-
Kinetic inductance current sensor for visible to near-infrared wavelength transition-edge sensor readout
Authors:
Paul Szypryt,
Douglas A. Bennett,
Ian Fogarty Florang,
Joseph W. Fowler,
Andrea Giachero,
Ruslan Hummatov,
Adriana E. Lita,
John A. B. Mates,
Sae Woo Nam,
Galen C. O'Neil,
Daniel S. Swetz,
Joel N. Ullom,
Michael R. Vissers,
Jordan Wheeler,
Jiansong Gao
Abstract:
Single-photon detectors based on the superconducting transition-edge sensor (TES) are used in a number of visible to near-infrared (VNIR) applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale photonic quantum computing or for future spectroscopic imaging applications in astronomy, the size of VNIR TES arrays must be incr…
▽ More
Single-photon detectors based on the superconducting transition-edge sensor (TES) are used in a number of visible to near-infrared (VNIR) applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale photonic quantum computing or for future spectroscopic imaging applications in astronomy, the size of VNIR TES arrays must be increased from a few pixels to many thousands. Historically, TES arrays have been read out with multiplexed superconducting quantum interference devices (SQUIDs), but the microsecond-duration pulse signals of VNIR TESs are notoriously difficult to multiplex. In this manuscript, we introduce the kinetic inductance current sensor (KICS), a more readily scalable readout technology that exploits the nonlinear kinetic inductance in a superconducting resonator to make sensitive current measurements. KICS devices can replace SQUIDs for many applications because of their ability to measure fast, high slew-rate signals, their compatibility with standard microwave frequency-division multiplexing techniques, and their relatively simple fabrication. Here, we demonstrate the readout of a VNIR TES using a KICS with $3.7$ $\text{MHz}$ of bandwidth. We measure a readout noise of $1.4$ $\text{pA}/\sqrt{\text{Hz}}$, considerably below the TES noise at frequencies of interest, and a TES energy resolution of $(0.137 \pm 0.001)$ $\text{eV}$ at $0.8$ $\text{eV}$, comparable to resolutions observed with non-multiplexed SQUID readouts.
△ Less
Submitted 23 May, 2024;
originally announced May 2024.
-
Spectroscopic measurements and models of energy deposition in the substrate of quantum circuits by natural ionizing radiation
Authors:
Joseph W. Fowler,
Paul Szypryt,
Raymond Bunker,
Ellen R. Edwards,
Ian Fogarty Florang,
Jiansong Gao,
Andrea Giachero,
Shannon F. Hoogerheide,
Ben Loer,
H. Pieter Mumm,
Nathan Nakamura,
Galen C. O'Neil,
John L. Orrell,
Elizabeth M. Scott,
Jason Stevens,
Daniel S. Swetz,
Brent A. VanDevender,
Michael Vissers,
Joel N. Ullom
Abstract:
Naturally occurring background radiation is a source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. To characterize the radiation environment in an unshielded laboratory, we performed broadband, spectroscopic measurements of background events in silicon substrates located inside a millikelvin refrigerator, an environment representative of s…
▽ More
Naturally occurring background radiation is a source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. To characterize the radiation environment in an unshielded laboratory, we performed broadband, spectroscopic measurements of background events in silicon substrates located inside a millikelvin refrigerator, an environment representative of superconducting qubit systems. We measured the background spectra in silicon substrates of two thicknesses, 0.5 mm and 1.5 mm, and obtained the average event rate and the integrated power deposition. In a 25 mm^2 area and the thinner substrate, these values are 0.023 events per second and 4.9 keV/s, counting events that deposit at least 40 keV. We find the background spectrum to be nearly featureless. Its intensity decreases by a factor of 40,000 between 100 keV and 3 MeV for silicon substrates 0.5 mm thick. We find the cryogenic measurements to be in good agreement with predictions based on measurements of the terrestrial gamma-ray flux, published models of cosmic-ray fluxes, a crude model of the cryostat, and radiation-transport simulations. No free parameters are required to predict the background spectra in the silicon substrates. The good agreement between measurements and predictions allow assessment of the relative contributions of terrestrial and cosmic background sources and their dependence on substrate thickness. Our spectroscopic measurements are performed with superconducting microresonators that transduce deposited energy to a readily detectable electrical signal. We find that gamma-ray emissions from radioisotopes are responsible for the majority of events depositing E<1.5 MeV, while nucleons among the cosmic-ray secondary particles cause most events that deposit more energy. These results suggest several paths to reducing the impact of background radiation on quantum circuits.
△ Less
Submitted 16 April, 2024;
originally announced April 2024.
-
A tabletop x-ray tomography instrument for nanometer-scale imaging: demonstration of the 1,000-element transition-edge sensor subarray
Authors:
Paul Szypryt,
Nathan Nakamura,
Daniel T. Becker,
Douglas A. Bennett,
Amber L. Dagel,
W. Bertrand Doriese,
Joseph W. Fowler,
Johnathon D. Gard,
J. Zachariah Harris,
Gene C. Hilton,
Jozsef Imrek,
Edward S. Jimenez,
Kurt W. Larson,
Zachary H. Levine,
John A. B. Mates,
D. McArthur,
Luis Miaja-Avila,
Kelsey M. Morgan,
Galen C. O'Neil,
Nathan J. Ortiz,
Christine G. Pappas,
Daniel R. Schmidt,
Kyle R. Thompson,
Joel N. Ullom,
Leila Vale
, et al. (6 additional authors not shown)
Abstract:
We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly efficient and pixelated TES spectrometer to reconstruct three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel prototype spectrometer was recent…
▽ More
We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly efficient and pixelated TES spectrometer to reconstruct three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel prototype spectrometer was recently used to reconstruct ICs at the 130 nm technology node, but to increase imaging speed to more practical levels, the detector efficiency needs to be improved. For this reason, we are building a spectrometer that will eventually contain 3,000 TES microcalorimeters read out with microwave superconducting quantum interference device (SQUID) multiplexing, and we currently have commissioned a 1,000 TES subarray. This still represents a significant improvement from the 240-pixel system and allows us to begin characterizing the full spectrometer performance. Of the 992 maximimum available readout channels, we have yielded 818 devices, representing the largest number of TES x-ray microcalorimeters simultaneously read out to date. These microcalorimeters have been optimized for pulse speed rather than purely energy resolution, and we measure a FWHM energy resolution of 14 eV at the 8.0 keV Cu K$α$ line.
△ Less
Submitted 22 December, 2022;
originally announced December 2022.
-
Nanoscale Three-Dimensional Imaging of Integrated Circuits using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer
Authors:
Nathan Nakamura,
Paul Szypryt,
Amber L. Dagel,
Bradley K. Alpert,
Douglas A. Bennett,
W. Bertrand Doriese,
Malcolm Durkin,
Joseph W. Fowler,
Dylan T. Fox,
Johnathon D. Gard,
Ryan N. Goodner,
J. Zachariah Harris,
Gene C. Hilton,
Edward S. Jimenez,
Burke L. Kernen,
Kurt W. Larson,
Zachary H. Levine,
Daniel McArthur,
Kelsey M. Morgan,
Galen C. O'Neil,
Nathan J. Ortiz,
Christine G. Pappas,
Carl D. Reintsema,
Daniel R. Schmidt,
Peter A. Schultz
, et al. (8 additional authors not shown)
Abstract:
X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but is difficult to implement due to competing requirements on X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial res…
▽ More
X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but is difficult to implement due to competing requirements on X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while changing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot in a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with high signal-to-noise. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enable nanoscale, element-specific X-ray imaging in a compact footprint. The proof-of-concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in 6 layers of a Cu-SiO2 integrated circuit, and a path towards finer resolution and enhanced imaging capabilities is discussed.
△ Less
Submitted 4 March, 2024; v1 submitted 20 December, 2022;
originally announced December 2022.
-
Design of a 3000-pixel transition-edge sensor x-ray spectrometer for microcircuit tomography
Authors:
Paul Szypryt,
Douglas A. Bennett,
William J. Boone,
Amber L. Dagel,
Gabriella Dalton,
W. Bertrand Doriese,
Joseph W. Fowler,
Edward J. Garboczi,
Johnathon D. Gard,
Gene C. Hilton,
Jozsef Imrek,
Edward S. Jimenez,
Vincent Y. Kotsubo,
Kurt Larson,
Zachary H. Levine,
John A. B. Mates,
Daniel McArthur,
Kelsey M. Morgan,
Nathan Nakamura,
Galen C. O'Neil,
Nathan J. Ortiz,
Christine G. Pappas,
Carl D. Reintsema,
Daniel R. Schmidt,
Daniel S. Swetz
, et al. (6 additional authors not shown)
Abstract:
Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approa…
▽ More
Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approach that addresses this imaging problem through x-ray tomography, which we uniquely realize with an instrument that combines a scanning electron microscope (SEM) with a transition-edge sensor (TES) x-ray spectrometer. Our approach uses the highly focused SEM electron beam to generate a small x-ray generation region in a carefully designed target layer that is placed over the sample being tested. With the high collection efficiency and resolving power of a TES spectrometer, we can isolate x-rays generated in the target from background and trace their paths through regions of interest in the sample layers, providing information about the various materials along the x-ray paths through their attenuation functions. We have recently demonstrated our approach using a 240 Mo/Cu bilayer TES prototype instrument on a simplified test sample containing features with sizes of $\sim$1 $μ$m. Currently, we are designing and building a 3000 Mo/Au bilayer TES spectrometer upgrade, which is expected to improve the imaging speed by factor of up to 60 through a combination of increased detector number and detector speed.
△ Less
Submitted 14 December, 2022;
originally announced December 2022.
-
The potential of microcalorimeter x-ray spectrometers for measurement of relative fluorescence-line intensities
Authors:
J. W. Fowler,
L. Miaja-Avila,
G. C. O'Neil,
J. N. Ullom,
H. Whitelock,
D. S. Swetz
Abstract:
We have previously used an array of cryogenic microcalorimeters with 4 eV energy resolution to measure emission-line profiles and energies of the characteristic L-shell x rays of four elements of the lanthanide series: praseodymium, neodymium, terbium, and holmium. We consider the power of the same data set for the estimation of the lines' relative intensities. Intensities must be corrected for de…
▽ More
We have previously used an array of cryogenic microcalorimeters with 4 eV energy resolution to measure emission-line profiles and energies of the characteristic L-shell x rays of four elements of the lanthanide series: praseodymium, neodymium, terbium, and holmium. We consider the power of the same data set for the estimation of the lines' relative intensities. Intensities must be corrected for detector efficiency and self-absorption, and we estimate uncertainties on the corrections. These data represent one of the first uses of cryogenic energy-dispersive sensors to estimate the relative intensities of x-ray fluorescence lines. They show that a future measurement of thin-film samples with microcalorimeter detectors could achieve systematic uncertainties below 1% on relative line intensities over a broad energy range.
△ Less
Submitted 16 August, 2022;
originally announced August 2022.
-
Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV
Authors:
Daikang Yan,
Joel C. Weber,
Tejas Guruswamy,
Kelsey M. Morgan,
Galen C. O'Neil,
Abigail L. Wessels,
Douglas A. Bennett,
Christine G. Pappas,
John A. Mates,
Johnathon D. Gard,
Daniel T. Becker,
Joseph W. Fowler,
Daniel S. Swetz,
Daniel R. Schmidt,
Joel N. Ullom,
Takuma Okumura,
Tadaaki Isobe,
Toshiyuki Azuma,
Shinji Okada,
Shinya Yamada,
Tadashi Hashimoto,
Orlando Quaranta,
Antonino Miceli,
Lisa M. Gades,
Umeshkumar M. Patel
, et al. (3 additional authors not shown)
Abstract:
Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard x-ray TESs to measure the absolute energies of muonic-argon ($μ$-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers…
▽ More
Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard x-ray TESs to measure the absolute energies of muonic-argon ($μ$-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. We achieved ~ 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.
△ Less
Submitted 21 July, 2022;
originally announced July 2022.
-
Energy calibration of nonlinear microcalorimeters with uncertainty estimates from Gaussian process regression
Authors:
J. W. Fowler,
B. K. Alpert,
G. C. O'Neil,
D. S. Swetz,
J. N. Ullom
Abstract:
The nonlinear energy response of cryogenic microcalorimeters is usually corrected through an empirical calibration. X-ray or gamma-ray emission lines of known shape and energy anchor a smooth function that generalizes the calibration data and converts detector measurements to energies. We argue that this function should be an approximating spline. The theory of Gaussian process regression makes a…
▽ More
The nonlinear energy response of cryogenic microcalorimeters is usually corrected through an empirical calibration. X-ray or gamma-ray emission lines of known shape and energy anchor a smooth function that generalizes the calibration data and converts detector measurements to energies. We argue that this function should be an approximating spline. The theory of Gaussian process regression makes a case for this functional form. It also provides an important benefit previously absent from our calibration method: a quantitative uncertainty estimate for the calibrated energies, with lower uncertainty near the best-constrained calibration points.
△ Less
Submitted 13 April, 2022;
originally announced April 2022.
-
Quantification of 242Pu with a Microcalorimeter Gamma Spectrometer
Authors:
David J. Mercer,
Ryan Winkler,
Katrina E. Koehler,
Daniel T. Becker,
Douglas A. Bennett,
Matthew H. Carpenter,
Mark P. Croce,
Krystal I. de Castro,
Eric A. Feissle,
Joseph W. Fowler,
Johnathon D. Gard,
John A. B. Mates,
Daniel G. McNeel,
Nathan J. Ortiz,
Daniel Schmidt,
Katherine A. Schreiber,
Daniel S. Swetz,
Joel N. Ullom,
Leila R. Vale,
Sophie L. Weidenbenner,
Abigail L. Wessels
Abstract:
We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measurement of an unprepared sample, and so represents an important advance in nuclear material accountancy. The measurement campaign also serves as the first demonstration of a field campaign with a portable microcalorimeter…
▽ More
We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measurement of an unprepared sample, and so represents an important advance in nuclear material accountancy. The measurement campaign also serves as the first demonstration of a field campaign with a portable microcalorimeter gamma-ray spectrometer. For the 103-keV gamma ray we report an improved centroid energy and emission probability.
△ Less
Submitted 8 July, 2022; v1 submitted 6 February, 2022;
originally announced February 2022.
-
The CatWISE2020 Catalog
Authors:
Federico Marocco,
Peter R. M. Eisenhardt,
John W. Fowler,
J. Davy Kirkpatrick,
Aaron M. Meisner,
Edward F. Schlafly,
S. Adam Stanford,
Nelson Garcia,
Dan Caselden,
Michael C. Cushing,
Roc M. Cutri,
Jacqueline K. Faherty,
Christopher R. Gelino,
Anthony H. Gonzalez,
Thomas H. Jarrett,
Renata Koontz,
Amanda Mainzer,
Elijah J. Marchese,
Bahram Mobasher,
David J. Schlegel,
Daniel Stern,
Harry I. Teplitz,
Edward L. Wright
Abstract:
The CatWISE2020 Catalog consists of 1,890,715,640 sources over the entire sky selected from WISE and NEOWISE survey data at 3.4 and 4.6 $μ$m (W1 and W2) collected from 2010 Jan. 7 to 2018 Dec. 13. This dataset adds two years to that used for the CatWISE Preliminary Catalog (Eisenhardt et al., 2020), bringing the total to six times as many exposures spanning over sixteen times as large a time basel…
▽ More
The CatWISE2020 Catalog consists of 1,890,715,640 sources over the entire sky selected from WISE and NEOWISE survey data at 3.4 and 4.6 $μ$m (W1 and W2) collected from 2010 Jan. 7 to 2018 Dec. 13. This dataset adds two years to that used for the CatWISE Preliminary Catalog (Eisenhardt et al., 2020), bringing the total to six times as many exposures spanning over sixteen times as large a time baseline as the AllWISE catalog. The other major change from the CatWISE Preliminary Catalog is that the detection list for the CatWISE2020 Catalog was generated using ${\it crowdsource}$ (Schlafly et al. 2019), while the CatWISE Preliminary Catalog used the detection software used for AllWISE. These two factors result in roughly twice as many sources in the CatWISE2020 Catalog. The scatter with respect to ${\it Spitzer}$ photometry at faint magnitudes in the COSMOS field, which is out of the Galactic plane and at low ecliptic latitude (corresponding to lower WISE coverage depth) is similar to that for the CatWISE Preliminary Catalog. The 90% completeness depth for the CatWISE2020 Catalog is at W1=17.7 mag and W2=17.5 mag, 1.7 mag deeper than in the CatWISE Preliminary Catalog. From comparison to ${\it Gaia}$, CatWISE2020 motions are accurate at the 20 mas yr$^{-1}$ level for W1$\sim$15 mag sources, and at the $\sim100$ mas yr$^{-1}$ level for W1$\sim$17 mag sources. This level of precision represents a 12$\times$ improvement over AllWISE. The CatWISE catalogs are available in the WISE/NEOWISE Enhanced and Contributed Products area of the NASA/IPAC Infrared Science Archive.
△ Less
Submitted 23 December, 2020;
originally announced December 2020.
-
Absolute energies and emission line shapes of the L x-ray transitions of lanthanide metals
Authors:
Joseph W. Fowler,
Galen C. O'Neil,
Bradley K. Alpert,
Douglas A. Bennett,
Ed V. Denison,
W. B. Doriese,
Gene C. Hilton,
Lawrence T. Hudson,
Young-Il Joe,
Kelsey M. Morgan,
Daniel R. Schmidt,
Daniel S. Swetz,
Csilla I. Szabo,
Joel N. Ullom
Abstract:
We use an array of transition-edge sensors, cryogenic microcalorimeters with 4 eV energy resolution, to measure L x-ray emission-line profiles of four elements of the lanthanide series: praseodymium, neodymium, terbium, and holmium. The spectrometer also surveys numerous x-ray standards in order to establish an absolute-energy calibration traceable to the International System of Units for the ener…
▽ More
We use an array of transition-edge sensors, cryogenic microcalorimeters with 4 eV energy resolution, to measure L x-ray emission-line profiles of four elements of the lanthanide series: praseodymium, neodymium, terbium, and holmium. The spectrometer also surveys numerous x-ray standards in order to establish an absolute-energy calibration traceable to the International System of Units for the energy range 4 keV to 10 keV. The new results include emission line profiles for 97 lines, each expressed as a sum of one or more Voigt functions; improved absolute energy uncertainty on 71 of these lines relative to existing reference data; a median uncertainty on the peak energy of 0.24 eV, four to ten times better than the median of prior work; and 6 lines that lack any measured values in existing reference tables. The 97 lines comprise nearly all of the most intense L lines from these elements under broad-band x-ray excitation. The work improves on previous measurements made with a similar cryogenic spectrometer by the use of sensors with better linearity in the absorbed energy and a gold x-ray absorbing layer that has a Gaussian energy-response function. It also employs a novel sample holder that enables rapid switching between science targets and calibration targets with excellent gain balancing. Most of the results for peak energy values shown here should be considered as replacements for the currently tabulated standard reference values, while the line shapes given here represent a significant expansion of the scope of available reference data.
△ Less
Submitted 30 November, 2020;
originally announced December 2020.
-
A Transition-edge Sensor-based X-ray Spectrometer for the Study of Highly Charged Ions at the National Institute of Standards and Technology Electron Beam Ion Trap
Authors:
P. Szypryt,
G. C. O'Neil,
E. Takacs,
J. N. Tan,
S. W. Buechele,
A. S. Naing,
D. A. Bennett,
W. B. Doriese,
M. Durkin,
J. W. Fowler,
J. D. Gard,
G. C. Hilton,
K. M. Morgan,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
Yu. Ralchenko
Abstract:
We report on the design, commissioning, and initial measurements of a Transition-edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few decades, the NIST EBIT has produced numerous studies of highly charged ions in diverse fields such as atomic physics, plasma spectroscopy, and laboratory astrophysi…
▽ More
We report on the design, commissioning, and initial measurements of a Transition-edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few decades, the NIST EBIT has produced numerous studies of highly charged ions in diverse fields such as atomic physics, plasma spectroscopy, and laboratory astrophysics. The newly commissioned NIST EBIT TES Spectrometer (NETS) improves the measurement capabilities of the EBIT through a combination of high x-ray collection efficiency and resolving power. NETS utilizes 192 individual TES x-ray microcalorimeters (166/192 yield) to improve upon the collection area by a factor of ~30 over the 4-pixel neutron transmutation doped germanium-based microcalorimeter spectrometer previously used at the NIST EBIT. The NETS microcalorimeters are optimized for the x-ray energies from roughly 500 eV to 8,000 eV and achieve an energy resolution of 3.7 eV to 5.0 eV over this range, a more modest (<2X) improvement over the previous microcalorimeters. Beyond this energy range NETS can operate with various trade-offs, the most significant of which are reduced efficiency at lower energies and being limited to a subset of the pixels at higher energies. As an initial demonstration of the capabilities of NETS, we measured transitions in He-like and H-like O, Ne, and Ar as well as Ni-like W. We detail the energy calibration and data analysis techniques used to transform detector counts into x-ray spectra, a process that will be the basis for analyzing future data.
△ Less
Submitted 11 May, 2020;
originally announced May 2020.
-
The cross correlation of the ABS and ACT maps
Authors:
Zack Li,
Sigurd Naess,
Simone Aiola,
David Alonso,
John W. Appel,
J. Richard Bond,
Erminia Calabrese,
Steve K. Choi,
Kevin T. Crowley,
Thomas Essinger-Hileman,
Shannon M. Duff,
Joanna Dunkley,
J. W. Fowler,
Patricio Gallardo,
Shuay-Pwu Patty Ho,
Johannes Hubmayr,
Akito Kusaka,
Thibaut Louis,
Mathew S. Madhavacheril,
Jeffrey McMahon,
Federico Nati,
Michael D. Niemack,
Lyman Page,
Lucas Parker,
Bruce Partridge
, et al. (7 additional authors not shown)
Abstract:
One of the most important checks for systematic errors in CMB studies is the cross correlation of maps made by independent experiments. In this paper we report on the cross correlation between maps from the Atacama B-mode Search (ABS) and Atacama Cosmology Telescope (ACT) experiments in both temperature and polarization. These completely different measurements have a clear correlation with each ot…
▽ More
One of the most important checks for systematic errors in CMB studies is the cross correlation of maps made by independent experiments. In this paper we report on the cross correlation between maps from the Atacama B-mode Search (ABS) and Atacama Cosmology Telescope (ACT) experiments in both temperature and polarization. These completely different measurements have a clear correlation with each other and with the Planck satellite in both the EE and TE spectra at $\ell<400$ over the roughly $1100$ deg$^2$ common to all three. The TB, EB, and BB cross spectra are consistent with noise. Exploiting such cross-correlations will be important for future experiments operating in Chile that aim to probe the $30<\ell<8,000$ range.
△ Less
Submitted 5 January, 2021; v1 submitted 13 February, 2020;
originally announced February 2020.
-
Expanding the Y Dwarf Census with Spitzer Follow-up of the Coldest CatWISE Solar Neighborhood Discoveries
Authors:
Aaron M. Meisner,
Dan Caselden,
J. Davy Kirkpatrick,
Federico Marocco,
Christopher R. Gelino,
Michael C. Cushing,
Peter R. M. Eisenhardt,
Edward L. Wright,
Jacqueline K. Faherty,
Renata Koontz,
Elijah J. Marchese,
Mohammed Khalil,
John W. Fowler,
Edward F. Schlafly
Abstract:
We present Spitzer 3.6$μ$m and 4.5$μ$m follow-up of 170 candidate extremely cool brown dwarfs newly discovered via the combination of WISE and NEOWISE imaging at 3$-$5$μ$m. CatWISE, a joint analysis of archival WISE and NEOWISE data, has improved upon the motion measurements of AllWISE by leveraging a $>$10$\times$ time baseline enhancement, from 0.5 years (AllWISE) to 6.5 years (CatWISE). As a re…
▽ More
We present Spitzer 3.6$μ$m and 4.5$μ$m follow-up of 170 candidate extremely cool brown dwarfs newly discovered via the combination of WISE and NEOWISE imaging at 3$-$5$μ$m. CatWISE, a joint analysis of archival WISE and NEOWISE data, has improved upon the motion measurements of AllWISE by leveraging a $>$10$\times$ time baseline enhancement, from 0.5 years (AllWISE) to 6.5 years (CatWISE). As a result, CatWISE motion selection has yielded a large sample of previously unrecognized brown dwarf candidates, many of which have archival detections exclusively in the WISE 4.6$μ$m (W2) channel, suggesting that they could be both exceptionally cold and nearby. Where these objects go undetected in WISE W1 (3.4$μ$m), Spitzer can provide critically informative detections at 3.6$μ$m. Of our motion-confirmed discoveries, seventeen have a best-fit Spitzer [3.6]$-$[4.5] color most consistent with spectral type Y. CWISEP J144606.62$-$231717.8 ($μ\approx 1.3''$/yr) is likely the reddest, and therefore potentially coldest, member of our sample with a very uncertain [3.6]$-$[4.5] color of 3.71 $\pm$ 0.44 magnitudes. We also highlight our highest proper motion discovery, WISEA J153429.75$-$104303.3, with $μ\approx 2.7''$/yr. Given that the prior list of confirmed and presumed Y dwarfs consists of just 27 objects, the Spitzer follow-up presented in this work has substantially expanded the sample of identified Y dwarfs. Our new discoveries thus represent significant progress toward understanding the bottom of the substellar mass function, investigating the diversity of the Y dwarf population, and selecting optimal brown dwarf targets for JWST spectroscopy.
△ Less
Submitted 27 November, 2019;
originally announced November 2019.
-
A robust principal component analysis for outlier identification in messy microcalorimeter data
Authors:
J. W. Fowler,
B. K. Alpert,
Y. -I. Joe,
G. C. O'Neil,
D. S. Swetz,
J. N. Ullom
Abstract:
A principal component analysis (PCA) of clean microcalorimeter pulse records can be a first step beyond statistically optimal linear filtering of pulses towards a fully non-linear analysis. For PCA to be practical on spectrometers with hundreds of sensors, an automated identification of clean pulses is required. Robust forms of PCA are the subject of active research in machine learning. We examine…
▽ More
A principal component analysis (PCA) of clean microcalorimeter pulse records can be a first step beyond statistically optimal linear filtering of pulses towards a fully non-linear analysis. For PCA to be practical on spectrometers with hundreds of sensors, an automated identification of clean pulses is required. Robust forms of PCA are the subject of active research in machine learning. We examine a version known as coherence pursuit that is simple, fast, and well matched to the automatic identification of outlier records, as needed for microcalorimeter pulse analysis.
△ Less
Submitted 1 November, 2019;
originally announced November 2019.
-
Working principle and demonstrator of microwave-multiplexing for the HOLMES experiment microcalorimeters
Authors:
D. T. Becker,
D. A. Bennett,
M. Biasotti,
M. Borghesi,
V. Ceriale,
M. De Gerone,
M. Faverzani,
E. Ferri,
J. W. Fowler,
G. Gallucci,
J. D. Gard,
A. Giachero,
J. P. Hays-Wehle,
G. C. Hilton,
J. A. B Mates,
A. Nucciotti,
A. Orlando,
G. Pessina,
A. Puiu,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R Vale
Abstract:
The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to measure the end-point energy of the electron capture (EC) decay of $^{163}$Ho with a statistical sensitivity on the neutrino mass as low as $\sim 1$ eV/c$^2$. In…
▽ More
The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to measure the end-point energy of the electron capture (EC) decay of $^{163}$Ho with a statistical sensitivity on the neutrino mass as low as $\sim 1$ eV/c$^2$. In order to acquire the large needed statistics, by kee** the pile-up contribution as low as possible, 1024 transition edge sensors (TESs) with high energy and time resolutions will be employed. Microcalorimeter and bolometer arrays based on transition edge sensor with thousands of pixels are under development for several space-based and ground-based applications, including astrophysics, nuclear and particle physics, and materials science. The common necessary challenge is to develop pratical multiplexing techniques in order to simplify the cryogenics and readout systems. Despite the various multiplexing variants which are being developed have been successful, new approaches are needed to enable scaling to larger pixel counts and faster sensors, as requested for HOLMES, reducing also the cost and complexity of readout. A very novel technique that meets all of these requirements is based on superconducting microwave resonators coupled to radio-frequency Superconducting Quantum Interference Devices, in which the the changes in the TES input current is tranduced to a change in phase of a microwave signal. In this work we introduce the basics of this technique, the design and development of the first two-channel read out system and its performances with the first TES detectors specifically designed for HOLMES. In the last part we explain how to extend this approach scaling to 1024 pixels.
△ Less
Submitted 11 October, 2019;
originally announced October 2019.
-
The CatWISE Preliminary Catalog: Motions from ${\it WISE}$ and ${\it NEOWISE}$ Data
Authors:
Peter R. M. Eisenhardt,
Federico Marocco,
John W. Fowler,
Aaron M. Meisner,
J. Davy Kirkpatrick,
Nelson Garcia,
Thomas H. Jarrett,
Renata Koontz,
Elijah J. Marchese,
S. Adam Stanford,
Dan Caselden,
Michael C. Cushing,
Roc M. Cutri,
Jacqueline K. Faherty,
Christopher R. Gelino,
Anthony H. Gonzalez,
Amanda Mainzer,
Bahram Mobasher,
David J. Schlegel,
Daniel Stern,
Harry I. Teplitz,
Edward L. Wright
Abstract:
CatWISE is a program to catalog sources selected from combined ${\it WISE}$ and ${\it NEOWISE}$ all-sky survey data at 3.4 and 4.6 $μ$m (W1 and W2). The CatWISE Preliminary Catalog consists of 900,849,014 sources measured in data collected from 2010 to 2016. This dataset represents four times as many exposures and spans over ten times as large a time baseline as that used for the AllWISE Catalog.…
▽ More
CatWISE is a program to catalog sources selected from combined ${\it WISE}$ and ${\it NEOWISE}$ all-sky survey data at 3.4 and 4.6 $μ$m (W1 and W2). The CatWISE Preliminary Catalog consists of 900,849,014 sources measured in data collected from 2010 to 2016. This dataset represents four times as many exposures and spans over ten times as large a time baseline as that used for the AllWISE Catalog. CatWISE adapts AllWISE software to measure the sources in coadded images created from six-month subsets of these data, each representing one coverage of the inertial sky, or epoch. The catalog includes the measured motion of sources in 8 epochs over the 6.5 year span of the data. From comparison to ${\it Spitzer}$, the SNR=5 limits in magnitudes in the Vega system are W1=17.67 and W2=16.47, compared to W1=16.96 and W2=16.02 for AllWISE. From comparison to ${\it Gaia}$, CatWISE positions have typical accuracies of 50 mas for stars at W1=10 mag and 275 mas for stars at W1=15.5 mag. Proper motions have typical accuracies of 10 mas yr$^{-1}$ and 30 mas yr$^{-1}$ for stars with these brightnesses, an order of magnitude better than from AllWISE. The catalog is available in the WISE/NEOWISE Enhanced and Contributed Products area of the NASA/IPAC Infrared Science Archive.
△ Less
Submitted 10 March, 2020; v1 submitted 23 August, 2019;
originally announced August 2019.
-
Resonant soft x-ray scattering from stripe-ordered La$_{2-x}$Ba$_x$CuO$_4$ detected by a transition edge sensor array detector
Authors:
Y. I. Joe,
Y. Fang,
S. Lee,
S. X. L. Sun,
G. A. de la Peña,
W. B. Doriese,
K. M. Morgan,
J. W. Fowler,
L. R. Vale,
F. Rodolakis,
J. L. McChesney,
J. N. Ullom,
D. S. Swetz,
P. Abbamonte
Abstract:
Resonant soft x-ray scattering (RSXS) is a leading probe of valence band order in materials best known for detecting charge density wave order in the copper-oxide superconductors. One of the biggest limitations on the RSXS technique is the presence of a severe fluorescence background which, like the RSXS cross section itself, is enhanced under resonant conditions. This background prevents the stud…
▽ More
Resonant soft x-ray scattering (RSXS) is a leading probe of valence band order in materials best known for detecting charge density wave order in the copper-oxide superconductors. One of the biggest limitations on the RSXS technique is the presence of a severe fluorescence background which, like the RSXS cross section itself, is enhanced under resonant conditions. This background prevents the study of weak signals such as diffuse scattering from glassy or fluctuating order that is spread widely over momentum space. Recent advances in superconducting transition edge sensor (TES) detectors have led to major improvements in energy resolution and detection efficiency in the soft x-ray range. Here, we perform a RSXS study of stripe-ordered La$_{2-x}$Ba$_x$CuO$_4$ at the Cu $L_{3/2}$ edge (932.2 eV) using a TES detector with 1.5 eV resolution, to evaluate its utility for mitigating the fluorescence background problem. We find that, for suitable degree of detuning from the resonance, the TES rejects the fluorescence background, leading to a 5 to 10 times improvement in the statistical quality of the data compared to an equivalent, energy-integrated measurement. We conclude that a TES presents a promising approach to reducing background in RSXS studies and may lead to new discoveries in materials exhibiting valence band order that is fluctuating or glassy.
△ Less
Submitted 16 February, 2020; v1 submitted 17 July, 2019;
originally announced July 2019.
-
Mitigating the effects of charged particle strikes on TES arrays for exotic atom X-ray experiments
Authors:
H. Tatsuno,
D. A. Bennett,
W. B. Doriese,
M. Durkin,
J. W. Fowler,
J. D. Gard,
T. Hashimoto,
R. Hayakawa,
T. Hayashi,
G. C. Hilton,
Y. Ichinohe,
H. Noda,
G. C. O'Neil,
S. Okada,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
S. Yamada
Abstract:
Exotic atom experiments place transition-edge-sensor (TES) microcalorimeter arrays in a high-energy charged particle rich environment. When a high-energy charged particle passes through the silicon substrate of a TES array, a large amount of energy is deposited and small pulses are generated across multiple pixels in the TES array due to thermal crosstalk. We have developed analysis techniques to…
▽ More
Exotic atom experiments place transition-edge-sensor (TES) microcalorimeter arrays in a high-energy charged particle rich environment. When a high-energy charged particle passes through the silicon substrate of a TES array, a large amount of energy is deposited and small pulses are generated across multiple pixels in the TES array due to thermal crosstalk. We have developed analysis techniques to assess and reduce the effects of charged particle events on exotic atom X-ray measurements. Using this technique, the high-energy and low-energy components of the X-ray peaks due to pileup are eliminated, improving the energy resolution from 6.6 eV to 5.7 eV at 6.9 keV.
△ Less
Submitted 20 May, 2020; v1 submitted 14 July, 2019;
originally announced July 2019.
-
CWISEP J193518.59$-$154620.3: An Extremely Cold Brown Dwarf in the Solar Neighborhood Discovered with CatWISE
Authors:
Federico Marocco,
Dan Caselden,
Aaron M. Meisner,
J. Davy Kirkpatrick,
Edward L. Wright,
Jacqueline K. Faherty,
Christopher R. Gelino,
Peter R. M. Eisenhardt,
John W. Fowler,
Michael C. Cushing,
Roc M. Cutri,
Nelson Garcia,
Thomas H. Jarrett,
Renata Koontz,
Amanda Mainzer,
Elijah J. Marchese,
Bahram Mobasher,
David J. Schlegel,
Daniel Stern,
Harry I. Teplitz
Abstract:
We present the discovery of an extremely cold, nearby brown dwarf in the solar neighborhood, found in the CatWISE catalog (Eisenhardt et al., in prep.). Photometric follow-up with Spitzer reveals that the object, CWISEP J193518.59-154620.3, has ch1$-$ch2 = 3.24$\,\pm\,$0.31 mag, making it one of the reddest brown dwarfs known. Using the Spitzer photometry and the polynomial relations from Kirkpatr…
▽ More
We present the discovery of an extremely cold, nearby brown dwarf in the solar neighborhood, found in the CatWISE catalog (Eisenhardt et al., in prep.). Photometric follow-up with Spitzer reveals that the object, CWISEP J193518.59-154620.3, has ch1$-$ch2 = 3.24$\,\pm\,$0.31 mag, making it one of the reddest brown dwarfs known. Using the Spitzer photometry and the polynomial relations from Kirkpatrick et al. (2019) we estimate an effective temperature in the $\sim$270--360 K range, and a distance estimate in the 5.6$-$10.9 pc range. We combined the WISE, NEOWISE, and Spitzer data to measure a proper motion of $μ_α\cos δ= 337\pm69$ mas yr$^{-1}$, $μ_δ= -50\pm97$ mas yr$^{-1}$, which implies a relatively low tangential velocity in the range 7$-$22 km s$^{-1}$.
△ Less
Submitted 20 June, 2019;
originally announced June 2019.
-
A Highly Linear Calibration Metric for TES X-ray Microcalorimeters
Authors:
C. G. Pappas,
J. W. Fowler,
D. A. Bennett,
W. B. Doriese,
Y. I. Joe,
K. M. Morgan,
G. C. O'Neil,
J. N. Ullom,
D. S. Swetz
Abstract:
Transition-edge sensor X-ray microcalorimeters are usually calibrated empirically, as the most widely-used calibration metric, optimal filtered pulse height (OFPH), in general has an unknown dependance on photon energy, $E_γ$. Because the calibration function can only be measured at specific points where photons of a known energy can be produced, this unknown dependence of OFPH on $E_γ$ leads to c…
▽ More
Transition-edge sensor X-ray microcalorimeters are usually calibrated empirically, as the most widely-used calibration metric, optimal filtered pulse height (OFPH), in general has an unknown dependance on photon energy, $E_γ$. Because the calibration function can only be measured at specific points where photons of a known energy can be produced, this unknown dependence of OFPH on $E_γ$ leads to calibration errors and the need for time-intensive calibration measurements and analysis. A calibration metric that is nearly linear as a function of $E_γ$ could help alleviate these problems. In this work, we assess the linearity of a physically motivated calibration metric, $E_{Joule}$. We measure calibration pulses in the range 4.5 keV$<$$E_γ$$<$9.6 keV with detectors optimized for 6 keV photons to compare the linearity properties of $E_{Joule}$ to OFPH. In these test data sets, we find that $E_{Joule}$ fits a linear function an order of magnitude better than OFPH. Furthermore, calibration functions using $E_{J}$, an optimized version of $E_{Joule}$, are linear within the 2-3 eV noise of the data.
△ Less
Submitted 1 August, 2018;
originally announced August 2018.
-
Approaches to the Optimal Nonlinear Analysis of Microcalorimeter Pulses
Authors:
J. W. Fowler,
C. G. Pappas,
B. K. Alpert,
W. B. Doriese,
G. C. O'Neil,
J. N. Ullom,
D. S. Swetz
Abstract:
We consider how to analyze microcalorimeter pulses for quantities that are nonlinear in the data, while preserving the signal-to-noise advantages of lin- ear optimal filtering. We successfully apply our chosen approach to compute the electrothermal feedback energy deficit (the "Joule energy") of a pulse, which has been proposed as a linear estimator of the deposited photon energy.
We consider how to analyze microcalorimeter pulses for quantities that are nonlinear in the data, while preserving the signal-to-noise advantages of lin- ear optimal filtering. We successfully apply our chosen approach to compute the electrothermal feedback energy deficit (the "Joule energy") of a pulse, which has been proposed as a linear estimator of the deposited photon energy.
△ Less
Submitted 6 March, 2018;
originally announced March 2018.
-
Results from the Atacama B-mode Search (ABS) Experiment
Authors:
Akito Kusaka,
John Appel,
Thomas Essinger-Hileman,
James A. Beall,
Luis E. Campusano,
Hsiao-Mei Cho,
Steve K. Choi,
Kevin Crowley,
Joseph W. Fowler,
Patricio Gallardo,
Matthew Hasselfield,
Gene Hilton,
Shuay-Pwu P. Ho,
Kent Irwin,
Norman Jarosik,
Michael D. Niemack,
Glen W. Nixon,
Michael Nolta,
Lyman A. Page Jr,
Gonzalo A. Palma,
Lucas Parker,
Srinivasan Raghunathan,
Carl D. Reintsema,
Jonathan Sievers,
Sara M. Simon
, et al. (3 additional authors not shown)
Abstract:
The Atacama B-mode Search (ABS) is an experiment designed to measure cosmic microwave background (CMB) polarization at large angular scales ($\ell>40$). It operated from the ACT site at 5190~m elevation in northern Chile at 145 GHz with a net sensitivity (NEQ) of 41 $μ$K$\sqrt{\rm s}$. It employed an ambient-temperature sapphire half-wave plate rotating at 2.55 Hz to modulate the incident polariza…
▽ More
The Atacama B-mode Search (ABS) is an experiment designed to measure cosmic microwave background (CMB) polarization at large angular scales ($\ell>40$). It operated from the ACT site at 5190~m elevation in northern Chile at 145 GHz with a net sensitivity (NEQ) of 41 $μ$K$\sqrt{\rm s}$. It employed an ambient-temperature sapphire half-wave plate rotating at 2.55 Hz to modulate the incident polarization signal and reduce systematic effects. We report here on the analysis of data from a 2400 deg$^2$ patch of sky centered at declination $-42^\circ$ and right ascension $25^\circ$. We perform a blind analysis. After unblinding, we find agreement with the Planck TE and EE measurements on the same region of sky. We marginally detect polarized dust emission and give an upper limit on the tensor-to-scalar ratio of $r<2.3$ (95% cl) with the equivalent of 100 on-sky days of observation. We also present a new measurement of the polarization of Tau A and introduce new methods associated with HWP-based observations.
△ Less
Submitted 3 January, 2018;
originally announced January 2018.
-
Microstructure analysis of bismuth absorbers for transition-edge sensor X-ray microcalorimeters
Authors:
Daikang Yan,
Ralu Divan,
Lisa M. Gades,
Peter Kenesei,
Timothy J. Madden,
Antonino Miceli,
Jun-Sang Park,
Umeshkumar M. Patel,
Orlando Quaranta,
Hemant Sharma,
Douglas A. Bennett,
William B. Doriese,
Joseph W. Fowler,
Johnathon Gard,
James Hays-Wehle,
Kelsey M. Morgan,
Daniel R. Schmidt,
Daniel S. Swetz,
Joel N. Ullom
Abstract:
Transition-edge sensors (TESs) as microcalorimeters offer high resolving power, owning to their sharp response and low operating temperature. In the hard X-ray regime and above, the demand for high quantum-efficiency requires the use of absorbers. Bismuth (Bi), owing to its low heat carrier density and high X-ray stop** power, has been widely used as an absorber material for TESs. However, disti…
▽ More
Transition-edge sensors (TESs) as microcalorimeters offer high resolving power, owning to their sharp response and low operating temperature. In the hard X-ray regime and above, the demand for high quantum-efficiency requires the use of absorbers. Bismuth (Bi), owing to its low heat carrier density and high X-ray stop** power, has been widely used as an absorber material for TESs. However, distinct spectral responses have been observed for Bi absorbers deposited via evaporation versus electroplating. Evaporated Bi absorbers are widely observed to have a non-Gaussian tail on the low energy side of measured spectra. In this study, we fabricated Bi absorbers via these two methods, and performed microstructure analysis using scanning electron microscopy (SEM) and X-ray diffraction microscopy. The two types of material showed the same crystallographic structure, but the grain size of the evaporated Bi was about 40 times smaller than that of the electroplated Bi. This distinction in grain size is likely to be the cause of their different spectral responses.
△ Less
Submitted 6 November, 2017;
originally announced November 2017.
-
Eliminating the non-Gaussian spectral response of X-ray absorbers for transition-edge sensors
Authors:
Daikang Yan,
Ralu Divan,
Lisa M. Gades,
Peter Kenesei,
Timothy J. Madden,
Antonino Miceli,
Jun-Sang Park,
Umeshkumar M. Patel,
Orlando Quaranta,
Hemant Sharma,
Douglas A. Bennett,
William B. Doriese,
Joseph W. Fowler,
Johnathon Gard,
James Hays-Wehle,
Kelsey M. Morgan,
Daniel R. Schmidt,
Daniel S. Swetz,
Joel N. Ullom
Abstract:
Transition-edge sensors (TES) as microcalorimeters for high-energy-resolution X-ray spectroscopy are often fabricated with an absorber made of materials with high Z (for X-ray stop** power) and low heat capacity (for high resolving power). Bismuth represents one of the most compelling options. TESs with evaporated bismuth absorbers have shown spectra with undesirable and unexplained low-energy t…
▽ More
Transition-edge sensors (TES) as microcalorimeters for high-energy-resolution X-ray spectroscopy are often fabricated with an absorber made of materials with high Z (for X-ray stop** power) and low heat capacity (for high resolving power). Bismuth represents one of the most compelling options. TESs with evaporated bismuth absorbers have shown spectra with undesirable and unexplained low-energy tails. We have developed TESs with electroplated bismuth absorbers over a gold layer that are not afflicted by this problem and that retain the other positive aspects of this material. To better understand these phenomena, we have studied a series of TESs with gold, gold/evaporated bismuth, and gold/electroplated bismuth absorbers, fabricated on the same die with identical thermal coupling. We show that bismuth morphology is linked to the spectral response of X-ray TES microcalorimeters.
△ Less
Submitted 28 August, 2017;
originally announced August 2017.
-
L-Edge Spectroscopy of Dilute, Radiation-Sensitive Systems Using a Transition-Edge-Sensor Array
Authors:
Charles J. Titus,
Michael L. Baker,
Sang Jun Lee,
Hsiao-mei Cho,
William B. Doriese,
Joseph W. Fowler,
Kelly Gaffney,
Johnathon D. Gard,
Gene C. Hilton,
Chris Kenney,
Jason Knight,
Dale Li,
Ron Marks,
Michael P. Minitti,
Kelsey M. Morgan,
Galen C. O'Neil,
Carl D. Reintsema,
Daniel R. Schmidt,
Dimosthenis Sokaras,
Daniel S. Swetz,
Joel N. Ullom,
Tsu-Chien Weng,
Christopher Williams,
Betty A. Young,
Kent D. Irwin
, et al. (2 additional authors not shown)
Abstract:
We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100-2000eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in ag…
▽ More
We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100-2000eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in agreement with high-concentration measurements recorded by conventional grating-based spectrometers. These results show that soft X-ray RIXS spectroscopy acquired by high-throughput TES spectrometers can be used to study the local electronic structure of dilute metal-centered complexes relevant to biology, chemistry and catalysis. In particular, TES spectrometers have a unique ability to characterize frozen solutions of radiation- and temperature-sensitive samples.
△ Less
Submitted 18 August, 2017; v1 submitted 29 June, 2017;
originally announced June 2017.
-
A Reassessment of Absolute Energies of the X-ray L Lines of Lanthanide Metals
Authors:
J. W. Fowler,
B. K. Alpert,
D. A. Bennett,
W. B. Doriese,
J. D. Gard,
G. C. Hilton,
L. T. Hudson,
Y. -I. Joe,
K. M. Morgan,
G. C. O'Neil,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
C. I. Szabo,
J. N. Ullom.
Abstract:
We introduce a new technique for determining x-ray fluorescence line energies and widths, and we present measurements made with this technique of 22 x-ray L lines from lanthanide-series elements. The technique uses arrays of transition-edge sensors, microcalorimeters with high energy-resolving power that simultaneously observe both calibrated x-ray standards and the x-ray emission lines under stud…
▽ More
We introduce a new technique for determining x-ray fluorescence line energies and widths, and we present measurements made with this technique of 22 x-ray L lines from lanthanide-series elements. The technique uses arrays of transition-edge sensors, microcalorimeters with high energy-resolving power that simultaneously observe both calibrated x-ray standards and the x-ray emission lines under study. The uncertainty in absolute line energies is generally less than 0.4 eV in the energy range of 4.5 keV to 7.5 keV. Of the seventeen line energies of neodymium, samarium, and holmium, thirteen are found to be consistent with the available x-ray reference data measured after 1990; only two of the four lines for which reference data predate 1980, however, are consistent with our results. Five lines of terbium are measured with uncertainties that improve on those of existing data by factors of two or more. These results eliminate a significant discrepancy between measured and calculated x-ray line energies for the terbium Ll line (5.551 keV). The line widths are also measured, with uncertainties of 0.6 eV or less on the full-width at half-maximum in most cases. These measurements were made with an array of approximately one hundred superconducting x- ray microcalorimeters, each sensitive to an energy band from 1 keV to 8 keV. No energy-dispersive spectrometer has previously been used for absolute-energy estimation at this level of accuracy. Future spectrometers, with superior linearity and energy resolution, will allow us to improve on these results and expand the measurements to more elements and a wider range of line energies.
△ Less
Submitted 10 May, 2017; v1 submitted 1 February, 2017;
originally announced February 2017.
-
When "Optimal Filtering" Isn't
Authors:
J. W. Fowler,
B. K. Alpert,
W. B. Doriese,
J. Hays-Wehle,
Y. -I. Joe,
K. M. Morgan,
G. C. O'Neil,
C. D. Reintsema,
D. R. Schmidt,
J. N. Ullom,
D. S. Swetz
Abstract:
The so-called "optimal filter" analysis of a microcalorimeter's x-ray pulses is statistically optimal only if all pulses have the same shape, regardless of energy. The shapes of pulses from a nonlinear detector can and do depend on the pulse energy, however. A pulse-fitting procedure that we call "tangent filtering" accounts for the energy dependence of the shape and should therefore achieve super…
▽ More
The so-called "optimal filter" analysis of a microcalorimeter's x-ray pulses is statistically optimal only if all pulses have the same shape, regardless of energy. The shapes of pulses from a nonlinear detector can and do depend on the pulse energy, however. A pulse-fitting procedure that we call "tangent filtering" accounts for the energy dependence of the shape and should therefore achieve superior energy resolution. We take a geometric view of the pulse-fitting problem and give expressions to predict how much the energy resolution stands to benefit from such a procedure. We also demonstrate the method with a case study of K-line fluorescence from several 3d transition metals. The method improves the resolution from 4.9 eV to 4.2 eV at the Cu K$α$ line (8.0keV).
△ Less
Submitted 23 November, 2016;
originally announced November 2016.
-
First application of superconducting transition-edge-sensor microcalorimeters to hadronic-atom x-ray spectroscopy
Authors:
S. Okada,
D. A. Bennett,
C. Curceanu,
W. B. Doriese,
J. W. Fowler,
J. Gard,
F. P. Gustafsson,
T. Hashimoto,
R. S. Hayano,
S. Hirenzaki,
J. P. Hays-Wehle,
G. C. Hilton,
N. Ikeno,
M. Iliescu,
S. Ishimoto,
K. Itahashi,
M. Iwasaki,
T. Koike,
K. Kuwabara,
Y. Ma,
J. Marton,
H. Noda,
G. C. O'Neil,
H. Outa,
C. D. Reintsema
, et al. (13 additional authors not shown)
Abstract:
High-resolution pionic-atom x-ray spectroscopy was performed with an x-ray spectrometer based on a 240-pixel array of superconducting transition-edge-sensor (TES) microcalorimeters at the piM1 beam line of the Paul Scherrer Institute. X-rays emitted by pionic carbon via the 4f->3d transition and the parallel 4d->3p transition were observed with a full-width-at-half-maximum energy resolution of 6.8…
▽ More
High-resolution pionic-atom x-ray spectroscopy was performed with an x-ray spectrometer based on a 240-pixel array of superconducting transition-edge-sensor (TES) microcalorimeters at the piM1 beam line of the Paul Scherrer Institute. X-rays emitted by pionic carbon via the 4f->3d transition and the parallel 4d->3p transition were observed with a full-width-at-half-maximum energy resolution of 6.8 eV at 6.4 keV. Measured x-ray energies are consistent with calculated electromagnetic values which considered the strong-interaction effect assessed via the Seki-Masutani potential for the 3p energy level, and favor the electronic population of two filled 1s electrons in the K-shell. Absolute energy calibration with an uncertainty of 0.1 eV was demonstrated under a high-rate hadron beam condition of 1.45 MHz. This is the first application of a TES spectrometer to hadronic-atom x-ray spectroscopy and is an important milestone towards next-generation high-resolution kaonic-atom x-ray spectroscopy.
△ Less
Submitted 18 August, 2016;
originally announced August 2016.
-
The Atacama Cosmology Telescope: The polarization-sensitive ACTPol instrument
Authors:
R. J. Thornton,
P. A. R. Ade,
S. Aiola,
F. E. Angile,
M. Amiri,
J. A. Beall,
D. T. Becker,
H-M. Cho,
S. K. Choi,
P. Corlies,
K. P. Coughlin,
R. Datta,
M. J. Devlin,
S. R. Dicker,
R. Dunner,
J. W. Fowler,
A. E. Fox,
P. A. Gallardo,
J. Gao,
E. Grace,
M. Halpern,
M. Hasselfield,
S. W. Henderson,
G. C. Hilton,
A. D. Hincks
, et al. (31 additional authors not shown)
Abstract:
The Atacama Cosmology Telescope (ACT) is designed to make high angular resolution measurements of anisotropies in the Cosmic Microwave Background (CMB) at millimeter wavelengths. We describe ACTPol, an upgraded receiver for ACT, which uses feedhorn-coupled, polarization-sensitive detector arrays, a 3 degree field of view, 100 mK cryogenics with continuous cooling, and meta material anti-reflection…
▽ More
The Atacama Cosmology Telescope (ACT) is designed to make high angular resolution measurements of anisotropies in the Cosmic Microwave Background (CMB) at millimeter wavelengths. We describe ACTPol, an upgraded receiver for ACT, which uses feedhorn-coupled, polarization-sensitive detector arrays, a 3 degree field of view, 100 mK cryogenics with continuous cooling, and meta material anti-reflection coatings. ACTPol comprises three arrays with separate cryogenic optics: two arrays at a central frequency of 148 GHz and one array operating simultaneously at both 97 GHz and 148 GHz. The combined instrument sensitivity, angular resolution, and sky coverage are optimized for measuring angular power spectra, clusters via the thermal Sunyaev-Zel'dovich and kinetic Sunyaev-Zel'dovich signals, and CMB lensing due to large scale structure. The receiver was commissioned with its first 148 GHz array in 2013, observed with both 148 GHz arrays in 2014, and has recently completed its first full season of operations with the full suite of three arrays. This paper provides an overview of the design and initial performance of the receiver and related systems.
△ Less
Submitted 20 May, 2016;
originally announced May 2016.
-
The bandmerged Planck Early Release Compact Source Catalogue: Probing sub-structure in the molecular gas at high Galactic latitude
Authors:
Xi Chen,
Ranga-Ram Chary,
Timothy J. Pearson,
Peregrine McGehee,
John W. Fowler,
George Helou
Abstract:
The Planck Early Release Compact Source Catalogue (ERCSC) includes nine lists of highly reliable sources, individually extracted at each of the nine Planck frequency channels. To facilitate the study of the Planck sources, especially their spectral behaviour across the radio/infrared frequencies, we provide a "bandmerged" catalogue of the ERCSC sources. This catalogue consists of 15191 entries, wi…
▽ More
The Planck Early Release Compact Source Catalogue (ERCSC) includes nine lists of highly reliable sources, individually extracted at each of the nine Planck frequency channels. To facilitate the study of the Planck sources, especially their spectral behaviour across the radio/infrared frequencies, we provide a "bandmerged" catalogue of the ERCSC sources. This catalogue consists of 15191 entries, with 79 sources detected in all nine frequency channels of Planck and 6818 sources detected in only one channel. We describe the bandmerging algorithm, including the various steps used to disentangle sources in confused regions. The multi-frequency matching allows us to develop spectral energy distributions of sources between 30 and 857 GHz, in particular across the 100 GHz band, where the energetically important CO J=1->0 line enters the Planck bandpass. We find ~3-5sigma evidence for contribution to the 100 GHz intensity from foreground CO along the line of sight to 147 sources with |b|>30 deg. The median excess contribution is 4.5+/-0.9 percent of their measured 100 GHz flux density which cannot be explained by calibration or beam uncertainties. This translates to 0.5+/-0.1 K km s^{-1} of CO which must be clumped on the scale of the Planck 100 GHz beam, i.e., ~10 arcmin. If this is due to a population of low mass (~15 Msun) molecular gas clumps, the total mass in these clumps may be more than 2000 Msun. Further, high-spatial-resolution, ground-based observations of the high-latitude sky will help shed light on the origin of this diffuse, clumpy CO emission.
△ Less
Submitted 24 February, 2016;
originally announced February 2016.
-
Development of microwave-multiplexed superconductive detectors for the HOLMES experiment
Authors:
A. Giachero,
D. Becker,
D. A. Bennett,
M. Faverzani,
E. Ferri,
J. W. Fowler,
J. D. Gard,
J. P. Hays-Wehle,
G. C. Hilton,
M. Maino,
J. A. B Mates,
A. Puiu,
A. Nucciotti,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R Vale
Abstract:
In recent years, the progress on low temperature detector technologies has allowed design of large scale experiments aiming at pushing down the sensitivity on the neutrino mass below 1\,eV. Even with outstanding performances in both energy ($\sim$eV on keV) and time resolution ($\sim 1\,μ$s) on the single channel, a large number of detectors working in parallel is required to reach a sub-eV sensit…
▽ More
In recent years, the progress on low temperature detector technologies has allowed design of large scale experiments aiming at pushing down the sensitivity on the neutrino mass below 1\,eV. Even with outstanding performances in both energy ($\sim$eV on keV) and time resolution ($\sim 1\,μ$s) on the single channel, a large number of detectors working in parallel is required to reach a sub-eV sensitivity. HOLMES is a new experiment to directly measure the neutrino mass with a sensitivity as low as 2\,eV. HOLMES will perform a calorimetric measurement of the energy released in the electron capture (EC) decay of 163Ho. In its final configuration, HOLMES will deploy 1000 detectors of low temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Transition Edge Sensors) on SiN\textsubscript{x} membrane with gold absorbers. The readout is based on the use of rf-SQUIDs as input devices with flux ramp modulation for linearization purposes; the rf-SQUID is then coupled to a superconducting lambda/4-wave resonator in the GHz range, and the modulated signal is finally read out using the homodyne technique. The TES detectors have been designed with the aim of achieving an energy resolution of a few eV at the spectrum endpoint and a time resolution of a few micro-seconds, in order to minimize pile-up artifacts.
△ Less
Submitted 18 January, 2016; v1 submitted 15 January, 2016;
originally announced January 2016.
-
Absolute Energy Calibration of X-ray TESs with 0.04 eV Uncertainty at 6.4 keV in a Hadron-Beam Environment
Authors:
H. Tatsuno,
W. B. Doriese,
D. A. Bennett,
C. Curceanu,
J. W. Fowler,
J. Gard,
F. P. Gustafsson,
T. Hashimoto,
R. S. Hayano,
J. P. Hays-Wehle,
G. C. Hilton,
M. Iliescu,
S. Ishimoto,
K. Itahashi,
M. Iwasaki,
K. Kuwabara,
Y. Ma,
J. Marton,
H. Noda,
G. C. O'Neil,
S. Okada,
H. Outa,
C. D. Reintsema,
M. Sato,
D. R. Schmidt
, et al. (9 additional authors not shown)
Abstract:
A performance evaluation of superconducting transition-edge sensors (TESs) in the environment of a pion beam line at a particle accelerator is presented. Averaged across the 209 functioning sensors in the array, the achieved energy resolution is 5.2 eV FWHM at Co $K_α$ (6.9 keV) when the pion beam is off and 7.3 eV at a beam rate of 1.45 MHz. Absolute energy uncertainty of $\pm$0.04 eV is demonstr…
▽ More
A performance evaluation of superconducting transition-edge sensors (TESs) in the environment of a pion beam line at a particle accelerator is presented. Averaged across the 209 functioning sensors in the array, the achieved energy resolution is 5.2 eV FWHM at Co $K_α$ (6.9 keV) when the pion beam is off and 7.3 eV at a beam rate of 1.45 MHz. Absolute energy uncertainty of $\pm$0.04 eV is demonstrated for Fe $K_α$ (6.4 keV) with in-situ energy calibration obtained from other nearby known x-ray lines. To achieve this small uncertainty, it is essential to consider the non-Gaussian energy response of the TESs and thermal cross-talk pile-up effects due to charged-particle hits in the silicon substrate of the TES array.
△ Less
Submitted 13 January, 2016;
originally announced January 2016.
-
The Practice of Pulse Processing
Authors:
J. W. Fowler,
B. K. Alpert,
W. B. Doriese,
Y. -I. Joe,
G. C. O'Neil,
J. N. Ullom,
D. S. Swetz
Abstract:
The analysis of data from x-ray microcalorimeters requires great care; their excellent intrinsic energy resolution cannot usually be achieved in practice without a statistically near-optimal pulse analysis and corrections for important systematic errors. We describe the essential parts of a pulse-analysis pipeline for data from x-ray microcalorimeters, including steps taken to reduce systematic ga…
▽ More
The analysis of data from x-ray microcalorimeters requires great care; their excellent intrinsic energy resolution cannot usually be achieved in practice without a statistically near-optimal pulse analysis and corrections for important systematic errors. We describe the essential parts of a pulse-analysis pipeline for data from x-ray microcalorimeters, including steps taken to reduce systematic gain variation and the unwelcome dependence of filtered pulse heights on the exact pulse-arrival time. We find these steps collectively to be essential tools for getting the best results from a microcalorimeter-based x-ray spectrometer.
△ Less
Submitted 12 November, 2015;
originally announced November 2015.
-
Microcalorimeter Spectroscopy at High Pulse Rates: a Multi-Pulse Fitting Technique
Authors:
J. W. Fowler,
B. K. Alpert,
W. B. Doriese,
D. A. Fischer,
C. Jaye,
Y. I. Joe,
G. C. O'Neil,
D. S. Swetz,
J. N. Ullom
Abstract:
Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each sensor must be able to measure hundreds or even thousands of photon energies per second. Current "optimal filtering" approaches to achieve the best possible energ…
▽ More
Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each sensor must be able to measure hundreds or even thousands of photon energies per second. Current "optimal filtering" approaches to achieve the best possible energy resolution work only for photons well isolated in time, a requirement in direct conflict with the need for high-rate measurements. We describe a new analysis procedure to allow fitting for the pulse height of all photons even in the presence of heavy pulse pile-up. In the limit of isolated pulses, the technique reduces to the standard optimal filtering with long records. We employ reasonable approximations to the noise covariance function in order to render multi-pulse fitting computationally viable even for very long data records. The technique is employed to analyze x-ray emission spectra at 600 eV and 6 keV at rates up to 250 counts per second in microcalorimeters having exponential signal decay times of approximately 1.2 ms.
△ Less
Submitted 31 March, 2015; v1 submitted 20 March, 2015;
originally announced March 2015.
-
The Atacama Cosmology Telescope: CMB Polarization at $200<\ell<9000$
Authors:
Sigurd Naess,
Matthew Hasselfield,
Jeff McMahon,
Michael D. Niemack,
Graeme E. Addison,
Peter A. R. Ade,
Rupert Allison,
Mandana Amiri,
Nick Battaglia,
James A. Beall,
Francesco de Bernardis,
J Richard Bond,
Joe Britton,
Erminia Calabrese,
Hsiao-mei Cho,
Kevin Coughlin,
Devin Crichton,
Sudeep Das,
Rahul Datta,
Mark J. Devlin,
Simon R. Dicker,
Joanna Dunkley,
Rolando Dünner,
Joseph W. Fowler,
Anna E. Fox
, et al. (53 additional authors not shown)
Abstract:
We report on measurements of the cosmic microwave background (CMB) and celestial polarization at 146 GHz made with the Atacama Cosmology Telescope Polarimeter (ACTPol) in its first three months of observing. Four regions of sky covering a total of 270 square degrees were mapped with an angular resolution of $1.3'$. The map noise levels in the four regions are between 11 and 17 $μ$K-arcmin. We pres…
▽ More
We report on measurements of the cosmic microwave background (CMB) and celestial polarization at 146 GHz made with the Atacama Cosmology Telescope Polarimeter (ACTPol) in its first three months of observing. Four regions of sky covering a total of 270 square degrees were mapped with an angular resolution of $1.3'$. The map noise levels in the four regions are between 11 and 17 $μ$K-arcmin. We present TT, TE, EE, TB, EB, and BB power spectra from three of these regions. The observed E-mode polarization power spectrum, displaying six acoustic peaks in the range $200<\ell<3000$, is an excellent fit to the prediction of the best-fit cosmological models from WMAP9+ACT and Planck data. The polarization power spectrum, which mainly reflects primordial plasma velocity perturbations, provides an independent determination of cosmological parameters consistent with those based on the temperature power spectrum, which results mostly from primordial density perturbations. We find that without masking any point sources in the EE data at $\ell<9000$, the Poisson tail of the EE power spectrum due to polarized point sources has an amplitude less than $2.4$ $μ$K$^2$ at $\ell = 3000$ at 95\% confidence. Finally, we report that the Crab Nebula, an important polarization calibration source at microwave frequencies, has 8.7\% polarization with an angle of $150.7^\circ \pm 0.6^\circ$ when smoothed with a $5'$ Gaussian beam.
△ Less
Submitted 21 September, 2014; v1 submitted 21 May, 2014;
originally announced May 2014.
-
The AllWISE Motion Survey and The Quest for Cold Subdwarfs
Authors:
J. Davy Kirkpatrick,
Adam Schneider,
Sergio Fajardo-Acosta,
Christopher R. Gelino,
Gregory N. Mace,
Edward L. Wright,
Sarah E. Logsdon,
Ian S. McLean,
Michael C. Cushing,
Michael F. Skrutskie,
Peter R. Eisenhardt,
Daniel Stern,
Mislav Balokovic,
Adam J. Burgasser,
Jacqueline K. Faherty,
George B. Lansbury,
J. A. Rich,
Nathalie Skrzypek,
John W. Fowler,
Roc M. Cutri,
Frank J. Masci,
Tim Conrow,
Carl J. Grillmair,
Howard L. McCallon,
Charles A. Beichman
, et al. (1 additional authors not shown)
Abstract:
The AllWISE processing pipeline has measured motions for all objects detected on WISE images taken between 2010 January and 2011 February. In this paper, we discuss new capabilities made to the software pipeline in order to make motion measurements possible, and we characterize the resulting data products for use by future researchers. Using a stringent set of selection criteria, we find 22,445 ob…
▽ More
The AllWISE processing pipeline has measured motions for all objects detected on WISE images taken between 2010 January and 2011 February. In this paper, we discuss new capabilities made to the software pipeline in order to make motion measurements possible, and we characterize the resulting data products for use by future researchers. Using a stringent set of selection criteria, we find 22,445 objects that have significant AllWISE motions, of which 3,525 have motions that can be independently confirmed from earlier 2MASS images yet lack any published motions in SIMBAD. Another 58 sources lack 2MASS counterparts and are presented as motion candidates only. Limited spectroscopic follow-up of this list has already revealed eight new L subdwarfs. These may provide the first hints of a "subdwarf gap" at mid-L types that would indicate the break between the stellar and substellar populations at low metallicities (i.e., old ages). Another object in the motion list -- WISEA J154045.67-510139.3 -- is a bright (J ~ 9 mag) object of type M6; both the spectrophotometric distance and a crude preliminary parallax place it ~6 pc from the Sun. We also compare our list of motion objects to the recently published list of 762 WISE motion objects from Luhman (2014). While these first large motion studies with WISE data have been very successful in revealing previously overlooked nearby dwarfs, both studies missed objects that the other found, demonstrating that many other nearby objects likely await discovery in the AllWISE data products.
△ Less
Submitted 4 February, 2014;
originally announced February 2014.
-
High-resolution kaonic-atom x-ray spectroscopy with transition-edge-sensor microcalorimeters
Authors:
S. Okada,
D. A. Bennett,
W. B. Doriese,
J. W. Fowler,
K. D. Irwin,
S. Ishimoto,
M. Sato,
D. R. Schmidt,
D. S. Swetz,
H. Tatsuno,
J. N. Ullom,
S. Yamada
Abstract:
We are preparing for an ultra-high resolution x-ray spectroscopy of kaonic atoms using an x-ray spectrometer based on an array of superconducting transition-edge-sensor microcalorimeters developed by NIST. The instrument has excellent energy resolutions of 2 - 3 eV (FWHM) at 6 keV and a large collecting area of about 20 mm^2. This will open new door to investigate kaon-nucleus strong interaction a…
▽ More
We are preparing for an ultra-high resolution x-ray spectroscopy of kaonic atoms using an x-ray spectrometer based on an array of superconducting transition-edge-sensor microcalorimeters developed by NIST. The instrument has excellent energy resolutions of 2 - 3 eV (FWHM) at 6 keV and a large collecting area of about 20 mm^2. This will open new door to investigate kaon-nucleus strong interaction and provide new accurate charged-kaon mass value.
△ Less
Submitted 18 February, 2014; v1 submitted 30 January, 2014;
originally announced January 2014.
-
Maximum-likelihood fits to histograms for improved parameter estimation
Authors:
Joseph W. Fowler
Abstract:
Straightforward methods for adapting the familiar chi^2 statistic to histograms of discrete events and other Poisson distributed data generally yield biased estimates of the parameters of a model. The bias can be important even when the total number of events is large. For the case of estimating a microcalorimeter's energy resolution at 6 keV from the observed shape of the Mn K-alpha fluorescence…
▽ More
Straightforward methods for adapting the familiar chi^2 statistic to histograms of discrete events and other Poisson distributed data generally yield biased estimates of the parameters of a model. The bias can be important even when the total number of events is large. For the case of estimating a microcalorimeter's energy resolution at 6 keV from the observed shape of the Mn K-alpha fluorescence spectrum, a poor choice of chi^2 can lead to biases of at least 10% in the estimated resolution when up to thousands of photons are observed. The best remedy is a Poisson maximum-likelihood fit, through a simple modification of the standard Levenberg-Marquardt algorithm for chi^2 minimization. Where the modification is not possible, another approach allows iterative approximation of the maximum-likelihood fit.
△ Less
Submitted 19 December, 2013;
originally announced December 2013.
-
High-resolution gamma-ray spectroscopy with a microwave-multiplexed transition-edge sensor array
Authors:
Omid Noroozian,
John A. B. Mates,
Douglas A. Bennett,
Justus A. Brevik,
Joseph W. Fowler,
Jiansong Gao,
Gene C. Hilton,
Robert D. Horansky,
Kent D. Irwin,
Zhao Kang,
Daniel R. Schmidt,
Leila R. Vale,
Joel N. Ullom
Abstract:
We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of superconducting microwave resonators co…
▽ More
We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of superconducting microwave resonators coupled to radio-frequency superconducting-quantum-interference-devices (SQUID) and transduces changes in input current to changes in phase of a microwave signal. We use flux-ramp modulation to linearize the response and evade low-frequency noise. This demonstration establishes one path for the readout of cryogenic X-ray and gamma-ray sensor arrays with more than $10^3$ elements and spectral resolving powers $R=λ/Δλ> 10^3$.
△ Less
Submitted 27 October, 2013;
originally announced October 2013.
-
Cross-training with Imperfect training Schemes
Authors:
Burak Buke,
Ozgur M. Araz,
John W. Fowler
Abstract:
Cross-training workers is one of the most efficient ways to achieve flexibility in manufacturing and service systems to increase responsiveness to demand variability. However, it is generally the case that cross-trained employees are not as productive as employees who are originally trained on a specific task. Also, the productivity of the cross-trained workers depend on when they are cross-traine…
▽ More
Cross-training workers is one of the most efficient ways to achieve flexibility in manufacturing and service systems to increase responsiveness to demand variability. However, it is generally the case that cross-trained employees are not as productive as employees who are originally trained on a specific task. Also, the productivity of the cross-trained workers depend on when they are cross-trained. In this work, we consider a two-stage model to analyze the affect of variations in productivity levels of workers on cross-training policies. Our results indicate that the most important factor determining the problem structure is the consistency in productivity levels of workers trained at different times. As long as cross-training can be done in a consistent manner, the productivity differences between cross-trained workers and workers originally trained on the task plays a minor role. We also analyze the effect of the variabilities in demand and producivity levels. We show that if the productivity levels of workers trained at different times are consistent, the decision maker is inclined to defer the cross-training decisions as the variability of demand or productivity levels increases. However, when the productivities of workers trained at different times differ, the decision maker may prefer to invest more in cross-training earlier as variability increases.
△ Less
Submitted 26 August, 2013;
originally announced August 2013.
-
The Atacama Cosmology Telescope: Beam Measurements and the Microwave Brightness Temperatures of Uranus and Saturn
Authors:
Matthew Hasselfield,
Kavilan Moodley,
J. Richard Bond,
Sudeep Das,
Mark J. Devlin,
Joanna Dunkley,
Rolando Dunner,
Joseph W. Fowler,
Patricio Gallardo,
Megan B. Gralla,
Amir Hajian,
Mark Halpern,
Adam D. Hincks,
Tobias A. Marriage,
Danica Marsden,
Michael D. Niemack,
Michael R. Nolta,
Lyman A. Page,
Bruce Partridge,
Benjamin L. Schmitt,
Neelima Sehgal,
Jon Sievers,
Suzanne T. Staggs,
Daniel S. Swetz,
Eric R. Switzer
, et al. (1 additional authors not shown)
Abstract:
We describe the measurement of the beam profiles and window functions for the Atacama Cosmology Telescope (ACT), which operated from 2007 to 2010 with kilo-pixel bolometer arrays centered at 148, 218, and 277 GHz. Maps of Saturn are used to measure the beam shape in each array and for each season of observations. Radial profiles are transformed to Fourier space in a way that preserves the spatial…
▽ More
We describe the measurement of the beam profiles and window functions for the Atacama Cosmology Telescope (ACT), which operated from 2007 to 2010 with kilo-pixel bolometer arrays centered at 148, 218, and 277 GHz. Maps of Saturn are used to measure the beam shape in each array and for each season of observations. Radial profiles are transformed to Fourier space in a way that preserves the spatial correlations in the beam uncertainty, to derive window functions relevant for angular power spectrum analysis. Several corrections are applied to the resulting beam transforms, including an empirical correction measured from the final CMB survey maps to account for the effects of mild pointing variation and alignment errors. Observations of Uranus made regularly throughout each observing season are used to measure the effects of atmospheric opacity and to monitor deviations in telescope focus over the season. Using the WMAP-based calibration of the ACT maps to the CMB blackbody, we obtain precise measurements of the brightness temperatures of the Uranus and Saturn disks at effective frequencies of 149 and 219 GHz. For Uranus we obtain thermodynamic brightness temperatures T_U^{149} = 106.7 \pm 2.2 K and T_U^{219} = 100.1 \pm 3.1 K. For Saturn, we model the effects of the ring opacity and emission using a simple model and obtain resulting (unobscured) disk temperatures of T_S^{149} = 137.3 \pm 3.2 K and T_S^{219} = 137.3 \pm 4.7 K.
△ Less
Submitted 19 March, 2013;
originally announced March 2013.
-
The Atacama Cosmology Telescope: Temperature and Gravitational Lensing Power Spectrum Measurements from Three Seasons of Data
Authors:
Sudeep Das,
Thibaut Louis,
Michael R. Nolta,
Graeme E. Addison,
Elia S. Battistelli,
J Richard Bond,
Erminia Calabrese,
Devin Crichton Mark J. Devlin,
Simon Dicker,
Joanna Dunkley,
Rolando Dünner,
Joseph W. Fowler,
Megan Gralla,
Amir Hajian,
Mark Halpern,
Matthew Hasselfield,
Matt Hilton,
Adam D. Hincks,
Renée Hlozek,
Kevin M. Huffenberger,
John P. Hughes,
Kent D. Irwin,
Arthur Kosowsky,
Robert H. Lupton,
Tobias A. Marriage
, et al. (18 additional authors not shown)
Abstract:
We present the temperature power spectra of the cosmic microwave background (CMB) derived from the three seasons of data from the Atacama Cosmology Telescope (ACT) at 148 GHz and 218 GHz, as well as the cross-frequency spectrum between the two channels. We detect and correct for contamination due to the Galactic cirrus in our equatorial maps. We present the results of a number of tests for possibl…
▽ More
We present the temperature power spectra of the cosmic microwave background (CMB) derived from the three seasons of data from the Atacama Cosmology Telescope (ACT) at 148 GHz and 218 GHz, as well as the cross-frequency spectrum between the two channels. We detect and correct for contamination due to the Galactic cirrus in our equatorial maps. We present the results of a number of tests for possible systematic error and conclude that any effects are not significant compared to the statistical errors we quote. Where they overlap, we cross-correlate the ACT and the South Pole Telescope (SPT) maps and show they are consistent. The measurements of higher-order peaks in the CMB power spectrum provide an additional test of the Lambda CDM cosmological model, and help constrain extensions beyond the standard model. The small angular scale power spectrum also provides constraining power on the Sunyaev-Zel'dovich effects and extragalactic foregrounds. We also present a measurement of the CMB gravitational lensing convergence power spectrum at 4.6-sigma detection significance.
△ Less
Submitted 2 February, 2013; v1 submitted 6 January, 2013;
originally announced January 2013.
-
The Atacama Cosmology Telescope: Cosmological parameters from three seasons of data
Authors:
Jonathan L. Sievers,
Renée A. Hlozek,
Michael R. Nolta,
Viviana Acquaviva,
Graeme E. Addison,
Peter A. R. Ade,
Paula Aguirre,
Mandana Amiri,
John William Appel,
L. Felipe Barrientos,
Elia S. Battistelli,
Nick Battaglia,
J. Richard Bond,
Ben Brown,
Bryce Burger,
Erminia Calabrese,
Jay Chervenak,
Devin Crichton,
Sudeep Das,
Mark J. Devlin,
Simon R. Dicker,
W. Bertrand Doriese,
Joanna Dunkley,
Rolando Dünner,
Thomas Essinger-Hileman
, et al. (68 additional authors not shown)
Abstract:
We present constraints on cosmological and astrophysical parameters from high-resolution microwave background maps at 148 GHz and 218 GHz made by the Atacama Cosmology Telescope (ACT) in three seasons of observations from 2008 to 2010. A model of primary cosmological and secondary foreground parameters is fit to the map power spectra and lensing deflection power spectrum, including contributions f…
▽ More
We present constraints on cosmological and astrophysical parameters from high-resolution microwave background maps at 148 GHz and 218 GHz made by the Atacama Cosmology Telescope (ACT) in three seasons of observations from 2008 to 2010. A model of primary cosmological and secondary foreground parameters is fit to the map power spectra and lensing deflection power spectrum, including contributions from both the thermal Sunyaev-Zeldovich (tSZ) effect and the kinematic Sunyaev-Zeldovich (kSZ) effect, Poisson and correlated anisotropy from unresolved infrared sources, radio sources, and the correlation between the tSZ effect and infrared sources. The power ell^2 C_ell/2pi of the thermal SZ power spectrum at 148 GHz is measured to be 3.4 +\- 1.4 muK^2 at ell=3000, while the corresponding amplitude of the kinematic SZ power spectrum has a 95% confidence level upper limit of 8.6 muK^2. Combining ACT power spectra with the WMAP 7-year temperature and polarization power spectra, we find excellent consistency with the LCDM model. We constrain the number of effective relativistic degrees of freedom in the early universe to be Neff=2.79 +\- 0.56, in agreement with the canonical value of Neff=3.046 for three massless neutrinos. We constrain the sum of the neutrino masses to be Sigma m_nu < 0.39 eV at 95% confidence when combining ACT and WMAP 7-year data with BAO and Hubble constant measurements. We constrain the amount of primordial helium to be Yp = 0.225 +\- 0.034, and measure no variation in the fine structure constant alpha since recombination, with alpha/alpha0 = 1.004 +/- 0.005. We also find no evidence for any running of the scalar spectral index, dns/dlnk = -0.004 +\- 0.012.
△ Less
Submitted 11 October, 2013; v1 submitted 4 January, 2013;
originally announced January 2013.
-
The Atacama Cosmology Telescope: Sunyaev-Zel'dovich Selected Galaxy Clusters at 148 GHz from Three Seasons of Data
Authors:
Matthew Hasselfield,
Matt Hilton,
Tobias A. Marriage,
Graeme E. Addison,
L. Felipe Barrientos,
Nicholas Battaglia,
Elia S. Battistelli,
J. Richard Bond,
Devin Crichton,
Sudeep Das,
Mark J. Devlin,
Simon R. Dicker,
Joanna Dunkley,
Rolando Dunner,
Joseph W. Fowler,
Megan B. Gralla,
Amir Hajian,
Mark Halpern,
Adam D. Hincks,
Renée Hlozek,
John P. Hughes,
Leopoldo Infante,
Kent D. Irwin,
Arthur Kosowsky,
Danica Marsden
, et al. (19 additional authors not shown)
Abstract:
[Abridged] We present a catalog of 68 galaxy clusters, of which 19 are new discoveries, detected via the Sunyaev-Zel'dovich effect (SZ) at 148 GHz in the Atacama Cosmology Telescope (ACT) survey of 504 square degrees on the celestial equator. A subsample of 48 clusters within the 270 square degree region overlap** SDSS Stripe 82 is estimated to be 90% complete for M_500c > 4.5e14 Msun and 0.15 <…
▽ More
[Abridged] We present a catalog of 68 galaxy clusters, of which 19 are new discoveries, detected via the Sunyaev-Zel'dovich effect (SZ) at 148 GHz in the Atacama Cosmology Telescope (ACT) survey of 504 square degrees on the celestial equator. A subsample of 48 clusters within the 270 square degree region overlap** SDSS Stripe 82 is estimated to be 90% complete for M_500c > 4.5e14 Msun and 0.15 < z < 0.8. While matched filters are used to detect the clusters, the sample is studied further through a "Profile Based Amplitude Analysis" using a single filter at a fixed θ_500 = 5.9' angular scale. This new approach takes advantage of the "Universal Pressure Profile" (UPP) to fix the relationship between the cluster characteristic size (R_500) and the integrated Compton parameter (Y_500). The UPP scalings are found to be nearly identical to an adiabatic model, while a model incorporating non-thermal pressure better matches dynamical mass measurements and masses from the South Pole Telescope. A high signal to noise ratio subsample of 15 ACT clusters is used to obtain cosmological constraints. We first confirm that constraints from SZ data are limited by uncertainty in the scaling relation parameters rather than sample size or measurement uncertainty. We next add in seven clusters from the ACT Southern survey, including their dynamical mass measurements based on galaxy velocity dispersions. In combination with WMAP7 these data simultaneously constrain the scaling relation and cosmological parameters, yielding σ_8 = 0.829 \pm 0.024 and Ω_m = 0.292 \pm 0.025. The results include marginalization over a 15% bias in dynamical mass relative to the true halo mass. In an extension to LCDM that incorporates non-zero neutrino mass density, we combine our data with WMAP7+BAO+Hubble constant measurements to constrain Σm_ν< 0.29 eV (95% C. L.).
△ Less
Submitted 8 July, 2013; v1 submitted 4 January, 2013;
originally announced January 2013.
-
The Atacama Cosmology Telescope: likelihood for small-scale CMB data
Authors:
J. Dunkley,
E. Calabrese,
J. Sievers,
G. E. Addison,
N. Battaglia,
E. S. Battistelli,
J. R. Bond,
S. Das,
M. J. Devlin,
R. Dunner,
J. W. Fowler,
M. Gralla,
A. Hajian,
M. Halpern,
M. Hasselfield,
A. D. Hincks,
R. Hlozek,
J. P. Hughes,
K. D. Irwin,
A. Kosowsky,
T. Louis,
T. A. Marriage,
D. Marsden,
F. Menanteau,
K. Moodley
, et al. (10 additional authors not shown)
Abstract:
The Atacama Cosmology Telescope has measured the angular power spectra of microwave fluctuations to arcminute scales at frequencies of 148 and 218 GHz, from three seasons of data. At small scales the fluctuations in the primordial Cosmic Microwave Background (CMB) become increasingly obscured by extragalactic foregounds and secondary CMB signals. We present results from a nine-parameter model desc…
▽ More
The Atacama Cosmology Telescope has measured the angular power spectra of microwave fluctuations to arcminute scales at frequencies of 148 and 218 GHz, from three seasons of data. At small scales the fluctuations in the primordial Cosmic Microwave Background (CMB) become increasingly obscured by extragalactic foregounds and secondary CMB signals. We present results from a nine-parameter model describing these secondary effects, including the thermal and kinematic Sunyaev-Zel'dovich (tSZ and kSZ) power; the clustered and Poisson-like power from Cosmic Infrared Background (CIB) sources, and their frequency scaling; the tSZ-CIB correlation coefficient; the extragalactic radio source power; and thermal dust emission from Galactic cirrus in two different regions of the sky. In order to extract cosmological parameters, we describe a likelihood function for the ACT data, fitting this model to the multi-frequency spectra in the multipole range 500<ell<10000. We extend the likelihood to include spectra from the South Pole Telescope at frequencies of 95, 150, and 220 GHz. Accounting for different radio source levels and Galactic cirrus emission, the same model provides an excellent fit to both datasets simultaneously, with chi2/dof= 675/697 for ACT, and 96/107 for SPT. We then use the multi-frequency likelihood to estimate the CMB power spectrum from ACT in bandpowers, marginalizing over the secondary parameters. This provides a simplified `CMB-only' likelihood in the range 500<ell<3500 for use in cosmological parameter estimation.
△ Less
Submitted 8 October, 2013; v1 submitted 4 January, 2013;
originally announced January 2013.
-
Filters for High Rate Pulse Processing
Authors:
B. K. Alpert,
R. D. Horansky,
D. A. Bennett,
W. B. Doriese,
J. W. Fowler,
A. S. Hoover,
M. W. Rabin,
J. N. Ullom
Abstract:
We introduce a filter-construction method for pulse processing that differs in two respects from that in standard optimal filtering, in which the average pulse shape and noise-power spectral density are combined to create a convolution filter for estimating pulse heights. First, the proposed filters are computed in the time domain, to avoid periodicity artifacts of the discrete Fourier transform,…
▽ More
We introduce a filter-construction method for pulse processing that differs in two respects from that in standard optimal filtering, in which the average pulse shape and noise-power spectral density are combined to create a convolution filter for estimating pulse heights. First, the proposed filters are computed in the time domain, to avoid periodicity artifacts of the discrete Fourier transform, and second, orthogonality constraints are imposed on the filters, to reduce the filtering procedure's sensitivity to unknown baseline height and pulse tails. We analyze the proposed filters, predicting energy resolution under several scenarios, and apply the filters to high-rate pulse data from gamma-rays measured by a transition-edge-sensor microcalorimeter.
△ Less
Submitted 7 December, 2012;
originally announced December 2012.
-
Saha Equation Normalized to Total Atomic Number Density
Authors:
John W. Fowler
Abstract:
The Saha equation describes the relative number density of consecutive ionization levels of a given atomic species under conditions of thermodynamic equilibrium in an ionized gas. Because the number density in the denominator may be very small, special steps must be taken to ensure numerical stability. In this paper we recast the equation into a form in which each ionization fraction is normalized…
▽ More
The Saha equation describes the relative number density of consecutive ionization levels of a given atomic species under conditions of thermodynamic equilibrium in an ionized gas. Because the number density in the denominator may be very small, special steps must be taken to ensure numerical stability. In this paper we recast the equation into a form in which each ionization fraction is normalized by the total number density of the atomic species, analogous to the Boltzmann equation describing the distribution of excitation states for a given ion.
△ Less
Submitted 28 September, 2012; v1 submitted 5 September, 2012;
originally announced September 2012.
-
The Atacama Cosmology Telescope: Data Characterization and Map Making
Authors:
Rolando Dünner,
Matthew Hasselfield,
Tobias A. Marriage,
Jon Sievers,
Viviana Acquaviva,
Graeme E. Addison,
Peter A. R. Ade,
Paula Aguirre,
Mandana Amiri,
John William Appel,
L. Felipe Barrientos,
Elia S. Battistelli,
J. Richard Bond,
Ben Brown,
Bryce Burger,
Erminia Calabrese,
Jay Chervenak,
Sudeep Das,
Mark J. Devlin,
Simon R. Dicker,
W. Bertrand Doriese,
Joanna Dunkley,
Thomas Essinger-Hileman,
Ryan P. Fisher,
Megan B. Gralla
, et al. (49 additional authors not shown)
Abstract:
We present a description of the data reduction and mapmaking pipeline used for the 2008 observing season of the Atacama Cosmology Telescope (ACT). The data presented here at 148 GHz represent 12% of the 90 TB collected by ACT from 2007 to 2010. In 2008 we observed for 136 days, producing a total of 1423 hours of data (11 TB for the 148 GHz band only), with a daily average of 10.5 hours of observat…
▽ More
We present a description of the data reduction and mapmaking pipeline used for the 2008 observing season of the Atacama Cosmology Telescope (ACT). The data presented here at 148 GHz represent 12% of the 90 TB collected by ACT from 2007 to 2010. In 2008 we observed for 136 days, producing a total of 1423 hours of data (11 TB for the 148 GHz band only), with a daily average of 10.5 hours of observation. From these, 1085 hours were devoted to a 850 deg^2 stripe (11.2 hours by 9.1 deg) centered on a declination of -52.7 deg, while 175 hours were devoted to a 280 deg^2 stripe (4.5 hours by 4.8 deg) centered at the celestial equator. We discuss sources of statistical and systematic noise, calibration, telescope pointing, and data selection. Out of 1260 survey hours and 1024 detectors per array, 816 hours and 593 effective detectors remain after data selection for this frequency band, yielding a 38% survey efficiency. The total sensitivity in 2008, determined from the noise level between 5 Hz and 20 Hz in the time-ordered data stream (TOD), is 32 micro-Kelvin sqrt{s} in CMB units. Atmospheric brightness fluctuations constitute the main contaminant in the data and dominate the detector noise covariance at low frequencies in the TOD. The maps were made by solving the least-squares problem using the Preconditioned Conjugate Gradient method, incorporating the details of the detector and noise correlations. Cross-correlation with WMAP sky maps, as well as analysis from simulations, reveal that our maps are unbiased at multipoles ell > 300. This paper accompanies the public release of the 148 GHz southern stripe maps from 2008. The techniques described here will be applied to future maps and data releases.
△ Less
Submitted 2 August, 2012; v1 submitted 31 July, 2012;
originally announced August 2012.
-
The Atacama Cosmology Telescope: A Measurement of the Thermal Sunyaev-Zel'dovich Effect Using the Skewness of the CMB Temperature Distribution
Authors:
Michael J. Wilson,
Blake D. Sherwin,
J. Colin Hill,
Graeme Addison,
Nick Battaglia,
J. Richard Bond,
Sudeep Das,
Mark J. Devlin,
Joanna Dunkley,
Rolando Dunner,
Joseph W. Fowler,
Megan B. Gralla,
Amir Hajian,
Mark Halpern,
Matt Hilton,
Adam D. Hincks,
Renee Hlozek,
Kevin Huffenberger,
John P. Hughes,
Arthur Kosowsky,
Thibaut Louis,
Tobias A. Marriage,
Danica Marsden,
Felipe Menanteau,
Kavilan Moodley
, et al. (13 additional authors not shown)
Abstract:
We present a detection of the unnormalized skewness <T^3> induced by the thermal Sunyaev-Zel'dovich (tSZ) effect in filtered Atacama Cosmology Telescope (ACT) 148 GHz cosmic microwave background temperature maps. Contamination due to infrared and radio sources is minimized by template subtraction of resolved sources and by constructing a mask using outlying values in the 218 GHz (tSZ-null) ACT map…
▽ More
We present a detection of the unnormalized skewness <T^3> induced by the thermal Sunyaev-Zel'dovich (tSZ) effect in filtered Atacama Cosmology Telescope (ACT) 148 GHz cosmic microwave background temperature maps. Contamination due to infrared and radio sources is minimized by template subtraction of resolved sources and by constructing a mask using outlying values in the 218 GHz (tSZ-null) ACT maps. We measure <T^3>= -31 +- 6 μK^3 (measurement error only) or +- 14 μK^3 (including cosmic variance error) in the filtered ACT data, a 5-sigma detection. We show that the skewness is a sensitive probe of sigma_8, and use analytic calculations and tSZ simulations to obtain cosmological constraints from this measurement. From this signal alone we infer a value of sigma_8= 0.79 +0.03 -0.03 (68 % C.L.) +0.06 -0.06 (95 % C.L.). Our results demonstrate that measurements of non-Gaussianity can be a useful method for characterizing the tSZ effect and extracting the underlying cosmological information.
△ Less
Submitted 20 November, 2012; v1 submitted 29 March, 2012;
originally announced March 2012.