-
An Optical Readout TPC (O-TPC) for Studies in Nuclear Astrophysics With Gamma-Ray Beams at HIgS
Authors:
M. Gai,
M. W. Ahmed,
S. C. Stave,
W. R. Zimmerman,
A. Breskin,
B. Bromberger,
R. Chechik,
V. Dangendorf,
Th. Delbar,
R. H. France III,
S. S. Henshaw,
T. J. Kading,
P. P. Martel,
J. E. R. McDonald,
P. -N. Seo,
K. Tittelmeier,
H. R. Weller,
A. H. Young
Abstract:
We report on the construction, tests, calibrations and commissioning of an Optical Readout Time Projection Chamber (O-TPC) detector operating with a CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure the cross sections of several key nuclear reactions involved in stellar evolution. In particular, a study of the rate of formation of oxygen and carbon during the process o…
▽ More
We report on the construction, tests, calibrations and commissioning of an Optical Readout Time Projection Chamber (O-TPC) detector operating with a CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure the cross sections of several key nuclear reactions involved in stellar evolution. In particular, a study of the rate of formation of oxygen and carbon during the process of helium burning will be performed by exposing the chamber gas to intense nearly mono-energetic gamma-ray beams at the High Intensity Gamma Source (HIgS) facility. The O-TPC has a sensitive target-drift volume of 30x30x21 cm^3. Ionization electrons drift towards a double parallel grid avalanche multiplier, yielding charge multiplication and light emission. Avalanche induced photons from N2 emission are collected, intensified and recorded with a Charge Coupled Device (CCD) camera, providing two-dimensional track images. The event's time projection (third coordinate) and the deposited energy are recorded by photomultipliers and by the TPC charge-signal, respectively. A dedicated VME-based data acquisition system and associated data analysis tools were developed to record and analyze these data. The O-TPC has been tested and calibrated with 3.183 MeV alpha-particles emitted by a 148Gd source placed within its volume with a measured energy resolution of 3.0%. Tracks of alpha and 12C particles from the dissociation of 16O and of three alpha-particles from the dissociation of 12C have been measured during initial in-beam test experiments performed at the HIgS facility at Duke University. The full detection system and its performance are described and the results of the preliminary in-beam test experiments are reported.
△ Less
Submitted 10 January, 2011;
originally announced January 2011.
-
A Further Measurement of the beta-Delayed alpha-Particle Emission of 16N
Authors:
R. H. France III,
E. L. Wilds,
J. E. McDonald,
M. Gai
Abstract:
We measured the beta-delayed alpha-particle emission spectrum of 16N with a sensitivity for beta-decay branching ratios of the order of 10-10. The 16N nuclei were produced using the d(15N,16N)p reaction with 70 MeV 15N beams and a deuterium gas target 7.5 cm long at a pressure of 1250 torr. The 16N nuclei were collected (over 10 s) using a thin aluminum foil with an areal density of 180 mu g/cm2…
▽ More
We measured the beta-delayed alpha-particle emission spectrum of 16N with a sensitivity for beta-decay branching ratios of the order of 10-10. The 16N nuclei were produced using the d(15N,16N)p reaction with 70 MeV 15N beams and a deuterium gas target 7.5 cm long at a pressure of 1250 torr. The 16N nuclei were collected (over 10 s) using a thin aluminum foil with an areal density of 180 mu g/cm2 tilted at 7 Deg with respect to the beam. The activity was transferred to the counting area by means of a step** motor in less than 3 s with the counting carried out over 8 s. The beta-delayed alpha-particles were measured using a time of flight method to achieve a sufficiently low background. Standard calibration sources (148Gd, 241Am, 208,209Po, and 227Ac) as well as alpha-particles and 7Li from the 10B(n,alpha)7Li reaction were used for an accurate energy calibration. The energy resolution of the catcher foil (180-220 keV) was calculated and the time of flight resolution (3-10 nsec) was measured using the beta-delayed alpha-particle emission from 8Li that was produced using the d(7Li,8Li)p reaction with the same setup. The line shape was corrected to account for the variation in the energy and time resolution and a high statistics spectrum of the beta-delayed alpha-particle emission of 16N is reported. However, our data (as well as earlier Mainz data and unpublished Seattle data) do not agree with an earlier measurement of the beta-delayed alpha-particle emission of 16N taken at TRIUMF after averaging over the energy resolution of our collection system. This disagreement, amongst other issues, prohibits accurate inclusion of the f-wave component in the R-matrix analysis.
△ Less
Submitted 8 February, 2007;
originally announced February 2007.
-
In Beam Tests of Implanted Helium Targets
Authors:
J. E. McDonald,
R. H. France III,
R. A. Jarvis,
M. W. Ahmed,
M. A. Blackston,
Th. Delbar,
M. Gai,
T. J. Kading,
Y. Parpottas,
B. A. Perdue,
R. M. Prior,
D. A. Rubin,
M. C. Spraker,
J. D. Yeomans,
L. Weissman,
H. R. Weller,
E. L. Wilds Jr,
;,
UHartford,
GCSU,
LNS/UConn,
TUNL/Duke,
UCL/LLN,
Yale,
NGCSU
Abstract:
Targets consisting of 3,4He implanted into thin aluminum foils (approximately 100, 200 or 600 ug/cm^2) were prepared using intense (a few uA) helium beams at low energy (approximately 20, 40 or 100 keV). Uniformity of the implantation was achieved by a beam raster across a 12 mm diameter tantalum collimator at the rates of 0.1 Hz in the vertical direction and 1 Hz in the horizontal direction. He…
▽ More
Targets consisting of 3,4He implanted into thin aluminum foils (approximately 100, 200 or 600 ug/cm^2) were prepared using intense (a few uA) helium beams at low energy (approximately 20, 40 or 100 keV). Uniformity of the implantation was achieved by a beam raster across a 12 mm diameter tantalum collimator at the rates of 0.1 Hz in the vertical direction and 1 Hz in the horizontal direction. Helium implantation into the very thin (approximately 80-100 ug/cm^2) aluminum foils failed to produce useful targets (with only approximately 10% of the helium retained) due to an under estimation of the range by the code SRIM. The range of low energy helium in aluminum predicted by Northcliffe and Shilling and the NIST online tabulation are observed on the other hand to over estimate the range of low energy helium ions in aluminum. An attempt to increase the amount of helium by implanting a second deeper layer was also carried out, but it did not significantly increase the helium content beyond the blistering limit (approximately 6 x 10^17 helium/cm^2). The implanted targets were bombarded with moderately intense 4He and 16O beams of 50-100 particle nA . Rutherford Back Scattering of 1.0 and 2.5 MeV proton beams and recoil helium from 15.0 MeV oxygen beams were used to study the helium content and profile before, during and after bombardments. We observed the helium content and profile to be very stable even after a prolonged bombardment (up to two days) with moderately intense beams of 16O or 4He. Helium implanted into thin (aluminum) foils is a good choice for thin helium targets needed, for example, for a measurement of the 3he(a,g)7Be reaction and the associated S34 astrophysical cross section factor (S-factor).
△ Less
Submitted 16 August, 2006;
originally announced August 2006.
-
Absolute Branching Ratio of Beta-Delayed Gamma-Ray Emission of N18
Authors:
R. H. France III,
Z. Zhao,
M. Gai
Abstract:
The absolute branching ratio of the beta-delayed gamma-ray emission of N18 was measured, providing absolute normalization of the previous work by Olness et al. [J.W. Olness et al., Nuc. Phys. A373, 13 (1982)] who measured the relative branching ratios for the individual gamma-rays. We find the total absolute branching ratio for beta-delayed gamma emission of N18 to be 76.7 +/- 7.2(stat) +/- 5.8(…
▽ More
The absolute branching ratio of the beta-delayed gamma-ray emission of N18 was measured, providing absolute normalization of the previous work by Olness et al. [J.W. Olness et al., Nuc. Phys. A373, 13 (1982)] who measured the relative branching ratios for the individual gamma-rays. We find the total absolute branching ratio for beta-delayed gamma emission of N18 to be 76.7 +/- 7.2(stat) +/- 5.8(norm)%. A combination of other results suggests a value consistent with our result, but smaller than that calculated by Millener as quoted in Olness et al.
△ Less
Submitted 9 July, 2003; v1 submitted 7 July, 2003;
originally announced July 2003.
-
How Well Do We Know the Beta-Decay of N16 and Oxygen Formation in Helium Burning?
Authors:
Ralph H France III,
Moshe Gai
Abstract:
Contrary to claims that the problem has been solved, the astrophysical E1 S-factor of \c12ag is not yet well known. R-Matrix analyses of elastic scattering data,\c12ag data, and data on the beta-delayed alpha-particle emission of N16 are not consistent and a small S-factor solution SE1(300) cannot be ruled out. In particular, data on the beta- delayed alpha-particle emission of N16 do not agree.…
▽ More
Contrary to claims that the problem has been solved, the astrophysical E1 S-factor of \c12ag is not yet well known. R-Matrix analyses of elastic scattering data,\c12ag data, and data on the beta-delayed alpha-particle emission of N16 are not consistent and a small S-factor solution SE1(300) cannot be ruled out. In particular, data on the beta- delayed alpha-particle emission of N16 do not agree. The unaltered Mainz data do not agree with TRIUMF, but agree with both Seattle and Yale-UConn. The TRIUMF col- laboration has recalibratedthe Mainz('71) data; however, we dispute both the alteration of the Mainz data performed by the TRIUMF col- laboration and the very justification for the recalibration.
△ Less
Submitted 17 September, 1998;
originally announced September 1998.
-
Comment on Constraints on the Low-Energy E1 Cross Section of 12C(alpha,gamma)16O from the Beta-Delayed Alpha Spectrum of 16N
Authors:
Ralph H. France III,
Moshe Gai
Abstract:
We dispute the alteration by Azuma et al. of the energy calibration of the Mainz('71) data on the beta-delayed alpha-particle emission of $^{16}N$ as well as the very justification of the recalibration. We use the unaltered data to observe a pronounced disagreement between the TRIUMF('94) and Mainz('71) data sets on both the high and low energy sides of the primary peak (at 2.36 MeV) of the…
▽ More
We dispute the alteration by Azuma et al. of the energy calibration of the Mainz('71) data on the beta-delayed alpha-particle emission of $^{16}N$ as well as the very justification of the recalibration. We use the unaltered data to observe a pronounced disagreement between the TRIUMF('94) and Mainz('71) data sets on both the high and low energy sides of the primary peak (at 2.36 MeV) of the $^{16}N$ alpha-spectrum. We cannot support the dismissal of the Mainz('71) spectrum by the TRIUMF collaboration and emphasize the need to include it in R-matrix fits. We discuss the need for new improved data to resolve this disagreement and its implication for the extracted p-wave astrophysical S-factor of the $^{12}C(α,γ)^{16}O$ reaction.
△ Less
Submitted 11 September, 1997; v1 submitted 31 July, 1997;
originally announced July 1997.