The Forward Time Projection Chamber (FTPC) in STAR
Authors:
K. H. Ackermann,
F. Bieser,
F. P. Brady,
D. Cebra,
J. E. Draper,
V. Eckardt,
T. Eggert,
H. Fessler,
K. J. Foley,
V. Ghazikhanian,
T. J. Hallman,
M. Heffner,
H. Huemmler,
J. Klay,
S. R. Klein,
A. Lebedev,
M. J. LeVine,
T. Ljubicic,
G. Lo Curto,
R. S. Longacre,
M. Oldenburg,
HG. Ritter,
J. L. Romero,
N. Schmitz,
A. Schuettauf
, et al. (5 additional authors not shown)
Abstract:
Two cylindrical forward TPC detectors are described which were constructed to extend the phase space coverage of the STAR experiment to the region 2.5 < |η| < 4.0. For optimal use of the available space and in order to cope with the high track density of central Au+Au collisions at RHIC, a novel design was developed using radial drift in a low diffusion gas. From prototype measurements a 2-track…
▽ More
Two cylindrical forward TPC detectors are described which were constructed to extend the phase space coverage of the STAR experiment to the region 2.5 < |η| < 4.0. For optimal use of the available space and in order to cope with the high track density of central Au+Au collisions at RHIC, a novel design was developed using radial drift in a low diffusion gas. From prototype measurements a 2-track resolution of 1-2 mm is expected.
△ Less
Submitted 15 November, 2002;
originally announced November 2002.
Calibration of the STAR Forward Time Projection Chamber with Krypton-83m
Authors:
V. Eckardt,
T. Eggert,
H. Fessler,
H. Hümmler,
G. Lo Curto,
M. Oldenburg,
N. Schmitz,
A. Schüttauf,
J. Seyboth,
P. Seyboth,
M. Vidal
Abstract:
The principles of the calibration of a time projection chamber with radioactive Krypton-83 are explained. The calculation of gain correction factors and the methods of obtaining a precise energy calibration are illustrated. The properties and advantages of \nuc{83m}{Kr} are summarized and compared to other radioactive calibration sources. It was shown that the Krypton calibration for the STAR FT…
▽ More
The principles of the calibration of a time projection chamber with radioactive Krypton-83 are explained. The calculation of gain correction factors and the methods of obtaining a precise energy calibration are illustrated. The properties and advantages of \nuc{83m}{Kr} are summarized and compared to other radioactive calibration sources. It was shown that the Krypton calibration for the STAR FTPC is feasible and recommendable although the pad geometry of the FTPC causes a considerable deterioration of the measured spectrum due to only partially detected charge clusters.
△ Less
Submitted 31 January, 2001; v1 submitted 30 January, 2001;
originally announced January 2001.