-
The Advanced CCD Imaging Spectrometer on the Chandra X-ray Observatory: twenty-five years of on-orbit operation
Authors:
Catherine E. Grant,
Marshall W. Bautz,
Paul P. Plucinsky,
Peter G. Ford
Abstract:
As the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory completes a quarter century of on orbit operations, it continues to perform well and produce spectacular scientific results. The response of ACIS has evolved over the lifetime of the observatory due to radiation damage, molecular contamination, changing particle environment, and aging of the spacecraft in general. We…
▽ More
As the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory completes a quarter century of on orbit operations, it continues to perform well and produce spectacular scientific results. The response of ACIS has evolved over the lifetime of the observatory due to radiation damage, molecular contamination, changing particle environment, and aging of the spacecraft in general. We present highlights from the instrument team's monitoring program and our expectations for the future of ACIS. Performance changes on ACIS continue to be manageable, and do not indicate any limitations on ACIS lifetime. We examine aspects of the design and operation of ACIS that have impacted its long lifetime with lessons learned for future instruments.
△ Less
Submitted 26 June, 2024;
originally announced June 2024.
-
Fifteen years of the Advanced CCD Imaging Spectrometer
Authors:
Catherine E. Grant,
Mark W. Bautz,
Peter G. Ford,
Paul P. Plucinsky
Abstract:
As the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory enters its fifteenth year of operation on orbit, it continues to perform well and produce spectacular scientific results. The response of ACIS has evolved over the lifetime of the observatory due to radiation damage, molecular contamination and aging of the spacecraft in general. Here we present highlights from the in…
▽ More
As the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory enters its fifteenth year of operation on orbit, it continues to perform well and produce spectacular scientific results. The response of ACIS has evolved over the lifetime of the observatory due to radiation damage, molecular contamination and aging of the spacecraft in general. Here we present highlights from the instrument team's monitoring program and our expectations for the future of ACIS. The ACIS calibration source produces multiple line energies and fully illuminates the entire focal plane which has greatly facilitated the measurement of charge transfer inefficiency and absorption from contamination. While the radioactive decay of the source has decreased its utility, it continues to provide valuable data on the health of the instrument. Performance changes on ACIS continue to be manageable, and do not indicate any limitations on ACIS lifetime.
△ Less
Submitted 24 July, 2014;
originally announced July 2014.
-
Using ACIS on the Chandra X-ray Observatory as a particle radiation monitor II
Authors:
C. E. Grant,
P. G. Ford,
M. W. Bautz,
S. L. O'Dell
Abstract:
The Advanced CCD Imaging Spectrometer is an instrument on the Chandra X-ray Observatory. CCDs are vulnerable to radiation damage, particularly by soft protons in the radiation belts and solar storms. The Chandra team has implemented procedures to protect ACIS during high-radiation events including autonomous protection triggered by an on-board radiation monitor. Elevated temperatures have reduced…
▽ More
The Advanced CCD Imaging Spectrometer is an instrument on the Chandra X-ray Observatory. CCDs are vulnerable to radiation damage, particularly by soft protons in the radiation belts and solar storms. The Chandra team has implemented procedures to protect ACIS during high-radiation events including autonomous protection triggered by an on-board radiation monitor. Elevated temperatures have reduced the effectiveness of the on-board monitor. The ACIS team has developed an algorithm which uses data from the CCDs themselves to detect periods of high radiation and a flight software patch to apply this algorithm is currently active on-board the instrument. In this paper, we explore the ACIS response to particle radiation through comparisons to a number of external measures of the radiation environment. We hope to better understand the efficiency of the algorithm as a function of the flux and spectrum of the particles and the time-profile of the radiation event.
△ Less
Submitted 13 July, 2012;
originally announced July 2012.
-
Discovery of Oxygen Kalpha X-ray Emission from the Rings of Saturn
Authors:
Anil Bhardwaj,
Ronald F. Elsner,
J. Hunter Waite, Jr.,
G. Randall Gladstone,
Thomas E. Cravens,
Peter G. Ford
Abstract:
Using the Advanced CCD Imaging Spectrometer (ACIS), the Chandra X-ray Observatory (CXO) observed the Saturnian system for one rotation of the planet (~37 ks) on 20 January, 2004, and again on 26-27 January, 2004. In this letter we report the detection of X-ray emission from the rings of Saturn. The X-ray spectrum from the rings is dominated by emission in a narrow (~130 eV wide) energy band cent…
▽ More
Using the Advanced CCD Imaging Spectrometer (ACIS), the Chandra X-ray Observatory (CXO) observed the Saturnian system for one rotation of the planet (~37 ks) on 20 January, 2004, and again on 26-27 January, 2004. In this letter we report the detection of X-ray emission from the rings of Saturn. The X-ray spectrum from the rings is dominated by emission in a narrow (~130 eV wide) energy band centered on the atomic oxygen K-alpha fluorescence line at 0.53 keV. The X-ray power emitted from the rings in the 0.49-0.62 keV band is 84 MW, which is about one-third of that emitted from Saturn disk in the photon energy range 0.24-2.0 keV. Our analysis also finds a clear detection of X-ray emission from the rings in the 0.49-0.62 keV band in an earlier (14-15 April, 2003) Chandra ACIS observation of Saturn. Fluorescent scattering of solar X-rays from oxygen atoms in the H2O icy ring material is the likely source mechanism for ring X-rays, consistent with the scenario of solar photo-production of a tenuous ring oxygen atmosphere and ionosphere recently discovered by Cassini.
△ Less
Submitted 19 May, 2005;
originally announced May 2005.
-
Chandra Observation of an X-ray Flare at Saturn: Evidence for Direct Solar Control on Saturn's Disk X-ray Emissions
Authors:
Anil Bhardwaj,
Ronald F. Elsner,
J. Hunter Waite Jr,
G. Randall Gladstone,
Thomas E. Cravens,
Peter G. Ford
Abstract:
Saturn was observed by Chandra ACIS-S on 20 and 26-27 January 2004 for one full Saturn rotation (10.7 hr) at each epoch. We report here the first observation of an X-ray flare from Saturn's non-auroral (low-latitude) disk, which is seen in direct response to an M6-class flare emanating from a sunspot that was clearly visible from both Saturn and Earth. Saturn's disk X-ray emissions are found to…
▽ More
Saturn was observed by Chandra ACIS-S on 20 and 26-27 January 2004 for one full Saturn rotation (10.7 hr) at each epoch. We report here the first observation of an X-ray flare from Saturn's non-auroral (low-latitude) disk, which is seen in direct response to an M6-class flare emanating from a sunspot that was clearly visible from both Saturn and Earth. Saturn's disk X-ray emissions are found to be variable on time scales of hours to weeks to months, and correlated with solar F10.7 cm flux. Unlike Jupiter, X-rays from Saturn's polar (auroral) region have characteristics similar to those from its disk. This report, combined with earlier studies, establishes that disk X-ray emissions of the giant planets Saturn and Jupiter are directly regulated by processes happening on the Sun. We suggest that these emissions could be monitored to study X-ray flaring from solar active regions when they are on the far side and not visible to Near-Earth space weather satellites.
△ Less
Submitted 5 April, 2005;
originally announced April 2005.
-
High Resolution Gratings Spectroscopy of GRBs 030382 and 041006 with Chandra LETGS
Authors:
N. R. Butler,
G. R. Ricker,
P. G. Ford,
R. K. Vanderspek,
H. L. Marshall,
J. G. Jernigan,
G. P. Garmire,
D. Q. Lamb
Abstract:
We present high resolution X-ray spectroscopy of two recent GRB afterglows observed with the Low Energy Transmission Gratings on Chandra. The afterglows to GRBs 030328 and 041006 are detected beginning 15.33 and 16.8 hours after each burst, respectively, and are observed to fade in time during each ~90 ksec observation. We fit for the continuum emission in each full data set and for the data sli…
▽ More
We present high resolution X-ray spectroscopy of two recent GRB afterglows observed with the Low Energy Transmission Gratings on Chandra. The afterglows to GRBs 030328 and 041006 are detected beginning 15.33 and 16.8 hours after each burst, respectively, and are observed to fade in time during each ~90 ksec observation. We fit for the continuum emission in each full data set and for the data sliced into half and quarter time sections. For both afterglows, the continuum emission is well described by an absorbed power-law model, and the model parameters describing the absorption and spectral slope do not appear to evolve in time. We perform a careful search for deviations from the model continua for the full and time-sliced data and find no evidence for significant (>~3sigma) narrow emission/absorption lines or edges. The lack of detections implies that line emission--if it is a general feature in GRB X-ray afterglows--occurs early (t~0.3 days in the source frame) and/or is short-lived (dt<~10 ksec). We also comment on synchrotron fireball models for the X-ray and optical data.
△ Less
Submitted 17 February, 2005;
originally announced February 2005.
-
The X-ray Afterglows of GRB 020813 and GRB 021004 with Chandra HETGS: Possible Evidence for a Supernova Prior to GRB 020813
Authors:
Nathaniel R. Butler,
Herman L. Marshall,
George R. Ricker,
Roland K. Vanderspek,
Peter G. Ford,
Geoffrey B. Crew,
Donald Q. Lamb,
J. Garrett Jernigan
Abstract:
We report on the detection of an emission line near 1.3 keV, which we associate with blue-shifted hydrogen-like sulfur (S XVI), in a 76.8 ksec Chandra HETGS spectrum of the afterglow of GRB 020813. The line is detected at 3.3 sigma significance. We also find marginal evidence for a line possibly due to hydrogen-like silicon (Si XIV) with the same blue-shift. A line from Fe is not detected, thoug…
▽ More
We report on the detection of an emission line near 1.3 keV, which we associate with blue-shifted hydrogen-like sulfur (S XVI), in a 76.8 ksec Chandra HETGS spectrum of the afterglow of GRB 020813. The line is detected at 3.3 sigma significance. We also find marginal evidence for a line possibly due to hydrogen-like silicon (Si XIV) with the same blue-shift. A line from Fe is not detected, though a very low significance Ni feature may be present. A thermal model fits the data adequately, but a reflection model may provide a better fit. There is marginal evidence that the equivalent width of the S XVI line decrease as the burst fades. We infer from these results that a supernova likely occurred >~ 2 months prior to the GRB. We find no discrete or variable spectral features in the Chandra HETGS spectrum of the GRB 021004 afterglow.
△ Less
Submitted 21 July, 2003; v1 submitted 24 March, 2003;
originally announced March 2003.
-
Monitoring the Health and Safety of the ACIS Instrument On-Board the Chandra X-ray Observatory
Authors:
Shanil N. Virani,
Peter G. Ford,
Joseph M. DePasquale,
Paul P. Plucinsky
Abstract:
The Chandra X-ray Observatory (CXO), NASA's latest ``Great Observatory'', was launched on July 23, 1999 and reached its final orbit on August 7, 1999. The CXO is in a highly elliptical orbit, approximately 140,000 km x 10,000 km, and has a period of approximately 63.5 hours (~2.65 days). Communication with the CXO nominally consists of 1-hour contacts spaced 8-hours apart. Thus, once a communica…
▽ More
The Chandra X-ray Observatory (CXO), NASA's latest ``Great Observatory'', was launched on July 23, 1999 and reached its final orbit on August 7, 1999. The CXO is in a highly elliptical orbit, approximately 140,000 km x 10,000 km, and has a period of approximately 63.5 hours (~2.65 days). Communication with the CXO nominally consists of 1-hour contacts spaced 8-hours apart. Thus, once a communication link has been established, it is very important that the health and safety status of the scientific instruments as well as the Observatory itself be determined as quickly as possible.
In this paper, we focus exclusively on the automated health and safety monitoring scripts developed for the Advanced CCD Imaging Spectrometer (ACIS) to use during those 1-hour contacts. ACIS is one of the two focal plane instruments on-board the CXO. We present an overview of the real-time ACIS Engineering Data Web Page and the alert schemes developed for monitoring the instrument status during each communication contact. A suite of HTML and PERL scripts monitors the instrument hardware house-kee** electronics (i.e., voltages and currents) and temperatures during each contact. If a particular instrument component is performing either above or below pre-established operating parameters, a sequence of email and alert pages are spawned to the Science Operations Team of the Chandra X-ray Observatory Center so that the anomaly can be quickly investigated and corrective actions taken if necessary. We also briefly discuss the tools used to monitor the real-time science telemetry reported by the ACIS flight software.
The authors acknowledge support for this research from NASA contract NAS8-39073.
△ Less
Submitted 6 September, 2002;
originally announced September 2002.
-
Discovery of Soft X-Ray Emission from Io, Europa and the Io Plasma Torus
Authors:
Ronald F. Elsner,
G. Randall Gladstone,
J. Hunter Waite,
Frank J. Crary,
Robert R. Howell,
Robert E. Johnson,
Peter G. Ford,
Albert E. Metzger,
Kevin C. Hurley,
Eric D. Feigelson,
Gordon P. Garmire,
Anil Bhardwaj,
Denis C. Grodent,
Tariq Majeed,
Allyn F. Tennant,
Martin C. Weisskop
Abstract:
We report the discovery of soft (0.25--2 keV) x-ray emission from the Galilean satellites Io and Europa, probably Ganymede, and from the Io Plasma Torus (IPT). Bombardment by energetic (>10 keV) H, O, and S ions from the region of the IPT seems the likely source of the x-ray emission from the Galilean satellites. According to our estimates, fluorescent x-ray emission excited by solar x-rays, eve…
▽ More
We report the discovery of soft (0.25--2 keV) x-ray emission from the Galilean satellites Io and Europa, probably Ganymede, and from the Io Plasma Torus (IPT). Bombardment by energetic (>10 keV) H, O, and S ions from the region of the IPT seems the likely source of the x-ray emission from the Galilean satellites. According to our estimates, fluorescent x-ray emission excited by solar x-rays, even during flares from the active Sun, charge-exchange processes, previously invoked to explain Jupiter's x-ray aurora and cometary x-ray emission, and ion strip** by dust grains fail to account for the observed emission. On the other hand, bremsstrahlung emission of soft X-rays from non-thermal electrons in the few hundred to few thousand eV range may account for a substantial fraction of the observed x-ray flux from the IPT.
△ Less
Submitted 14 February, 2002;
originally announced February 2002.