-
Light-yield response of liquid scintillators using 2--6 MeV tagged neutrons
Authors:
N. Mauritzson,
K. G. Fissum,
J. R. M. Annand,
H. Perrey,
R. Al Jebali,
A. Backis,
R. Hall-Wilton,
K. Kanaki,
V. Maulerova-Subert,
F. Messi,
R. J. W. Frost,
E. Rofors,
J. Scherzinger
Abstract:
Knowledge of the neutron light-yield response is crucial to the understanding of scintillator-based neutron detectors. In this work, neutrons from 2--6 MeV have been used to study the scintillation light-yield response of the liquid scintillators NE 213A, EJ 305, EJ 331 and EJ 321P using event-by-event waveform digitization. Energy calibration was performed using a GEANT model to locate the edge p…
▽ More
Knowledge of the neutron light-yield response is crucial to the understanding of scintillator-based neutron detectors. In this work, neutrons from 2--6 MeV have been used to study the scintillation light-yield response of the liquid scintillators NE 213A, EJ 305, EJ 331 and EJ 321P using event-by-event waveform digitization. Energy calibration was performed using a GEANT model to locate the edge positions of the Compton distributions produced by gamma-ray sources. The simulated light yield for neutrons from a PuBe source was compared to measured recoil proton distributions, where neutron energy was selected by time-of-flight. This resulted in an energy-dependent Birks parametrization to characterize the non-linear response to the lower energy neutrons. The NE 213A and EJ 305 results agree very well with existing data and are reproduced nicely by the simulation. New results for EJ 331 and EJ 321P, where the simulation also reproduces the data well, are presented.
△ Less
Submitted 24 November, 2023; v1 submitted 31 October, 2023;
originally announced November 2023.
-
Technique for the measurement of intrinsic pulse-shape discrimination for organic scintillators using tagged neutrons
Authors:
N. Mauritzson,
K. G. Fissum,
J. R. M. Annand,
H. Perrey,
R. J. W. Frost,
R. Al Jebali,
A. Backis,
R. Hall-Wilton,
K. Kanaki,
V. Maulerova-Subert,
C. Maurer,
F. Messi,
E. Rofors
Abstract:
Fast-neutron/gamma-ray pulse-shape discrimination has been performed for the organic liquid scintillators NE 213A and EJ 305 using a time-of-flight based neutron-tagging technique and waveform digitization on an event-by-event basis. Gamma-ray sources and a Geant4-based simulation were used to calibrate the scintillation-light yield. The difference in pulse shape for the neutron and gamma-ray even…
▽ More
Fast-neutron/gamma-ray pulse-shape discrimination has been performed for the organic liquid scintillators NE 213A and EJ 305 using a time-of-flight based neutron-tagging technique and waveform digitization on an event-by-event basis. Gamma-ray sources and a Geant4-based simulation were used to calibrate the scintillation-light yield. The difference in pulse shape for the neutron and gamma-ray events was analysed by integrating selected portions of the digitized waveform to produce a figure-of-merit for neutron/gamma-ray separation. This figure-of-merit has been mapped as a function of detector threshold and also of neutron energy determined from time-of-flight. It shows clearly that the well-established pulse-shape discrimination capabilities of NE 213A are superior to those of EJ 305. The extra information provided by the neutron-tagging technique has resulted in a far more detailed assessment of the pulse-shape discrimination capabilities of these organic scintillators.
△ Less
Submitted 2 June, 2022;
originally announced June 2022.
-
Geant4-based calibration of an organic liquid scintillator
Authors:
N. Mauritzson,
K. G. Fissum,
H. Perrey,
J. R. M. Annand,
R. J. W. Frost,
R. Hall-Wilton,
R. Al Jebali,
K. Kanaki,
V. Maulerova,
F. Messi,
E. Rofors
Abstract:
A light-yield calibration of an NE 213A organic liquid scintillator detector has been performed using both monoenergetic and polyenergetic gamma-ray sources. Scintillation light was detected in a photomultiplier tube, and the corresponding pulses were subjected to waveform digitization on an event-by-event basis. The resulting Compton edges have been analyzed using a Geant4 simulation of the detec…
▽ More
A light-yield calibration of an NE 213A organic liquid scintillator detector has been performed using both monoenergetic and polyenergetic gamma-ray sources. Scintillation light was detected in a photomultiplier tube, and the corresponding pulses were subjected to waveform digitization on an event-by-event basis. The resulting Compton edges have been analyzed using a Geant4 simulation of the detector which models both the interactions of the ionizing radiation as well as the transport of scintillation photons. The simulation is calibrated and also compared to well-established prescriptions used to determine the Compton edges, resulting ultimately in light-yield calibration functions. In the process, the simulation-based method produced information on the gain and intrinsic pulse-height resolution of the detector. It also facilitated a previously inaccessible understanding of the systematic uncertainties associated with the calibration of the scintillation-light yield. The simulation-based method was also compared to well-established numerical prescriptions for locating the Compton edges. Ultimately, the simulation predicted as much as 17% lower light-yield calibrations than the prescriptions. These calibrations indicate that approximately 35% of the scintillation light associated with a given gamma-ray reaches the photocathode. It is remarkable how well two 50 year old prescriptions for calibrating scintillation-light yield in organic scintillators have stood the test of time.
△ Less
Submitted 22 October, 2021; v1 submitted 24 September, 2021;
originally announced September 2021.
-
Simulation of the Response of the Solid State Neutron Detector for the European Spallation Source
Authors:
L. Boyd,
E. Rofors,
J. R. M. Annand,
K. G. Fissum,
R. Hall-Wilton,
R. Al Jebali,
K. Kanaki,
K. Livingston,
V. Maulerova,
N. Mauritzson,
R. Montgomery,
H. Perrey,
B. Seitz
Abstract:
The characteristics of the Solid-state Neutron Detector, under development for neutron-scattering measurements at the European Spallation Source, have been simulated with a Geant4-based computer code. The code models the interations of thermal neutrons and ionising radiation in the 6Li-doped scintillating glass of the detector, the production of scintillation light and the transport of optical, sc…
▽ More
The characteristics of the Solid-state Neutron Detector, under development for neutron-scattering measurements at the European Spallation Source, have been simulated with a Geant4-based computer code. The code models the interations of thermal neutrons and ionising radiation in the 6Li-doped scintillating glass of the detector, the production of scintillation light and the transport of optical, scintillation photons through the the scintillator, en route to the photo-cathode of the attached multi-anode photomultiplier. Factors which affect the optical-photon transport, such as surface finish, pixelation of the glass sheet, provision of a front reflector and optical coupling media are compared. Predictions of the detector response are compared with measurements made with neutron and gamma-ray sources, a collimated alpha source and finely collimated beams of 2.5 MeV protons and deuterons.
△ Less
Submitted 11 March, 2021; v1 submitted 29 October, 2020;
originally announced October 2020.
-
Response of a Li-glass/multi-anode photomultiplier detector to collimated thermal-neutron beams
Authors:
E. Rofors,
N. Mauritzson,
H. Perrey,
R. Al Jebali,
J. R. M. Annand,
L. Boyd,
M. J. Christensen,
U. Clemens,
S. Desert,
R. Engels,
K. G. Fissum,
H. Frielinghaus,
C. Gheorghe,
R. Hall-Wilton,
S. Jaksch,
K. Kanaki,
S. Kazi,
G. Kemmerling,
I. Llamas Jansa,
V. Maulerova,
R. Montgomery,
T. Richter,
J. Scherzinger,
B. Seitz,
M. Shetty
Abstract:
The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved perpendicularly through the neutron beams in 0.5 to 1.0 mm horizontal and vertical steps. Scintillation was detected in an 8 X 8 pixel multi-anode photomultiplier tube…
▽ More
The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved perpendicularly through the neutron beams in 0.5 to 1.0 mm horizontal and vertical steps. Scintillation was detected in an 8 X 8 pixel multi-anode photomultiplier tube on an event-by-event basis. In general, several pixels registered large signals at each neutron-beam location. The number of pixels registering signal above a set threshold was investigated, with the maximization of the single-hit efficiency over the largest possible area of the detector as the primary goal. At a threshold of ~50% of the mean of the full-deposition peak, ~80% of the events were registered in a single pixel, resulting in an effective position resolution of ~5 mm in X and Y. Lower thresholds generally resulted in events demonstrating higher pixel multiplicities, but these events could also be localized with ~5 mm position resolution.
△ Less
Submitted 9 December, 2020; v1 submitted 13 October, 2020;
originally announced October 2020.
-
Response of a Li-glass/multi-anode photomultiplier detector to focused proton and deuteron beams
Authors:
E. Rofors,
J. Pallon,
R. Al Jebali,
J. R. M. Annand,
L. Boyd,
M. J. Christensen,
U. Clemens,
S. Desert,
M. Elfman,
R. Engels,
K. G. Fissum,
H. Frielinghaus,
R. Frost,
S. Gardner,
C. Gheorghe,
R. Hall-Wilton,
S. Jaksch,
K. Kanaki,
G. Kemmerling,
P. Kristiansson,
K. Livingston,
V. Maulerova,
N. Mauritzson,
R. Montgomery,
H. Perrey
, et al. (4 additional authors not shown)
Abstract:
The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across the detector in 0.5 mm horizontal and vertical steps perpendicular to the beams. Scintillation light was registered using an 8 by 8 pixel multi-anode photomultiplier tube. The signal amplitudes were recorded for each pixel…
▽ More
The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across the detector in 0.5 mm horizontal and vertical steps perpendicular to the beams. Scintillation light was registered using an 8 by 8 pixel multi-anode photomultiplier tube. The signal amplitudes were recorded for each pixel on an event-by-event basis. Several pixels generally registered considerable signals at each beam location. The number of pixels above set thresholds were investigated, with the optimization of the single-hit efficiency over the largest possible area as the goal. For both beams, at a threshold of ~50% of the mean of the full-deposition peak, ~80% of the events were registered in a single pixel, resulting in an effective position resolution of ~5 mm in X and Y.
△ Less
Submitted 18 May, 2020;
originally announced May 2020.
-
Response of a Li-glass/multi-anode photomultiplier detector to $α$-particles from $^{241}$Am
Authors:
E. Rofors,
H. Perrey,
R. Al Jebali,
J. R. M. Annand,
L. Boyd,
U. Clemens,
S. Desert,
R. Engels,
K. G. Fissum,
H. Frielinghaus,
C. Gheorghe,
R. Hall-Wilton,
S. Jaksch,
A. Jalgén,
K. Kanaki,
G. Kemmerling,
V. Maulerova,
N. Mauritzson,
R. Montgomery,
J. Scherzinger,
B. Seitz
Abstract:
The response of a position-sensitive Li-glass scintillator detector to $α$-particles from a collimated $^{241}$Am source scanned across the face of the detector has been measured. Scintillation light was read out by an 8 X 8 pixel multi-anode photomultiplier and the signal amplitude for each pixel has been recorded for every position on a scan. The pixel signal is strongly dependent on position an…
▽ More
The response of a position-sensitive Li-glass scintillator detector to $α$-particles from a collimated $^{241}$Am source scanned across the face of the detector has been measured. Scintillation light was read out by an 8 X 8 pixel multi-anode photomultiplier and the signal amplitude for each pixel has been recorded for every position on a scan. The pixel signal is strongly dependent on position and in general several pixels will register a signal (a hit) above a given threshold. The effect of this threshold on hit multiplicity is studied, with a view to optimize the single-hit efficiency of the detector.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
Near-threshold $π^-$ photoproduction on the deuteron
Authors:
B. Strandberg,
K. G. Fissum,
J. R. M. Annand,
W. J. Briscoe,
J. Brudvik,
F. Cividini,
L. Clark,
E. J. Downie,
K. England,
G. Feldman,
D. I. Glazier,
K. Hamilton,
K. Hansen,
L. Isaksson,
R. Al Jebali,
M. A. Kovash,
A. E. Kudryavtsev,
V. Lensky,
S. Lipschutz,
M. Lundin,
M. Meshkian,
D. G. Middleton,
L. S. Myers,
D. O'Donnell,
G. V. O'Rielly
, et al. (7 additional authors not shown)
Abstract:
The first experimental investigation of the near-threshold cross section for incoherent $π^-$ photoproduction on the deuteron $γ$ d -> $π^-$ pp is presented. The experimental technique involved detection of the ~131 MeV gamma ray resulting from the radiative capture of photoproduced $π^-$ in the target. The total cross section has been measured using an unpolarized tagged-photon beam, a liquid-deu…
▽ More
The first experimental investigation of the near-threshold cross section for incoherent $π^-$ photoproduction on the deuteron $γ$ d -> $π^-$ pp is presented. The experimental technique involved detection of the ~131 MeV gamma ray resulting from the radiative capture of photoproduced $π^-$ in the target. The total cross section has been measured using an unpolarized tagged-photon beam, a liquid-deuterium target, and three very large NaI(Tl) spectrometers. The data are compared to theoretical models that give insight into the elementary reaction $γ$ n -> $π^-$ p and pion-nucleon and nucleon-nucleon final-state interactions.
△ Less
Submitted 6 December, 2019; v1 submitted 7 December, 2018;
originally announced December 2018.
-
Compton Scattering from the Deuteron above Pion-Production Threshold
Authors:
B. Strandberg,
J. R. M. Annand,
W. Briscoe,
J. Brudvik,
F. Cividini,
L. Clark,
E. J. Downie,
K. England,
G. Feldman,
K. G. Fissum,
D. I. Glazier,
K. Hamilton,
K. Hansen,
L. Isaksson,
R. Al Jebali,
M. A. Kovash,
S. Lipschutz,
M. Lundin,
M. Meshkian,
D. G. Middleton,
L. S. Myers,
D. O'Donnell,
G. O'Rielly,
B. Oussena,
M. F. Preston
, et al. (4 additional authors not shown)
Abstract:
The electromagnetic polarizabilities of the nucleon are fundamental nucleon-structure observables that characterize its response to external electromagnetic fields. The neutron polarizabilities can be accessed from Compton-scattering data on light nuclear targets. Recent measurements of the differential cross section for Compton scattering on the deuteron below the pion-production threshold have d…
▽ More
The electromagnetic polarizabilities of the nucleon are fundamental nucleon-structure observables that characterize its response to external electromagnetic fields. The neutron polarizabilities can be accessed from Compton-scattering data on light nuclear targets. Recent measurements of the differential cross section for Compton scattering on the deuteron below the pion-production threshold have decreased the uncertainties in the neutron polarizabilities, yet the proton polarizabilities remain known substantially more accurately. As the sensitivity of the cross section to the polarizabilities increases with incident photon energy, measurements above the pion threshold may offer a way for an improved determination of the neutron polarizabilities. In this article, the first measurement of the cross section for Compton scattering on the deuteron above the pion-production threshold is presented.
△ Less
Submitted 20 March, 2018;
originally announced March 2018.
-
The light-yield response of a NE-213 liquid-scintillator detector measured using 2 -- 6 MeV tagged neutrons
Authors:
J. Scherzinger,
R. Al Jebali,
J. R. M. Annand,
K. G. Fissum,
R. Hall-Wilton,
K. Kanaki,
M. Lundin,
B. Nilsson,
H. Perrey,
A. Rosborg,
H. Svensson
Abstract:
The response of a NE-213 liquid-scintillator detector has been measured using tagged neutrons from 2--6 MeV originating from an Am/Be neutron source. The neutron energies were determined using the time-of-flight technique. Pulse-shape discrimination was employed to discern between gamma-rays and neutrons. The behavior of both the fast (35 ns) and the combined fast and slow (475 ns) components of t…
▽ More
The response of a NE-213 liquid-scintillator detector has been measured using tagged neutrons from 2--6 MeV originating from an Am/Be neutron source. The neutron energies were determined using the time-of-flight technique. Pulse-shape discrimination was employed to discern between gamma-rays and neutrons. The behavior of both the fast (35 ns) and the combined fast and slow (475 ns) components of the neutron scintillation-light pulses were studied. Three different prescriptions were used to relate the neutron maximum energy-transfer edges to the corresponding recoil-proton scintillation-light yields, and the results were compared to simulations. Parametrizations which predict the fast or total light yield of the scintillation pulses were also tested. Our results agree with both existing data and existing parametrizations. We observe a clear sensitivity to the portion and length of the neutron scintillation-light pulse considered.
△ Less
Submitted 1 November, 2016; v1 submitted 31 August, 2016;
originally announced August 2016.
-
A First Comparison of the responses of a He4-based fast-neutron detector and a NE-213 liquid-scintillator reference detector
Authors:
R. Jebali,
J. Scherzinger,
J. R. M. Annand,
R. Chandra,
G. Davatz,
K. G. Fissum,
H. Friederich,
U. Gendotti,
R. Hall-Wilton,
E. Håkansson,
K. Kanaki,
M. Lundin,
D. Murer,
B. Nilsson,
A. Rosborg,
H. Svensson
Abstract:
A first comparison has been made between the pulse-shape discrimination characteristics of a novel $^{4}$He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between…
▽ More
A first comparison has been made between the pulse-shape discrimination characteristics of a novel $^{4}$He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between neutrons and gamma-rays were investigated. The NE-213 liquid-scintillator reference cell produced a wide range of scintillation-light yields in response to the gamma-ray field of the source. In stark contrast, due to the size and pressure of the $^{4}$He gas volume, the $^{4}$He-based detector registered a maximum scintillation-light yield of 750~keV$_{ee}$ to the same gamma-ray field. Pulse-shape discrimination for particles with scintillation-light yields of more than 750~keV$_{ee}$ was excellent in the case of the $^{4}$He-based detector. Above 750~keV$_{ee}$ its signal was unambiguously neutron, enabling particle identification based entirely upon the amount of scintillation light produced.
△ Less
Submitted 27 April, 2015; v1 submitted 13 February, 2015;
originally announced February 2015.
-
A precision measurement of the $p$($e,e^\prime p\,$)$π^0$ reaction at threshold
Authors:
K. Chirapatpimol,
M. H. Shabestari,
R. A. Lindgren,
L. C. Smith,
J. R. M. Annand,
D. W. Higinbotham,
B. Moffit,
V. Nelyubin,
B. E. Norum,
K. Allada,
K. Aniol,
K. Ardashev,
D. S. Armstrong,
R. A. Arndt,
F. Benmokhtar,
A. M. Bernstein,
W. Bertozzi,
W. J. Briscoe,
L. Bimbot,
A. Camsonne,
J. -P. Chen,
S. Choi,
E. Chudakov,
E. Cisbani,
F. Cusanno
, et al. (69 additional authors not shown)
Abstract:
New results are reported from a measurement of $π^0$ electroproduction near threshold using the $p(e,e^{\prime} p)π^0$ reaction. The experiment was designed to determine precisely the energy dependence of $s-$ and $p-$wave electromagnetic multipoles as a stringent test of the predictions of Chiral Perturbation Theory (ChPT). The data were taken with an electron beam energy of 1192 MeV using a two-…
▽ More
New results are reported from a measurement of $π^0$ electroproduction near threshold using the $p(e,e^{\prime} p)π^0$ reaction. The experiment was designed to determine precisely the energy dependence of $s-$ and $p-$wave electromagnetic multipoles as a stringent test of the predictions of Chiral Perturbation Theory (ChPT). The data were taken with an electron beam energy of 1192 MeV using a two-spectrometer setup in Hall A at Jefferson Lab. For the first time, complete coverage of the $φ^*_π$ and $θ^*_π$ angles in the $p π^0$ center-of-mass was obtained for invariant energies above threshold from 0.5 MeV up to 15 MeV. The 4-momentum transfer $Q^2$ coverage ranges from 0.05 to 0.155 (GeV/c)$^2$ in fine steps. A simple phenomenological analysis of our data shows strong disagreement with $p-$wave predictions from ChPT for $Q^2>0.07$ (GeV/c)$^2$, while the $s-$wave predictions are in reasonable agreement.
△ Less
Submitted 10 April, 2015; v1 submitted 22 January, 2015;
originally announced January 2015.
-
Overcoming High Energy Backgrounds at Pulsed Spallation Sources
Authors:
Nataliia Cherkashyna,
Richard J. Hall-Wilton,
Douglas D. DiJulio,
Anton Khaplanov,
Dorothea Pfeiffer,
Julius Scherzinger,
Carsten P. Cooper-Jensen,
Kevin G. Fissum,
Stuart Ansell,
Erik B. Iverson,
Georg Ehlers,
Franz X. Gallmeier,
Tobias Panzner,
Emmanouela Rantsiou,
Kalliopi Kanaki,
Uwe Filges,
Thomas Kittelmann,
Maddi Extegarai,
Valentina Santoro,
Oliver Kirstein,
Phillip M. Bentley
Abstract:
Instrument backgrounds at neutron scattering facilities directly affect the quality and the efficiency of the scientific measurements that users perform. Part of the background at pulsed spallation neutron sources is caused by, and time-correlated with, the emission of high energy particles when the proton beam strikes the spallation target. This prompt pulse ultimately produces a signal, which ca…
▽ More
Instrument backgrounds at neutron scattering facilities directly affect the quality and the efficiency of the scientific measurements that users perform. Part of the background at pulsed spallation neutron sources is caused by, and time-correlated with, the emission of high energy particles when the proton beam strikes the spallation target. This prompt pulse ultimately produces a signal, which can be highly problematic for a subset of instruments and measurements due to the time-correlated properties, and different to that from reactor sources. Measurements of this background have been made at both SNS (ORNL, Oak Ridge, TN, USA) and SINQ (PSI, Villigen, Switzerland). The background levels were generally found to be low compared to natural background. However, very low intensities of high-energy particles have been found to be detrimental to instrument performance in some conditions. Given that instrument performance is typically characterised by S/N, improvements in backgrounds can both improve instrument performance whilst at the same time delivering significant cost savings. A systematic holistic approach is suggested in this contribution to increase the effectiveness of this. Instrument performance should subsequently benefit.
△ Less
Submitted 10 January, 2015;
originally announced January 2015.
-
New Measurement of Compton Scattering from the Deuteron and an Improved Extraction of the Neutron Electromagnetic Polarizabilities
Authors:
L. S. Myers,
J. R. M. Annand,
J. Brudvik,
G. Feldman,
K. G. Fissum,
H. W. Grießhammer,
K. Hansen,
S. S. Henshaw,
L. Isaksson,
R. Jebali,
M. A. Kovash,
M. Lundin,
J. A. McGovern,
D. G. Middleton,
A. M. Nathan,
D. R. Phillips,
B. Schröder,
S. C. Stave
Abstract:
The electromagnetic polarizabilities of the nucleon are fundamental properties that describe its response to external electric and magnetic fields. They can be extracted from Compton-scattering data --- and have been, with good accuracy, in the case of the proton. In contradistinction, information for the neutron requires the use of Compton scattering from nuclear targets. Here we report a new mea…
▽ More
The electromagnetic polarizabilities of the nucleon are fundamental properties that describe its response to external electric and magnetic fields. They can be extracted from Compton-scattering data --- and have been, with good accuracy, in the case of the proton. In contradistinction, information for the neutron requires the use of Compton scattering from nuclear targets. Here we report a new measurement of elastic photon scattering from deuterium using quasimonoenergetic tagged photons at the MAX IV Laboratory in Lund, Sweden. These first new data in more than a decade effectively double the world dataset. Their energy range overlaps with previous experiments and extends it by 20 MeV to higher energies. An analysis using Chiral Effective Field Theory with dynamical Δ(1232) degrees of freedom shows the data are consistent with and within the world dataset. After demonstrating that the fit is consistent with the Baldin sum rule, extracting values for the isoscalar nucleon polarizabilities and combining them with a recent result for the proton, we obtain the neutron polarizabilities as α_n = [11.55 +/- 1.25(stat) +/- 0.2(BSR) +/- 0.8(th)] X 10^{-4} fm^3 and β_n = [3.65 -/+ 1.25(stat) +/- 0.2(BSR) -/+ 0.8(th)] X 10^{-4} fm3, with χ^2 = 45.2 for 44 degrees of freedom.
△ Less
Submitted 13 November, 2014; v1 submitted 12 September, 2014;
originally announced September 2014.
-
Tagging fast neutrons from an 241Am/9Be source
Authors:
J. Scherzinger,
J. R. M. Annand,
G. Davatz,
K. G. Fissum,
U. Gendotti,
R. Hall-Wilton,
A. Rosborg,
E. Håkansson,
R. Jebali,
K. Kanaki,
M. Lundin,
B. Nilsson,
H. Svensson
Abstract:
We report on an investigation of the fast-neutron spectrum emitted by 241Am/9Be. Well-understood shielding, coincidence, and time-of-flight measurement techniques are employed to produce a continuous, polychromatic, energy-tagged neutron beam.
We report on an investigation of the fast-neutron spectrum emitted by 241Am/9Be. Well-understood shielding, coincidence, and time-of-flight measurement techniques are employed to produce a continuous, polychromatic, energy-tagged neutron beam.
△ Less
Submitted 3 January, 2015; v1 submitted 12 May, 2014;
originally announced May 2014.
-
Compton scattering from 12C using tagged photons in the energy range 65 - 115 MeV
Authors:
L. S. Myers,
K. Shoniyozov,
M. F. Preston,
M. D. Anderson,
J. R. M. Annand,
M. Boselli,
W. J. Briscoe,
J. Brudvik,
J. I. Capone,
G. Feldman,
K. G. Fissum,
K. Hansen,
S. S. Henshaw,
L. Isaksson,
R. Jebali,
M. A. Kovash,
K. Lewis,
M. Lundin,
I. J. D. MacGregor,
D. G. Middleton,
D. E. Mittelberger,
M. Murray,
A. M. Nathan,
S. Nutbeam,
G. V. O'Rielly
, et al. (4 additional authors not shown)
Abstract:
Elastic scattering of photons from 12C has been investigated using quasi-monoenergetic tagged photons with energies in the range 65 - 115 MeV at laboratory angles of 60 deg, 120 deg, and 150 deg at the Tagged-Photon Facility at the MAX IV Laboratory in Lund, Sweden. A phenomenological model was employed to provide an estimate of the sensitivity of the 12C(g,g)12C cross section to the bound-nucleon…
▽ More
Elastic scattering of photons from 12C has been investigated using quasi-monoenergetic tagged photons with energies in the range 65 - 115 MeV at laboratory angles of 60 deg, 120 deg, and 150 deg at the Tagged-Photon Facility at the MAX IV Laboratory in Lund, Sweden. A phenomenological model was employed to provide an estimate of the sensitivity of the 12C(g,g)12C cross section to the bound-nucleon polarizabilities.
△ Less
Submitted 16 January, 2014;
originally announced January 2014.
-
Tests of the Monte Carlo Simulation of the Photon-Tagger Focal-Plane Electronics at the MAX IV Laboratory
Authors:
M. F. Preston,
L. S. Myers,
J. R. M. Annand,
K. G. Fissum,
K. Hansen,
L. Isaksson,
R. Jebali,
M. Lundin
Abstract:
Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory were recently investigated using the novel approach of Monte Carlo simulation to allow for normalization of high-rate experimental data acquired with single-hit time-to-digital converters (TDCs). The instrumentation of the tagger focal plane has now been expanded to include multi-hit TDCs.…
▽ More
Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory were recently investigated using the novel approach of Monte Carlo simulation to allow for normalization of high-rate experimental data acquired with single-hit time-to-digital converters (TDCs). The instrumentation of the tagger focal plane has now been expanded to include multi-hit TDCs. The agreement between results obtained from data taken using single-hit and multi-hit TDCs demonstrate a thorough understanding of the behavior of the detector system.
△ Less
Submitted 22 November, 2013;
originally announced November 2013.
-
Monte Carlo Simulation of the Photon-Tagger Focal-Plane Electronics at the MAX IV Laboratory
Authors:
L. S. Myers,
G. Feldman,
K. G. Fissum,
L. Isaksson,
M. A. Kovash,
A. M. Nathan,
R. E. Pywell,
B. Schröder
Abstract:
Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory have been investigated using the novel approach of Monte Carlo simulation. Results are compared to analytical calculations as well as experimental data for both specialized testing and production running to demonstrate a thorough understanding of the behavior of the detector system.
Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory have been investigated using the novel approach of Monte Carlo simulation. Results are compared to analytical calculations as well as experimental data for both specialized testing and production running to demonstrate a thorough understanding of the behavior of the detector system.
△ Less
Submitted 3 August, 2013; v1 submitted 16 March, 2013;
originally announced March 2013.
-
Virtual Compton Scattering and the Generalized Polarizabilities of the Proton at Q^2=0.92 and 1.76 GeV^2
Authors:
H. Fonvieille,
G. Laveissiere,
N. Degrande,
S. Jaminion,
C. Jutier,
L. Todor,
R. Di Salvo,
L. Van Hoorebeke,
L. C. Alexa,
B. D. Anderson,
K. A. Aniol,
K. Arundell,
G. Audit,
L. Auerbach,
F. T. Baker,
M. Baylac,
J. Berthot,
P. Y. Bertin,
W. Bertozzi,
L. Bimbot,
W. U. Boeglin,
E. J. Brash,
V. Breton,
H. Breuer,
E. Burtin
, et al. (139 additional authors not shown)
Abstract:
Virtual Compton Scattering (VCS) on the proton has been studied at Jefferson Lab using the exclusive photon electroproduction reaction (e p --> e p gamma). This paper gives a detailed account of the analysis which has led to the determination of the structure functions P_LL-P_TT/epsilon and P_LT, and the electric and magnetic generalized polarizabilities (GPs) alpha_E(Q^2) and beta_M(Q^2) at value…
▽ More
Virtual Compton Scattering (VCS) on the proton has been studied at Jefferson Lab using the exclusive photon electroproduction reaction (e p --> e p gamma). This paper gives a detailed account of the analysis which has led to the determination of the structure functions P_LL-P_TT/epsilon and P_LT, and the electric and magnetic generalized polarizabilities (GPs) alpha_E(Q^2) and beta_M(Q^2) at values of the four-momentum transfer squared Q^2= 0.92 and 1.76 GeV^2. These data, together with the results of VCS experiments at lower momenta, help building a coherent picture of the electric and magnetic GPs of the proton over the full measured Q^2-range, and point to their non-trivial behavior.
△ Less
Submitted 28 June, 2012; v1 submitted 15 May, 2012;
originally announced May 2012.
-
A measurement of the differential cross section for the two-body photodisintegration of 3He at theta_LAB = 90deg using tagged photons in the energy range 14 -- 31 MeV
Authors:
M. Karlsson,
J. -O. Adler,
L. E. M. Andersson,
V. Avdeichikov,
B. L. Berman,
M. J. Boland,
W. J. Briscoe,
J. Brudvik,
J. R. Calarco,
G. Feldman,
K. G. Fissum,
K. Hansen,
D. L. Hornidge,
L. Isaksson,
N. R. Kolb,
A. A. Kotov,
P. Lilja,
M. Lundin,
B. Nilsson,
D. Nilsson,
G. V. O'Rielly,
G. E. Petrov,
B. Schroder,
I. I. Strakovsky,
L. A. Vaishnene
Abstract:
The two-body photodisintegration of 3He has been investigated using tagged photons with energies from 14 -- 31 MeV at MAX-lab in Lund, Sweden. The two-body breakup channel was unambiguously identified by the (nonsimultaneous) detection of both protons and deuterons. This approach was made feasible by the over-determined kinematic situation afforded by the tagged-photon technique. Proton- and deu…
▽ More
The two-body photodisintegration of 3He has been investigated using tagged photons with energies from 14 -- 31 MeV at MAX-lab in Lund, Sweden. The two-body breakup channel was unambiguously identified by the (nonsimultaneous) detection of both protons and deuterons. This approach was made feasible by the over-determined kinematic situation afforded by the tagged-photon technique. Proton- and deuteron-energy spectra were measured using four silicon surface-barrier detector telescopes located at a laboratory angle of 90deg with respect to the incident photon-beam direction. Average statistical and systematic uncertainties of 5.7% and 6.6% in the differential cross section were obtained for 11 photon-energy bins with an average width of 1.2 MeV. The results are compared to previous experimental data measured at comparable photon energies as well as to the results of two recent Faddeev calculations which employ realistic potential models and take into account three-nucleon forces and final-state interactions. Both the accuracy and precision of the present data are improved over the previous measurements. The data are in good agreement with most of the previous results, and favor the inclusion of three-nucleon forces in the calculations.
△ Less
Submitted 2 September, 2009; v1 submitted 17 March, 2009;
originally announced March 2009.
-
Pion emission in 2H, 12C, 27Al, gamma pi+ reactions at threshold
Authors:
P. Golubev,
V. Avdeichikov,
K. G. Fissum,
B. Jakobsson,
I. A. Pshenichnov,
W. J. Briscoe,
G. V. O'Rielly,
J. Annand,
K. Hansen,
L. Isaksson,
H. Jaederstrom,
M. Karlsson,
M. Lundin,
B. Schroeder,
L. Westerberg
Abstract:
The first data from MAX-lab in Lund, Sweden on pion production in photonuclear reactions at threshold energies, is presented. The decrease of the total yield of pi+ in gamma + 12C, 27Al reactions below 200 MeV as well as differential, dsigma/dOmega, cross sections follow essentially predictions from an intranuclear cascade model with an attractive potential for pion-nucleus interaction in its si…
▽ More
The first data from MAX-lab in Lund, Sweden on pion production in photonuclear reactions at threshold energies, is presented. The decrease of the total yield of pi+ in gamma + 12C, 27Al reactions below 200 MeV as well as differential, dsigma/dOmega, cross sections follow essentially predictions from an intranuclear cascade model with an attractive potential for pion-nucleus interaction in its simplest form. Double differential, d2sigma/dOmegadT, cross sections at 176 MeV show, however, deviations from the model, which call for refinements of nuclear and Coulomb potentials and possibly also for coherent pion production mechanisms.
△ Less
Submitted 19 February, 2008; v1 submitted 9 January, 2008;
originally announced January 2008.
-
The dynamics of the quasielastic 16O(e,e'p) reaction at Q^2 = 0.8 (GeV/c)^2
Authors:
K. G. Fissum
Abstract:
The physics program in Hall A at Jefferson Lab commenced in the summer of 1997 with a detailed investigation of the 16O(e,e'p) reaction in quasielastic, constant (q,w) kinematics at Q^2 ~ 0.8 (GeV/c)^2, q ~ 1 GeV/c, and w ~ 445 MeV. Use of a self-calibrating, self-normalizing, thin-film waterfall target enabled a systematically rigorous measurement. Differential cross-section data for proton kno…
▽ More
The physics program in Hall A at Jefferson Lab commenced in the summer of 1997 with a detailed investigation of the 16O(e,e'p) reaction in quasielastic, constant (q,w) kinematics at Q^2 ~ 0.8 (GeV/c)^2, q ~ 1 GeV/c, and w ~ 445 MeV. Use of a self-calibrating, self-normalizing, thin-film waterfall target enabled a systematically rigorous measurement. Differential cross-section data for proton knockout were obtained for 0 < Emiss < 120 MeV and 0 < pmiss < 350 MeV/c. These results have been used to extract the ALT asymmetry and the RL, RT, RLT, and RL+TT effective response functions. Detailed comparisons of the data with Relativistic Distorted-Wave Impulse Approximation, Relativistic Optical-Model Eikonal Approximation, and Relativistic Multiple-Scattering Glauber Approximation calculations are made. The kinematic consistency of the 1p-shell normalization factors extracted from these data with respect to all available 16O(e,e'p) data is examined. The Q2-dependence of the normalization factors is also discussed.
△ Less
Submitted 3 May, 2005; v1 submitted 19 January, 2004;
originally announced January 2004.
-
The quasielastic 2H(e,e'p)n reaction at high recoil momenta
Authors:
P. E. Ulmer,
K. A. Aniol,
H. Arenhoevel,
J. -P. Chen,
E. Chudakov,
D. Crovelli,
J. M. Finn,
K. G. Fissum,
O. Gayou,
J. Gomez,
J. -O. Hansen,
C. W. de Jager,
S. Jeschonnek,
M. K. Jones,
M. Kuss,
J. J. LeRose,
M. Liang,
R. A. Lindgren,
S. Malov,
D. Meekins,
R. Michaels,
J. Mitchell,
C. F. Perdrisat,
V. Punjabi,
R. Roche
, et al. (5 additional authors not shown)
Abstract:
The 2H(e,e'p)n cross section was measured in Hall A of the Thomas Jefferson National Accelerator Facility (JLab) in quasielastic kinematics (x=0.96) at a four-momentum transfer squared, Q^2=0.67 (GeV/c)^2. The experiment was performed in fixed electron kinematics for recoil momenta from zero to 550 MeV/c. Though the measured cross section deviates by 1-2 sigma from a state-of-the-art calculation…
▽ More
The 2H(e,e'p)n cross section was measured in Hall A of the Thomas Jefferson National Accelerator Facility (JLab) in quasielastic kinematics (x=0.96) at a four-momentum transfer squared, Q^2=0.67 (GeV/c)^2. The experiment was performed in fixed electron kinematics for recoil momenta from zero to 550 MeV/c. Though the measured cross section deviates by 1-2 sigma from a state-of-the-art calculation at low recoil momenta, it agrees at high recoil momenta where final state interactions (FSI) are predicted to be large.
△ Less
Submitted 19 November, 2001;
originally announced November 2001.