the 10 GSa/s PSEC4 Waveform Recording Chip
Authors:
M. Bogdan,
E. Oberla,
H. J. Frisch,
M. Wetstein
Abstract:
We describe a modular multi-channel data acquisition system based on the 5-15 Gigasample-per-second waveform-recording PSEC4 chip. The system architecture incorporates two levels of hardware with FPGA-embedded system control and in-line data processing. The front-end unit is a 30-channel circuit board that holds five PSEC4 ASICs, a clock jitter cleaner, and a control FPGA. The analog bandwidth of…
▽ More
We describe a modular multi-channel data acquisition system based on the 5-15 Gigasample-per-second waveform-recording PSEC4 chip. The system architecture incorporates two levels of hardware with FPGA-embedded system control and in-line data processing. The front-end unit is a 30-channel circuit board that holds five PSEC4 ASICs, a clock jitter cleaner, and a control FPGA. The analog bandwidth of the front-end signal path is 1.5 GHz. Each channel has an on-chip threshold-level discriminator that is monitored in the FPGA, from which a flexible on-board trigger decision can be formed. To instrument larger channel counts, a `back-end' 6U VME32 control card has been designed. Called the 'Central Card', it incorporates an Altera Arria-V FPGA that manages up to 8 front-end cards using one or two CAT5 network cables per board, which transmits the clock and communicates data packets over a custom serial protocol. Data can be read from the Central Card via USB, Ethernet, or dual SFP links, in addition to the VME interface. The Central Card can be configured as either Master or Slave, allowing one Master to receive data from up to 8 Slaves, with each Slave managing 8 30-channel front-end cards, allowing a single VME crate to control up to 1920 channels of the PSEC4 chip.
△ Less
Submitted 8 July, 2016;
originally announced July 2016.
-
A Brief Technical History of the Large-Area Picosecond Photodetector (LAPPD) Collaboration
Authors:
Bernhard W. Adams,
Klaus Attenkofer,
Mircea Bogdan,
Karen Byrum,
Andrey Elagin,
Jeffrey W. Elam,
Henry J. Frisch,
Jean-Francois Genat,
Herve Grabas,
Joseph Gregar,
Elaine Hahn,
Mary Heintz,
Zinetula Insepov,
Valentin Ivanov,
Sharon Jelinsky,
Slade Jokely,
Sun Wu Lee,
Anil. U. Mane,
Jason McPhate,
Michael J. Minot,
Pavel Murat,
Kurtis Nishimura,
Richard Northrop,
Razib Obaid,
Eric Oberla
, et al. (16 additional authors not shown)
Abstract:
The Large Area Picosecond PhotoDetector (LAPPD) Collaboration was formed in 2009 to develop large-area photodetectors capable of time resolutions measured in pico-seconds, with accompanying sub-millimeter spatial resolution. During the next three and one-half years the Collaboration developed the LAPPD design of 20 x 20 cm modules with gains greater than $10^7$ and non-uniformity less than $15\%$,…
▽ More
The Large Area Picosecond PhotoDetector (LAPPD) Collaboration was formed in 2009 to develop large-area photodetectors capable of time resolutions measured in pico-seconds, with accompanying sub-millimeter spatial resolution. During the next three and one-half years the Collaboration developed the LAPPD design of 20 x 20 cm modules with gains greater than $10^7$ and non-uniformity less than $15\%$, time resolution less than 50 psec for single photons and spatial resolution of 700~microns in both lateral dimensions. We describe the R\&D performed to develop large-area micro-channel plate glass substrates, resistive and secondary-emitting coatings, large-area bialkali photocathodes, and RF-capable hermetic packaging. In addition, the Collaboration developed the necessary electronics for large systems capable of precise timing, built up from a custom low-power 15-GigaSample/sec waveform sampling 6-channel integrated circuit and supported by a two-level modular data acquisition system based on Field-Programmable Gate Arrays for local control, data-sparcification, and triggering. We discuss the formation, organization, and technical successes and short-comings of the Collaboration. The Collaboration ended in December 2012 with a transition from R\&D to commercialization.
△ Less
Submitted 6 March, 2016;
originally announced March 2016.
-
The design and performance of a prototype water Cherenkov optical time-projection chamber
Authors:
E. Oberla,
H. J. Frisch
Abstract:
A first experimental test of tracking relativistic charged particles by `drifting' Cherenkov photons in a water-based optical time-projection chamber (OTPC) has been performed at the Fermilab Test Beam Facility. The prototype OTPC detector consists of a 77~cm long, 28~cm diameter, 40~kg cylindrical water mass instrumented with a combination of commercial $5.1\times5.1$~cm$^2$ micro-channel plate p…
▽ More
A first experimental test of tracking relativistic charged particles by `drifting' Cherenkov photons in a water-based optical time-projection chamber (OTPC) has been performed at the Fermilab Test Beam Facility. The prototype OTPC detector consists of a 77~cm long, 28~cm diameter, 40~kg cylindrical water mass instrumented with a combination of commercial $5.1\times5.1$~cm$^2$ micro-channel plate photo-multipliers (MCP-PMT) and $6.7\times6.7$~cm$^2$ mirrors. Five MCP-PMTs are installed in two columns along the OTPC cylinder in a small-angle stereo configuration. A mirror is mounted opposite each MCP-PMT on the far side of the detector cylinder, effectively doubling the photo-detection efficiency and providing a time-resolved image of the Cherenkov light on the opposing wall. Each MCP-PMT is coupled to an anode readout consisting of thirty 50 Ohm microstrips. A 180-channel data acquisition system digitizes the MCP-PMT signals on one end of the microstrips using the PSEC4 waveform sampling-and-digitizing chip operating at a sampling rate of 10.24~Gigasamples-per-second. The single-ended microstrip readout determines the time and position of a photon arrival at the face of the MCP-PMT by recording both the direct signal and the pulse reflected from the unterminated far end of the strip. The detector was installed on the Fermilab MCenter secondary beam-line behind a steel absorber where the primary flux is multi-GeV muons. Approximately 80 Cherenkov photons are detected for a through-going muon track in a total event duration of ~2 ns. By measuring the time-of-arrival and the position of individual photons at the surface of the detector to $\le$100~ps and a few mm, respectively, we have measured a spatial resolution of $\sim$ 15~mm for each MCP-PMT track segment, and, from linear fits over the entire track length of $\sim40$~cm, an angular resolution on the track direction of $\sim60$~mrad.
△ Less
Submitted 4 October, 2015;
originally announced October 2015.
-
Measuring Directionality in Double-Beta Decay and Neutrino Interactions with Kiloton-Scale Scintillation Detectors
Authors:
C. Aberle,
A. Elagin,
H. J. Frisch,
M. Wetstein,
L. Winslow
Abstract:
Large liquid-scintillator-based detectors have proven to be exceptionally effective for low energy neutrino measurements due to their good energy resolution and scalability to large volumes. The addition of directional information using Cherenkov light and fast timing would enhance the scientific reach of these detectors, especially for searches for neutrino-less double-beta decay. In this paper,…
▽ More
Large liquid-scintillator-based detectors have proven to be exceptionally effective for low energy neutrino measurements due to their good energy resolution and scalability to large volumes. The addition of directional information using Cherenkov light and fast timing would enhance the scientific reach of these detectors, especially for searches for neutrino-less double-beta decay. In this paper, we develop a technique for extracting particle direction using the difference in arrival times for Cherenkov and scintillation light, and evaluate several detector advances in timing, photodetector spectral response, and scintillator emission spectra that could be used to make direction reconstruction a reality in a kiloton-scale detector.
△ Less
Submitted 30 January, 2014; v1 submitted 22 July, 2013;
originally announced July 2013.
-
Present Limits on the Precision of SM Predictions for Jet Energies
Authors:
A. A. Paramonov,
F. Canelli,
M. D'Onofrio,
H. J. Frisch,
S. Mrenna
Abstract:
We investigate the impact of theoretical uncertainties on the accuracy of measurements involving hadronic jets. The analysis is performed using events with a Z boson and a single jet observed in $p\bar{p}$ collisions at $\sqrt{s}$ = 1.96 TeV in 4.6 $\mathrm{fb^{-1}}$ of data from the Collider Detector at Fermilab (CDF). The transverse momenta (\pt) of the jet and the boson should balance each othe…
▽ More
We investigate the impact of theoretical uncertainties on the accuracy of measurements involving hadronic jets. The analysis is performed using events with a Z boson and a single jet observed in $p\bar{p}$ collisions at $\sqrt{s}$ = 1.96 TeV in 4.6 $\mathrm{fb^{-1}}$ of data from the Collider Detector at Fermilab (CDF). The transverse momenta (\pt) of the jet and the boson should balance each other due to momentum conservation in the plane transverse to the direction of the $p$ and $\bar{p}$ beams. We evaluate the dependence of the measured \pt-balance on theoretical uncertainties associated with initial and final state radiation, choice of renormalization and factorization scales, parton distribution functions, jet-parton matching, calculations of matrix elements, and parton showering. We find that the uncertainty caused by parton showering at large angles is the largest amongst the listed uncertainties. The proposed method can be re-applied at the LHC experiments to investigate and evaluate the uncertainties on the predicted jet energies. The distributions produced at the CDF environment are intended for comparison to those from modern event generators and new tunes of parton showering.
△ Less
Submitted 2 August, 2010;
originally announced August 2010.
-
Perspectives on Supersymmetry: The Search for Supersymmetry at the Tevatron Collider
Authors:
M. Carena,
R. L. Culbertson,
S. Eno,
H. J. Frisch,
S. Mrenna
Abstract:
A review of the status of searches for Supersymmetry at the Tevatron Collider as of the Summer of 1997. This is a new version of the previous review, substantially shortened to fit editorial guidelines, and significantly different to warrant a separate posting. To appear in "Perspectives on Supersymmetry", ed. G.L. Kane (World Scientific, Singapore).
A review of the status of searches for Supersymmetry at the Tevatron Collider as of the Summer of 1997. This is a new version of the previous review, substantially shortened to fit editorial guidelines, and significantly different to warrant a separate posting. To appear in "Perspectives on Supersymmetry", ed. G.L. Kane (World Scientific, Singapore).
△ Less
Submitted 4 February, 1998; v1 submitted 3 February, 1998;
originally announced February 1998.
-
The Search for Supersymmetry at the Tevatron Collider
Authors:
M. Carena,
R. L. Culbertson,
S. Eno,
H. J. Frisch,
S. Mrenna
Abstract:
We review the status of searches for Supersymmetry at the Tevatron Collider. After discussing the theoretical aspects relevant to the production and decay of supersymmetric particles at the Tevatron, we present the current results for Runs Ia and Ib as of the summer of 1997. To appear in the book "Perspectives in Supersymmetry", edited by G.L. Kane, World Scientific.
We review the status of searches for Supersymmetry at the Tevatron Collider. After discussing the theoretical aspects relevant to the production and decay of supersymmetric particles at the Tevatron, we present the current results for Runs Ia and Ib as of the summer of 1997. To appear in the book "Perspectives in Supersymmetry", edited by G.L. Kane, World Scientific.
△ Less
Submitted 17 December, 1997;
originally announced December 1997.