-
A systematic approach to the Planck LFI end-to-end test and its application to the DPC Level 1 pipeline
Authors:
M. Frailis,
M. Maris,
A. Zacchei,
N. Morisset,
R. Rohlfs,
M. Meharga,
P. Binko,
M. Turler,
S. Galeotta,
F. Gasparo,
E. Franceschi,
R. C. Butler,
O. D'Arcangelo,
S. Fogliani,
A. Gregorio,
S. R. Lowe,
G. Maggio,
M. Malaspina,
N. Mandolesi,
P. Manzato,
F. Pasian,
F. Perrotta,
M. Sandri,
L. Terenzi,
M. Tomasi
, et al. (1 additional authors not shown)
Abstract:
The Level 1 of the Planck LFI Data Processing Centre (DPC) is devoted to the handling of the scientific and housekee** telemetry. It is a critical component of the Planck ground segment which has to strictly commit to the project schedule to be ready for the launch and flight operations. In order to guarantee the quality necessary to achieve the objectives of the Planck mission, the design and…
▽ More
The Level 1 of the Planck LFI Data Processing Centre (DPC) is devoted to the handling of the scientific and housekee** telemetry. It is a critical component of the Planck ground segment which has to strictly commit to the project schedule to be ready for the launch and flight operations. In order to guarantee the quality necessary to achieve the objectives of the Planck mission, the design and development of the Level 1 software has followed the ESA Software Engineering Standards. A fundamental step in the software life cycle is the Verification and Validation of the software. The purpose of this work is to show an example of procedures, test development and analysis successfully applied to a key software project of an ESA mission. We present the end-to-end validation tests performed on the Level 1 of the LFI-DPC, by detailing the methods used and the results obtained. Different approaches have been used to test the scientific and housekee** data processing. Scientific data processing has been tested by injecting signals with known properties directly into the acquisition electronics, in order to generate a test dataset of real telemetry data and reproduce as much as possible nominal conditions. For the HK telemetry processing, validation software have been developed to inject known parameter values into a set of real housekee** packets and perform a comparison with the corresponding timelines generated by the Level 1. With the proposed validation and verification procedure, where the on-board and ground processing are viewed as a single pipeline, we demonstrated that the scientific and housekee** processing of the Planck-LFI raw data is correct and meets the project requirements.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
LFI Radiometric Chain Assembly (RCA) data handling "Rachel"
Authors:
M. Malaspina,
E. Franceschi,
P. Battaglia,
P. Binko,
R. C. Butler,
O. D'Arcangelo,
S. Fogliani,
M. Frailis,
C. Franceschet,
S. Galeotta,
F. Gasparo,
A. Gregorio,
M. Lapolla,
R. Leonardi,
G. Maggio,
N. Mandolesi,
P. Manzato,
M. Maris,
M. Meharga,
P. Meinhold,
N. Morisset,
F. Pasian,
F. Perrotta,
R. Rohlfs,
M. Sandri
, et al. (4 additional authors not shown)
Abstract:
This paper is part of the Prelaunch status LFI papers published on JINST (http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221).
Planck's Low Frequency Instrument is an array of 22 pseudo-correlation radiometers at 30, 44, and 70 GHz. Before integrating the overall array assembly, a first set of tests has been performed for each radiometer chain assembly (RCA), consisting of two radiomete…
▽ More
This paper is part of the Prelaunch status LFI papers published on JINST (http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221).
Planck's Low Frequency Instrument is an array of 22 pseudo-correlation radiometers at 30, 44, and 70 GHz. Before integrating the overall array assembly, a first set of tests has been performed for each radiometer chain assembly (RCA), consisting of two radiometers. In this paper, we describe Rachel, a software application which has been purposely developed and used during the RCA test campaign to carry out both near-realtime on-line data analysis and data storage (in FITS format) of the raw output from the radiometric chains.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Optimization of Planck/LFI on--board data handling
Authors:
M. Maris,
M. Tomasi,
S. Galeotta,
M. Miccolis,
S. Hildebrandt,
M. Frailis,
R. Rohlfs,
N. Morisset,
A. Zacchei,
M. Bersanelli,
P. Binko,
C. Burigana,
R. C. Butler,
F. Cuttaia,
H. Chulani,
O. D'Arcangelo,
S. Fogliani,
E. Franceschi,
F. Gasparo,
F. Gomez,
A. Gregorio,
J. M. Herreros,
R. Leonardi,
P. Leutenegger,
G. Maggio
, et al. (12 additional authors not shown)
Abstract:
To asses stability against 1/f noise, the Low Frequency Instrument (LFI) onboard the Planck mission will acquire data at a rate much higher than the data rate allowed by its telemetry bandwith of 35.5 kbps. The data are processed by an onboard pipeline, followed onground by a reversing step. This paper illustrates the LFI scientific onboard processing to fit the allowed datarate. This is a lossy…
▽ More
To asses stability against 1/f noise, the Low Frequency Instrument (LFI) onboard the Planck mission will acquire data at a rate much higher than the data rate allowed by its telemetry bandwith of 35.5 kbps. The data are processed by an onboard pipeline, followed onground by a reversing step. This paper illustrates the LFI scientific onboard processing to fit the allowed datarate. This is a lossy process tuned by using a set of 5 parameters Naver, r1, r2, q, O for each of the 44 LFI detectors. The paper quantifies the level of distortion introduced by the onboard processing, EpsilonQ, as a function of these parameters. It describes the method of optimizing the onboard processing chain. The tuning procedure is based on a optimization algorithm applied to unprocessed and uncompressed raw data provided either by simulations, prelaunch tests or data taken from LFI operating in diagnostic mode. All the needed optimization steps are performed by an automated tool, OCA2, which ends with optimized parameters and produces a set of statistical indicators, among them the compression rate Cr and EpsilonQ. For Planck/LFI the requirements are Cr = 2.4 and EpsilonQ <= 10% of the rms of the instrumental white noise. To speedup the process an analytical model is developed that is able to extract most of the relevant information on EpsilonQ and Cr as a function of the signal statistics and the processing parameters. This model will be of interest for the instrument data analysis. The method was applied during ground tests when the instrument was operating in conditions representative of flight. Optimized parameters were obtained and the performance has been verified, the required data rate of 35.5 Kbps has been achieved while kee** EpsilonQ at a level of 3.8% of white noise rms well within the requirements.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Level 1 on-ground telemetry handling in Planck LFI
Authors:
A. Zacchei,
M. Frailis,
M. Maris,
N. Morisset,
R. Rohlfs,
M. Meharga,
P. Binko,
M. Turler,
S. Galeotta,
F. Gasparo,
E. Franceschi,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
S. Fogliani,
A. Gregorio,
R. Leonardi,
S. R. Lowe,
D. Maino,
G. Maggio,
M. Malaspina,
N. Mandolesi,
P. Manzato,
P. Meinhold,
L. Mendes
, et al. (9 additional authors not shown)
Abstract:
The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave Background (CMB) by covering the frequency range 30-70 GHz in three bands. The primary instrument data source are the temperature samples acquired by the 22 radiometers mounted on the Planck focal plane. Such samples represent the scientific data of LFI. In addition, the LFI instrument generates the so called housekeepin…
▽ More
The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave Background (CMB) by covering the frequency range 30-70 GHz in three bands. The primary instrument data source are the temperature samples acquired by the 22 radiometers mounted on the Planck focal plane. Such samples represent the scientific data of LFI. In addition, the LFI instrument generates the so called housekee** data by sampling regularly the on-board sensors and registers. The housekee** data provides information on the overall health status of the instrument and on the scientific data quality. The scientific and housekee** data are collected on-board into telemetry packets compliant with the ESA Packet Telemetry standards. They represent the primary input to the first processing level of the LFI Data Processing Centre. In this work we show the software systems which build the LFI Level 1. A real-time assessment system, based on the ESA SCOS 2000 generic mission control system, has the main purpose of monitoring the housekee** parameters of LFI and detect possible anomalies. A telemetry handler system processes the housekee** and scientific telemetry of LFI, generating timelines for each acquisition chain and each housekee** parameter. Such timelines represent the main input to the subsequent processing levels of the LFI DPC. A telemetry quick-look system allows the real-time visualization of the LFI scientific and housekee** data, by also calculating quick statistical functions and fast Fourier transforms. The LFI Level 1 has been designed to support all the mission phases, from the instrument ground tests and calibration to the flight operations, and developed according to the ESA engineering standards.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Off-line radiometric analysis of Planck/LFI data
Authors:
M. Tomasi,
A. Mennella,
S. Galeotta,
S. R. Lowe,
L. Mendes,
R. Leonardi,
F. Villa,
B. Cappellini,
A. Gregorio,
P. Meinhold,
M. Sandri,
F. Cuttaia,
L. Terenzi,
M. Maris,
L. Valenziano,
M. J. Salmon,
M. Bersanelli,
P. Binko,
R. C. Butler,
O. D'Arcangelo,
S. Fogliani,
M. Frailis,
E. Franceschi,
F. Gasparo,
G. Maggio
, et al. (13 additional authors not shown)
Abstract:
The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common pla…
▽ More
The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common platform to use for analyzing the results of the tests performed on the single components of the instrument (RCAs, Radiometric Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA). Moreover, its analysis tools are designed to be used during the flight as well to produce periodic reports on the status of the instrument. The LIFE suite has been developed using a multi-layered, cross-platform approach. It implements a number of analysis modules written in RSI IDL, each accessing the data through a portable and heavily optimized library of functions written in C and C++. One of the most important features of LIFE is its ability to run the same data analysis codes both using ground test data and real flight data as input. The LIFE software suite has been successfully used during the RCA/RAA tests and the Planck Integrated System Tests. Moreover, the software has also passed the verification for its in-flight use during the System Operations Verification Tests, held in October 2008.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
R. J. Davis,
M. Frailis,
S. Galeotta,
A. Gregorio,
C. R. Lawrence,
R. Leonardi,
S. R. Lowe,
N. Mandolesi,
M. Maris,
P. Meinhold,
L. Mendes,
G. Morgante,
M. Sandri,
L. Stringhetti,
L. Terenzi,
M. Tomasi,
L. Valenziano,
F. Villa,
A. Zacchei,
A. Zonca
, et al. (61 additional authors not shown)
Abstract:
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise…
▽ More
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.
△ Less
Submitted 25 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Design and description of the Low Frequency Instrument
Authors:
M. Bersanelli,
N. Mandolesi,
R. C. Butler,
A. Mennella,
F. Villa,
B. Aja,
E. Artal,
E. Artina,
C. Baccigalupi,
M. Balasini,
G. Baldan,
A. Banday,
P. Bastia,
P. Battaglia,
T. Bernardino,
E. Blackhurst,
L. Boschini,
C. Burigana,
G. Cafagna,
B. Cappellini,
F. Cavaliere,
F. Colombo,
G. Crone,
F. Cuttaia,
O. D'Arcangelo
, et al. (87 additional authors not shown)
Abstract:
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI…
▽ More
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.
△ Less
Submitted 19 January, 2010;
originally announced January 2010.
-
Simulating the Zody Emission in the Planck Mission
Authors:
Michele Maris,
Carlo Burigana,
Sandro Fogliani
Abstract:
The increasing sensitivity of cosmic microwave background (CMB) missions will require to significantly improve the accuracy in the subtraction of the various sources of Galactic foreground, from the most relevant components (synchrotron, dust and free-free emission) to those usually considered of minor relevance in CMB experiments. With respect to other Galactic diffuse components, the Zodiacal…
▽ More
The increasing sensitivity of cosmic microwave background (CMB) missions will require to significantly improve the accuracy in the subtraction of the various sources of Galactic foreground, from the most relevant components (synchrotron, dust and free-free emission) to those usually considered of minor relevance in CMB experiments. With respect to other Galactic diffuse components, the Zodiacal Light Emission (ZLE) is peculiar, depending not only on the observing direction but also on the location of the observer within the Solar System: ZLE behaves then as a large scale, time-dependent foreground. Starting from the existing far-infrared ZLE models, we discuss the impact of ZLE contribution in CMB maps and the level of contamination in time ordered data and maps expected from the forthcoming Planck space mission as well as the Planck capability to increase our knowledge of the ZLE properties.
△ Less
Submitted 19 July, 2006;
originally announced July 2006.
-
Zodiacal Light Emission in the PLANCK mission
Authors:
M. Maris,
C. Burigana,
S. Fogliani
Abstract:
The PLANCK satellite, scheduled for launch in 2007, will produce a set of all sky maps in nine frequency bands spanning from 30 GHz to 857 GHz, with an unprecedented sensitivity and resolution. Planets, minor bodies and diffuse interplanetary dust will contribute to the (sub)mm sky emission observed by PLANCK, representing a source of foreground contamination to be removed before extracting the…
▽ More
The PLANCK satellite, scheduled for launch in 2007, will produce a set of all sky maps in nine frequency bands spanning from 30 GHz to 857 GHz, with an unprecedented sensitivity and resolution. Planets, minor bodies and diffuse interplanetary dust will contribute to the (sub)mm sky emission observed by PLANCK, representing a source of foreground contamination to be removed before extracting the cosmological information. The aim of this paper is to assess the expected level of contamination in the survey of the forthcoming PLANCK mission. Starting from existing far-infrared (far-IR) models of the Zodiacal Light Emission (ZLE), we present a new method to simulate the time-dependent level of contamination from ZLE at PLANCK frequencies. We studied the possibility of PLANCK to detect and separate the ZLE contribution from the other astrophysical signals. We discuss the conditions in which PLANCK will be able to increase the existing information on the ZLE and IDP physical properties.
△ Less
Submitted 7 April, 2006; v1 submitted 2 March, 2006;
originally announced March 2006.