-
Thermal and mechanical study of a parametrised cryostat model for optical characterisation of upcoming CMB experiments
Authors:
Thomas J. L. J. Gascard,
Yi Wang,
Jon E. Gudmundsson,
Eve M. Vavagiakis,
Cody J. Duell,
Zachary B. Huber,
Lawrence T. Lin,
Michael D. Niemack,
Rodrigo G. Freundt
Abstract:
Current and future experiments observing the cosmic microwave background require a detailed understanding of optical performance at cryogenic temperatures. Pre-deployment analysis of optics can be performed in custom-engineered cryogenic test beds, such as Mod-Cam, a first light camera for the CCAT project. This work presents studies of the mechanical and thermal performance of CryoSim, a model of…
▽ More
Current and future experiments observing the cosmic microwave background require a detailed understanding of optical performance at cryogenic temperatures. Pre-deployment analysis of optics can be performed in custom-engineered cryogenic test beds, such as Mod-Cam, a first light camera for the CCAT project. This work presents studies of the mechanical and thermal performance of CryoSim, a model of a generic cylindrical 4-K cryostat cooled with a commercial pulse tube cryocooler that can be used to characterise optical components and full reimaging optical systems. CryoSim is extensively parametrised, allowing the joint analysis and optimisation of mechanical and thermal performance via finite element methods. Results from this model are validated against measured cooldown data of the Mod-Cam cryostat. Due to the extensive parametrisation of the model, significant modifications of the cryostat geometry may be implemented to be representative of any system the scientific community may desire, and validation of thermal and mechanical performance can be carried out rapidly.
△ Less
Submitted 5 July, 2024;
originally announced July 2024.
-
CCAT: Comparisons of 280 GHz TiN and Al Kinetic Inductance Detector Arrays
Authors:
Cody J. Duell,
Jason Austermann,
James Beall,
James R. Burgoyne,
Scott C. Chapman,
Steve K. Choi,
Rodrigo G. Freundt,
Jiansong Gao,
Christopher Groppi,
Anthony I. Huber,
Zachary B. Huber,
Johannes Hubmayr,
Ben Keller,
Yaqiong Li,
Lawrence T. Lin,
Justin Matthewson,
Philip Mauskopf,
Alicia Middleton,
Colin C. Murphy,
Michael D. Niemack,
Thomas Nikola,
Adrian K. Sinclair,
Ema Smith,
Jeff van Lanen,
Anna Vaskuri
, et al. (5 additional authors not shown)
Abstract:
The CCAT Collaboration's six-meter Fred Young Submillimeter Telescope is scheduled to begin observing in the Chilean Atacama in 2025, targeting a variety of science goals throughout cosmic history. Prime-Cam is a 1.8-meter diameter cryostat that will host up to seven independent instrument modules designed for simultaneous spectroscopic and broadband, polarimetric surveys at millimeter to submilli…
▽ More
The CCAT Collaboration's six-meter Fred Young Submillimeter Telescope is scheduled to begin observing in the Chilean Atacama in 2025, targeting a variety of science goals throughout cosmic history. Prime-Cam is a 1.8-meter diameter cryostat that will host up to seven independent instrument modules designed for simultaneous spectroscopic and broadband, polarimetric surveys at millimeter to submillimeter wavelengths. The first of these instrument modules, the 280 GHz module, will include ${\sim}$10,000 kinetic inductance detectors (KIDs) across three arrays. While the first array was fabricated out of tri-layer TiN/Ti/TiN, the other two arrays were fabricated out of a single layer of Al. This combination of materials within the same instrument provides a unique opportunity to directly compare the performance and noise properties of two different detector materials that are seeing increasing use within the field. We present preliminary comparisons here based on lab testing, along with a discussion of the potential impacts on operation when observing and translating raw data to science-grade maps.
△ Less
Submitted 10 June, 2024;
originally announced June 2024.
-
CCAT-prime: The Optical Design for the Epoch of Reionization Spectrometer
Authors:
Zachary B. Huber,
Steve K. Choi,
Cody J. Duell,
Rodrigo G. Freundt,
Patricio A. Gallardo,
Ben Keller,
Yaqiong Li,
Lawrence T. Lin,
Michael D. Niemack,
Thomas Nikola,
Dominik A. Riechers,
Gordon Stacey,
Eve M. Vavagiakis,
Bugao Zou
Abstract:
The Epoch of Reionization Spectrometer (EoR-Spec) will be an instrument module for the Prime-Cam receiver on the CCAT-prime Collaboration's Fred Young Submillimeter Telescope (FYST), a 6-m primary mirror Crossed Dragone telescope. With its Fabry-Perot interferometer (FPI), EoR-Spec will step through frequencies between 210 and 420 GHz to perform line intensity map** of the 158 $μ$m [CII] line in…
▽ More
The Epoch of Reionization Spectrometer (EoR-Spec) will be an instrument module for the Prime-Cam receiver on the CCAT-prime Collaboration's Fred Young Submillimeter Telescope (FYST), a 6-m primary mirror Crossed Dragone telescope. With its Fabry-Perot interferometer (FPI), EoR-Spec will step through frequencies between 210 and 420 GHz to perform line intensity map** of the 158 $μ$m [CII] line in aggregates of star-forming galaxies between redshifts of 3.5 and 8 to trace the evolution of structure in the universe during the epoch of reionization. Here we present the optical design of the module including studies of the optical quality and other key parameters at the image surface. In order to achieve the required resolving power (R$\sim$100) with the FPI, it is important to have a highly collimated beam at the Lyot stop of the system; the optimization process to achieve this goal with four lenses instead of three as used in other Prime-Cam modules is outlined. As part of the optimization, we test the effect of replacing some of the aspheric lenses with biconic lenses in this Crossed Dragone design and find that the biconic lenses tend to improve the image quality across the focal plane of the module.
△ Less
Submitted 19 August, 2022;
originally announced August 2022.
-
CCAT-prime: Design of the Mod-Cam receiver and 280 GHz MKID instrument module
Authors:
Eve M. Vavagiakis,
Cody J. Duell,
Jason Austermann,
James Beall,
Tanay Bhandarkar,
Scott C. Chapman,
Steve K. Choi,
Gabriele Coppi,
Simon Dicker,
Mark Devlin,
Rodrigo G. Freundt,
Jiansong Gao,
Christopher Groppi,
Terry L. Herter,
Zachary B. Huber,
Johannes Hubmayr,
Doug Johnstone,
Ben Keller,
Anna M. Kofman,
Yaqiong Li,
Philip Mauskopf,
Jeff McMahon,
Jenna Moore,
Colin C. Murphy,
Michael D. Niemack
, et al. (11 additional authors not shown)
Abstract:
Mod-Cam is a first light and commissioning instrument for the CCAT-prime project's six-meter aperture Fred Young Submillimeter Telescope (FYST), currently under construction at 5600 m on Cerro Chajnantor in Chile's Atacama Desert. Prime-Cam, a first-generation science instrument for FYST, will deliver over ten times greater map** speed than current and near-term facilities for unprecedented 280-…
▽ More
Mod-Cam is a first light and commissioning instrument for the CCAT-prime project's six-meter aperture Fred Young Submillimeter Telescope (FYST), currently under construction at 5600 m on Cerro Chajnantor in Chile's Atacama Desert. Prime-Cam, a first-generation science instrument for FYST, will deliver over ten times greater map** speed than current and near-term facilities for unprecedented 280-850 GHz broadband and spectroscopic measurements with microwave kinetic inductance detectors (MKIDs). CCAT-prime will address a suite of science goals, from Big Bang cosmology to star formation and galaxy evolution over cosmic time. Mod-Cam deployment on FYST with a 280 GHz instrument module containing MKID arrays is planned for early science observations in 2024. Mod-Cam will be used to test instrument modules for Prime-Cam, which can house up to seven instrument modules. We discuss the design and status of the 0.9 m diameter, 1.8 m long Mod-Cam receiver and 40 cm diameter 280 GHz instrument module, with cold stages at 40 K, 4 K, 1 K, and 100 mK. We also describe the instrument module's cryogenic readout designs to enable the readout of more than 10,000 MKIDs across 18 networks.
△ Less
Submitted 10 August, 2022;
originally announced August 2022.
-
CCAT-prime: Characterization of the First 280 GHz MKID Array for Prime-Cam
Authors:
Steve K. Choi,
Cody J. Duell,
Jason Austermann,
Nicholas F. Cothard,
Jiansong Gao,
Rodrigo G. Freundt,
Christopher Groppi,
Terry Herter,
Johannes Hubmayr,
Zachary B. Huber,
Ben Keller,
Yaqiong Li,
Phillip Mauskopf,
Michael D. Niemack,
Thomas Nikola,
Kayla Rossi,
Adrian Sinclair,
Gordon J. Stacey,
Eve M. Vavagiakis,
Michael Vissers,
Carole Tucker,
Eric Weeks,
Jordan Wheeler
Abstract:
The Prime-Cam receiver on the Fred Young Submillimeter Telescope for the CCAT-prime project aims to address important astrophysical and cosmological questions with sensitive broadband, polarimetric, and spectroscopic measurements. The primary frequency bands in development include 280, 350, and 850 GHz for the polarization-sensitive broadband channels and 210--420 GHz for the spectrometers. Microw…
▽ More
The Prime-Cam receiver on the Fred Young Submillimeter Telescope for the CCAT-prime project aims to address important astrophysical and cosmological questions with sensitive broadband, polarimetric, and spectroscopic measurements. The primary frequency bands in development include 280, 350, and 850 GHz for the polarization-sensitive broadband channels and 210--420 GHz for the spectrometers. Microwave kinetic inductance detectors (MKIDs) are a natural choice of detector technology for the simplicity in multiplexed readout needed for large format arrays at these high frequencies. We present here the initial lab characterization of the feedhorn-coupled 280 GHz polarimetric MKID array, and outline the plans for the subsequent MKID arrays and the development of the testbed to characterize them.
△ Less
Submitted 10 August, 2022; v1 submitted 1 November, 2021;
originally announced November 2021.