AI-Driven CT-based quantification, staging and short-term outcome prediction of COVID-19 pneumonia
Authors:
Guillaume Chassagnon,
Maria Vakalopoulou,
Enzo Battistella,
Stergios Christodoulidis,
Trieu-Nghi Hoang-Thi,
Severine Dangeard,
Eric Deutsch,
Fabrice Andre,
Enora Guillo,
Nara Halm,
Stefany El Hajj,
Florian Bompard,
Sophie Neveu,
Chahinez Hani,
Ines Saab,
Alienor Campredon,
Hasmik Koulakian,
Souhail Bennani,
Gael Freche,
Aurelien Lombard,
Laure Fournier,
Hippolyte Monnier,
Teodor Grand,
Jules Gregory,
Antoine Khalil
, et al. (6 additional authors not shown)
Abstract:
Chest computed tomography (CT) is widely used for the management of Coronavirus disease 2019 (COVID-19) pneumonia because of its availability and rapidity. The standard of reference for confirming COVID-19 relies on microbiological tests but these tests might not be available in an emergency setting and their results are not immediately available, contrary to CT. In addition to its role for early…
▽ More
Chest computed tomography (CT) is widely used for the management of Coronavirus disease 2019 (COVID-19) pneumonia because of its availability and rapidity. The standard of reference for confirming COVID-19 relies on microbiological tests but these tests might not be available in an emergency setting and their results are not immediately available, contrary to CT. In addition to its role for early diagnosis, CT has a prognostic role by allowing visually evaluating the extent of COVID-19 lung abnormalities. The objective of this study is to address prediction of short-term outcomes, especially need for mechanical ventilation. In this multi-centric study, we propose an end-to-end artificial intelligence solution for automatic quantification and prognosis assessment by combining automatic CT delineation of lung disease meeting performance of experts and data-driven identification of biomarkers for its prognosis. AI-driven combination of variables with CT-based biomarkers offers perspectives for optimal patient management given the shortage of intensive care beds and ventilators.
△ Less
Submitted 20 April, 2020;
originally announced April 2020.
Design and test of a compact and high-resolution time-of-flight measurement device for cold neutron beams
Authors:
Damien Roulier,
Valery Nesvizhevsky,
Benoît Clément,
Guilhem Freche,
Guillaume Pignol,
Dominique Rebreyend,
Francis Vezzu,
Stefan Baeßler,
Alexander Strelkov
Abstract:
A time-of-flight device was developed to characterize wavelength distribution and uniformity of a cold neutron beam. This device is very compact -- the distance of flight is $60$ cm -- but achieves very high resolution -- the intrinsic resolution $Δλ/λ=2.4\cdot 10^{-3}$ at $λ=0.89$ nm. The time-of-flight device is composed of a fixed slit, a disk rotating up to $216$ Hz and a neutron detector with…
▽ More
A time-of-flight device was developed to characterize wavelength distribution and uniformity of a cold neutron beam. This device is very compact -- the distance of flight is $60$ cm -- but achieves very high resolution -- the intrinsic resolution $Δλ/λ=2.4\cdot 10^{-3}$ at $λ=0.89$ nm. The time-of-flight device is composed of a fixed slit, a disk rotating up to $216$ Hz and a neutron detector with a thin spherical conversion layer with the chopper slit in its focus. The device accepts the complete angular divergence of the initial neutron beam. The efficiency of neutron detection is constant over the detector area. Systematic corrections caused by neutron scattering in air are minimized due to the reduction of the time-of-flight length. Measurements have been performed on the beamline of the GRANIT experiment at ILL (part of the H172 beamline) on level C, and the first order diffraction peak of the crystal monochromator used for the GRANIT beamline was found to be at $λ=0.8961(11)$ nm, and having a width of $σ=0.0213(13)$ nm.
△ Less
Submitted 8 March, 2019; v1 submitted 29 May, 2018;
originally announced May 2018.