-
First results of AUP Nb3Sn quadrupole horizontal tests
Authors:
M. Baldini,
G. Ambrosio,
G. Apollinari,
J. Blowers,
R. Bossert,
R. Carcagno,
G. Chlachidze,
J. DiMarco,
S. Feher,
S. Krave,
V. Lombardo,
L. Martin,
C. Narug,
T. H. Nicol,
V. Nikolic,
A. Nobrega,
V. Marinozzi,
C. Orozco,
T. Page,
S. Stoynev,
T. Strauss,
M. Turenne,
D. Turrioni,
A. Vouris,
M. Yu
, et al. (26 additional authors not shown)
Abstract:
The Large Hadron Collider will soon undergo an upgrade to increase its luminosity by a factor of ~10 [1]. A crucial part of this upgrade will be replacement of the NbTi focusing magnets with Nb3Sn magnets that achieve a ~50% increase in the field strength. This will be the first ever large-scale implementation of Nb3Sn magnets in a particle accelerator. The High-Luminosity LHC Upgrade, HL-LHC is a…
▽ More
The Large Hadron Collider will soon undergo an upgrade to increase its luminosity by a factor of ~10 [1]. A crucial part of this upgrade will be replacement of the NbTi focusing magnets with Nb3Sn magnets that achieve a ~50% increase in the field strength. This will be the first ever large-scale implementation of Nb3Sn magnets in a particle accelerator. The High-Luminosity LHC Upgrade, HL-LHC is a CERN project with a world-wide collaboration. It is under construction and utilizes Nb3Sn Magnets (named MQXF) as key ingredients to increase tenfold the integrated luminosity delivered to the CMS and ATLAS experiments in the next decade.
The HL-LHC AUP is the US effort to contribute approximately 50% of the low-beta focusing magnets and crab cavities for the HL-LHC.
This paper will present the program to fabricate the Nb3Sn superconducting magnets. We are reporting the status of the HL-LHC AUP project present the results from horizontal tests of the first fully assembled cryo-assembly.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
Effect of CLIQ on training of HL-LHC quadrupole magnets
Authors:
S. Stoynev,
G. Ambrosio,
K. Amm,
J. DiMarco,
S. Feher,
P. Ferracin,
V. Marinozzi,
S. Prestemon,
A. B. Yahia
Abstract:
The high-luminosity LHC upgrade requires stronger than LHC low-beta quadrupole magnets to reach the luminosity goals of the project. The project is well advanced and HL-LHC quadrupole magnets are currently being commissioned in US Labs (MQXFA magnets) and CERN (MQXFB magnets). Those are the first Nb3Sn magnets to be used in any large particle accelerator. At development stages, many Nb3Sn accelera…
▽ More
The high-luminosity LHC upgrade requires stronger than LHC low-beta quadrupole magnets to reach the luminosity goals of the project. The project is well advanced and HL-LHC quadrupole magnets are currently being commissioned in US Labs (MQXFA magnets) and CERN (MQXFB magnets). Those are the first Nb3Sn magnets to be used in any large particle accelerator. At development stages, many Nb3Sn accelerator sub-scale models showed relatively slow training and MQXFA magnets were projected to have low tens of quenches before reaching operational field. Recently it was shown that dedicated capacitor-based devices can affect Nb3Sn magnet training, and it was suggested that CLIQ, a capacitor-based device intended for quench protection, can do too. The present paper investigates effects on training likely induced by CLIQ, using the base fact that only half the coils in a quadrupole experience upward current modulation at quench because of capacitor discharge. The study encompasses all MQXFA production magnets trained at BNL to date. No other high-statistics data from identical magnets (series) with CLIQ protection exist so far. Implications and opportunities stemming from data analysis are discussed and conclusions drawn.
△ Less
Submitted 7 February, 2024; v1 submitted 5 February, 2024;
originally announced February 2024.
-
20 T Dipole Magnet Based on Hybrid HTS/LTS Cos-Theta Coils with Stress Management
Authors:
A. V. Zlobin,
I. Noviski,
E. Barzi,
P. Ferracin
Abstract:
This paper presents the design concept of the dipole magnet with 50 mm aperture, 20 T nominal field and 13% margin based on a six-layer cos-theta (CT) hybrid coil design. Due to the high stresses and strains in the coil at high field, Stress Management (SM) elements are implemented in the CT coil geometry. The results of magnet magnetic analysis are presented and discussed. The key parameters of t…
▽ More
This paper presents the design concept of the dipole magnet with 50 mm aperture, 20 T nominal field and 13% margin based on a six-layer cos-theta (CT) hybrid coil design. Due to the high stresses and strains in the coil at high field, Stress Management (SM) elements are implemented in the CT coil geometry. The results of magnet magnetic analysis are presented and discussed. The key parameters of this design are compared with the parameters of similar magnets based on block-type and canted cos-theta coils.
△ Less
Submitted 11 May, 2023;
originally announced May 2023.
-
Analysis of the mechanical performance of the 4.2 m long MQXFA magnets for the Hi-Lumi LHC Upgrade
Authors:
L. Garcia Fajardo,
G. Ambrosio,
A. Ben Yahia,
D. W. Cheng,
P. Ferracin,
J. Ferradas Troitino,
S. Izquierdo Bermudez,
J. Muratore,
S. Prestemon,
K. L. Ray,
M. Solis,
G. Vallone
Abstract:
Under the U.S. High Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP), the 150 mm bore, high-field Nb3Sn low-\b{eta} MQXFA quadrupole magnets are being fabricated, assembled and tested, in the context of the CERN Hi-Luminosity LHC (HL-LHC) upgrade. These magnets have 4.2 m magnetic length and 4.56 m long iron yoke. To date, eight MQXFA magnets have been tested. One of the magnets additionall…
▽ More
Under the U.S. High Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP), the 150 mm bore, high-field Nb3Sn low-\b{eta} MQXFA quadrupole magnets are being fabricated, assembled and tested, in the context of the CERN Hi-Luminosity LHC (HL-LHC) upgrade. These magnets have 4.2 m magnetic length and 4.56 m long iron yoke. To date, eight MQXFA magnets have been tested. One of the magnets additionally underwent a successful endurance test with 40 triggered quenches, and two magnets did not perform as expected. This work summarizes for the first time the available strain gauge data from eight identical Nb3Sn MQXFA tested magnets, focusing on the endurance test, and on a possible cause of underperformance of the two magnets that did not pass the vertical test. We applied methods to prevent this from happening in future MQXFA magnets, which shown to be effective for last two tested magnets.
△ Less
Submitted 29 March, 2023;
originally announced March 2023.
-
Conceptual design of 20 T hybrid accelerator dipole magnets
Authors:
P. Ferracin,
G. Ambrosio,
M. Anerella,
D. Arbelaez,
L. Brouwer,
E. Barzi,
L. Cooley,
J. Cozzolino,
L. Garcia Fajardo,
R. Gupta,
M. Juchno,
V. V. Kashikhin,
F. Kurian,
V. Marinozzi,
I. Novitski,
E. Rochepault,
J. Stern,
G. Vallone,
B. Yahia,
A. V. Zlobin
Abstract:
Hybrid magnets are currently under consideration as an economically viable option towards 20 T dipole magnets for next generation of particle accelerators. In these magnets, High Temperature Superconducting (HTS) materials are used in the high field part of the coil with so-called insert coils, and Low Temperature Superconductors (LTS) like Nb3Sn and Nb-Ti superconductors are used in the lower fie…
▽ More
Hybrid magnets are currently under consideration as an economically viable option towards 20 T dipole magnets for next generation of particle accelerators. In these magnets, High Temperature Superconducting (HTS) materials are used in the high field part of the coil with so-called insert coils, and Low Temperature Superconductors (LTS) like Nb3Sn and Nb-Ti superconductors are used in the lower field region with so-called outsert coils. The attractiveness of the hybrid option lays on the fact that, on the one hand, the 20 T field level is beyond the Nb3Sn practical limits of 15-16 T for accelerator magnets and can be achieved only via HTS materials; on the other hand, the high cost of HTS superconductors compared to LTS superconductors makes it advantageous exploring a hybrid approach, where the HTS portion of the coil is minimized. We present in this paper an overview of different design options aimed at generating 20 T field in a 50 mm clear aperture. The coil layouts investigated include the Cos-theta design (CT), with its variations to reduce the conductor peak stress, namely the Canted Cos-theta design (CCT) and the Stress Management Cos-theta design (SMCT), and, in addition, the Block-type design (BL) including a form of stress management and the Common-Coil design (CC). Results from a magnetic and mechanical analysis are discussed, with particular focus on the comparison between the different options regarding quantity of superconducting material, field quality, conductor peak stress, and quench protection.
△ Less
Submitted 9 February, 2023;
originally announced February 2023.
-
MQXFA Series Magnet Production Specification
Authors:
Paolo Ferracin,
Giorgio Ambrosio,
Giorgio Apollinari,
James Blowers,
Ruben Carcagno,
Dan Cheng,
Katherine Ray,
Soren Prestemon,
Michael Solis,
Giorgio Vallone
Abstract:
The purpose of this document is to define the specifications for the structure fabrication and assembly of MQXFA series magnets to be used by the US High-Luminosity LHC Accelerator Upgrade Project (AUP). Magnets fabricated according to these specifications are expected to allow MQXFA magnets to meet the MQXFA Functional Requirements Specification. These specifications for the fabrication of MQXFA…
▽ More
The purpose of this document is to define the specifications for the structure fabrication and assembly of MQXFA series magnets to be used by the US High-Luminosity LHC Accelerator Upgrade Project (AUP). Magnets fabricated according to these specifications are expected to allow MQXFA magnets to meet the MQXFA Functional Requirements Specification. These specifications for the fabrication of MQXFA series magnets are based on the R&D performed by the US LHC Accelerator Research Program (LARP) and the development performed by AUP, in collaboration with CERN, through fabrication and test of pre-series coils and magnets.
△ Less
Submitted 25 January, 2023;
originally announced February 2023.
-
Optimizing the use of pressurized bladders for the assembly of HL-LHC MQXFB magnets
Authors:
J. Ferradas Troitino,
G. Ambrosio,
N. Bourcey,
D. Cheng,
A. Devred,
H. Felice,
P. Ferracin,
M. Guinchard,
S. Izquierdo Bermudez,
K. Kandemir,
N. Lusa,
A. Milanese,
S. Mugnier,
J. C. Perez,
E. Todesco,
S. Triquet,
G. Vallone
Abstract:
The use of pressurized bladders for stress control of superconducting magnets was firstly proposed at Lawrence Berkeley National Laboratory (LBNL) in the early 2000s. Since then, the so-called bladders and keys procedure has become one of the reference techniques for the assembly of high-field accelerator magnets and demonstrators. Exploiting the advantages of this method is today of critical impo…
▽ More
The use of pressurized bladders for stress control of superconducting magnets was firstly proposed at Lawrence Berkeley National Laboratory (LBNL) in the early 2000s. Since then, the so-called bladders and keys procedure has become one of the reference techniques for the assembly of high-field accelerator magnets and demonstrators. Exploiting the advantages of this method is today of critical importance for Nb3Sn-based accelerator magnets, whose production requires the preservation of tight stress targets in the superconducting coils to limit the effects of the strain sensitivity and brittleness of the conductor. The present manuscript reports on the results of an experimental campaign focused on the optimization of the bladders and keys assembly process in the MQXFB quadrupoles. These 7.2 m long magnets shall be among the first Nb3Sn cryomagnets to be installed in a particle accelerator as a part of the High Luminosity upgrade of the LHC. One of the main practical implications of the bladders technique, especially important when applied to long magnets like MQXFB, is that to insert the loading keys, the opening of a certain clearance in the support structure is required. The procedure used so far for MQXF magnets involved an overstress in the coils during bladder inflation. The work presented here shows that such an overshoot can be eliminated thanks to additional bladders properly positioned in the structure. This optimized method was validated in a short model magnet and in a full-length mechanical model, becoming the new baseline for the series production at CERN. Furthermore, the results are supported by numerical predictions using Finite Element models.
△ Less
Submitted 23 January, 2023;
originally announced January 2023.
-
Challenges and Lessons Learned from fabrication, testing and analysis of eight MQXFA Low Beta Quadrupole magnets for HL-LHC
Authors:
G. Ambrosio,
K. Amm,
M. Anerella,
G. Apollinari,
G. Arnau Izquierdo,
M. Baldini,
A. Ballarino,
C. Barth,
A. Ben Yahia,
J. Blowers,
P. Borges De Sousa,
R. Bossert,
B. Bulat,
R. Carcagno,
D. W. Cheng,
G. Chlachidze,
L. Cooley,
M. Crouvizier,
A. Devred,
J. DiMarco,
S. Feher,
P. Ferracin,
J. Ferradas Troitino,
L. Garcia Fajardo,
S. Gourlay
, et al. (33 additional authors not shown)
Abstract:
By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of th…
▽ More
By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of the AUP QA plan is the testing of MQXFA magnets in a vertical cryostat at BNL. The acceptance criteria that could be tested at BNL were all met by the first four production magnets (MQXFA03-MQXFA06). Subsequently, two magnets (MQXFA07 and MQXFA08) did not meet some criteria and were disassembled. Lessons learned during the disassembly of MQXFA07 caused a revision to the assembly specifications that were used for MQXFA10 and subsequent magnets. In this paper, we present a summary of: 1) the fabrication and test data of all the MQXFA magnets; 2) the analysis of MQXFA07/A08 test results with characterization of the limiting mechanism; 3) the outcome of the investigation, including the lessons learned during MQXFA07 disassembly; and 4) the finite element analysis correlating observations with test performance.
△ Less
Submitted 23 January, 2023;
originally announced January 2023.
-
Uni-layer magnets: a new concept for LTS and HTS based superconducting magnets
Authors:
José Luis Rudeiros Fernández,
Paolo Ferracin
Abstract:
A novel geometrical configuration to form a magnetic field perpendicular to an aperture, created by an asymmetric current distribution, within a single layer, and using a continuous ideal current line, named the uni-layer magnet, is here presented. The idea is compared to existing concepts in superconducting magnets, namely, the $\cosθ$ sector magnet, stress managed $\cosθ$ and canted $\cosθ$. The…
▽ More
A novel geometrical configuration to form a magnetic field perpendicular to an aperture, created by an asymmetric current distribution, within a single layer, and using a continuous ideal current line, named the uni-layer magnet, is here presented. The idea is compared to existing concepts in superconducting magnets, namely, the $\cosθ$ sector magnet, stress managed $\cosθ$ and canted $\cosθ$. The uni-layer magnet allows for a design with a continuous unit length (no layer jump), and an increased minimum bending radius of the conductor in relation to traditional $\cosθ$ and canted $\cosθ$ designs. The specific characteristics of the uni-layer design are especially advantageous for strain-sensitive and prone to winding degradation high-temperature superconductors, in very high field accelerator magnet applications, in which, high efficiency in the use of conductor, and a small aperture are required. The advantages with regard to the design and fabrication of uni-layer magnets in relation to other concepts are also discussed.
△ Less
Submitted 15 December, 2022;
originally announced December 2022.
-
A Metallurgical Inspection Method to Assess the Damage in Performance-Limiting Nb3Sn Accelerator Magnet Coils
Authors:
Alice Moros,
Mickael Denis Crouvizier,
Ignacio Aviles Santillana,
Stefano Sgobba,
Susana Izquierdo Bermudez,
Nicholas Lusa,
Jose Ferradas Troitino,
Attilio Milanese,
Ezio Todesco,
Arnaud Devred,
Giorgio Ambrosio,
Maria Baldini,
Paolo Ferracin,
Jesse Schmalzle,
Giorgio Vallone
Abstract:
The design and production of Nb3Sn-based dipole and quadrupole magnets is critical for the realization of the High-Luminosity Large Hadron Collider (HL-LHC) at the European Organization for Nuclear Research (CERN). Nb3Sn superconducting coils are aimed at enhancing the bending and focusing strengths of accelerator magnets for HL-LHC and beyond. Due to the brittle nature of Nb3Sn, the coil fabricat…
▽ More
The design and production of Nb3Sn-based dipole and quadrupole magnets is critical for the realization of the High-Luminosity Large Hadron Collider (HL-LHC) at the European Organization for Nuclear Research (CERN). Nb3Sn superconducting coils are aimed at enhancing the bending and focusing strengths of accelerator magnets for HL-LHC and beyond. Due to the brittle nature of Nb3Sn, the coil fabrication steps are very challenging and require very careful QA/QC. Flaws in the Nb3Sn filaments may lead to quenches, and eventually, performance limitation below nominal during magnet testing. A novel inspection method, including advanced non-destructive and destructive techniques, was developed to explore the root-causes of quenches occurring in performance-limiting coils. The most relevant results obtained for MQXF coils through this innovative inspection method are presented. This approach allows for precise assessment of the physical events associated to the quenches experienced b y magnet coils, mainly occurring under the form of damaged strands with transversely broken sub-elements. Coil-slice preparation, micro-optical observations of transverse and longitudinal cross-sections, and a deep etching technique of copper will be illustrated in the present work, with a focus on the results achieved for a CERN coil from a non-conforming quadrupole magnet prototype, and two coils fabricated in the US, in the framework of the Accelerator Upgrade Project (AUP) collaboration, from two different non-conforming quadrupole magnets, respectively. The results obtained through the proposed inspection method will be illustrated.
△ Less
Submitted 17 November, 2022;
originally announced November 2022.
-
Towards 20 T Hybrid Accelerator Dipole Magnets
Authors:
P. Ferracin,
G. Ambrosio,
D. Arbelaez,
L. Brouwer,
E. Barzi,
L. Cooley,
L. Garcia Fajardo,
R. Gupta,
M. Juchno,
V. Kashikhin,
V. Marinozzi,
I. Novitski,
E. Rochepault,
J. Stern,
A. Zlobin,
N. Zucchi
Abstract:
The most effective way to achieve very high collision energies in a circular particle accelerator is to maximize the field strength of the main bending dipoles. In dipole magnets using Nb-Ti superconductor the practical field limit is considered to be 8-9 T. When Nb3Sn superconductor material is utilized, a field level of 15-16 T can be achieved. To further push the magnetic field beyond the Nb3Sn…
▽ More
The most effective way to achieve very high collision energies in a circular particle accelerator is to maximize the field strength of the main bending dipoles. In dipole magnets using Nb-Ti superconductor the practical field limit is considered to be 8-9 T. When Nb3Sn superconductor material is utilized, a field level of 15-16 T can be achieved. To further push the magnetic field beyond the Nb3Sn limits, High Temperature Superconductors (HTS) need to be considered in the magnet design. The most promising HTS materials for particle accelerator magnets are Bi2212 and REBCO. However, their outstanding performance comes with a significantly higher cost. Therefore, an economically viable option towards 20 T dipole magnets could consist in an hybrid solution, where both HTS and Nb3Sn materials are used. We discuss in this paper preliminary conceptual designs of various 20 T hybrid magnet concepts. After the definition of the overall design criteria, the coil dimensions and parameters are investigated with finite element models based on simple sector coils. Preliminary 2D cross-section computation results are then presented and three main layouts compared: cos-theta, block, and common-coil. Both traditional designs and more advanced stress-management options are considered.
△ Less
Submitted 30 August, 2022;
originally announced August 2022.
-
Performance of a MQXF Nb3Sn Quadrupole Magnet Under Different Stress Level
Authors:
Susana Izquierdo Bermudez,
Giorgio Ambrosio,
Bernardo Bordini,
Nicolas Bourcey,
Paolo Ferracin,
Jose Ferradas Troitino,
Salvador Ferradas Troitino,
Lucio Fiscarelli,
Jerome Fleiter,
Michael Guinchard,
Franco Mangiarotti,
Juan Carlos Perez,
Eelis Takala,
Ezio Todesco
Abstract:
In a dipole or in a quadrupole accelerator magnet, the displacement of the coil turns induced by the electromagnetic forces can cause quenches limiting the magnet performance. For this reason, an azimuthal preload is applied to avoid azimuthal movements of the coil up to the required operational current. However, several tests showed that accelerator magnets can operate with a partial preload, i.e…
▽ More
In a dipole or in a quadrupole accelerator magnet, the displacement of the coil turns induced by the electromagnetic forces can cause quenches limiting the magnet performance. For this reason, an azimuthal preload is applied to avoid azimuthal movements of the coil up to the required operational current. However, several tests showed that accelerator magnets can operate with a partial preload, i.e. that coil unloading during the ramp does not prevent reaching higher currents. This issue is particularly relevant for Nb3Sn magnets, where the loads applied to the Nb3Sn filaments can reach the degradation limits of critical current. In order to investigate the impact of coil preload on the quench performance, the MQXFS6 short model quadrupole for the High Luminosity Upgrade was tested under an azimuthal preload at 80% of the short sample current, reaching 93% of short sample current at 1.9 K. The preload was then released to 60%, still showing ability to operate in the range of 80-85% of short sample current as required by HL-LHC project. With this lower preload, the ability of going above 90% of short sample was lost, and a significant training appeared above 85%. When the preload was restored to the original 80% value, the magnet reached with few quenches 95% of short sample (13.4 T peak field). Magnetic measurements confirm the larger movement of the coil in the case with lower preload, and agree with finite element simulations.
△ Less
Submitted 25 April, 2022;
originally announced April 2022.
-
A Strategic Approach to Advance Magnet Technology for Next Generation Colliders
Authors:
G. Ambrosio,
K. Amm,
M. Anerella,
G. Apollinari,
D. Arbelaez,
B. Auchmann,
S. Balachandran,
M. Baldini,
A. Ballarino,
S. Barua,
E. Barzi,
A. Baskys,
C. Bird,
J. Boerme,
E. Bosque,
L. Brouwer,
S. Caspi,
N. Cheggour,
G. Chlachidze,
L. Cooley,
D. Davis,
D. Dietderich,
J. DiMarco,
L. English,
L. Garcia Fajardo
, et al. (52 additional authors not shown)
Abstract:
Colliders are built on a foundation of superconducting magnet technology that provides strong dipole magnets to maintain the beam orbit and strong focusing magnets to enable the extraordinary luminosity required to probe physics at the energy frontier. The dipole magnet strength plays a critical role in dictating the energy reach of a collider, and the superconducting magnets are arguably the domi…
▽ More
Colliders are built on a foundation of superconducting magnet technology that provides strong dipole magnets to maintain the beam orbit and strong focusing magnets to enable the extraordinary luminosity required to probe physics at the energy frontier. The dipole magnet strength plays a critical role in dictating the energy reach of a collider, and the superconducting magnets are arguably the dominant cost driver for future collider facilities. As the community considers opportunities to explore new energy frontiers, the importance of advanced magnet technology - both in terms of magnet performance and in the magnet technology's potential for cost reduction - is evident, as the technology status is essential for informed decisions on targets for physics reach and facility feasibility.
△ Less
Submitted 26 March, 2022;
originally announced March 2022.
-
Common Coil Dipole for High Field Magnet Design and R&D
Authors:
Ramesh Gupta,
Kathleen Amm,
Julien Avronsart,
Michael Anerella,
Anis Ben Yahia,
John Cozzolino,
Piyush Joshi,
Mithlesh Kumar,
Febin Kurian,
Chris Runyan,
William Sampson,
Jesse Schmalzle,
Stephan Kahn,
Ronald Scanlan,
Robert Weggel,
Erich Willen,
Qing** Xu,
Javier Munilla,
Fernando Toral,
Paolo Ferracin,
Steve Gourlay,
GianLuca Sabbi,
Xiaorong Wang,
Danko van der Laan,
Jeremy Weiss
Abstract:
The common coil geometry provides an alternate design to the conventional cosine theta dipoles. It allows a wider range of conductor and magnet technologies. It also facilitates a low-cost, rapid-turn-around design and R&D program. Recent studies carried out as a part of the US Magnet Development Program revealed that at high fields (20 T with 15% operating margin or more), the common coil design…
▽ More
The common coil geometry provides an alternate design to the conventional cosine theta dipoles. It allows a wider range of conductor and magnet technologies. It also facilitates a low-cost, rapid-turn-around design and R&D program. Recent studies carried out as a part of the US Magnet Development Program revealed that at high fields (20 T with 15% operating margin or more), the common coil design also uses significantly less conductor (particularly much less HTS), as compared to that in the other designs.
△ Less
Submitted 16 March, 2022;
originally announced March 2022.
-
REBCO -- a silver bullet for our next high-field magnet and collider budget?
Authors:
Xiaorong Wang,
Anis Ben Yahia,
Ernesto Bosque,
Paolo Ferracin,
Stephen Gourlay,
Ramesh Gupta,
Hugh Higley,
Vadim Kashikhin,
Mithlesh Kumar,
Vito Lombardo,
Maxim Marchevsky,
Reed Teyber,
Sofia Viarengo
Abstract:
High-field superconducting magnets with a dipole field of 16 T and above enable future energy-frontier circular particle colliders. Although we believe these magnets can be built, none exists today. They can also be a showstopper for future high-energy machines due to a prohibitively high price tag based on the current conductor and magnet fabrication cost. The high-temperature superconducting REB…
▽ More
High-field superconducting magnets with a dipole field of 16 T and above enable future energy-frontier circular particle colliders. Although we believe these magnets can be built, none exists today. They can also be a showstopper for future high-energy machines due to a prohibitively high price tag based on the current conductor and magnet fabrication cost. The high-temperature superconducting REBCO coated conductor can address both the technical and cost issues, a silver bullet to lay both monsters to rest. The challenges and unknowns, however, can be too arduous to make the silver bullet. We lay out a potential road forward and suggest key action items. As a contribution from the accelerator community, we attempt to clarify for our theorist and experimenter colleagues a few aspects about the future high-field superconducting magnets. We hope to stimulate an effective plan for the 2023 P5 process that can lead to a cost-effective high-field magnet technology for future colliders and the exciting physics they can steward.
△ Less
Submitted 21 March, 2022; v1 submitted 16 March, 2022;
originally announced March 2022.
-
Fiber-optic diagnostic system for future accelerator magnets
Authors:
Maria Baldini,
Giorgio Ambrosio,
Paolo Ferracin,
Piyush Joshi,
S. Krave,
Linqing Luo,
Maxim Marchevsky,
G. Vallone,
Xiaorong Wang
Abstract:
The next generation high energy physics accelerators will require magnetic fields at ~20 T. HTS coils will be an essential component of future accelerator magnets and several efforts are currently dedicated on designing 20 T HTS- LTS hybrid magnets. Among the existing challenges, there is the lack of a robust quench detection system for hybrid magnet technology. Another big challenge is represente…
▽ More
The next generation high energy physics accelerators will require magnetic fields at ~20 T. HTS coils will be an essential component of future accelerator magnets and several efforts are currently dedicated on designing 20 T HTS- LTS hybrid magnets. Among the existing challenges, there is the lack of a robust quench detection system for hybrid magnet technology. Another big challenge is represented by the high number of training quenches required by Nb3Sn magnets to reach performance level. In this framework it is important to find a tool that allow local real-time monitoring of magnet strain and temperature. In this paper, we propose the use of fiber optics sensors for diagnostic and quench detection in future accelerator superconducting magnets. Discrete and distributed fiber optic sensors have demonstrated to be a promising tool. The goal is to instrument hundreds of accelerator superconducting magnets and to move beyond the proof-of-concept level. Significant developments are still needed. Here, we are going to present the most recent results and discuss the most urgent technical developments in order to make those sensors a robust and reliable diagnostic tool for accelerator superconducting magnets over the next 10 year. We foresee that discrete fiber sensors will be a stable diagnostic probe for superconducting magnets over the next 3 to 5 years. More R&D work will be necessary for distributed fibers. The most urgent needs are the increase of sample rate and sensitivity. Close collaboration with vendors will be necessary to improve mechanical properties and fabrication processes in order to produce hundreds of meters of fiber and instrument a large number of accelerator superconducting magnets. Those R&D efforts will last up to 10 years with a founding level that spans between 5-10 M$.
△ Less
Submitted 15 March, 2022;
originally announced March 2022.
-
White Paper on Leading-Edge technology And Feasibility-directed (LEAF) Program aimed at readiness demonstration for Energy Frontier Circular Colliders by the next decade
Authors:
G. Ambrosio,
G. Apollinari,
M. Baldini,
R. Carcagno,
C. Boffo,
B. Claypool,
S. Feher,
S. Hays,
D. Hoang,
V. Kashikhin,
V. V. Kashikhin,
S. Krave,
M. Kufer,
J. Lee,
V. Lombardo,
V. Marinozzi,
F. Nobrega,
X. Peng,
H. Piekarz,
V. Shiltsev,
S. Stoynev,
T. Strauss,
N. Tran,
G. Velev,
X. Xu
, et al. (17 additional authors not shown)
Abstract:
In this White Paper for the Snowmass 2021 Process, we propose the establishment of a magnet Leading-Edge technology And Feasibility-directed Program (LEAF Program) to achieve readiness for a future collider decision on the timescale of the next decade.
The LEAF Program would rely on, and be synergetic with, generic R&D efforts presently covered - in the US - by the Magnet Development Program (MD…
▽ More
In this White Paper for the Snowmass 2021 Process, we propose the establishment of a magnet Leading-Edge technology And Feasibility-directed Program (LEAF Program) to achieve readiness for a future collider decision on the timescale of the next decade.
The LEAF Program would rely on, and be synergetic with, generic R&D efforts presently covered - in the US - by the Magnet Development Program (MDP), the Conductor Procurement and R&D (CPRD) Program and other activities in the Office of HEP supported by Early Career Awards (ECA) or Lab Directed R&D (LDRD) funds. Where possible, ties to synergetic efforts in other Offices of DOE or NSF are highlighted and suggested as wider Collaborative efforts on the National scale. International efforts are also mentioned as potential partners in the LEAF Program.
We envision the LEAF Program to concentrate on demonstrating the feasibility of magnets for muon colliders as well as next generation high energy hadron colliders, pursuing, where necessary and warranted by the nature of the application, the transition from R&D models to long models/prototypes. The LEAF Program will naturally drive accelerator-quality and experiment-interface design considerations. LEAF will also concentrate, where necessary, on cost reduction and/or industrialization steps.
△ Less
Submitted 15 March, 2022;
originally announced March 2022.
-
Development and demonstration of next generation technology for Nb_3Sn accelerator magnets with lower cost, improved performance uniformity, and higher operating point in the 12-14 T range
Authors:
Giorgio Ambrosio,
Giorgio Apollinari,
Vito Lombardo,
Stoyan Stoynev,
Mauricio Suarez,
George Velev,
Paolo Ferracin,
Soren Prestemon,
GianLuca Sabbi,
Kathleen Amm
Abstract:
The scope of the proposal outlined in this white paper is the development and demonstration of the technology needed for next generation of Nb_3Sn accelerator magnets in the 12-14 T range. The main goal is to cut magnet cold-mass cost by a factor 2 or higher with respect to the Nb_3Sn magnets produced by the US Accelerator Upgrade Project (AUP) for the High-Luminosity Large Hadron Collider (HL-LHC…
▽ More
The scope of the proposal outlined in this white paper is the development and demonstration of the technology needed for next generation of Nb_3Sn accelerator magnets in the 12-14 T range. The main goal is to cut magnet cold-mass cost by a factor 2 or higher with respect to the Nb_3Sn magnets produced by the US Accelerator Upgrade Project (AUP) for the High-Luminosity Large Hadron Collider (HL-LHC). This goal will be achieved by significant reduction of labor hours, higher operating point, and improved performance uniformity. A key factor will be automation that will be achieved through industry involvement and benefitting from the experience gained in US national laboratories through the production of the AUP magnets. This partnership will enable the development of a technology that will be easily transferable to industry for mid- and large-scale production of Nb_3Sn accelerator magnets in the 12-14 T range. This step is essential to enable next generation of colliders such as the FNAL-proposed Muon Collider, FCC and other HEP hadron colliders.
This is a Directed R&D where direction is given by the field range and industry involvement for high-automation and industry-ready technology. The plan includes ten milestones, to be achieved in 6-8 years at the cost of 5-7 $M/year.
△ Less
Submitted 8 October, 2022; v1 submitted 14 March, 2022;
originally announced March 2022.
-
MQXFA Final Design Report
Authors:
Giorgio Ambrosio,
Kathleen Amm,
Mike Anerella,
Giorgio Apollinari,
Maria Baldini,
Anis Ben Yahia,
James Blowers,
Ruben Carcagno,
Daniel Cheng,
Guram Chlachidze,
Lance Cooley,
Sandor Feher,
Paolo Ferracin,
Henry Hocker,
Susana Izquierdo Bermudez,
Piyush Joshi,
Vito Lombardo,
Vittorio Marinozzi,
Joseph Muratore,
Michael Naus,
Fred Nobrega,
Heng Pan,
Marcellus Parker,
Ian Pong,
Soren Prestemon
, et al. (7 additional authors not shown)
Abstract:
The MQXFA Quadrupole magnets will be installed in High Luminosity LHC to form the Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS). A pair of MQXFA units is assembled in a stainless steel helium vessel, including the end domes, to make the Q1 Cold Mass or the Q3 Cold Mass. The US HL LHC Accelerator Upgrade Project* is responsible for the design, man…
▽ More
The MQXFA Quadrupole magnets will be installed in High Luminosity LHC to form the Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS). A pair of MQXFA units is assembled in a stainless steel helium vessel, including the end domes, to make the Q1 Cold Mass or the Q3 Cold Mass. The US HL LHC Accelerator Upgrade Project* is responsible for the design, manufacturing and test of the Q1/Q3 Cold Masses and the complete MQXFA magnets. CERN provides the cryostat components and is responsible for integration and installation in HL LHC. The MQXFA quadrupoles have 150 mm aperture, 4.2 m magnetic length, nominal gradient of 132.2 T/m, and coil peak field of 11.3 T. They use Nb_3Sn conductor and a support structure made of segmented aluminum shells pre-loaded by using bladders and keys. This report presents the final design of the MQXFA quadrupole magnets.
*Supported by the U.S. Department of Energy, Office of Science, Office of High Energy Physics
△ Less
Submitted 13 March, 2022;
originally announced March 2022.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Insertion Magnets
Authors:
G. Ambrosio,
M. Anerella,
R. Bossert,
D. Cheng,
G. Chlachidze,
D. Dietderich,
D Duarte Ramos,
P. Fabbricatore,
S. Farinon,
H. Felice,
P. Ferracin,
P. Fessia,
J. Garcia Matos,
A. Ghosh,
P. Hagen,
S. Izquierdo Bermudez,
M. Juchno,
S. Krave,
M. Marchevsky,
T. Nakamoto,
T. Ogitsu,
J. C. Perez,
H. Prin,
J. M. Rifflet,
G. L. Sabbi
, et al. (12 additional authors not shown)
Abstract:
Chapter 3 in High-Luminosity Large Hadron Collider (HL-LHC) : Preliminary Design Report. The Large Hadron Collider (LHC) is one of the largest scientific instruments ever built. Since opening up a new energy frontier for exploration in 2010, it has gathered a global user community of about 7,000 scientists working in fundamental particle physics and the physics of hadronic matter at extreme temper…
▽ More
Chapter 3 in High-Luminosity Large Hadron Collider (HL-LHC) : Preliminary Design Report. The Large Hadron Collider (LHC) is one of the largest scientific instruments ever built. Since opening up a new energy frontier for exploration in 2010, it has gathered a global user community of about 7,000 scientists working in fundamental particle physics and the physics of hadronic matter at extreme temperature and density. To sustain and extend its discovery potential, the LHC will need a major upgrade in the 2020s. This will increase its luminosity (rate of collisions) by a factor of five beyond the original design value and the integrated luminosity (total collisions created) by a factor ten. The LHC is already a highly complex and exquisitely optimised machine so this upgrade must be carefully conceived and will require about ten years to implement. The new configuration, known as High Luminosity LHC (HL-LHC), will rely on a number of key innovations that push accelerator technology beyond its present limits. Among these are cutting-edge 11-12 tesla superconducting magnets, compact superconducting cavities for beam rotation with ultra-precise phase control, new technology and physical processes for beam collimation and 300 metre-long high-power superconducting links with negligible energy dissipation. The present document describes the technologies and components that will be used to realise the project and is intended to serve as the basis for the detailed engineering design of HL-LHC.
△ Less
Submitted 26 May, 2017;
originally announced May 2017.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Case Studies on Superconducting Magnets for Particle Accelerators
Authors:
P Ferracin
Abstract:
During the CERN Accelerator School 'Superconductivity for accelerators', the students were divided into 18 groups, and 6 different exercises (case studies), involving the design and analysis of superconducting magnets and RF cavities, were assigned. The problems covered a broad spectrum of topics, from properties of superconducting materials to operation conditions and general dimensions of compon…
▽ More
During the CERN Accelerator School 'Superconductivity for accelerators', the students were divided into 18 groups, and 6 different exercises (case studies), involving the design and analysis of superconducting magnets and RF cavities, were assigned. The problems covered a broad spectrum of topics, from properties of superconducting materials to operation conditions and general dimensions of components. The work carried out by the students turned out to be an extremely useful opportunity to review the material explained during the lectures, to become familiar with the orders of magnitude of the key parameters, and to understand and compare different design options. We provide in this paper a summary of the activities related to the case studies on superconducting magnets and present the main outcomes.
△ Less
Submitted 28 January, 2015;
originally announced January 2015.