In vivo and in vitro study of resorbable magnesium wires for medical implants: Mg purity, surface quality, Zn alloying and polymer coating
Authors:
K. Tesar,
J. Lunackova,
M. Jex,
M. Zaloudkova,
R. Vrbova,
M. Bartos,
P. Klein,
L. Vistejnova,
J. Duskova,
E. Filova,
Z. Sucharda,
M. Steinerova,
S. Habr,
K. Balik,
A. Singh
Abstract:
Magnesium is an excellent material in terms of biocompatibility and its corrosion products can serve as an active source for new bone formation. However, localized corrosion and H2 generation limit the potential of Mg-based implants. Utilizing low-alloyed Mg-Zn wires can strongly reduce problems with large H2 bubbles and improve the mechanical properties considerably while maintaining excellent lo…
▽ More
Magnesium is an excellent material in terms of biocompatibility and its corrosion products can serve as an active source for new bone formation. However, localized corrosion and H2 generation limit the potential of Mg-based implants. Utilizing low-alloyed Mg-Zn wires can strongly reduce problems with large H2 bubbles and improve the mechanical properties considerably while maintaining excellent long-term biocompatibility. Acidic pickling and a polymer coating can be effectively used to lower the rate of in vivo degradation. In this work, microstructural, mechanical, and in vitro characterization of 250 um and 300 um extruded wires made from ultra-pure Mg, commercially pure Mg, Mg-0.15Zn, Mg-0.4Zn and Mg-1Zn was performed. Additionally, Mg-0.4Zn wires together with a variant coated with a copolymer of L-lactide and ε-caprolactone were tested in vivo on artificially damaged Wistar rat femurs. Based on the observed Mg-induced osteogenesis, polymer-coated Mg wires with a small addition of Zn are a perspective material for bone-support applications, such as cerclage and fixation wires.
△ Less
Submitted 26 June, 2024;
originally announced June 2024.
Optimal surface topography for cell adhesion is driven by cell membrane mechanics
Authors:
Matej Daniel,
Kristina Eleršič Filipič,
Eva Filová,
Jaroslav Fojt
Abstract:
Titanium surface treated with titanium oxide nanotubes was used in many studies to quantify the effect of surface topography on cell fate. However, the predicted optimal diameter of nanotubes considerably differs among studies. We propose a model that explain cell adhesion to nanostructured surface by considering deformation energy of cell protrusions into titanium nanotubes and adhesion to surfac…
▽ More
Titanium surface treated with titanium oxide nanotubes was used in many studies to quantify the effect of surface topography on cell fate. However, the predicted optimal diameter of nanotubes considerably differs among studies. We propose a model that explain cell adhesion to nanostructured surface by considering deformation energy of cell protrusions into titanium nanotubes and adhesion to surface. The optimal surface topology is defined as a geometry that gives membrane a minimum energy shape. A dimensionless parameter, the cell interaction index, was proposed to describe interplay between the cell membrane bending, intrinsic curvature and strength of cell adhesion. Model simulation show that optimal nanotube diameter ranging from 20 nm to 100 nm (cell interaction index between 0.2 and 1, respectively) is feasible within certain range of parameters describing adhesion and bending energy. The results indicates a possibility to tune the topology of nanostructural surface in order to enhance proliferation and differentation of cells mechanically compatible with given surface geometry while suppress the growth of other mechanically incompatible cells.
△ Less
Submitted 30 June, 2020;
originally announced June 2020.