-
High Precision Measurement of the $^{19}$Ne Half-life using real-time digital acquisition
Authors:
C. Fontbonne,
P. Ujić,
F. de Oliveira Santos,
X. Fléchard,
F. Rotaru,
N. L. Achouri,
V. Girard Alcindor,
B. Bastin,
F. Boulay,
J. B. Briand,
A. M. Sánchez-Benítez,
H. Bouzomita,
C. Borcea,
R. Borcea,
B. Blank,
B. Carniol,
I. Čeliković,
P. Delahaye,
F. Delaunay,
D. Etasse,
G. Fremont,
G. de France,
J. M. Fontbonne,
G. F. Grinyer,
J. Harang
, et al. (12 additional authors not shown)
Abstract:
The half-life of $^{19}$Ne has been measured using a real-time digital multiparametric acquisition system providing an accurate time-stamp and relevant information on the detectors signals for each decay event. An exhaustive offline analysis of the data gave unique access to experimental effects potentially biasing the measurement. After establishing the influence factors impacting the measurement…
▽ More
The half-life of $^{19}$Ne has been measured using a real-time digital multiparametric acquisition system providing an accurate time-stamp and relevant information on the detectors signals for each decay event. An exhaustive offline analysis of the data gave unique access to experimental effects potentially biasing the measurement. After establishing the influence factors impacting the measurement such as after-pulses, pile-up, gain and base line fluctuations, their effects were accurately estimated and the event selection optimized. The resulting half-life, $17.2569\pm0.0019_{(stat)}\pm0.0009_{(syst)}$~s, is the most precise up to now for $^{19}$Ne. It is found in agreement with two recent precise measurements and not consistent with the most recent one [L.J. Broussard {\it et al.}, Phys. Rev. Lett. {\bf112}, 212301 (2014)] by 3.0 standard deviations. The full potential of the technique for nuclei with half-lives of a few seconds is discussed.
△ Less
Submitted 27 September, 2017;
originally announced September 2017.
-
Simulation study on light ions identification methods for carbon beams from 95 to 400 MeV/A
Authors:
S. Salvador,
M. Labalme,
J. M. Fontbonne,
J. Dudouet,
J. Colin,
D. Cussol
Abstract:
Monte Carlo simulations have been performed in order to evaluate the efficiencies of several light ions identification techniques. The detection system was composed with layers of scintillating material to measure either the deposited energy or the time-of-flight of ions produced by nuclear reactions between 12C projectiles and a PMMA target. Well known techniques such as (DELTA) E--Range, (DELTA)…
▽ More
Monte Carlo simulations have been performed in order to evaluate the efficiencies of several light ions identification techniques. The detection system was composed with layers of scintillating material to measure either the deposited energy or the time-of-flight of ions produced by nuclear reactions between 12C projectiles and a PMMA target. Well known techniques such as (DELTA) E--Range, (DELTA) E--E--ToF and (DELTA)E--E are presented and their particle identification efficiencies are compared one to another regarding the generated charge and mass of the particle to be identified. The simulations allowed to change the beam energy matching the ones proposed in an hadron therapy facility, namely from 95 to 400 MeV/A.
△ Less
Submitted 1 October, 2013;
originally announced October 2013.
-
Characterization and performances of a monitoring ionization chamber dedicated to IBA-universal irradiation head for Pencil Beam Scanning
Authors:
C. Courtois,
G. Boissonnat,
C. Brusasco,
J. Colin,
D. Cussol,
J. M. Fontbonne,
B. Marchand,
T. Mertens,
S. De Neuter,
J. Perronnel
Abstract:
Every radiotherapy center has to be equipped with real-time beam monitoring devices. In 2008, the medical application group from the Laboratory of Corpuscular Physics (LPC Caen) developed an Ionization Chamber in collaboration with the company IBA (Ion Beam Applications). This monitoring device called IC2/3 was developed to be used in IBAs universal irradiation head for Pencil Beam Scanning (PBS).…
▽ More
Every radiotherapy center has to be equipped with real-time beam monitoring devices. In 2008, the medical application group from the Laboratory of Corpuscular Physics (LPC Caen) developed an Ionization Chamber in collaboration with the company IBA (Ion Beam Applications). This monitoring device called IC2/3 was developed to be used in IBAs universal irradiation head for Pencil Beam Scanning (PBS). The objectives presented in this article are to characterize the IC2/3 monitor in the energy and ux ranges used in protontherapy. The equipment has been tested with an IBAs cyclotronable to deliver proton beams from 70 to 230 MeV. This beam monitoring device has been validated and is now installed at the Westdeutsches Protonentherapiezentrum Essen protontherapy center (WPE, Germany). The results obtained in both terms of spatial resolution and dose measurements are at least equal to the initials speci cations needed for PBS purposes. The detector measures the dose with a relative precision better than 1% in the range 0.5 Gy/min to 8 Gy/min while the spatial resolution is higher than 250 m. The technology has been patented and ve IC2/3 chambers were delivered to IBA. Nowadays, IBA produces the IC2/3 beam monitoring device as part of its Proteus 235 product
△ Less
Submitted 12 September, 2013; v1 submitted 28 June, 2013;
originally announced June 2013.
-
Double di ffential fragmentation cross sections measurements of 95 MeV/u 12C on thin targets for hadrontherapy
Authors:
J. Dudouet,
D. Juliani,
J. C. Ang elique,
B. Braunn,
J. Colin,
D. Cussol,
Ch. Finck,
J. M. Fontbonne,
H. Gu erin,
P. Henriquet,
J. Krimmer,
M. Labalme,
M. Rousseau,
M. G. Saint-Laurent,
S. Salvador
Abstract:
During therapeutic treatment with heavy ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, an accurate prediction on the fluences of these secondary fragments is necessary. Nowadays, a very limited set of double…
▽ More
During therapeutic treatment with heavy ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, an accurate prediction on the fluences of these secondary fragments is necessary. Nowadays, a very limited set of double di ffential carbon fragmentation cross sections are being measured in the energy range used in hadrontherapy (40 to 400 MeV/u). Therefore, new measurements are performed to determine the double di ffential cross section of carbon on di erent thin targets. This work describes the experimental results of an experiment performed on May 2011 at GANIL. The double di ffential cross sections and the angular distributions of secondary fragments produced in the 12C fragmentation at 95 MeV/u on thin targets (C, CH2, Al, Al2O3, Ti and PMMA) have been measured. The experimental setup will be precisely described, the systematic error study will be explained and all the experimental data will be presented.
△ Less
Submitted 3 June, 2013;
originally announced June 2013.
-
Comparison of two analysis methods for nuclear reaction measurements of 12C +12C interactions at 95 MeV/u for hadrontherapy
Authors:
J. Dudouet,
D. Juliani,
M. Labalme,
J. C. Angélique,
B. Braunn,
J. Colin,
D. Cussol,
Ch. Finck,
J. M. Fontbonne,
H. Guérin,
P. Henriquet,
J. Krimmer,
M. Rousseau,
M. G. Saint-Laurent
Abstract:
During therapeutic treatment with heavier ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, the accuracy must be higher than ($\pm$3% and$\pm$1 mm). Therefore, measurements are performed to determine the double…
▽ More
During therapeutic treatment with heavier ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, the accuracy must be higher than ($\pm$3% and$\pm$1 mm). Therefore, measurements are performed to determine the double differential cross section for different reactions. In this paper, the analysis of data from 12C +12C reactions at 95 MeV/u are presented. The emitted particles are detected with \DeltaEthin-\DeltaEthick-E telescopes made of a stack of two silicon detectors and a CsI crystal. Two different methods are used to identify the particles. One is based on graphical cuts onto the \DeltaE-E maps, the second is based on the so-called KaliVeda method using a functional description of \DeltaE versus E. The results of the two methods will be presented in this paper as well as the comparison between both.
△ Less
Submitted 31 March, 2013;
originally announced April 2013.
-
Elements Discrimination in the Study of Super-Heavy Elements using an Ionization Chamber
Authors:
FULIS Collaboration,
A. Wieloch,
Z. Sosin,
J. Peter,
K. Lojek,
N. Alamanos,
N. Amar,
R. Anne,
J. C. Angelique,
G. Auger,
R. Dayras,
A. Drouart,
J. M. Fontbonne,
A. Gillibert,
S. Grevy,
F. Hanappe,
F. Hannachi,
R. Hue,
A. Khouaja,
T. Legou,
A. Lopez-Martens,
E. Lienard,
L. Manduci,
F. de Oliveira Santos,
G. Politi
, et al. (7 additional authors not shown)
Abstract:
Dedicated ionization chamber was built and installed to measure the energy loss of very heavy nuclei at 2.7 MeV/u produced in fusion reactions in inverse kinematics (beam of 208Pb). After going through the ionization chamber, products of reactions on 12C, 18O targets are implanted in a Si detector. Their identification through their alpha decay chain is ambiguous when their half-life is short. A…
▽ More
Dedicated ionization chamber was built and installed to measure the energy loss of very heavy nuclei at 2.7 MeV/u produced in fusion reactions in inverse kinematics (beam of 208Pb). After going through the ionization chamber, products of reactions on 12C, 18O targets are implanted in a Si detector. Their identification through their alpha decay chain is ambiguous when their half-life is short. After calibration with Pb and Th nuclei, the ionization chamber signal allowed us to resolve these ambiguities. In the search for rare super-heavy nuclei produced in fusion reactions in inverse or symmetric kinematics, such a chamber will provide direct information on the nuclear charge of each implanted nucleus.
△ Less
Submitted 28 July, 2003;
originally announced July 2003.