-
Search for fractionally charged particles with CUORE
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
J. Cao,
S. Capelli,
C. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi
, et al. (95 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5$\;$cm$\times$5$\;$cm$\times$5$\;$cm TeO$_2$ crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in $^{130}$Te. Unprecedented in size amongst cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic through-going particles. Using th…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5$\;$cm$\times$5$\;$cm$\times$5$\;$cm TeO$_2$ crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in $^{130}$Te. Unprecedented in size amongst cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic through-going particles. Using the first tonne-year of CUORE's exposure, we perform a search for hypothesized fractionally charged particles (FCPs), which are well-motivated by various Standard Model extensions and would have suppressed interactions with matter. No excess of FCP candidate tracks is observed over background, setting leading limits on the underground FCP flux with charges between $e/24-e/5$ at 90\% confidence level. Using the low background environment and segmented geometry of CUORE, we establish the sensitivity of tonne-scale sub-Kelvin detectors to diverse signatures of new physics.
△ Less
Submitted 18 June, 2024;
originally announced June 2024.
-
Data-driven background model for the CUORE experiment
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
J. Cao,
S. Capelli,
C. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi
, et al. (93 additional authors not shown)
Abstract:
We present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth explo…
▽ More
We present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth exploration of both spatial and time dependence of backgrounds. We achieve high sensitivity to both bulk and surface activities of the materials of the setup, detecting levels as low as 10 nBq kg$^{-1}$ and 0.1 nBq cm$^{-2}$, respectively. We compare the contamination levels we extract from the background model with prior radio-assay data, which informs future background risk mitigation strategies. The results of this background model play a crucial role in constructing the background budget for the CUPID experiment as it will exploit the same CUORE infrastructure.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
With or without $ν$? Hunting for the seed of the matter-antimatter asymmetry
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
J. Cao,
S. Capelli,
C. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi
, et al. (93 additional authors not shown)
Abstract:
The matter-antimatter asymmetry underlines the incompleteness of the current understanding of particle physics. Neutrinoless double-beta ($0νββ$) decay may help explain this asymmetry, while unveiling the Majorana nature of the neutrino. The CUORE experiment searches for $0νββ$ decay of $^{130}$Te using a tonne-scale cryogenic calorimeter operated at milli-kelvin temperatures. We report no evidenc…
▽ More
The matter-antimatter asymmetry underlines the incompleteness of the current understanding of particle physics. Neutrinoless double-beta ($0νββ$) decay may help explain this asymmetry, while unveiling the Majorana nature of the neutrino. The CUORE experiment searches for $0νββ$ decay of $^{130}$Te using a tonne-scale cryogenic calorimeter operated at milli-kelvin temperatures. We report no evidence for $0νββ$ decay and place a lower limit on the half-life of T$_{1/2}$ $>$ 3.8 $\times$ 10$^{25}$ years (90% C.I.) with over 2 tonne$\cdot$year TeO$_2$ exposure. The tools and techniques developed for this result and the 5 year stable operation of nearly 1000 detectors demonstrate the infrastructure for a next-generation experiment capable of searching for $0νββ$ decay across multiple isotopes.
△ Less
Submitted 5 April, 2024;
originally announced April 2024.
-
Nonlinear Behavior of Josephson Traveling Wave Parametric Amplifiers
Authors:
Claudio Guarcello,
Felix Ahrens,
Guerino Avallone,
Carlo Barone,
Matteo Borghesi,
Luca Callegaro,
Giovanni Carapella,
Anna Paola Caricato,
Iacopo Carusotto,
Alessandro Cian,
Alessandro D'Elia,
Daniele Di Gioacchino,
Emanuele Enrico,
Paolo Falferi,
Luca Fasolo,
Marco Faverzani,
Elena Ferri,
Giovanni Filatrella,
Claudio Gatti,
Andrea Giachero,
Damiano Giubertoni,
Veronica Granata,
Angelo Leo,
Danilo Labranca,
Carlo Ligi
, et al. (18 additional authors not shown)
Abstract:
Recent advancements in quantum technologies and advanced detection experiments have underscored the pressing need for the detection of exceedingly weak signals within the microwave frequency spectrum. Addressing this challenge, the Josephson Traveling Wave Parametric Amplifier (JTWPA) has been proposed as a cryogenic front-end amplifier capable of approaching the quantum noise limit while providin…
▽ More
Recent advancements in quantum technologies and advanced detection experiments have underscored the pressing need for the detection of exceedingly weak signals within the microwave frequency spectrum. Addressing this challenge, the Josephson Traveling Wave Parametric Amplifier (JTWPA) has been proposed as a cryogenic front-end amplifier capable of approaching the quantum noise limit while providing a relevant bandwidth. This research is centered on a comprehensive numerical investigation of the JTWPA, without resorting to simplifications regarding the nonlinearity of the essential components. Specifically, this study focuses on a thorough examination of the system, characterized by coupled nonlinear differential equations representing all components of the device. Proper input and output signals at the device's boundaries are considered. The analysis of the output signals undergoing the parametric amplification process involves a detailed exploration of phase-space dynamics and Fourier spectral analysis of the output voltage. This study is conducted while considering the parameters ruling the response of the device under pump and signal excitations. In addition to the expected signal amplification, the findings reveal that the nonlinear nature of the system can give rise to unforeseen phenomena, depending on the system's operational conditions, which include: the generation of pump tone harmonics, modulation of the signal gain, and incommensurate frequency generation-effects that are not easily accommodated by simplistic linearized approaches
△ Less
Submitted 3 March, 2024;
originally announced March 2024.
-
Development of KI-TWPAs for the DARTWARS project
Authors:
Felix Ahrens,
Elena Ferri,
Guerino Avallone,
Carlo Barone,
Matteo Borghesi,
Luca Callegaro,
Giovanni Carapella,
Anna Paola Caricato,
Iacopo Carusotto,
Alessandro Cian,
Alessandro D'Elia,
Daniele Di Gioacchino,
Emanuele Enrico,
Paolo Falferi,
Luca Fasolo,
Marco Faverzani,
Giovanni Filatrella,
Claudio Gatti,
Andrea Giachero,
Damiano Giubertoni,
Veronica Granata,
Claudio Guarcello,
Danilo Labranca,
Angelo Leo,
Carlo Ligi
, et al. (18 additional authors not shown)
Abstract:
Noise at the quantum limit over a broad bandwidth is a fundamental requirement for future cryogenic experiments for neutrino mass measurements, dark matter searches and Cosmic Microwave Background (CMB) measurements as well as for fast high-fidelity read-out of superconducting qubits. In the last years, Josephson Parametric Amplifiers (JPA) have demonstrated noise levels close to the quantum limit…
▽ More
Noise at the quantum limit over a broad bandwidth is a fundamental requirement for future cryogenic experiments for neutrino mass measurements, dark matter searches and Cosmic Microwave Background (CMB) measurements as well as for fast high-fidelity read-out of superconducting qubits. In the last years, Josephson Parametric Amplifiers (JPA) have demonstrated noise levels close to the quantum limit, but due to their narrow bandwidth, only few detectors or qubits per line can be read out in parallel. An alternative and innovative solution is based on superconducting parametric amplification exploiting the travelling-wave concept. Within the DARTWARS (Detector Array Readout with Travelling Wave AmplifieRS) project, we develop Kinetic Inductance Travelling-Wave Parametric Amplifiers (KI-TWPAs) for low temperature detectors and qubit read-out. KI-TWPAs are typically operated in a threewave mixing (3WM) mode and are characterised by a high gain, a high saturation power, a large amplification bandwidth and nearly quantum limited noise performance. The goal of the DARTWARS project is to optimise the KI-TWPA design, explore new materials, and investigate alternative fabrication processes in order to enhance the overall performance of the amplifier. In this contribution we present the advancements made by the DARTWARS collaboration to produce a working prototype of a KI-TWPA, from the fabrication to the characterisation.
△ Less
Submitted 19 February, 2024;
originally announced February 2024.
-
Broadband parametric amplification in DARTWARS
Authors:
Marco Faverzani,
Pietro Campana,
Rodolfo Carobene,
Marco Gobbo,
Felix Ahrens,
Guerino Avallone,
Carlo Barone,
Matteo Borghesi,
Silvia Capelli,
Giovanni Carapella,
Anna Paola Caricato,
Luca Callegaro,
Iacopo Carusotto,
Andrea Celotto,
Alessandro Cian,
Alessandro D'Elia,
Daniele Di Gioacchino,
Emanuele Enrico,
Paolo Falferi,
Luca Fasolo,
Elena Ferri,
Giovanni Filatrella,
Claudio Gatti,
Damiano Giubertoni,
Veronica Granata
, et al. (24 additional authors not shown)
Abstract:
Superconducting parametric amplifiers offer the capability to amplify feeble signals with extremely low levels of added noise, potentially reaching quantum-limited amplification. This characteristic makes them essential components in the realm of high-fidelity quantum computing and serves to propel advancements in the field of quantum sensing. In particular, Traveling-Wave Parametric Amplifiers (T…
▽ More
Superconducting parametric amplifiers offer the capability to amplify feeble signals with extremely low levels of added noise, potentially reaching quantum-limited amplification. This characteristic makes them essential components in the realm of high-fidelity quantum computing and serves to propel advancements in the field of quantum sensing. In particular, Traveling-Wave Parametric Amplifiers (TWPAs) may be especially suitable for practical applications due to their multi-Gigahertz amplification bandwidth, a feature lacking in Josephson Parametric Amplifiers (JPAs), despite the latter being a more established technology. This paper presents recent developments of the DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) project, focusing on the latest prototypes of Kinetic Inductance TWPAs (KITWPAs). The project aims to develop a KITWPA capable of achieving $20\,$ dB of amplification. To enhance the production yield, the first prototypes were fabricated with half the length and expected gain of the final device. In this paper, we present the results of the characterization of one of the half-length prototypes. The measurements revealed an average amplification of approximately $9\,$dB across a $2\,$GHz bandwidth for a KITWPA spanning $17\,$mm in length.
△ Less
Submitted 19 February, 2024;
originally announced February 2024.
-
High kinetic inductance NbTiN films for quantum limited travelling wave parametric amplifiers
Authors:
Federica Mantegazzini,
Felix Ahrens,
Matteo Borghesi,
Paolo Falferi,
Luca Fasolo,
Marco Faverzani,
Elena Ferri,
Danilo Labranca,
Benno Margesin,
Renato Mezzena,
Roberto Moretti,
Angelo Nucciotti,
Luca Origo,
Andrea Vinante,
Mario Zannoni,
Andrea Giachero
Abstract:
A wide-bandwidth and low-noise amplification chain in the microwave regime is crucial for the efficient read-out of quantum systems based on superconducting detectors, such as Microwave Kinetic Inductance Detectors (MKIDs), Transition Edge Sensors (TESs), Magnetic Microcalorimeters (MMCs), and RF cavities, as well as qubits. Kinetic Inductance Travelling Wave Parametric Amplifiers (KI-TWPAs) opera…
▽ More
A wide-bandwidth and low-noise amplification chain in the microwave regime is crucial for the efficient read-out of quantum systems based on superconducting detectors, such as Microwave Kinetic Inductance Detectors (MKIDs), Transition Edge Sensors (TESs), Magnetic Microcalorimeters (MMCs), and RF cavities, as well as qubits. Kinetic Inductance Travelling Wave Parametric Amplifiers (KI-TWPAs) operated in a three-wave mixing fashion have demonstrated exceptional dynamic range and low-noise performance, approaching the quantum limit. These amplifiers can be fabricated using a single layer of a high kinetic inductance film as weakly dispersive artificial transmission lines, with the ability to control the phase-matched bandwidth through dispersion engineering. In this study, we present the optimisation of the rf sputter-deposition process of NbTiN films using a Nb80%T20 target, with the goal of achieving precise control over film characteristics, resulting in high kinetic inductance while maintaining a high transition temperature. The parameter landscape related to the different sputtering conditions, such as pressure, power, and nitrogen flow, has been explored and the film thickness has been used as a fine-tuning parameter to adjust the properties of the final NbTiN films used for the fabrication of KI-TWPAs. As a final result, we have obtained a NbTiN film with a kinetic inductance of 8.5 pH/sq which we have exploited to fabricate KI-TWPA prototype devices, showing promising amplification performance.
△ Less
Submitted 18 October, 2023; v1 submitted 17 October, 2023;
originally announced October 2023.
-
Design and simulation of a transmon qubit chip for Axion detection
Authors:
Roberto Moretti,
Hervè Atsè Corti,
Danilo Labranca,
Felix Ahrens,
Guerino Avallone,
Danilo Babusci,
Leonardo Banchi,
Carlo Barone,
Matteo Mario Beretta,
Matteo Borghesi,
Bruno Buonomo,
Enrico Calore,
Giovanni Carapella,
Fabio Chiarello,
Alessandro Cian,
Alessando Cidronali,
Filippo Costa,
Alessandro Cuccoli,
Alessandro D'Elia,
Daniele Di Gioacchino,
Stefano Di Pascoli,
Paolo Falferi,
Marco Fanciulli,
Marco Faverzani,
Giulietto Felici
, et al. (32 additional authors not shown)
Abstract:
Quantum Sensing is a rapidly expanding research field that finds one of its applications in Fundamental Physics, as the search for Dark Matter. Devices based on superconducting qubits have already been successfully applied in detecting few-GHz single photons via Quantum Non-Demolition measurement (QND). This technique allows us to perform repeatable measurements, bringing remarkable sensitivity im…
▽ More
Quantum Sensing is a rapidly expanding research field that finds one of its applications in Fundamental Physics, as the search for Dark Matter. Devices based on superconducting qubits have already been successfully applied in detecting few-GHz single photons via Quantum Non-Demolition measurement (QND). This technique allows us to perform repeatable measurements, bringing remarkable sensitivity improvements and dark count rate suppression in experiments based on high-precision microwave photon detection, such as for Axions and Dark Photons search. In this context, the INFN Qub-IT project goal is to realize an itinerant single-photon counter based on superconducting qubits that will exploit QND for enhancing Axion search experiments. In this study, we present Qub-IT's status towards the realization of its first superconducting qubit device, illustrating design and simulation procedures and the characterization of fabricated Coplanar Waveguide Resonators (CPWs) for readout. We match target qubit parameters and assess a few-percent level agreement between lumped and distributed element simulation models. We reach a maximum internal quality factor of 9.2x10^5 for -92 dBm on-chip readout power.
△ Less
Submitted 25 January, 2024; v1 submitted 8 October, 2023;
originally announced October 2023.
-
A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
Authors:
CUPID collaboration,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Campani,
C. Capelli
, et al. (154 additional authors not shown)
Abstract:
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of…
▽ More
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of $^{100}$Mo-enriched Li$_2$MoO$_4$ crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70--90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained outstanding energy resolutions at the 356 keV line from a $^{133}$Ba source with one light detector achieving 0.71(5) keV FWHM, which is -- to our knowledge -- the best ever obtained when compared to $γ$ detectors of any technology in this energy range.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Twelve-crystal prototype of Li$_2$MoO$_4$ scintillating bolometers for CUPID and CROSS experiments
Authors:
CUPID,
CROSS collaborations,
:,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci
, et al. (160 additional authors not shown)
Abstract:
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied…
▽ More
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, $μ$Bq/kg, level of the LMO crystals radioactive contamination by $^{228}$Th and $^{226}$Ra.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Progress in the development of a KITWPA for the DARTWARS project
Authors:
M. Borghesi,
C. Barone,
S. Capelli,
G. Carapella,
A. P. Caricato,
I. Carusotto,
A. Cian,
D. Di Gioacchino,
E. Enrico,
P. Falferi,
L. Fasolo,
M. Faverzani,
E. Ferri,
G. Filatrella,
C. Gatti,
A. Giachero,
D. Giubertoni,
V. Granata,
A. Greco,
C. Guarcello,
D. Labranca,
A. Leo,
C. Ligi,
G. Maccarrone,
F. Mantegazzini
, et al. (16 additional authors not shown)
Abstract:
DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) is a three years project that aims to develop high-performing innovative Traveling Wave Parametric Amplifiers (TWPAs) for low temperature detectors and qubit readout (C-band). The practical development follows two different promising approaches, one based on the Josephson junctions (TWJPA) and the other one based on the kinetic induc…
▽ More
DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) is a three years project that aims to develop high-performing innovative Traveling Wave Parametric Amplifiers (TWPAs) for low temperature detectors and qubit readout (C-band). The practical development follows two different promising approaches, one based on the Josephson junctions (TWJPA) and the other one based on the kinetic inductance of a high-resistivity superconductor (KITWPA). This paper presents the advancements made by the DARTWARS collaboration to produce a first working prototype of a KITWPA.
△ Less
Submitted 27 October, 2022; v1 submitted 22 August, 2022;
originally announced August 2022.
-
Ultra low noise readout with travelling wave parametric amplifiers: the DARTWARS project
Authors:
A. Rettaroli,
C. Barone,
M. Borghesi,
S. Capelli,
G. Carapella,
A. P. Caricato,
I. Carusotto,
A. Cian,
D. Di Gioacchino,
E. Enrico,
P. Falferi,
L. Fasolo,
M. Faverzani,
E. Ferri,
G. Filatrella,
C. Gatti,
A. Giachero,
D. Giubertoni,
V. Granata,
A. Greco,
C. Guarcello,
D. Labranca,
A. Leo,
C. Ligi,
G. Maccarrone
, et al. (16 additional authors not shown)
Abstract:
The DARTWARS project has the goal of develo** high-performing innovative travelling wave parametric amplifiers with high gain, large bandwidth, high saturation power, and nearly quantum-limited noise. The target frequency region for its applications is 5 - 10 GHz, with an expected noise temperature of about 600 mK. The development follows two different approaches, one based on Josephson junction…
▽ More
The DARTWARS project has the goal of develo** high-performing innovative travelling wave parametric amplifiers with high gain, large bandwidth, high saturation power, and nearly quantum-limited noise. The target frequency region for its applications is 5 - 10 GHz, with an expected noise temperature of about 600 mK. The development follows two different approaches, one based on Josephson junctions and one based on kinetic inductance of superconductors. This contribution mainly focuses on the Josephson travelling wave parametric amplifier, presenting its design, preliminary measurements and the test of homogeneity of arrays of Josephson junctions.
△ Less
Submitted 26 July, 2022;
originally announced July 2022.
-
An Energy-dependent Electro-thermal Response Model of CUORE Cryogenic Calorimeter
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
C. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali
, et al. (96 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0νββ$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters operated at $\sim$10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear therm…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0νββ$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters operated at $\sim$10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. We demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.
△ Less
Submitted 28 July, 2022; v1 submitted 9 May, 2022;
originally announced May 2022.
-
New direct limit on neutrinoless double beta decay half-life of $^{128}$Te with CUORE
Authors:
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
C. Capelli,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi
, et al. (95 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) at Laboratori Nazionali del Gran Sasso of INFN in Italy is an experiment searching for neutrinoless double beta (0$νββ$) decay. Its main goal is to investigate this decay in $^{130}$Te, but its ton-scale mass and low background make CUORE sensitive to other rare processes as well. In this work, we present our first results on the search…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) at Laboratori Nazionali del Gran Sasso of INFN in Italy is an experiment searching for neutrinoless double beta (0$νββ$) decay. Its main goal is to investigate this decay in $^{130}$Te, but its ton-scale mass and low background make CUORE sensitive to other rare processes as well. In this work, we present our first results on the search for \nbb decay of $^{128}$Te, the Te isotope with the second highest natural isotopic abundance. We find no evidence for this decay, and using a Bayesian analysis we set a lower limit on the $^{128}$Te \nbb decay half-life of T$_{1/2} > 3.6 \times 10^{24}$ yr (90\% CI). This represents the most stringent limit on the half-life of this isotope, improving by over a factor 30 the previous direct search results, and exceeding those from geochemical experiments for the first time.
△ Less
Submitted 6 May, 2022;
originally announced May 2022.
-
Heisenberg's uncertainty principle in the PTOLEMY project: a theory update
Authors:
PTOLEMY Collaboration,
A. Apponi,
M. G. Betti,
M. Borghesi,
A. Boyarsky,
N. Canci,
G. Cavoto,
C. Chang,
V. Cheianov,
Y. Cheipesh,
W. Chung,
A. G. Cocco,
A. P. Colijn,
N. D'Ambrosio,
N. de Groot,
A. Esposito,
M. Faverzani,
A. Ferella,
E. Ferri,
L. Ficcadenti,
T. Frederico,
S. Gariazzo,
F. Gatti,
C. Gentile,
A. Giachero
, et al. (36 additional authors not shown)
Abstract:
We discuss the consequences of the quantum uncertainty on the spectrum of the electron emitted by the $β$-processes of a tritium atom bound to a graphene sheet. We analyze quantitatively the issue recently raised in [Cheipesh et al., Phys. Rev. D 104, 116004 (2021)], and discuss the relevant time scales and the degrees of freedom that can contribute to the intrinsic spread in the electron energy.…
▽ More
We discuss the consequences of the quantum uncertainty on the spectrum of the electron emitted by the $β$-processes of a tritium atom bound to a graphene sheet. We analyze quantitatively the issue recently raised in [Cheipesh et al., Phys. Rev. D 104, 116004 (2021)], and discuss the relevant time scales and the degrees of freedom that can contribute to the intrinsic spread in the electron energy. We perform careful calculations of the potential between tritium and graphene with different coverages and geometries. With this at hand, we propose possible avenues to mitigate the effect of the quantum uncertainty.
△ Less
Submitted 6 September, 2022; v1 submitted 21 March, 2022;
originally announced March 2022.
-
Search for Neutrinoless $β^+EC$ Decay of $^{120}$Te with CUORE
Authors:
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
C. Capelli,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi
, et al. (96 additional authors not shown)
Abstract:
CUORE is a large scale cryogenic experiment searching for neutrinoless double beta decay ($0νββ$) in $^{130}$Te. The CUORE detector is made of natural tellurium, providing the possibility of rare event searches on isotopes other than $^{130}$Te. In this work we describe a search for neutrinoless positron emitting electron capture ($0νβ^+EC$) decay in $^{120}$Te with a total TeO$_2$ exposure of 355…
▽ More
CUORE is a large scale cryogenic experiment searching for neutrinoless double beta decay ($0νββ$) in $^{130}$Te. The CUORE detector is made of natural tellurium, providing the possibility of rare event searches on isotopes other than $^{130}$Te. In this work we describe a search for neutrinoless positron emitting electron capture ($0νβ^+EC$) decay in $^{120}$Te with a total TeO$_2$ exposure of 355.7 kg $\cdot$ yr, corresponding to 0.2405 kg $\cdot$ yr of $^{120}$Te. Albeit $0 νββ$ with two final state electrons represents the most promising channel, the emission of a positron and two 511-keV $γ$s make $0νβ^+EC$ decay signature extremely clear. To fully exploit the potential offered by the detector modularity we include events with different topology and perform a simultaneous fit of five selected signal signatures. Using blinded data we extract a median exclusion sensitivity of $3.4 \cdot 10^{22}$ yr at 90% Credibility Interval (C.I.). After unblinding we find no evidence of $0νβ^+EC$ signal and set a 90% C.I. Bayesian lower limit of $2.9 \cdot 10^{22}$ yr on $^{120}$Te half-life. This result improves by an order of magnitude the existing limit from the combined analysis of CUORE-0 and Cuoricino.
△ Less
Submitted 18 July, 2022; v1 submitted 16 March, 2022;
originally announced March 2022.
-
Toward CUPID-1T
Authors:
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
K. Ballen,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
C. Capelli,
S. Capelli,
L. Cappelli,
L. Cardani
, et al. (150 additional authors not shown)
Abstract:
Current experiments to search for broken lepton-number symmetry through the observation of neutrinoless double-beta decay ($0\mathrm{νββ}$) provide the most stringent limits on the Majorana nature of neutrinos and the effective Majorana neutrino mass ($m_{ββ}$). The next-generation experiments will focus on the sensitivity to the $0\mathrm{νββ}$ half-life of $\mathcal{O}(10^{27}$--$10^{28}$~years…
▽ More
Current experiments to search for broken lepton-number symmetry through the observation of neutrinoless double-beta decay ($0\mathrm{νββ}$) provide the most stringent limits on the Majorana nature of neutrinos and the effective Majorana neutrino mass ($m_{ββ}$). The next-generation experiments will focus on the sensitivity to the $0\mathrm{νββ}$ half-life of $\mathcal{O}(10^{27}$--$10^{28}$~years$)$ and $m_{ββ}\lesssim15$~meV, which would provide complete coverage of the so-called Inverted Ordering region of the neutrino mass parameter space. By taking advantage of recent technological breakthroughs, new, future calorimetric experiments at the 1-ton scale can increase the sensitivity by at least another order of magnitude, exploring the large fraction of the parameter space that corresponds to the Normal neutrino mass ordering. In case of a discovery, such experiments could provide important insights toward a new understanding of the mechanism of $0\mathrm{νββ}$.
We present here a series of projects underway that will provide advancements in background reduction, cryogenic readout, and physics searches beyond $0\mathrm{νββ}$, all moving toward the next-to-next generation CUPID-1T detector.
△ Less
Submitted 8 April, 2022; v1 submitted 16 March, 2022;
originally announced March 2022.
-
Optimization of the first CUPID detector module
Authors:
CUPID collaboration,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
K. Ballen,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
C. Capelli,
S. Capelli,
L. Cappelli
, et al. (153 additional authors not shown)
Abstract:
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the…
▽ More
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of $α$ particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 $\pm$ 0.2) keV FWHM at the $Q$-value of $^{100}$Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors' mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an $α$ particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.
△ Less
Submitted 13 February, 2022;
originally announced February 2022.
-
The matrix optimum filter for Low Temperature Detectors dead-time reduction
Authors:
Matteo Borghesi,
Marco Faverzani,
Cecilia Ferrari,
Elena Ferri,
Andrea Giachero,
Angelo Nucciotti,
Luca Origo
Abstract:
Experiments aiming at high sensitivities usually demand for a very high statistics in order to reach more precise measurements. However, for those exploiting Low Temperature Detectors (LTDs), a high source activity may represent a drawback, if the events rate becomes comparable with the detector characteristic temporal response. Indeed, since commonly used optimum filtering approaches can only pro…
▽ More
Experiments aiming at high sensitivities usually demand for a very high statistics in order to reach more precise measurements. However, for those exploiting Low Temperature Detectors (LTDs), a high source activity may represent a drawback, if the events rate becomes comparable with the detector characteristic temporal response. Indeed, since commonly used optimum filtering approaches can only process LTDs signals well isolated in time, a non-negligible part of the recorded experimental data-set is discarded and hence constitute the dead-time. In the presented study we demonstrate that, thanks to the matrix optimum filtering approach, the dead-time of an experiment exploiting LTDs can be strongly reduced.
△ Less
Submitted 27 July, 2022; v1 submitted 14 January, 2022;
originally announced January 2022.
-
Detector Array Readout with Traveling Wave Amplifiers
Authors:
A. Giachero,
C. Barone,
M. Borghesi,
G. Carapella,
A. P. Caricato,
I. Carusotto,
W. Chang,
A. Cian,
D. Di Gioacchino,
E. Enrico,
P. Falferi,
L. Fasolo,
M. Faverzani,
E. Ferri,
G. Filatrella,
C. Gatti,
D. Giubertoni,
A. Greco,
C. Kutlu,
A. Leo,
C. Ligi,
G. Maccarrone,
B. Margesin,
G. Maruccio,
A. Matlashov
, et al. (13 additional authors not shown)
Abstract:
Noise at the quantum limit over a large bandwidth is a fundamental requirement for future applications operating at millikelvin temperatures, such as the neutrino mass measurement, the next-generation x-ray observatory, the CMB measurement, the dark matter and axion detection, and the rapid high-fidelity readout of superconducting qubits. The read out sensitivity of arrays of microcalorimeter dete…
▽ More
Noise at the quantum limit over a large bandwidth is a fundamental requirement for future applications operating at millikelvin temperatures, such as the neutrino mass measurement, the next-generation x-ray observatory, the CMB measurement, the dark matter and axion detection, and the rapid high-fidelity readout of superconducting qubits. The read out sensitivity of arrays of microcalorimeter detectors, resonant axion-detectors, and qubits, is currently limited by the noise temperature and bandwidth of the cryogenic amplifiers. The DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) project has the goal of develo** high-performing innovative traveling wave parametric amplifiers (TWPAs) with a high gain, a high saturation power, and a quantum-limited or nearly quantum-limited noise. The practical development follows two different promising approaches, one based on the Josephson junctions and the other one based on the kinetic inductance of a high-resistivity superconductor. In this contribution we present the aims of the project, the adopted design solutions and preliminary results from simulations and measurements.
△ Less
Submitted 2 November, 2021;
originally announced November 2021.
-
Bimodal Approach for Noise Figures of Merit Evaluation in Quantum-Limited Josephson Traveling Wave Parametric Amplifiers
Authors:
L. Fasolo,
C. Barone,
M. Borghesi,
G. Carapella,
A. P. Caricato,
I. Carusotto,
W. Chung,
A. Cian,
D. Di Gioacchino,
E. Enrico,
P. Falferi,
M. Faverzani,
E. Ferri,
G. Filatrella,
C. Gatti,
A. Giachero,
D. Giubertoni,
A. Greco,
C. Kutlu,
A. Leo,
C. Ligi,
P. Livreri,
G. Maccarrone,
B. Margesin,
G. Maruccio
, et al. (15 additional authors not shown)
Abstract:
The advent of ultra-low noise microwave amplifiers revolutionized several research fields demanding quantum-limited technologies. Exploiting a theoretical bimodal description of a linear phase-preserving amplifier, in this contribution we analyze some of the intrinsic properties of a model architecture (i.e., an rf-SQUID based Josephson Traveling Wave Parametric Amplifier) in terms of amplificatio…
▽ More
The advent of ultra-low noise microwave amplifiers revolutionized several research fields demanding quantum-limited technologies. Exploiting a theoretical bimodal description of a linear phase-preserving amplifier, in this contribution we analyze some of the intrinsic properties of a model architecture (i.e., an rf-SQUID based Josephson Traveling Wave Parametric Amplifier) in terms of amplification and noise generation for key case study input states (Fock and coherents). Furthermore, we present an analysis of the output signals generated by the parametric amplification mechanism when thermal noise fluctuations feed the device.
△ Less
Submitted 29 December, 2021; v1 submitted 30 September, 2021;
originally announced September 2021.
-
An acrylic assembly for low temperature detectors
Authors:
M. Biassoni,
C. Brofferio,
M. Faverzani,
E. Ferri,
S. Ghislandi,
S. Milana,
I. Nutini,
V. Pettinacci,
S. Pozzi,
S. Quitadamo
Abstract:
Thermal detectors are a powerful instrument for the search of rare particle physics events. Inorganic crystals are classically used as thermal detectors held in supporting frames made of copper. In this work a novel approach to the operation of thermal detectors is presented, where TeO2 crystals are cooled down to ~ 10 mK in a light structure built with plastic materials. The advantages of this ap…
▽ More
Thermal detectors are a powerful instrument for the search of rare particle physics events. Inorganic crystals are classically used as thermal detectors held in supporting frames made of copper. In this work a novel approach to the operation of thermal detectors is presented, where TeO2 crystals are cooled down to ~ 10 mK in a light structure built with plastic materials. The advantages of this approach are discussed.
△ Less
Submitted 19 September, 2021;
originally announced September 2021.
-
Implementation and Optimization of the PTOLEMY Transverse Drift Electromagnetic Filter
Authors:
A. Apponi,
M. G. Betti,
M. Borghesi,
A. Boscá,
F. Calle,
N. Canci,
G. Cavoto,
C. Chang,
W. Chung,
A. G. Cocco,
A. P. Colijn,
N. D'Ambrosio,
N. de Groot,
M. Faverzani,
A. Ferella,
E. Ferri,
L. Ficcadenti,
P. Garcia-Abia,
G. Garcia Gomez-Tejedor,
S. Gariazzo,
F. Gatti,
C. Gentile,
A. Giachero,
Y. Hochberg,
Y. Kahn
, et al. (31 additional authors not shown)
Abstract:
The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium beta-decay endpoint. This paper details the implementation and optimization methods for successful operation of the filter. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the s…
▽ More
The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium beta-decay endpoint. This paper details the implementation and optimization methods for successful operation of the filter. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to <10 eV (<1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratary (LNGS) in Italy.
△ Less
Submitted 24 January, 2022; v1 submitted 23 August, 2021;
originally announced August 2021.
-
CUORE Opens the Door to Tonne-scale Cryogenics Experiments
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
F. Alessandria,
K. Alfonso,
E. Andreotti,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. Bandac,
T. I. Banks,
G. Bari,
M. Barucci,
J. W. Beeman,
F. Bellini,
G. Benato,
M. Beretta,
A. Bersani,
D. Biare,
M. Biassoni,
F. Bragazzi,
A. Branca,
C. Brofferio,
A. Bryant,
A. Buccheri
, et al. (184 additional authors not shown)
Abstract:
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require eve…
▽ More
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. A brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.
△ Less
Submitted 2 December, 2021; v1 submitted 17 August, 2021;
originally announced August 2021.
-
Processing of non-constant baseline pulses: a matrix technique
Authors:
C. Ferrari,
M. Borghesi,
M. Faverzani,
E. Ferri,
A. Giachero,
A. Nucciotti
Abstract:
For a high source activity experiment, such as HOLMES, non-constant baseline pulses could constitute a great fraction of the data-set. We test the optimal filter matrix technique, proposed to process these pulses, on simulated responses of HOLMES microcalorimeters.
For a high source activity experiment, such as HOLMES, non-constant baseline pulses could constitute a great fraction of the data-set. We test the optimal filter matrix technique, proposed to process these pulses, on simulated responses of HOLMES microcalorimeters.
△ Less
Submitted 26 July, 2021;
originally announced July 2021.
-
Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE
Authors:
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi,
D. Chiesa
, et al. (89 additional authors not shown)
Abstract:
The possibility that neutrinos may be their own antiparticles, unique among the known fundamental particles, arises from the symmetric theory of fermions proposed by Ettore Majorana in 1937. Given the profound consequences of such Majorana neutrinos, among which is a potential explanation for the matter-antimatter asymmetry of the universe via leptogenesis, the Majorana nature of neutrinos command…
▽ More
The possibility that neutrinos may be their own antiparticles, unique among the known fundamental particles, arises from the symmetric theory of fermions proposed by Ettore Majorana in 1937. Given the profound consequences of such Majorana neutrinos, among which is a potential explanation for the matter-antimatter asymmetry of the universe via leptogenesis, the Majorana nature of neutrinos commands intense experimental scrutiny globally; one of the primary experimental probes is neutrinoless double beta ($0 νββ$) decay. Here we show results from the search for $0 νββ$ decay of $^{130}$Te, using the latest advanced cryogenic calorimeters with the CUORE experiment. CUORE, operating just 10 millikelvin above absolute zero, has pushed the state of the art on three frontiers: the sheer mass held at such ultra-low temperatures, operational longevity, and the low levels of ionising radiation emanating from the cryogenic infrastructure. We find no evidence for $0 νββ$ decay and set a lower bound of $T_{1/2}^{0 ν} > 2.2 \times 10^{25}$ years at a 90% credibility interval. We discuss potential applications of the advances made with CUORE to other fields such as direct dark matter, neutrino and nuclear physics searches and large-scale quantum computing, which can benefit from sustained operation of large payloads in a low-radioactivity, ultra-low temperature cryogenic environment.
△ Less
Submitted 11 April, 2022; v1 submitted 14 April, 2021;
originally announced April 2021.
-
Search for Double-Beta Decay of $\mathrm{^{130}Te}$ to the $0^+$ States of $\mathrm{^{130}Xe}$ with CUORE
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Biassoni A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti N. Casali,
E. Celi,
D. Chiesa M. Clemenza S. Copello,
C. Cosmelli,
O. Cremonesi
, et al. (83 additional authors not shown)
Abstract:
The CUORE experiment is a large bolometric array searching for the lepton number violating neutrino-less double beta decay ($0νββ$) in the isotope $\mathrm{^{130}Te}$. In this work we present the latest results on two searches for the double beta decay (DBD) of $\mathrm{^{130}Te}$ to the first $0^{+}_2$ excited state of $\mathrm{^{130}Xe}$: the $0νββ$ decay and the Standard Model-allowed two-neutr…
▽ More
The CUORE experiment is a large bolometric array searching for the lepton number violating neutrino-less double beta decay ($0νββ$) in the isotope $\mathrm{^{130}Te}$. In this work we present the latest results on two searches for the double beta decay (DBD) of $\mathrm{^{130}Te}$ to the first $0^{+}_2$ excited state of $\mathrm{^{130}Xe}$: the $0νββ$ decay and the Standard Model-allowed two-neutrinos double beta decay ($2νββ$). Both searches are based on a 372.5 kg$\times$yr TeO$_2$ exposure. The de-excitation gamma rays emitted by the excited Xe nucleus in the final state yield a unique signature, which can be searched for with low background by studying coincident events in two or more bolometers. The closely packed arrangement of the CUORE crystals constitutes a significant advantage in this regard. The median limit setting sensitivities at 90\% Credible Interval (C.I.) of the given searches were estimated as $\mathrm{S^{0ν}_{1/2} = 5.6 \times 10^{24} \: \mathrm{yr}}$ for the ${0νββ}$ decay and $\mathrm{S^{2ν}_{1/2} = 2.1 \times 10^{24} \: \mathrm{yr}}$ for the ${2νββ}$ decay. No significant evidence for either of the decay modes was observed and a Bayesian lower bound at $90\%$ C.I. on the decay half lives is obtained as: $\mathrm{(T_{1/2})^{0ν}_{0^+_2} > 5.9 \times 10^{24} \: \mathrm{yr}}$ for the $0νββ$ mode and $\mathrm{(T_{1/2})^{2ν}_{0^+_2} > 1.3 \times 10^{24} \: \mathrm{yr}}$ for the $2νββ$ mode. These represent the most stringent limits on the DBD of $^{130}$Te to excited states and improve by a factor $\sim5$ the previous results on this process.
△ Less
Submitted 30 July, 2021; v1 submitted 26 January, 2021;
originally announced January 2021.
-
A novel approach for nearly-coincident events rejection
Authors:
M. Borghesi,
M. De Gerone,
M. Faverzani,
M. Fedkevych,
E. Ferri,
G. Gallucci,
A. Giachero,
A. Nucciotti,
A. Puiu
Abstract:
We present a novel technique, called DSVP (Discrimination through Singular Vectors Projections), to discriminate spurious events within a dataset. The purpose of this paper is to lay down a general procedure which can be tailored for a broad variety of applications. After describing the general concept, we apply the algorithm to the problem of identifying nearly coincident events in low temperatur…
▽ More
We present a novel technique, called DSVP (Discrimination through Singular Vectors Projections), to discriminate spurious events within a dataset. The purpose of this paper is to lay down a general procedure which can be tailored for a broad variety of applications. After describing the general concept, we apply the algorithm to the problem of identifying nearly coincident events in low temperature microcalorimeters in order to push the time resolution close to its intrinsic limit. In fact, from simulated datasets it was possible to achieve an effective time resolution even shorter than the sampling time of the system considered. The obtained results are contextualized in the framework of the HOLMES experiment, which aims at directly measuring the neutrino mass with the calorimetric approach, allowing to significally improve its statistical sensitivity.
△ Less
Submitted 7 May, 2021; v1 submitted 7 January, 2021;
originally announced January 2021.
-
Progress in the development of TES microcalorimeter detectors suitable for neutrino mass measurement
Authors:
A. Giachero,
B. Alpert,
D. T. Becker,
D. A. Bennett,
M. Borghesi,
M. De Gerone,
M. Faverzani,
M. Fedkevych,
E. Ferri,
G. Gallucci,
J. D. Gard,
F. Gatti,
G. C. Hilton,
J. A. B. Mates,
A. Nucciotti,
G. Pessina,
A. Puiu,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R. Vale
Abstract:
The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final configuration, HOLMES will deploy 1000 detectors of low-temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Tran…
▽ More
The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final configuration, HOLMES will deploy 1000 detectors of low-temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Transition Edge Sensors) on SiNx membrane with gold absorbers. Considering the large number of pixels and an event rate of about 300 Hz/pixel, a large multiplexing factor and a large bandwidth are needed. To fulfill this requirement, HOLMES will exploit recent advances in microwave multiplexing. In this contribution, we present the status of the activities in development, the performances of the developed microwave-multiplexed readout system, and the results obtained with the detectors specifically designed for HOLMES in terms of noise, time, and energy resolutions
△ Less
Submitted 7 January, 2021;
originally announced January 2021.
-
Measurement of the 2$νββ$ Decay Half-life of $^{130}$Te with CUORE
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza
, et al. (88 additional authors not shown)
Abstract:
We measured two-neutrino double beta decay of $^{130}$Te using an exposure of 300.7 kg$\cdot$yr accumulated with the CUORE detector. Using a Bayesian analysis to fit simulated spectra to experimental data, it was possible to disentangle all the major background sources and precisely measure the two-neutrino contribution. The half-life is in agreement with past measurements with a strongly reduced…
▽ More
We measured two-neutrino double beta decay of $^{130}$Te using an exposure of 300.7 kg$\cdot$yr accumulated with the CUORE detector. Using a Bayesian analysis to fit simulated spectra to experimental data, it was possible to disentangle all the major background sources and precisely measure the two-neutrino contribution. The half-life is in agreement with past measurements with a strongly reduced uncertainty: $T^{2ν}_{1/2} = 7.71^{+0.08}_{-0.06}\mathrm{(stat.)}^{+0.12}_{-0.15}\mathrm{(syst.)}\times10^{20}$ yr. This measurement is the most precise determination of the $^{130}$Te 2$νββ$ decay half-life to date.
△ Less
Submitted 19 May, 2021; v1 submitted 21 December, 2020;
originally announced December 2020.
-
A CUPID Li$_{2}$$^{100}$MoO$_4$ scintillating bolometer tested in the CROSS underground facility
Authors:
The CUPID Interest Group,
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
Ch. Bourgeois,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. M. Calvo-Mozota,
J. Camilleri
, et al. (156 additional authors not shown)
Abstract:
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 an…
▽ More
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $γ$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$σ$) between $γ$($β$) and $α$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $μ$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2β$ decay in CROSS and CUPID projects.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Characterization of cubic Li$_{2}$$^{100}$MoO$_4$ crystals for the CUPID experiment
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergè,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (147 additional authors not shown)
Abstract:
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta…
▽ More
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta decay search. In this work, we characterised cubic crystals that, compared to the cylindrical crystals used by CUPID-Mo, are more appealing for the construction of tightly packed arrays. We measured an average energy resolution of (6.7$\pm$0.6) keV FWHM in the region of interest, approaching the CUPID target of 5 keV FWHM. We assessed the identification of $α$ particles with and without a reflecting foil that enhances the scintillation light collection efficiency, proving that the baseline design of CUPID already ensures a complete suppression of this $α$-induced background contribution. We also used the collected data to validate a Monte Carlo simulation modelling the light collection efficiency, which will enable further optimisations of the detector.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Novel technique for the study of pile-up events in cryogenic bolometers
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (144 additional authors not shown)
Abstract:
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our ap…
▽ More
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15ms down to time separation between the individual events of about 2ms.
△ Less
Submitted 12 July, 2021; v1 submitted 23 November, 2020;
originally announced November 2020.
-
New results from the CUORE experiment
Authors:
A. Giachero,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi,
D. Chiesa
, et al. (88 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for neutrinoless double-beta ($0νββ$) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO$_2$ crystals arranged in a compact cylindrical structure of 19 towers. Following the completion…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for neutrinoless double-beta ($0νββ$) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO$_2$ crystals arranged in a compact cylindrical structure of 19 towers. Following the completion of the detector construction in August 2016, CUORE began its first physics data run in 2017 at a base temperature of about 10 mK. Following multiple optimization campaigns in 2018, CUORE is currently in stable operating mode. In 2019, CUORE released its 2\textsuperscript{nd} result of the search for $0νββ$ with a TeO$_2$ exposure of 372.5 kg$\cdot$yr and a median exclusion sensitivity to a $^{130}$Te $0νββ$ decay half-life of $1.7\cdot 10^{25}$ yr. We find no evidence for $0νββ$ decay and set a 90\% C.I. (credibility interval) Bayesian lower limit of $3.2\cdot 10^{25}$ yr on the $^{130}$Te $0νββ$ decay half-life. In this work, we present the current status of CUORE's search for $0νββ$, as well as review the detector performance. Finally, we give an update of the CUORE background model and the measurement of the $^{130}$Te two neutrino double-beta ($2νββ$) decay half-life.
△ Less
Submitted 7 January, 2021; v1 submitted 18 November, 2020;
originally announced November 2020.
-
Improved Limit on Neutrinoless Double-Beta Decay in $^{130}$Te with CUORE
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza
, et al. (86 additional authors not shown)
Abstract:
We report new results from the search for neutrinoless double-beta decay in $^{130}$Te with the CUORE detector. This search benefits from a four-fold increase in exposure, lower trigger thresholds and analysis improvements relative to our previous results. We observe a background of $(1.38\pm0.07)\cdot10^{-2}$ counts$/($keV$\cdot$kg$\cdot$yr$)$ in the $0νββ$ decay region of interest and, with a to…
▽ More
We report new results from the search for neutrinoless double-beta decay in $^{130}$Te with the CUORE detector. This search benefits from a four-fold increase in exposure, lower trigger thresholds and analysis improvements relative to our previous results. We observe a background of $(1.38\pm0.07)\cdot10^{-2}$ counts$/($keV$\cdot$kg$\cdot$yr$)$ in the $0νββ$ decay region of interest and, with a total exposure of 372.5 kg$\cdot$yr, we attain a median exclusion sensitivity of $1.7\cdot10^{25}$ yr. We find no evidence for $0νββ$ decay and set a $90\%$ CI Bayesian lower limit of $3.2\cdot10^{25}$ yr on the $^{130}$Te half-life for this process. In the hypothesis that $0νββ$ decay is mediated by light Majorana neutrinos, this results in an upper limit on the effective Majorana mass of 75-350 meV, depending on the nuclear matrix elements used.
△ Less
Submitted 23 December, 2019;
originally announced December 2019.
-
Working principle and demonstrator of microwave-multiplexing for the HOLMES experiment microcalorimeters
Authors:
D. T. Becker,
D. A. Bennett,
M. Biasotti,
M. Borghesi,
V. Ceriale,
M. De Gerone,
M. Faverzani,
E. Ferri,
J. W. Fowler,
G. Gallucci,
J. D. Gard,
A. Giachero,
J. P. Hays-Wehle,
G. C. Hilton,
J. A. B Mates,
A. Nucciotti,
A. Orlando,
G. Pessina,
A. Puiu,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R Vale
Abstract:
The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to measure the end-point energy of the electron capture (EC) decay of $^{163}$Ho with a statistical sensitivity on the neutrino mass as low as $\sim 1$ eV/c$^2$. In…
▽ More
The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to measure the end-point energy of the electron capture (EC) decay of $^{163}$Ho with a statistical sensitivity on the neutrino mass as low as $\sim 1$ eV/c$^2$. In order to acquire the large needed statistics, by kee** the pile-up contribution as low as possible, 1024 transition edge sensors (TESs) with high energy and time resolutions will be employed. Microcalorimeter and bolometer arrays based on transition edge sensor with thousands of pixels are under development for several space-based and ground-based applications, including astrophysics, nuclear and particle physics, and materials science. The common necessary challenge is to develop pratical multiplexing techniques in order to simplify the cryogenics and readout systems. Despite the various multiplexing variants which are being developed have been successful, new approaches are needed to enable scaling to larger pixel counts and faster sensors, as requested for HOLMES, reducing also the cost and complexity of readout. A very novel technique that meets all of these requirements is based on superconducting microwave resonators coupled to radio-frequency Superconducting Quantum Interference Devices, in which the the changes in the TES input current is tranduced to a change in phase of a microwave signal. In this work we introduce the basics of this technique, the design and development of the first two-channel read out system and its performances with the first TES detectors specifically designed for HOLMES. In the last part we explain how to extend this approach scaling to 1024 pixels.
△ Less
Submitted 11 October, 2019;
originally announced October 2019.
-
Results of CUORE
Authors:
S. Dell'Oro,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza
, et al. (87 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) at the Laboratori Nazionali del Gran Sasso, Italy, is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently in data taking, searching for the neutrinoless double beta decay of 130 Te. CUORE is operational since the spring of 2017. The initial sci…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) at the Laboratori Nazionali del Gran Sasso, Italy, is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently in data taking, searching for the neutrinoless double beta decay of 130 Te. CUORE is operational since the spring of 2017. The initial science run already allowed to provide the most stringent limit on the neutrinoless double beta decay half-life of 130Te, and to perform the most precise measurement of the two-neutrino double beta decay half-life. Up to date, we have more than doubled the collected exposure. In this talk, we presenteded the most recent results and discuss the present status of the CUORE experiment.
△ Less
Submitted 18 May, 2019;
originally announced May 2019.
-
The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures
Authors:
C. Alduino,
F. Alessandria,
M. Balata,
D. Biare,
M. Biassoni,
C. Bucci,
A. Caminata,
L. Canonica,
L. Cappelli,
G. Ceruti,
A. Chiarini,
N. Chott,
M. Clemenza,
S. Copello,
A. Corsi,
O. Cremonesi,
A. D'Addabbo,
S. Dell'Oro,
L. Di Paolo,
M. L. Di Vacri,
A. Drobizhev,
M. Faverzani,
E. Ferri,
M. A. Franceschi,
R. Gaigher
, et al. (31 additional authors not shown)
Abstract:
The CUORE experiment is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso, Italy, searching for the neutrinoless double beta decay of 130Te. A large custom cryogen-free cryostat allows reaching and maintaining a base temperature of about 10 mK, requ…
▽ More
The CUORE experiment is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso, Italy, searching for the neutrinoless double beta decay of 130Te. A large custom cryogen-free cryostat allows reaching and maintaining a base temperature of about 10 mK, required for the optimal operation of the detector. This apparatus has been designed in order to achieve a low noise environment, with minimal contribution to the radioactive background for the experiment. In this paper, we present an overview of the CUORE cryostat, together with a description of all its sub-systems, focusing on the solutions identified to satisfy the stringent requirements. We briefly illustrate the various phases of the cryostat commissioning and highlight the relevant steps and milestones achieved each time. Finally, we describe the successful cooldown of CUORE.
△ Less
Submitted 12 July, 2019; v1 submitted 8 April, 2019;
originally announced April 2019.
-
Neutrino physics with the PTOLEMY project: active neutrino properties and the light sterile case
Authors:
PTOLEMY collaboration,
M. G. Betti,
M. Biasotti,
A. Boscá,
F. Calle,
G. Cavoto,
C. Chang,
A. G. Cocco,
A. P. Colijn,
J. Conrad,
N. D'Ambrosio,
N. De Groot,
P. F. de Salas,
M. Faverzani,
A. Ferella,
E. Ferri,
P. Garcia-Abia,
I. García-Cortés,
G. Garcia Gomez-Tejedor,
S. Gariazzo,
F. Gatti,
C. Gentile,
A. Giachero,
J. E. Gudmundsson,
Y. Hochberg
, et al. (32 additional authors not shown)
Abstract:
The PTOLEMY project aims to develop a scalable design for a Cosmic Neutrino Background (CNB) detector, the first of its kind and the only one conceived that can look directly at the image of the Universe encoded in neutrino background produced in the first second after the Big Bang. The scope of the work for the next three years is to complete the conceptual design of this detector and to validate…
▽ More
The PTOLEMY project aims to develop a scalable design for a Cosmic Neutrino Background (CNB) detector, the first of its kind and the only one conceived that can look directly at the image of the Universe encoded in neutrino background produced in the first second after the Big Bang. The scope of the work for the next three years is to complete the conceptual design of this detector and to validate with direct measurements that the non-neutrino backgrounds are below the expected cosmological signal. In this paper we discuss in details the theoretical aspects of the experiment and its physics goals. In particular, we mainly address three issues. First we discuss the sensitivity of PTOLEMY to the standard neutrino mass scale. We then study the perspectives of the experiment to detect the CNB via neutrino capture on tritium as a function of the neutrino mass scale and the energy resolution of the apparatus. Finally, we consider an extra sterile neutrino with mass in the eV range, coupled to the active states via oscillations, which has been advocated in view of neutrino oscillation anomalies. This extra state would contribute to the tritium decay spectrum, and its properties, mass and mixing angle, could be studied by analyzing the features in the beta decay electron spectrum.
△ Less
Submitted 30 September, 2019; v1 submitted 14 February, 2019;
originally announced February 2019.
-
Double-beta decay of ${}^{130}$Te to the first $0^+$ excited state of ${}^{130}$Xe with CUORE-0
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
D. Chiesa
, et al. (96 additional authors not shown)
Abstract:
We report on a search for double beta decay of $^{130}$Te to the first $0^{+}$ excited state of $^{130}$Xe using a 9.8 kg$\cdot$yr exposure of $^{130}$Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double-decay modes. We find no evidence for either mode and place lower bounds on the ha…
▽ More
We report on a search for double beta decay of $^{130}$Te to the first $0^{+}$ excited state of $^{130}$Xe using a 9.8 kg$\cdot$yr exposure of $^{130}$Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double-decay modes. We find no evidence for either mode and place lower bounds on the half-lives: $τ^{0ν}_{0^+}>7.9\cdot 10^{23}$ yr and $τ^{2ν}_{0^+}>2.4\cdot 10^{23}$ yr. Combining our results with those obtained by the CUORICINO experiment, we achieve the most stringent constraints available for these processes: $τ^{0ν}_{0^+}>1.4\cdot 10^{24}$ yr and $τ^{2ν}_{0^+}>2.5\cdot 10^{23}$ yr.
△ Less
Submitted 29 November, 2018; v1 submitted 26 November, 2018;
originally announced November 2018.
-
A Design for an Electromagnetic Filter for Precision Energy Measurements at the Tritium Endpoint
Authors:
M. G. Betti,
M. Biasotti,
A. Bosca,
F. Calle,
J. Carabe-Lopez,
G. Cavoto,
C. Chang,
W. Chung,
A. G. Cocco,
A. P. Colijn,
J. Conrad,
N. D'Ambrosio,
P. F. de Salas,
M. Faverzani,
A. Ferella,
E. Ferri,
P. Garcia-Abia,
G. Garcia Gomez-Tejedor,
S. Gariazzo,
F. Gatti,
C. Gentile,
A. Giachero,
J. Gudmundsson,
Y. Hochberg,
Y. Kahn
, et al. (26 additional authors not shown)
Abstract:
We present a detailed description of the electromagnetic filter for the PTOLEMY project to directly detect the Cosmic Neutrino Background (CNB). Starting with an initial estimate for the orbital magnetic moment, the higher-order drift process of ExB is configured to balance the gradient-B drift motion of the electron in such a way as to guide the trajectory into the standing voltage potential alon…
▽ More
We present a detailed description of the electromagnetic filter for the PTOLEMY project to directly detect the Cosmic Neutrino Background (CNB). Starting with an initial estimate for the orbital magnetic moment, the higher-order drift process of ExB is configured to balance the gradient-B drift motion of the electron in such a way as to guide the trajectory into the standing voltage potential along the mid-plane of the filter. As a function of drift distance along the length of the filter, the filter zooms in with exponentially increasing precision on the transverse velocity component of the electron kinetic energy. This yields a linear dimension for the total filter length that is exceptionally compact compared to previous techniques for electromagnetic filtering. The parallel velocity component of the electron kinetic energy oscillates in an electrostatic harmonic trap as the electron drifts along the length of the filter. An analysis of the phase-space volume conservation validates the expected behavior of the filter from the adiabatic invariance of the orbital magnetic moment and energy conservation following Liouville's theorem for Hamiltonian systems.
△ Less
Submitted 15 October, 2018;
originally announced October 2018.
-
Update on the recent progress of the CUORE experiment
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
D. Chiesa
, et al. (96 additional authors not shown)
Abstract:
CUORE is a 741 kg array of 988 TeO$_2$ bolometeric crystals designed to search for the neutrinoless double beta decay of $^{130}$Te and other rare processes. CUORE has been taking data since summer 2017, and as of summer 2018 collected a total of 86.3 kg$\cdot$yr of TeO$_2$ exposure. Based on this exposure, we were able to set a limit on the $0νββ$ half-life of $^{130}$Te of…
▽ More
CUORE is a 741 kg array of 988 TeO$_2$ bolometeric crystals designed to search for the neutrinoless double beta decay of $^{130}$Te and other rare processes. CUORE has been taking data since summer 2017, and as of summer 2018 collected a total of 86.3 kg$\cdot$yr of TeO$_2$ exposure. Based on this exposure, we were able to set a limit on the $0νββ$ half-life of $^{130}$Te of $T^{0ν}_{1/2}>1.5\times10^{25}$ yr at 90% C.L. At this conference, we showed the decomposition of the CUORE background and were able to extract a $^{130}$Te $2νββ$ half-life of $T_{1/2}^{2ν}=[7.9\pm0.1 \mathrm{(stat.)}\pm0.2 \mathrm{(syst.)}]\times10^{20}$ yr. This is the most precise measurement of this half-life and is consistent with previous measurements.
△ Less
Submitted 30 August, 2018;
originally announced August 2018.
-
PTOLEMY: A Proposal for Thermal Relic Detection of Massive Neutrinos and Directional Detection of MeV Dark Matter
Authors:
E. Baracchini,
M. G. Betti,
M. Biasotti,
A. Bosca,
F. Calle,
J. Carabe-Lopez,
G. Cavoto,
C. Chang,
A. G. Cocco,
A. P. Colijn,
J. Conrad,
N. D'Ambrosio,
P. F. de Salas,
M. Faverzani,
A. Ferella,
E. Ferri,
P. Garcia-Abia,
G. Garcia Gomez-Tejedor,
S. Gariazzo,
F. Gatti,
C. Gentile,
A. Giachero,
J. Gudmundsson,
Y. Hochberg,
Y. Kahn
, et al. (26 additional authors not shown)
Abstract:
We propose to achieve the proof-of-principle of the PTOLEMY project to directly detect the Cosmic Neutrino Background (CNB). Each of the technological challenges described in [1,2] will be targeted and hopefully solved by the use of the latest experimental developments and profiting from the low background environment provided by the LNGS underground site. The first phase will focus on the graphen…
▽ More
We propose to achieve the proof-of-principle of the PTOLEMY project to directly detect the Cosmic Neutrino Background (CNB). Each of the technological challenges described in [1,2] will be targeted and hopefully solved by the use of the latest experimental developments and profiting from the low background environment provided by the LNGS underground site. The first phase will focus on the graphene technology for a tritium target and the demonstration of TES microcalorimetry with an energy resolution of better than 0.05 eV for low energy electrons. These technologies will be evaluated using the PTOLEMY prototype, proposed for underground installation, using precision HV controls to step down the kinematic energy of endpoint electrons to match the calorimeter dynamic range and rate capabilities. The second phase will produce a novel implementation of the EM filter that is scalable to the full target size and which demonstrates intrinsic triggering capability for selecting endpoint electrons. Concurrent with the CNB program, we plan to exploit and develop the unique properties of graphene to implement an intermediate program for direct directional detection of MeV dark matter [3,4]. This program will evaluate the radio-purity and scalability of the graphene fabrication process with the goal of using recently identified ultra-high radio-purity CO2 sources. The direct detection of the CNB is a snapshot of early universe dynamics recorded by the thermal relic neutrino yield taken at a time that predates the epochs of Big Bang Nucleosynthesis, the Cosmic Microwave Background and the recession of galaxies (Hubble Expansion). Big Bang neutrinos are believed to have a central role in the evolution of the Universe and a direct measurement with PTOLEMY will unequivocally establish the extent to which these predictions match present-day neutrino densities.
△ Less
Submitted 6 August, 2018;
originally announced August 2018.
-
Infinite dimensional portfolio representation as applied to model points selection in life insurance
Authors:
Enrico Ferri
Abstract:
We consider the problem of seeking an optimal set of model points associated to a fixed portfolio of life insurance policies. Such an optimal set is characterized by minimizing a certain risk functional, which gauges the average discrepancy with the fixed portfolio in terms of the fluctuation of the interest rate term structure within a given time horizon. We prove a representation theorem which p…
▽ More
We consider the problem of seeking an optimal set of model points associated to a fixed portfolio of life insurance policies. Such an optimal set is characterized by minimizing a certain risk functional, which gauges the average discrepancy with the fixed portfolio in terms of the fluctuation of the interest rate term structure within a given time horizon. We prove a representation theorem which provides two alternative formulations of the risk functional and which may be understood in connection with the standard approaches for the portfolio immunization based on sensitivity analysis. For this purpose, a general framework concerning some techniques of stochastic integration in Banach space and Malliavin calculus is introduced. A numerical example is discussed when considering a portfolio of whole life policies.
△ Less
Submitted 22 March, 2020; v1 submitted 2 August, 2018;
originally announced August 2018.
-
Status of the HOLMES Experiment to Directly Measure the Neutrino Mass
Authors:
A. Nucciotti,
B. Alpert,
M. Balata,
D. BeckerD. Bennett,
A. Bevilacqua,
M. Biasotti,
V. Ceriale,
G. Ceruti,
D. Corsini,
M. De Gerone,
R. Dressler,
M. Faverzani,
E. Ferri,
J. Fowler,
G. Gallucci,
J. Gard,
F. Gatti,
A. Giachero,
J. Hays-Wehle,
S. Heinitz,
G. Hilton,
U. Köster,
M. Lusignoli,
J. Mates,
S. Nisi
, et al. (13 additional authors not shown)
Abstract:
The assessment of neutrino absolute mass scale is still a crucial challenge in today particle physics and cosmology. Beta or electron capture spectrum end-point study is currently the only experimental method which can provide a model independent measurement of the absolute scale of neutrino mass. HOLMES is an experiment funded by the European Research Council to directly measure the neutrino mass…
▽ More
The assessment of neutrino absolute mass scale is still a crucial challenge in today particle physics and cosmology. Beta or electron capture spectrum end-point study is currently the only experimental method which can provide a model independent measurement of the absolute scale of neutrino mass. HOLMES is an experiment funded by the European Research Council to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the electron capture decay of the artificial isotope $^{163}$Ho. In a calorimetric measurement the energy released in the decay process is entirely contained into the detector, except for the fraction taken away by the neutrino. This approach eliminates both the issues related to the use of an external source and the systematic uncertainties arising from decays on excited final states. The most suitable detectors for this type of measurement are low temperature thermal detectors, where all the energy released into an absorber is converted into a temperature increase that can be measured by a sensitive thermometer directly coupled with the absorber. This measurement was originally proposed in 1982 by A. De Rujula and M. Lusignoli, but only in the last decade the technological progress in detectors development has allowed to design a sensitive experiment. HOLMES plans to deploy a large array of low temperature microcalorimeters with implanted $^{163}$Ho nuclei. In this contribution we outline the HOLMES project with its physics reach and technical challenges, along with its status and perspectives.
△ Less
Submitted 24 July, 2018;
originally announced July 2018.
-
The CUORE cryostat
Authors:
A. D'Addabbo,
M. Biassoni,
C. Bucci,
A. Caminata,
C. Alduino,
A. Bersani,
L. Canonica,
L. Cappelli,
G. Ceruti,
N. Chott,
S. Copello,
O. Cremonesi,
J. S. Cushman,
D. D'Aguanno,
C. J. Davis,
S. Dell'Oro,
S. Di Domizio,
A. Drobizhev,
M. Faverzani,
E. Ferri,
M. A. Franceschi,
L. Gladstone,
P. Gorla,
C. Ligi,
L. Marini
, et al. (16 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is a bolometric experiment for neutrinoless double-beta decay in $^{130}$Te search, currently taking data at the underground facility of Laboratori Nazionali del Gran Sasso (LNGS). The CUORE cryostat successfully cooled down a mass of about 1 ton at $\sim$7\,mK, delivering an uniform and constant base temperature. This result marks a fu…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is a bolometric experiment for neutrinoless double-beta decay in $^{130}$Te search, currently taking data at the underground facility of Laboratori Nazionali del Gran Sasso (LNGS). The CUORE cryostat successfully cooled down a mass of about 1 ton at $\sim$7\,mK, delivering an uniform and constant base temperature. This result marks a fundamental milestone in low temperature detectors techniques, opening the path for future ton-scale bolometric experiments searching for rare events. In this paper we present the CUORE cryogenic infrastructure, briefly describing its critical subsystems.
△ Less
Submitted 30 August, 2018; v1 submitted 16 May, 2018;
originally announced May 2018.
-
Study of Rare Nuclear Processes with CUORE
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
A. Bersani,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
D. Chiesa,
N. Chott
, et al. (94 additional authors not shown)
Abstract:
TeO2 bolometers have been used for many years to search for neutrinoless double beta decay in 130-Te. CUORE, a tonne-scale TeO2 detector array, recently published the most sensitive limit on the half-life, $T_{1/2}^{0ν} > 1.5 \times 10^{25}\,$yr, which corresponds to an upper bound of $140-400$~meV on the effective Majorana mass of the neutrino. While it makes CUORE a world-leading experiment look…
▽ More
TeO2 bolometers have been used for many years to search for neutrinoless double beta decay in 130-Te. CUORE, a tonne-scale TeO2 detector array, recently published the most sensitive limit on the half-life, $T_{1/2}^{0ν} > 1.5 \times 10^{25}\,$yr, which corresponds to an upper bound of $140-400$~meV on the effective Majorana mass of the neutrino. While it makes CUORE a world-leading experiment looking for neutrinoless double beta decay, it is not the only study that CUORE will contribute to in the field of nuclear and particle physics. As already done over the years with many small-scale experiments, CUORE will investigate both rare decays (such as the two-neutrino double beta decay of 130-Te and the hypothesized electron capture in 123-Te), and rare processes (e.g., dark matter and axion interactions). This paper describes some of the achievements of past experiments that used TeO2 bolometers, and perspectives for CUORE.
△ Less
Submitted 17 January, 2018; v1 submitted 16 January, 2018;
originally announced January 2018.
-
Transformer coupling and its modelling for the flux-ramp modulation of rf-SQUIDs
Authors:
P. Carniti,
L. Cassina,
M. Faverzani,
E. Ferri,
A. Giachero,
C. Gotti,
M. Maino,
A. Nucciotti,
G. Pessina,
A. Puiu
Abstract:
Microwave frequency domain multiplexing is a suitable technique to read out a large number of detector channels using only a few connecting lines. In the HOLMES experiment this is based on inductively coupled rf-SQUIDs (Superconducting QUantum Interference Devices) fed by TES (Transition Edge Sensors). Biasing of the whole rf-SQUID chain is provided with a single transmission line by means of the…
▽ More
Microwave frequency domain multiplexing is a suitable technique to read out a large number of detector channels using only a few connecting lines. In the HOLMES experiment this is based on inductively coupled rf-SQUIDs (Superconducting QUantum Interference Devices) fed by TES (Transition Edge Sensors). Biasing of the whole rf-SQUID chain is provided with a single transmission line by means of the recently introduced flux-ramp modulation technique, a sawtooth signal which allows signal reconstruction while operating the rf-SQUIDs in open loop condition. Due to the crucial role of the sawtooth signal, it is very important that it does not suffer from ground loop disturbances and EMI. Introducing a transformer between the biasing source and the SQUIDs is very effective in suppressing disturbances. The sawtooth signal has slow and fast components, and the period can vary between a few kHz up to MHz depending on the TES signal and SQUID characteristics. A transformer able to face such a broad range of conditions must have very stringent characteristics and needs to be custom designed. Our solution exploits standard commercial, and inexpensive, transformers for LAN networks used in a suitable combination. A model that allows to take care of the low as well as of the high frequency operating range has been developed.
△ Less
Submitted 27 February, 2018; v1 submitted 5 December, 2017;
originally announced December 2017.
-
Electron-phonon coupling in Ti/TiN MKIDs multilayer microresonator
Authors:
Marco Faverzani,
Peter K. Day,
Elena Ferri,
Andrea Giachero,
Benno Margesin,
Renato Mezzena,
Angelo Nucciotti,
Andrei Puiu
Abstract:
Over the last few years there has been a growing interest toward the use of superconducting microwave microresonators operated in quasi-thermal equilibrium mode, especially applied to single particle detection. Indeed, previous devices designed and tested by our group with X-ray sources in the keV range evidenced that several issues arise from the attempt of detection through athermal quasiparticl…
▽ More
Over the last few years there has been a growing interest toward the use of superconducting microwave microresonators operated in quasi-thermal equilibrium mode, especially applied to single particle detection. Indeed, previous devices designed and tested by our group with X-ray sources in the keV range evidenced that several issues arise from the attempt of detection through athermal quasiparticles produced within direct strikes of X-rays in the superconductor material of the resonator. In order to prevent issues related to quasiparticles self-recombination and to avoid exchange of athermal phonons with the substrate, our group focused on the development of thermal superconducting microresonators. In this configuration resonators composed of multilayer films of Ti/TiN sense the temperature of an absorbing material. To maximize the thermal response, low critical temperature films are preferable. By lowering the critical temperature, though, the maximum probing power bearable by the resonators decrease abruptly because of the weakening of the electron-phonon coupling. A proper compromise has to be found in order to avoid signal to noise ratio degradation. In this contribution we report the latest measurement of the electron-phonon coupling.
△ Less
Submitted 13 November, 2017;
originally announced November 2017.
-
Development of Thermal Kinetic Inductance Detectors suitable for X-ray spectroscopy
Authors:
A. Giachero,
A. Cruciani,
A. D'Addabbo,
P. K. Day,
S. Di Domizio,
M. Faverzani,
E. Ferri,
B. Margesin,
M. Martinez,
R. Mezzena,
L. Minutolo,
A. Nucciotti,
A. Puiu,
M. Vignati
Abstract:
We report on the development of Thermal Kinetic Inductance Detectors (TKIDs) suitable to perform X-ray spectroscopy measurements. The aim is to implement MKIDs sensors working in thermal quasi-equilibrium mode to detect X-ray photons as pure calorimeters. The thermal mode is a variation on the MKID classical way of operation that has generated interest in recent years. TKIDs can offer the MKIDs in…
▽ More
We report on the development of Thermal Kinetic Inductance Detectors (TKIDs) suitable to perform X-ray spectroscopy measurements. The aim is to implement MKIDs sensors working in thermal quasi-equilibrium mode to detect X-ray photons as pure calorimeters. The thermal mode is a variation on the MKID classical way of operation that has generated interest in recent years. TKIDs can offer the MKIDs inherent multiplexibility in the frequency domain, a high spatial resolution comparable with CCDs, and an energy resolution theoretically limited only by thermodynamic fluctuations across the thermal weak links. Microresonators are built in Ti/TiN multilayer technology with the inductive part thermally coupled with a metal absorber on a suspended SiN membrane, to avoid escape of phonons from the film to the substrate. The mid-term goal is to optimize the single pixel design in term of superconducting critical temperatures, internal quality factors, kinetic inductance and spectral energy resolution. The final goal is to realize a demonstrator array for a next generation thousand pixels X-ray spectrometer. In this contribution, the status of the project after one year of developments is reported, with detailed reference to the microresonators design and simulations and to the fabrication process.
△ Less
Submitted 30 October, 2017;
originally announced October 2017.