Instrumental uncertainties in radiative corrections for the MUSE experiment
Authors:
L. Li,
S. Strauch,
J. C. Bernauer,
W. J. Briscoe,
A. Christopher Ndukwe,
E. Cline,
D. Cohen,
K. Deiters,
E. J. Downie,
I. P. Fernando,
A. Flannery,
R. Gilman,
Y. Ilieva,
M. Kohl,
I. Lavrukhin,
W. Lin,
W. Lorenzon,
S. Lunkenheimer,
P. Mohanmurthy,
J. Nazeer,
M. Nicol,
T. Patel,
A. Prosnyakov,
H. Reid,
P. E. Reimer
, et al. (5 additional authors not shown)
Abstract:
The MUSE experiment at the Paul Scherrer Institute is measuring elastic lepton-proton scattering cross sections in a four-momentum transfer range from $Q^2$ of approximately 0.002 to 0.08 GeV$^2$ using positively and negatively charged electrons and muons. The extraction of the Born cross sections from the experimental data requires radiative corrections. Estimates of the instrumental uncertaintie…
▽ More
The MUSE experiment at the Paul Scherrer Institute is measuring elastic lepton-proton scattering cross sections in a four-momentum transfer range from $Q^2$ of approximately 0.002 to 0.08 GeV$^2$ using positively and negatively charged electrons and muons. The extraction of the Born cross sections from the experimental data requires radiative corrections. Estimates of the instrumental uncertainties in those corrections have been made using the ESEPP event generator. The results depend in particular on the minimum lepton momentum that contributes to the experimental cross section and the fraction of events with hard initial-state radiation that is detected in the MUSE calorimeter and is excluded from the data. These results show that the angular-dependent instrumental uncertainties in radiative corrections to the electron cross section are better than 0.4 % and are negligible for the muon cross section.
△ Less
Submitted 8 January, 2024; v1 submitted 12 July, 2023;
originally announced July 2023.
-
Characterization of Muon and Electron Beams in the Paul Scherrer Institute PiM1 Channel for the MUSE Experiment
Authors:
E. Cline,
W. Lin,
P. Roy,
P. E. Reimer,
K. E. Mesick,
A. Akmal,
A. Alie,
H. Atac,
A. Atencio,
C. Ayerbe Gayoso,
N. Benmouna,
F. Benmokhtar,
J. C. Bernauer,
W. J. Briscoe,
J. Campbell,
D. Cohen,
E. O. Cohen,
C. Collicott,
K. Deiters,
S. Dogra,
E. Downie,
I. P. Fernando,
A. Flannery,
T. Gautam,
D. Ghosal
, et al. (35 additional authors not shown)
Abstract:
The MUon Scattering Experiment, MUSE, at the Paul Scherrer Institute, Switzerland, investigates the proton charge radius puzzle, lepton universality, and two-photon exchange, via simultaneous measurements of elastic muon-proton and electron-proton scattering. The experiment uses the PiM1 secondary beam channel, which was designed for high precision pion scattering measurements. We review the prope…
▽ More
The MUon Scattering Experiment, MUSE, at the Paul Scherrer Institute, Switzerland, investigates the proton charge radius puzzle, lepton universality, and two-photon exchange, via simultaneous measurements of elastic muon-proton and electron-proton scattering. The experiment uses the PiM1 secondary beam channel, which was designed for high precision pion scattering measurements. We review the properties of the beam line established for pions. We discuss the production processes that generate the electron and muon beams, and the simulations of these processes. Simulations of the $π$/$μ$/$e$ beams through the channel using TURTLE and G4beamline are compared. The G4beamline simulation is then compared to several experimental measurements of the channel, including the momentum dispersion at the IFP and target, the shape of the beam spot at the target, and timing measurements that allow the beam momenta to be determined. We conclude that the PiM1 channel can be used for high precision $π$, $μ$, and $e$ scattering.
△ Less
Submitted 15 September, 2021;
originally announced September 2021.
-
Timing Detectors with SiPM read-out for the MUSE Experiment at PSI
Authors:
Tigran Rostomyan,
Ethan Cline,
Ievgen Lavrukhin,
Hamza Atac,
Ariella Atencio,
Jan C. Bernauer,
William J. Briscoe,
Dan Cohen,
Erez O. Cohen,
Cristina Collicott,
Konrad Deiters,
Shraddha Dogra,
Evangeline Downie,
Werner Erni,
Ishara P. Fernando,
Anne Flannery,
Thir Gautam,
Debdeep Ghosal,
Ronald Gilman,
Alexander Golossanov,
Jack Hirschman,
Minjung Kim,
Michael Kohl,
Bernd Krusche,
Lin Li
, et al. (18 additional authors not shown)
Abstract:
The Muon Scattering Experiment at the Paul Scherrer Institut uses a mixed beam of electrons, muons, and pions, necessitating precise timing to identify the beam particles and reactions they cause. We describe the design and performance of three timing detectors using plastic scintillator read out with silicon photomultipliers that have been built for the experiment. The Beam Hodoscope, upstream of…
▽ More
The Muon Scattering Experiment at the Paul Scherrer Institut uses a mixed beam of electrons, muons, and pions, necessitating precise timing to identify the beam particles and reactions they cause. We describe the design and performance of three timing detectors using plastic scintillator read out with silicon photomultipliers that have been built for the experiment. The Beam Hodoscope, upstream of the scattering target, counts the beam flux and precisely times beam particles both to identify species and provide a starting time for time-of-flight measurements. The Beam Monitor, downstream of the scattering target, counts the unscattered beam flux, helps identify background in scattering events, and precisely times beam particles for time-of-flight measurements. The Beam Focus Monitor, mounted on the target ladder under the liquid hydrogen target inside the target vacuum chamber, is used in dedicated runs to sample the beam spot at three points near the target center, where the beam should be focused.
△ Less
Submitted 15 October, 2020; v1 submitted 23 July, 2020;
originally announced July 2020.