-
Optical and microwave metrology at the 10-18 level with an Er/Yb:glass frequency comb
Authors:
Nicholas V. Nardelli,
Holly Leopardi,
Thomas R. Schibli,
Tara M. Fortier
Abstract:
Optical frequency combs are an essential tool for precision metrology experiments ranging in application from remote spectroscopic sensing of trace gases to the characterization and comparison of optical atomic clocks for precision time-kee** and searches for physics beyond the standard model. Here we describe the architecture and fully characterize a telecom-band, self-modelocking frequency com…
▽ More
Optical frequency combs are an essential tool for precision metrology experiments ranging in application from remote spectroscopic sensing of trace gases to the characterization and comparison of optical atomic clocks for precision time-kee** and searches for physics beyond the standard model. Here we describe the architecture and fully characterize a telecom-band, self-modelocking frequency comb based on a free-space laser with an Er/Yb co-doped glass gain medium. The laser provides a robust and cost-effective alternative to Er:fiber laser based frequency combs, while offering stability and noise performance similar to Ti:sapphire laser systems. Finally, we demonstrate the Er/Yb:glass frequency comb's utility in high-stability frequency synthesis using two ultra-stable optical references at 1157 nm and 1070 nm and in low-noise photonic microwave generation by dividing these references to the microwave domain.
△ Less
Submitted 26 August, 2022;
originally announced August 2022.
-
10 GHz Generation with Ultra-Low Phase Noise via the Transfer Oscillator Technique
Authors:
Nicholas V. Nardelli,
Tara M. Fortier,
Marco Pomponio,
Esther Baumann,
Craig Nelson,
Thomas R. Schibli,
Archita Hati
Abstract:
Coherent frequency division of high-stability optical sources permits the extraction of microwave signals with ultra-low phase noise, enabling their application to systems with stringent timing precision. To date, the highest performance systems have required tight phase stabilization of laboratory grade optical frequency combs to Fabry-Perot optical reference cavities for faithful optical-to-micr…
▽ More
Coherent frequency division of high-stability optical sources permits the extraction of microwave signals with ultra-low phase noise, enabling their application to systems with stringent timing precision. To date, the highest performance systems have required tight phase stabilization of laboratory grade optical frequency combs to Fabry-Perot optical reference cavities for faithful optical-to-microwave frequency division. This requirement limits the technology to highly-controlled laboratory environments. Here, we employ a transfer oscillator technique, which employs digital and RF analog electronics to coherently suppress additive optical frequency comb noise. This relaxes the stabilization requirements and allows for the extraction of multiple independent microwave outputs from a single comb, while at the same time, permitting low-noise microwave generation from combs with higher noise profiles. Using this method we transferred the phase stability of two high-Finesse optical sources at 1157 nm and 1070 nm to two independent 10 GHz signals using a single frequency comb. We demonstrated absolute phase noise below -106 dBc/Hz at 1-Hz from carrier with corresponding 1 second fractional frequency instability below $2\times10^{-15}$. Finally, the latter phase noise levels were attainable for comb linewidths broadened up to 2 MHz, demonstrating the potential for out-of lab use with low SWaP lasers.
△ Less
Submitted 1 October, 2021;
originally announced October 2021.
-
Optical coherence between atomic species at the second scale: improved clock comparisons via differential spectroscopy
Authors:
May E. Kim,
William F. McGrew,
Nicholas V. Nardelli,
Ethan R. Clements,
Youssef S. Hassan,
Xiaogang Zhang,
Jose L. Valencia,
Holly Leopardi,
David B. Hume,
Tara M. Fortier,
Andrw D. Ludlow,
David R. Leibrandt
Abstract:
Comparisons of high-accuracy optical atomic clocks \cite{Ludlow2015} are essential for precision tests of fundamental physics \cite{Safronova2018}, relativistic geodesy \cite{McGrew2018, Grotti2018, Delva2019}, and the anticipated redefinition of the SI second \cite{Riehle2018}. The scientific reach of these applications is restricted by the statistical precision of interspecies comparison measure…
▽ More
Comparisons of high-accuracy optical atomic clocks \cite{Ludlow2015} are essential for precision tests of fundamental physics \cite{Safronova2018}, relativistic geodesy \cite{McGrew2018, Grotti2018, Delva2019}, and the anticipated redefinition of the SI second \cite{Riehle2018}. The scientific reach of these applications is restricted by the statistical precision of interspecies comparison measurements. The instability of individual clocks is limited by the finite coherence time of the optical local oscillator (OLO), which bounds the maximum atomic interrogation time. In this letter, we experimentally demonstrate differential spectroscopy \cite{Hume2016}, a comparison protocol that enables interrogating beyond the OLO coherence time. By phase-coherently linking a zero-dead-time (ZDT) \cite{Schioppo2017} Yb optical lattice clock with an Al$^+$ single-ion clock via an optical frequency comb and performing synchronised Ramsey spectroscopy, we show an improvement in comparison instability relative to our previous result \cite{network2020frequency} of nearly an order of magnitude. To our knowledge, this result represents the most stable interspecies clock comparison to date.
△ Less
Submitted 24 November, 2021; v1 submitted 20 September, 2021;
originally announced September 2021.
-
Optical Atomic Clock Comparison through Turbulent Air
Authors:
Martha I. Bodine,
Jean-Daniel Deschênes,
Isaac H. Khader,
William C. Swann,
Holly Leopardi,
Kyle Beloy,
Tobias Bothwell,
Samuel M. Brewer,
Sarah L. Bromley,
Jwo-Sy Chen,
Scott A. Diddams,
Robert J. Fasano,
Tara M. Fortier,
Youssef S. Hassan,
David B. Hume,
Dhruv Kedar,
Colin J. Kennedy,
Amanda Koepke,
David R. Leibrandt,
Andrew D. Ludlow,
William F. McGrew,
William R. Milner,
Daniele Nicolodi,
Eric Oelker,
Thomas E. Parker
, et al. (10 additional authors not shown)
Abstract:
We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the fr…
▽ More
We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the free-space link, ratio measurements obtained from the two links, averaged over 30.5 hours across six days, agree to $6\times10^{-19}$, showing that O-TWTFT can support free-space atomic clock comparisons below the $10^{-18}$ level.
△ Less
Submitted 11 September, 2020; v1 submitted 1 June, 2020;
originally announced June 2020.
-
Frequency Ratio Measurements with 18-digit Accuracy Using a Network of Optical Clocks
Authors:
Boulder Atomic Clock Optical Network,
Collaboration,
:,
Kyle Beloy,
Martha I. Bodine,
Tobias Bothwell,
Samuel M. Brewer,
Sarah L. Bromley,
Jwo-Sy Chen,
Jean-Daniel Deschênes,
Scott A. Diddams,
Robert J. Fasano,
Tara M. Fortier,
Youssef S. Hassan,
David B. Hume,
Dhruv Kedar,
Colin J. Kennedy,
Isaac Khader,
Amanda Koepke,
David R. Leibrandt,
Holly Leopardi,
Andrew D. Ludlow,
William F. McGrew,
William R. Milner,
Nathan R. Newbury
, et al. (13 additional authors not shown)
Abstract:
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al…
▽ More
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al$^+$, $^{171}$Yb and $^{87}$Sr optical clocks in Boulder, Colorado, measured across an optical network spanned by both fiber and free-space links. These ratios have been evaluated with measurement uncertainties between $6\times10^{-18}$ and $8\times10^{-18}$, making them the most accurate reported measurements of frequency ratios to date. This represents a critical step towards redefinition of the SI second and future applications such as relativistic geodesy and tests of fundamental physics.
△ Less
Submitted 29 May, 2020;
originally announced May 2020.
-
Coherent Optical Clock Down-Conversion for Microwave Frequencies with 10-18 Instability
Authors:
Takuma Nakamura,
Josue Davila-Rodriguez,
Holly Leopardi,
Jeff A. Sherman,
Tara M. Fortier,
Xiaojun Xie,
Joe C. Campbell,
William F. McGrew,
Xiaogang Zhang,
Youssef S. Hassan,
Daniele Nicolodi,
Kyle Beloy,
Andrew D. Ludlow,
Scott A. Diddams,
Franklyn Quinlan
Abstract:
Optical atomic clocks are poised to redefine the SI second, thanks to stability and accuracy more than one hundred times better than the current microwave atomic clock standard. However, the best optical clocks have not seen their performance transferred to the electronic domain, where radar, navigation, communications, and fundamental research rely on less stable microwave sources. By comparing t…
▽ More
Optical atomic clocks are poised to redefine the SI second, thanks to stability and accuracy more than one hundred times better than the current microwave atomic clock standard. However, the best optical clocks have not seen their performance transferred to the electronic domain, where radar, navigation, communications, and fundamental research rely on less stable microwave sources. By comparing two independent optical-to-electronic signal generators, we demonstrate a 10 GHz microwave signal with phase that exactly tracks that of the optical clock phase from which it is derived, yielding an absolute fractional frequency instability of 1*10-18 in the electronic domain. Such faithful reproduction of the optical clock phase expands the opportunities for optical clocks both technologically and scientifically for time-dissemination, navigation, and long-baseline interferometric imaging.
△ Less
Submitted 9 March, 2020; v1 submitted 5 March, 2020;
originally announced March 2020.
-
Ramsey-Bordé matter-wave interferometry for laser frequency stabilization at $10^{-16}$ frequency instability and below
Authors:
Judith Olson,
Richard W. Fox,
Tara M. Fortier,
Todd F. Sheerin,
Roger C. Brown,
Holly Leopardi,
Richard E. Stoner,
Chris W. Oates,
Andrew D. Ludlow
Abstract:
We demonstrate Ramsey-Bordé (RB) atom interferometry for high performance laser stabilization with fractional frequency instability $<2 \times 10^{-16}$ for timescales between 10 and 1000s. The RB spectroscopy laser interrogates two counterpropagating $^{40}$Ca beams on the $^1$S$_0$ -- $^3$P$_1$ transition at 657 nm, yielding 1.6 kHz linewidth interference fringes. Fluorescence detection of the e…
▽ More
We demonstrate Ramsey-Bordé (RB) atom interferometry for high performance laser stabilization with fractional frequency instability $<2 \times 10^{-16}$ for timescales between 10 and 1000s. The RB spectroscopy laser interrogates two counterpropagating $^{40}$Ca beams on the $^1$S$_0$ -- $^3$P$_1$ transition at 657 nm, yielding 1.6 kHz linewidth interference fringes. Fluorescence detection of the excited state population is performed on the (4s4p) $^3$P$_1$ -- (4p$^2$) $^3$P$_0$ transition at 431 nm. Minimal thermal shielding and no vibration isolation are used. These stability results surpass performance from other thermal atomic or molecular systems by one to two orders of magnitude, and further improvements look feasible.
△ Less
Submitted 15 July, 2019;
originally announced July 2019.
-
Demonstration of a time scale based on a stable optical carrier
Authors:
William R. Milner,
John M. Robinson,
Colin J. Kennedy,
Tobias Bothwell,
Dhruv Kedar,
Dan G. Matei,
Thomas Legero,
Uwe Sterr,
Fritz Riehle,
Holly Leopardi,
Tara M. Fortier,
Jeffrey A. Sherman,
Judah Levine,
Jian Yao,
Jun Ye,
Eric Oelker
Abstract:
We demonstrate a time scale based on a phase stable optical carrier that accumulates an estimated time error of $48\pm94$ ps over 34 days of operation. This all-optical time scale is formed with a cryogenic silicon cavity exhibiting improved long-term stability and an accurate $^{87}$Sr lattice clock. We show that this new time scale architecture outperforms existing microwave time scales, even wh…
▽ More
We demonstrate a time scale based on a phase stable optical carrier that accumulates an estimated time error of $48\pm94$ ps over 34 days of operation. This all-optical time scale is formed with a cryogenic silicon cavity exhibiting improved long-term stability and an accurate $^{87}$Sr lattice clock. We show that this new time scale architecture outperforms existing microwave time scales, even when they are steered to optical frequency standards. Our analysis indicates that this time scale is capable of reaching a stability below $1\times10^{-17}$ after a few months of averaging, making timekee** at the $10^{-18}$ level a realistic prospect.
△ Less
Submitted 6 July, 2019;
originally announced July 2019.
-
Measurements of $^{27}$Al$^{+}$ and $^{25}$Mg$^{+}$ magnetic constants for improved ion clock accuracy
Authors:
S. M. Brewer,
J. -S. Chen,
K. Beloy,
A. M. Hankin,
E. R. Clements,
C. W. Chou,
W. F. McGrew,
X. Zhang,
R. J. Fasano,
D. Nicolodi,
H. Leopardi,
T. M. Fortier,
S. A. Diddams,
A. D. Ludlow,
D. J. Wineland,
D. R. Leibrandt,
D. B. Hume
Abstract:
We have measured the quadratic Zeeman coefficient for the ${^{1}S_{0} \leftrightarrow {^{3}P_{0}}}$ optical clock transition in $^{27}$Al$^{+}$, $C_{2}=-71.944(24)$~MHz/T$^{2}$, and the unperturbed hyperfine splitting of the $^{25}$Mg$^{+}$ $^{2}S_{1/2}$ ground electronic state, $ΔW / h = 1~788~762~752.85(13)$~Hz, with improved uncertainties. Both constants are relevant to the evaluation of the…
▽ More
We have measured the quadratic Zeeman coefficient for the ${^{1}S_{0} \leftrightarrow {^{3}P_{0}}}$ optical clock transition in $^{27}$Al$^{+}$, $C_{2}=-71.944(24)$~MHz/T$^{2}$, and the unperturbed hyperfine splitting of the $^{25}$Mg$^{+}$ $^{2}S_{1/2}$ ground electronic state, $ΔW / h = 1~788~762~752.85(13)$~Hz, with improved uncertainties. Both constants are relevant to the evaluation of the $^{27}$Al$^{+}$ quantum-logic clock systematic uncertainty. The measurement of $C_{2}$ is in agreement with a previous measurement and a new calculation at the $1~σ$ level. The measurement of $ΔW$ is in good agreement with a recent measurement and differs from a previously published result by approximately $2σ$. With the improved value for $ΔW$, we deduce an improved value for the nuclear-to-electronic g-factor ratio $g_{I}/g_{J} = 9.299 ~308 ~313(60) \times 10^{-5}$ and the nuclear g-factor for the $^{25}$Mg nucleus $g_{I} = 1.861 ~957 ~82(28) \times 10^{-4}$. Using the values of $C_{2}$ and $ΔW$ presented here, we derive a quadratic Zeeman shift of the $^{27}$Al$^{+}$ quantum-logic clock of $Δν/ ν= -(9241.8 \pm 3.7) \times 10^{-19}$, for a bias magnetic field of $B \approx 0.12$~mT.
△ Less
Submitted 22 May, 2019; v1 submitted 11 March, 2019;
originally announced March 2019.
-
Towards Adoption of an Optical Second: Verifying Optical Clocks at the SI Limit
Authors:
W. F. McGrew,
X. Zhang,
H. Leopardi,
R. J. Fasano,
D. Nicolodi,
K. Beloy,
J. Yao,
J. A. Sherman,
S. A. Schäffer,
J. Savory,
R. C. Brown,
S. Römisch,
C. W. Oates,
T. E. Parker,
T. M. Fortier,
A. D. Ludlow
Abstract:
The pursuit of ever more precise measures of time and frequency is likely to lead to the eventual redefinition of the second in terms of an optical atomic transition. To ensure continuity with the current definition, based on a microwave transition between hyperfine levels in ground-state $^{133}$Cs, it is necessary to measure the absolute frequency of candidate standards, which is done by compari…
▽ More
The pursuit of ever more precise measures of time and frequency is likely to lead to the eventual redefinition of the second in terms of an optical atomic transition. To ensure continuity with the current definition, based on a microwave transition between hyperfine levels in ground-state $^{133}$Cs, it is necessary to measure the absolute frequency of candidate standards, which is done by comparing against a primary cesium reference. A key verification of this process can be achieved by performing a loop closure$-$comparing frequency ratios derived from absolute frequency measurements against ratios determined from direct optical comparisons. We measure the $^1$S$_0\!\rightarrow^3$P$_0$ transition of $^{171}$Yb by comparing the clock frequency to an international frequency standard with the aid of a maser ensemble serving as a flywheel oscillator. Our measurements consist of 79 separate runs spanning eight months, and we determine the absolute frequency to be 518 295 836 590 863.71(11) Hz, the uncertainty of which is equivalent to a fractional frequency of $2.1\times10^{-16}$. This absolute frequency measurement, the most accurate reported for any transition, allows us to close the Cs-Yb-Sr-Cs frequency measurement loop at an uncertainty of $<$3$\times10^{-16}$, limited by the current realization of the SI second. We use these measurements to tighten the constraints on variation of the electron-to-proton mass ratio, $μ=m_e/m_p$. Incorporating our measurements with the entire record of Yb and Sr absolute frequency measurements, we infer a coupling coefficient to gravitational potential of $k_\mathrmμ=(-1.9\pm 9.4)\times10^{-7}$ and a drift with respect to time of $\frac{\dotμ}μ=(5.3 \pm 6.5)\times10^{-17}/$yr.
△ Less
Submitted 14 November, 2018;
originally announced November 2018.
-
Optimizing the linearity in high-speed photodiodes
Authors:
J. Davila-Rodriguez,
X. Xie,
J. Zang,
C. J. Long,
T. M. Fortier,
H. Leopardi,
T. Nakamura,
J. C. Campbell,
S. A. Diddams,
F. Quinlan
Abstract:
Analog photonic links require high-fidelity, high-speed optical-to-electrical conversion for applications such as radio-over-fiber, synchronization at kilometer-scale facilities, and low-noise electronic signal generation. Photodetector nonlinearity is a particularly vexing problem, causing signal distortion and excess noise, especially in systems utilizing ultrashort optical pulses. Here we show…
▽ More
Analog photonic links require high-fidelity, high-speed optical-to-electrical conversion for applications such as radio-over-fiber, synchronization at kilometer-scale facilities, and low-noise electronic signal generation. Photodetector nonlinearity is a particularly vexing problem, causing signal distortion and excess noise, especially in systems utilizing ultrashort optical pulses. Here we show that photodetectors designed for high power handling and high linearity can perform optical-to-electrical conversion of ultrashort optical pulses with unprecedented linearity over a large photocurrent range. We also show that the broadband, complex impedance of the circuit following the photodiode modifies the linearity significantly. By externally manipulating the circuit impedance, we extend the detector's linear range to higher photocurrents, with over 50 dB rejection of amplitude-to-phase conversion for photocurrents up to 40 mA. This represents a 1000-fold improvement over state-of-the-art photodiodes and significantly extends the attainable microwave power by a factor of four. As such, we eliminate the long-standing requirement in ultrashort pulse detection of precise tuning of the photodiode's operating parameters (average photocurrent, bias voltage or temperature) to coincide with a nonlinearity minimum. These results should also apply more generally to reduce nonlinear distortion in a range of other microwave photonics applications.
△ Less
Submitted 13 August, 2018;
originally announced August 2018.
-
Hyperpolarizability and operational magic wavelength in an optical lattice clock
Authors:
R. C. Brown,
N. B. Phillips,
K. Beloy,
W. F. McGrew,
M. Schioppo,
R. J. Fasano,
G. Milani,
X. Zhang,
N. Hinkley,
H. Leopardi,
T. H. Yoon,
D. Nicolodi,
T. M. Fortier,
A. D. Ludlow
Abstract:
Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentall…
▽ More
Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an $^{171}$Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the $10^{-18}$ level and beyond.
△ Less
Submitted 24 October, 2017; v1 submitted 29 August, 2017;
originally announced August 2017.
-
A compact, thermal noise limited reference cavity for ultra-low noise microwave generation
Authors:
J. Davila-Rodriguez,
F. N. Baynes,
A. D. Ludlow,
T. M. Fortier,
H. Leopardi,
S. A. Diddams,
F. Quinlan
Abstract:
We demonstrate an easy to manufacture, 25 mm long ultra-stable optical reference cavity for transportable photonic microwave generation systems. Employing a rigid holding geometry that is first-order insensitive to the squeezing force and a cavity geometry that improves the thermal noise limit at room temperature, we observe a laser phase noise that is nearly thermal noise limited for three freque…
▽ More
We demonstrate an easy to manufacture, 25 mm long ultra-stable optical reference cavity for transportable photonic microwave generation systems. Employing a rigid holding geometry that is first-order insensitive to the squeezing force and a cavity geometry that improves the thermal noise limit at room temperature, we observe a laser phase noise that is nearly thermal noise limited for three frequency decades (1 Hz to 1 kHz offset) and supports 10 GHz generation with phase noise near -100 dBc/Hz at 1 Hz offset and <-173 dBc/Hz for all offsets >600 Hz. The fractional frequency stability reaches $2\times10^{-15}$ at 0.1 s of averaging.
△ Less
Submitted 6 January, 2017;
originally announced January 2017.
-
Microresonator Brillouin Laser Stabilization Using a Microfabricated Rubidium Cell
Authors:
William Loh,
Matthew T. Hummon,
Holly F. Leopardi,
Tara M. Fortier,
Frank Quinlan,
John Kitching,
Scott B. Papp,
Scott A. Diddams
Abstract:
We frequency stabilize the output of a miniature stimulated Brillouin scattering (SBS) laser to rubidium atoms in a microfabricated cell to realize a laser system with frequency stability at the $10^{-11}$ level over seven decades in averaging time. In addition, our system has the advantages of robustness, low cost and the potential for integration that would lead to still further miniaturization.…
▽ More
We frequency stabilize the output of a miniature stimulated Brillouin scattering (SBS) laser to rubidium atoms in a microfabricated cell to realize a laser system with frequency stability at the $10^{-11}$ level over seven decades in averaging time. In addition, our system has the advantages of robustness, low cost and the potential for integration that would lead to still further miniaturization. The SBS laser operating at 1560 nm exhibits a spectral linewidth of 820 Hz, but its frequency drifts over a few MHz on the 1 hour timescale. By locking the second harmonic of the SBS laser to the Rb reference, we reduce this drift by a factor of $10^3$ to the level of a few kHz over the course of an hour. For our combined SBS and Rb laser system, we measure a frequency noise of $4\times10^4$ $Hz^2/Hz$ at 10 Hz offset frequency which rapidly rolls off to a level of 0.2 $Hz^2/Hz$ at 100 kHz offset. The corresponding Allan deviation is $\leq2\times10^{-11}$ for averaging times spanning $10^{-4}$ to $10^3$ s. By optically dividing the signal of the laser down to microwave frequencies, we generate an RF signal at 2 GHz with phase noise at the level of -76 dBc/Hz and -140 dBc/Hz at offset frequencies of 10 Hz and 10 kHz, respectively.
△ Less
Submitted 24 April, 2016;
originally announced April 2016.
-
Digital-photonic synthesis of ultra-low noise tunable signals from RF to 100 GHz
Authors:
T. M. Fortier,
A. Rolland,
F. Quinlan,
F. N. Baynes,
A. J. Metcalf,
A. Hati,
A. Ludlow,
N. Hinkley,
M. Shimizu,
T. Ishibashi,
J. C. Campbell,
S. A. Diddams
Abstract:
The demand for higher data rates and better synchronization in communication and navigation systems necessitates the development of new wideband and tunable sources with noise performance exceeding that provided by traditional oscillators and synthesizers. Precision synthesis is paramount for providing frequency references and timing in a broad range of applications including next-generation telec…
▽ More
The demand for higher data rates and better synchronization in communication and navigation systems necessitates the development of new wideband and tunable sources with noise performance exceeding that provided by traditional oscillators and synthesizers. Precision synthesis is paramount for providing frequency references and timing in a broad range of applications including next-generation telecommunications, high precision measurement, and radar and sensing. Here we describe a digital-photonic synthesizer (DPS) based on optical frequency division that enables the generation of widely tunable signals from near DC to 100 GHz with a fractional frequency instability of 1 part in 10^15. The spectral purity of the DPS derived signals represents an improvement in close-to-carrier noise performance over the current state-of-the-art of nearly 7 orders of magnitude in the W-band (100 GHz), and up to 5 orders of magnitude in the X-band (10 GHz).
△ Less
Submitted 10 June, 2015;
originally announced June 2015.
-
Optical amplification and pulse interleaving for low noise photonic microwave generation
Authors:
Franklyn Quinlan,
Fred N. Baynes,
Tara M. Fortier,
Qiugui Zhou,
Allen Cross,
Joe C. Campbell,
Scott A. Diddams
Abstract:
We investigate the impact of pulse interleaving and optical amplification on the spectral purity of microwave signals generated by photodetecting the pulsed output of an Er:fiber-based optical frequency comb. It is shown that the microwave phase noise floor can be extremely sensitive to delay length errors in the interleaver, and the contribution of the quantum noise from optical amplification to…
▽ More
We investigate the impact of pulse interleaving and optical amplification on the spectral purity of microwave signals generated by photodetecting the pulsed output of an Er:fiber-based optical frequency comb. It is shown that the microwave phase noise floor can be extremely sensitive to delay length errors in the interleaver, and the contribution of the quantum noise from optical amplification to the phase noise can be reduced ~10 dB for short pulse detection. We exploit optical amplification, in conjunction with high power handling modified uni-traveling carrier photodetectors, to generate a phase noise floor on a 10 GHz carrier of -175 dBc/Hz, the lowest ever demonstrated in the photodetection of a mode-locked fiber laser. At all offset frequencies, the photodetected 10 GHz phase noise performance is comparable to or better than the lowest phase noise results yet demonstrated with stabilized Ti:sapphire frequency combs.
△ Less
Submitted 6 December, 2013;
originally announced December 2013.
-
Absolute and relative stability of an optical frequency reference based on spectral hole burning in Eu$^{3+}$:Y$_2$SiO$_5$
Authors:
David R. Leibrandt,
Michael J. Thorpe,
Chin-Wen Chou,
Tara M. Fortier,
Scott A. Diddams,
Till Rosenband
Abstract:
We present and analyze four frequency measurements designed to characterize the performance of an optical frequency reference based on spectral hole burning in \EuYSO. The first frequency comparison, between a single unperturbed spectral hole and a hydrogen maser, demonstrates a fractional frequency drift rate of $5 \times 10^{-18}$ s$^{-1}$. Optical-frequency comparisons between a pattern of spec…
▽ More
We present and analyze four frequency measurements designed to characterize the performance of an optical frequency reference based on spectral hole burning in \EuYSO. The first frequency comparison, between a single unperturbed spectral hole and a hydrogen maser, demonstrates a fractional frequency drift rate of $5 \times 10^{-18}$ s$^{-1}$. Optical-frequency comparisons between a pattern of spectral holes, a Fabry-Pérot cavity, and an Al$^+$ optical atomic clock show a short-term fractional frequency stability of $1 \times10^{-15} τ^{-1/2}$ that averages down to $2.5^{+1.1}_{-0.5} \times 10^{-16}$ at $τ= 540~s$ (with linear frequency drift removed). Finally, spectral hole patterns in two different \EuYSO crystals located in the same cryogenic vessel are compared, yielding a short-term stability of $7 \times10^{-16} τ^{-1/2}$ that averages down to $5.5^{+1.8}_{-0.9} \times 10^{-17}$ at $τ= 204$~s (with quadratic frequency drift removed).
△ Less
Submitted 31 October, 2013; v1 submitted 19 July, 2013;
originally announced July 2013.
-
Analysis of shot noise in the detection of ultrashort optical pulse trains
Authors:
Franklyn Quinlan,
Tara M. Fortier,
Haifeng Jiang,
Scott A. Diddams
Abstract:
We present a frequency domain model of shot noise in the photodetection of ultrashort optical pulse trains using a time-varying analysis. Shot noise-limited photocurrent power spectral densities, signal-to-noise expressions, and shot noise spectral correlations are derived that explicitly include the finite response of the photodetector. It is shown that the strength of the spectral correlations i…
▽ More
We present a frequency domain model of shot noise in the photodetection of ultrashort optical pulse trains using a time-varying analysis. Shot noise-limited photocurrent power spectral densities, signal-to-noise expressions, and shot noise spectral correlations are derived that explicitly include the finite response of the photodetector. It is shown that the strength of the spectral correlations in the shot noise depends on the optical pulse width, and that these correlations can create orders-of-magnitude imbalance between the shot noise-limited amplitude and phase noise of photonically generated microwave carriers. It is also shown that only by accounting for spectral correlations can shot noise be equated with the fundamental quantum limit in the detection of optical pulse-to-pulse timing jitter.
△ Less
Submitted 25 February, 2013;
originally announced February 2013.
-
Photonic microwave generation with high-power photodiodes
Authors:
Tara M. Fortier,
Franklyn Quinlan,
Archita Hati,
Craig Nelson,
Jennifer A. Taylor,
Yang Fu,
Joe Campbell,
Scott A. Diddams
Abstract:
We utilize and characterize high-power, high-linearity modified uni-traveling carrier (MUTC) photodiodes for low-phase-noise photonic microwave generation based on optical frequency division. When illuminated with picosecond pulses from a repetition-rate-multiplied gigahertz Ti:sapphire modelocked laser, the photodiodes can achieve 10 GHz signal power of +14 dBm. Using these diodes, a 10 GHz micro…
▽ More
We utilize and characterize high-power, high-linearity modified uni-traveling carrier (MUTC) photodiodes for low-phase-noise photonic microwave generation based on optical frequency division. When illuminated with picosecond pulses from a repetition-rate-multiplied gigahertz Ti:sapphire modelocked laser, the photodiodes can achieve 10 GHz signal power of +14 dBm. Using these diodes, a 10 GHz microwave tone is generated with less than 500 attoseconds absolute integrated timing jitter (1 Hz-10 MHz) and a phase noise floor of -177 dBc/Hz. We also characterize the electrical response, amplitude-to-phase conversion, saturation and residual noise of the MUTC photodiodes.
△ Less
Submitted 24 February, 2013;
originally announced February 2013.
-
Sub-femtosecond absolute timing precision with a 10 GHz hybrid photonic-microwave oscillator
Authors:
T. M. Fortier,
C. W. Nelson,
A. Hati,
F. Quinlan,
J. Taylor,
H. Jiang,
C. W. Chou,
T. Rosenband,
N. Lemke,
A. Ludlow,
D. Howe,
C. W. Oates,
S. A. Diddams
Abstract:
We present an optical-electronic approach to generating microwave signals with high spectral purity. By circumventing shot noise and operating near fundamental thermal limits, we demonstrate 10 GHz signals with an absolute timing jitter for a single hybrid oscillator of 420 attoseconds (1Hz - 5 GHz).
We present an optical-electronic approach to generating microwave signals with high spectral purity. By circumventing shot noise and operating near fundamental thermal limits, we demonstrate 10 GHz signals with an absolute timing jitter for a single hybrid oscillator of 420 attoseconds (1Hz - 5 GHz).
△ Less
Submitted 5 May, 2012;
originally announced May 2012.
-
Frequency-stabilization to 6x10^-16 via spectral-hole burning
Authors:
Michael J. Thorpe,
Lars Rippe,
Tara M. Fortier,
Matthew S. Kirchner,
Till Rosenband
Abstract:
We demonstrate two-stage laser stabilization based on a combination of Fabry- Perot and spectral-hole burning techniques. The laser is first pre-stabilized by the Fabry-Perot cavity to a fractional-frequency stability of sigma_y(tau) < 10^-13. A pattern of spectral holes written in the absorption spectrum of Eu3+:Y2SiO5 serves to further stabilize the laser to sigma_y(tau) = 6x10^-16 for 2 s < tau…
▽ More
We demonstrate two-stage laser stabilization based on a combination of Fabry- Perot and spectral-hole burning techniques. The laser is first pre-stabilized by the Fabry-Perot cavity to a fractional-frequency stability of sigma_y(tau) < 10^-13. A pattern of spectral holes written in the absorption spectrum of Eu3+:Y2SiO5 serves to further stabilize the laser to sigma_y(tau) = 6x10^-16 for 2 s < tau < 8 s. Measurements characterizing the frequency sensitivity of Eu3+:Y2SiO5 spectral holes to environmental perturbations suggest that they can be more frequency stable than Fabry-Perot cavities.
△ Less
Submitted 2 June, 2011;
originally announced June 2011.
-
Ultralow phase noise microwave generation with an Er:fiber-based optical frequency divider
Authors:
F. Quinlan,
T. M. Fortier,
M. S. Kirchner,
J. A. Taylor,
M. J. Thorpe,
N. Lemke,
A. D. Ludlow,
Y. Jiang,
C. W. Oates,
S. A. Diddams
Abstract:
We present an optical frequency divider based on a 200 MHz repetition rate Er:fiber mode-locked laser that, when locked to a stable optical frequency reference, generates microwave signals with absolute phase noise that is equal to or better than cryogenic microwave oscillators. At 1 Hz offset from a 10 GHz carrier, the phase noise is below -100 dBc/Hz, limited by the optical reference. For offset…
▽ More
We present an optical frequency divider based on a 200 MHz repetition rate Er:fiber mode-locked laser that, when locked to a stable optical frequency reference, generates microwave signals with absolute phase noise that is equal to or better than cryogenic microwave oscillators. At 1 Hz offset from a 10 GHz carrier, the phase noise is below -100 dBc/Hz, limited by the optical reference. For offset frequencies > 10 kHz, the phase noise is shot noise limited at -145 dBc/Hz. An analysis of the contribution of the residual noise from the Er:fiber optical frequency divider is also presented.
△ Less
Submitted 7 May, 2011;
originally announced May 2011.
-
Generation of Ultrastable Microwaves via Optical Frequency Division
Authors:
T. M. Fortier,
M. S. Kirchner,
F. Quinlan,
J. Taylor,
J. C. Bergquist,
T. Rosenband,
N. Lemke,
A. Ludlow,
Y. Jiang,
C. W. Oates,
S. A. Diddams
Abstract:
There has been increased interest in the use and manipulation of optical fields to address challenging problems that have traditionally been approached with microwave electronics. Some examples that benefit from the low transmission loss, agile modulation and large bandwidths accessible with coherent optical systems include signal distribution, arbitrary waveform generation, and novel imaging. We…
▽ More
There has been increased interest in the use and manipulation of optical fields to address challenging problems that have traditionally been approached with microwave electronics. Some examples that benefit from the low transmission loss, agile modulation and large bandwidths accessible with coherent optical systems include signal distribution, arbitrary waveform generation, and novel imaging. We extend these advantages to demonstrate a microwave generator based on a high-Q optical resonator and a frequency comb functioning as an optical-to-microwave divider. This provides a 10 GHz electrical signal with fractional frequency instability <8e-16 at 1 s, a value comparable to that produced by the best microwave oscillators, but without the need for cryogenic temperatures. Such a low-noise source can benefit radar systems, improve the bandwidth and resolution of communications and digital sampling systems, and be valuable for large baseline interferometry, precision spectroscopy and the realization of atomic time.
△ Less
Submitted 28 April, 2011; v1 submitted 19 January, 2011;
originally announced January 2011.
-
Femtosecond frequency comb measurement of absolute frequencies and hyperfine coupling constants in cesium vapor
Authors:
Jason E. Stalnaker,
Vela Mbele,
Vladislav Gerginov,
Tara M. Fortier,
Scott A. Diddams,
Leo Hollberg,
Carol E. Tanner
Abstract:
We report measurements of absolute transition frequencies and hyperfine coupling constants for the 8S_{1/2}, 9S_{1/2}, 7D_{3/2}, and 7D_{5/2} states in ^{133}Cs vapor. The stepwise excitation through either the 6P_{1/2} or 6P_{3/2} intermediate state is performed directly with broadband laser light from a stabilized femtosecond laser optical-frequency comb. The laser beam is split, counter-propa…
▽ More
We report measurements of absolute transition frequencies and hyperfine coupling constants for the 8S_{1/2}, 9S_{1/2}, 7D_{3/2}, and 7D_{5/2} states in ^{133}Cs vapor. The stepwise excitation through either the 6P_{1/2} or 6P_{3/2} intermediate state is performed directly with broadband laser light from a stabilized femtosecond laser optical-frequency comb. The laser beam is split, counter-propagated and focused into a room-temperature Cs vapor cell. The repetition rate of the frequency comb is scanned and we detect the fluorescence on the 7P_{1/2,3/2} -> 6S_{1/2} branches of the decay of the excited states. The excitations to the different states are isolated by the introduction of narrow-bandwidth interference filters in the laser beam paths. Using a nonlinear least-squares method we find measurements of transition frequencies and hyperfine coupling constants that are in agreement with other recent measurements for the 8S state and provide improvement by two orders of magnitude over previously published results for the 9S and 7D states.
△ Less
Submitted 18 January, 2010;
originally announced January 2010.
-
Spin-1/2 Optical Lattice Clock
Authors:
N. D. Lemke,
A. D. Ludlow,
Z. W. Barber,
T. M. Fortier,
S. A. Diddams,
Y. Jiang,
S. R. Jefferts,
T. P. Heavner,
T. E. Parker,
C. W. Oates
Abstract:
We experimentally investigate an optical clock based on $^{171}$Yb ($I=1/2$) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of $3.4 \times 10^{-16}$, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock tran…
▽ More
We experimentally investigate an optical clock based on $^{171}$Yb ($I=1/2$) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of $3.4 \times 10^{-16}$, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock transition frequency relative to the NIST-F1 Cs fountain clock and find the frequency to be 518 295 836 590 865.2(0.7) Hz.
△ Less
Submitted 24 July, 2009; v1 submitted 5 June, 2009;
originally announced June 2009.
-
Frequency evaluation of the doubly forbidden $^1S_0\to ^3P_0$ transition in bosonic $^{174}$Yb
Authors:
N. Poli,
Z. W. Barber,
N. D. Lemke,
C. W. Oates,
L. S. Ma,
J. E. Stalnaker,
T. M. Fortier,
S. A. Diddams,
L. Hollberg,
J. C. Bergquist,
A. Brusch,
S. Jefferts,
T. Heavner,
T. Parker
Abstract:
We report an uncertainty evaluation of an optical lattice clock based on the $^1S_0\leftrightarrow^3P_0$ transition in the bosonic isotope $^{174}$Yb by use of magnetically induced spectroscopy. The absolute frequency of the $^1S_0\leftrightarrow^3P_0$ transition has been determined through comparisons with optical and microwave standards at NIST. The weighted mean of the evaluations is $ν$(…
▽ More
We report an uncertainty evaluation of an optical lattice clock based on the $^1S_0\leftrightarrow^3P_0$ transition in the bosonic isotope $^{174}$Yb by use of magnetically induced spectroscopy. The absolute frequency of the $^1S_0\leftrightarrow^3P_0$ transition has been determined through comparisons with optical and microwave standards at NIST. The weighted mean of the evaluations is $ν$($^{174}$Yb)=518 294 025 309 217.8(0.9) Hz. The uncertainty due to systematic effects has been reduced to less than 0.8 Hz, which represents $1.5\times10^{-15}$ in fractional frequency.
△ Less
Submitted 31 March, 2008;
originally announced March 2008.
-
Optical Lattice Induced Light Shifts in an Yb Atomic Clock
Authors:
Z. W. Barber,
J. E. Stalnaker,
N. D. Lemke,
N. Poli,
C. W. Oates,
T. M. Fortier,
S. A. Diddams,
L. Hollberg,
C. W. Hoyt
Abstract:
We present an experimental study of the lattice induced light shifts on the 1S_0-3P_0 optical clock transition (v_clock~518 THz) in neutral ytterbium. The ``magic'' frequency, v_magic, for the 174Yb isotope was determined to be 394 799 475(35)MHz, which leads to a first order light shift uncertainty of 0.38 Hz on the 518 THz clock transition. Also investigated were the hyperpolarizability shifts…
▽ More
We present an experimental study of the lattice induced light shifts on the 1S_0-3P_0 optical clock transition (v_clock~518 THz) in neutral ytterbium. The ``magic'' frequency, v_magic, for the 174Yb isotope was determined to be 394 799 475(35)MHz, which leads to a first order light shift uncertainty of 0.38 Hz on the 518 THz clock transition. Also investigated were the hyperpolarizability shifts due to the nearby 6s6p 3P_0 - 6s8p 3P_0, 6s8p 3P_2, and 6s5f 3F_2 two-photon resonances at 759.708 nm, 754.23 nm, and 764.95 nm respectively. By tuning the lattice frequency over the two-photon resonances and measuring the corresponding clock transition shifts, the hyperpolarizability shift was estimated to be 170(33) mHz for a linear polarized, 50 uK deep, lattice at the magic wavelength. In addition, we have confirmed that a circularly polarized lattice eliminates the J=0 - J=0 two-photon resonance. These results indicate that the differential polarizability and hyperpolarizability frequency shift uncertainties in a Yb lattice clock could be held to well below 10^-17.
△ Less
Submitted 1 February, 2008;
originally announced February 2008.
-
Sr lattice clock at 1x10^{-16} fractional uncertainty by remote optical evaluation with a Ca clock
Authors:
A. D. Ludlow,
T. Zelevinsky,
G. K. Campbell,
S. Blatt,
M. M. Boyd,
M. H. G. de Miranda,
M. J. Martin,
J. W. Thomsen,
S. M. Foreman,
Jun Ye,
T. M. Fortier,
J. E. Stalnaker,
S. A. Diddams,
Y. Le Coq,
Z. W. Barber,
N. Poli,
N. D. Lemke,
K. M. Beck,
C. W. Oates
Abstract:
Optical atomic clocks promise timekee** at the highest precision and accuracy, owing to their high operating frequencies. Rigorous evaluations of these clocks require direct comparisons between them. We have realized a high-performance remote comparison of optical clocks over km-scale urban distances, a key step for development, dissemination, and application of these optical standards. Throug…
▽ More
Optical atomic clocks promise timekee** at the highest precision and accuracy, owing to their high operating frequencies. Rigorous evaluations of these clocks require direct comparisons between them. We have realized a high-performance remote comparison of optical clocks over km-scale urban distances, a key step for development, dissemination, and application of these optical standards. Through this remote comparison and a proper design of lattice-confined neutral atoms for clock operation, we evaluate the uncertainty of a strontium (Sr) optical lattice clock at the 1x10-16 fractional level, surpassing the best current evaluations of cesium (Cs) primary standards. We also report on the observation of density-dependent effects in the spin-polarized fermionic sample and discuss the current limiting effect of blackbody radiation-induced frequency shifts.
△ Less
Submitted 28 March, 2008; v1 submitted 28 January, 2008;
originally announced January 2008.
-
Observation of the 1S0 - 3P0 clock transition in 27Al+
Authors:
T. Rosenband,
P. O. Schmidt,
D. B. Hume,
W. M. Itano,
T. M. Fortier,
J. E. Stalnaker,
K. Kim,
S. A. Diddams,
J. C. J. Koelemeij,
J. C. Bergquist,
D. J. Wineland
Abstract:
We report for the first time, laser spectroscopy of the 1S0 - 3P0 clock transition in 27Al+. A single aluminum ion and a single beryllium ion are simultaneously confined in a linear Paul trap, coupled by their mutual Coulomb repulsion. This coupling allows the beryllium ion to sympathetically cool the aluminum ion, and also enables transfer of the aluminum's electronic state to the beryllium's h…
▽ More
We report for the first time, laser spectroscopy of the 1S0 - 3P0 clock transition in 27Al+. A single aluminum ion and a single beryllium ion are simultaneously confined in a linear Paul trap, coupled by their mutual Coulomb repulsion. This coupling allows the beryllium ion to sympathetically cool the aluminum ion, and also enables transfer of the aluminum's electronic state to the beryllium's hyperfine state, which can be measured with high fidelity. These techniques are applied to a measurement of the clock transition frequency, ν= 1 121 015 393 207 851(8) Hz. They are also used to measure the lifetime of the metastable clock state, τ= 20.6 +/- 1.4 s, the ground state 1S0 g-factor, g_S = -0.00079248(14), and the excited state 3P0 g-factor, g_P = -0.00197686(21), in units of the Bohr magneton.
△ Less
Submitted 8 April, 2007; v1 submitted 6 March, 2007;
originally announced March 2007.
-
Measurement of excited-state transitions in cold calcium atoms by direct femtosecond frequency-comb spectroscopy
Authors:
J. E. Stalnaker,
Y. Le Coq,
T. M. Fortier,
S. A. Diddams,
C. W. Oates,
L. Hollberg
Abstract:
We apply direct frequency-comb spectroscopy, in combination with precision cw spectroscopy, to measure the ${\rm 4s4p} ^3P_1 \to {\rm 4s5s} ^3S_1$ transition frequency in cold calcium atoms. A 657 nm ultrastable cw laser was used to excite atoms on the narrow ($γ\sim 400$ Hz) ${\rm 4s^2} ^1S_0 \to {\rm 4s4p} ^3P_1$ clock transition, and the direct output of the frequency comb was used to excite…
▽ More
We apply direct frequency-comb spectroscopy, in combination with precision cw spectroscopy, to measure the ${\rm 4s4p} ^3P_1 \to {\rm 4s5s} ^3S_1$ transition frequency in cold calcium atoms. A 657 nm ultrastable cw laser was used to excite atoms on the narrow ($γ\sim 400$ Hz) ${\rm 4s^2} ^1S_0 \to {\rm 4s4p} ^3P_1$ clock transition, and the direct output of the frequency comb was used to excite those atoms from the ${\rm 4s4p} ^3P_1$ state to the ${\rm 4s5s} ^3S_1$ state. The resonance of this second stage was detected by observing a decrease in population of the ground state as a result of atoms being optically pumped to the metastable ${\rm 4s4p} ^3P_{0,2}$ states. The ${\rm 4s4p} ^3P_1 \to {\rm 4s5s} ^3S_1$ transition frequency is measured to be $ν= 489 544 285 713(56)$ kHz; which is an improvement by almost four orders of magnitude over the previously measured value. In addition, we demonstrate spectroscopy on magnetically trapped atoms in the ${\rm 4s4p} ^3P_2$ state.
△ Less
Submitted 16 January, 2007;
originally announced January 2007.
-
Kilohertz-resolution spectroscopy of cold atoms with an optical frequency comb
Authors:
T. M. Fortier,
Y. Le Coq,
J. E. Stalnaker,
D. Ortega,
S. A. Diddams,
C. W. Oates,
L. Hollberg
Abstract:
We have performed sub-Doppler spectroscopy on the narrow intercombination line of cold calcium atoms using the amplified output of a femtosecond laser frequency comb. Injection locking of a 657-nm diode laser with a femtosecond comb allows for two regimes of amplification, one in which many lines of the comb are amplified, and one where a single line is predominantly amplified. The output of the…
▽ More
We have performed sub-Doppler spectroscopy on the narrow intercombination line of cold calcium atoms using the amplified output of a femtosecond laser frequency comb. Injection locking of a 657-nm diode laser with a femtosecond comb allows for two regimes of amplification, one in which many lines of the comb are amplified, and one where a single line is predominantly amplified. The output of the laser in both regimes was used to perform kilohertz-level spectroscopy. This experiment demonstrates the potential for high-resolution absolute-frequency spectroscopy over the entire spectrum of the frequency comb output using a single high-finesse optical reference cavity.
△ Less
Submitted 3 May, 2006;
originally announced May 2006.
-
Observation and absolute frequency measurements of the 1S0 - 3P0 optical clock transition in ytterbium
Authors:
C. W. Hoyt,
Z. W. Barber,
C. W. Oates,
T. M. Fortier,
S. A. Diddams,
L. Hollberg
Abstract:
We report the direct excitation of the highly forbidden (6s^2) 1S0 - (6s6p) 3P0 optical transition in two odd isotopes of ytterbium. As the excitation laser frequency is scanned, absorption is detected by monitoring the depletion from an atomic cloud at ~70 uK in a magneto-optical trap. The measured frequency in 171Yb (F=1/2) is 518,295,836,593.2 +/- 4.4 kHz. The measured frequency in 173Yb (F=5…
▽ More
We report the direct excitation of the highly forbidden (6s^2) 1S0 - (6s6p) 3P0 optical transition in two odd isotopes of ytterbium. As the excitation laser frequency is scanned, absorption is detected by monitoring the depletion from an atomic cloud at ~70 uK in a magneto-optical trap. The measured frequency in 171Yb (F=1/2) is 518,295,836,593.2 +/- 4.4 kHz. The measured frequency in 173Yb (F=5/2) is 518,294,576,850.0 +/- 4.4 kHz. Measurements are made with a femtosecond-laser frequency comb calibrated by the NIST cesium fountain clock and represent nearly a million-fold reduction in uncertainty. The natural linewidth of these J=0 to J=0 transitions is calculated to be ~10 mHz, making them well-suited to support a new generation of optical atomic clocks based on confinement in an optical lattice.
△ Less
Submitted 31 March, 2005;
originally announced March 2005.