-
Dual recycling for GEO600
Authors:
A. Freise
Abstract:
Dual recycling is the combination of signal recycling and power recycling; both optical techniques improve the shot-noise-limited sensitivity of interferometric gravitational-wave detectors. In addition, signal recycling can reduce the loss of light power due to imperfect interference and allows, in principle, to beat the standard quantum limit. The interferometric gravitational-wave detector GE…
▽ More
Dual recycling is the combination of signal recycling and power recycling; both optical techniques improve the shot-noise-limited sensitivity of interferometric gravitational-wave detectors. In addition, signal recycling can reduce the loss of light power due to imperfect interference and allows, in principle, to beat the standard quantum limit. The interferometric gravitational-wave detector GEO600 is the first detector to use signal recycling. We have recently equipped the detector with a signal-recycling mirror with a transmittance of 1%. In this paper, we present details of the detector commissioning and the first locks of the dual- recycled interferometer.
△ Less
Submitted 12 June, 2003;
originally announced June 2003.
-
Performance of a 1200m long suspended Fabry-Perot cavity
Authors:
A. Freise,
M. M. Casey,
S. Gossler,
H. Grote,
G. Heinzel,
H. Lueck,
D. I. Robertson,
K. A. Strain,
H. Ward,
B. Willke,
J. Hough,
K. Danzmann
Abstract:
Using one arm of the Michelson interferometer and the power recycling mirror of the interferometric gravitational wave detector GEO600, we created a Fabry-Perot cavity with a length of 1200 m. The main purpose of this experiment was to gather first experience with the main optics, its suspensions and the corresponding control systems. The residual displacement of a main mirror is about 150 nm rm…
▽ More
Using one arm of the Michelson interferometer and the power recycling mirror of the interferometric gravitational wave detector GEO600, we created a Fabry-Perot cavity with a length of 1200 m. The main purpose of this experiment was to gather first experience with the main optics, its suspensions and the corresponding control systems. The residual displacement of a main mirror is about 150 nm rms. By stabilising the length of the 1200 m long cavity to the pre-stabilised laser beam we achieved an error point frequency noise of 0.1 mHz/sqrt(Hz) at 100 Hz Fourier frequency. In addition we demonstrated the reliable performance of all included subsystems by several 10-hour-periods of continuous stable operation. Thus the full frequency stabilisation scheme for GEO600 was successfully tested.
△ Less
Submitted 5 November, 2001; v1 submitted 2 October, 2001;
originally announced October 2001.
-
Demonstration of detuned dual recycling at the Garching 30m laser interferometer
Authors:
A. Freise,
G. Heinzel,
K. A. Strain,
J. Mizuno,
K. D. Skeldon,
H. Lueck,
B. Willke,
R. Schilling,
A. Ruediger,
W. Winkler,
K. Danzmann
Abstract:
Dual recycling is an advanced optical technique to enhance the signal-to-noise ratio of laser interferometric gravitational wave detectors in a limited bandwidth. To optimise the center of this band with respect to Fourier frequencies of expected gravitational wave signals detuned dual recycling has to be implemented. We demonstrated detuned dual recycling on a fully suspended 30m prototype inte…
▽ More
Dual recycling is an advanced optical technique to enhance the signal-to-noise ratio of laser interferometric gravitational wave detectors in a limited bandwidth. To optimise the center of this band with respect to Fourier frequencies of expected gravitational wave signals detuned dual recycling has to be implemented. We demonstrated detuned dual recycling on a fully suspended 30m prototype interferometer. A control scheme that allows to tune the detector to different frequencies will be outlined. Good agreement between the experimental results and numerical simulations has been achieved.
△ Less
Submitted 19 October, 2000; v1 submitted 7 June, 2000;
originally announced June 2000.