-
Tunable VUV Frequency Comb for $^{\mathrm{229m}}$Th Nuclear Spectroscopy
Authors:
Chuankun Zhang,
Peng Li,
Jie Jiang,
Lars von der Wense,
John F. Doyle,
Martin E. Fermann,
Jun Ye
Abstract:
Laser spectroscopy of the $^{\mathrm{229m}}$Th nuclear clock transition is necessary for the future construction of a nuclear-based optical clock. Precision laser sources with broad spectral coverage in the vacuum ultraviolet are needed for this task. Here, we present a tunable vacuum-ultraviolet frequency comb based on cavity-enhanced seventh-harmonic generation. Its tunable spectrum covers the c…
▽ More
Laser spectroscopy of the $^{\mathrm{229m}}$Th nuclear clock transition is necessary for the future construction of a nuclear-based optical clock. Precision laser sources with broad spectral coverage in the vacuum ultraviolet are needed for this task. Here, we present a tunable vacuum-ultraviolet frequency comb based on cavity-enhanced seventh-harmonic generation. Its tunable spectrum covers the current uncertainty range of the $^{\mathrm{229m}}$Th nuclear clock transition.
△ Less
Submitted 24 October, 2022; v1 submitted 12 August, 2022;
originally announced August 2022.
-
Temporal self-compression and self-frequency shift of sub-microjoule pulses at 8 MHz repetition rate
Authors:
Francesco Tani,
Jacob Lampen,
Martin Butryn,
Michael H. Frosz,
Jie Jiang,
Martin Fermann,
Philip St. J. Russell
Abstract:
We combine soliton dynamics in gas-filled hollow-core photonic crystal fibers with a state-of-the-art fiber laser to realize a turn-key system producing few-fs pulses at 8 MHz repetition rate at pump energies as low as 220 nJ. Furthermore, by exploiting the soliton self-frequency shift in a second hydrogen-filled hollow-core fiber, we efficiently generate pulses as short as 22 fs, continuously tun…
▽ More
We combine soliton dynamics in gas-filled hollow-core photonic crystal fibers with a state-of-the-art fiber laser to realize a turn-key system producing few-fs pulses at 8 MHz repetition rate at pump energies as low as 220 nJ. Furthermore, by exploiting the soliton self-frequency shift in a second hydrogen-filled hollow-core fiber, we efficiently generate pulses as short as 22 fs, continuously tunable from 1100 nm to 1474 nm.
△ Less
Submitted 23 July, 2022;
originally announced July 2022.
-
Effects of a quiet point on a Kerr microresonator frequency comb
Authors:
Tomohiro Tetsumoto,
Jie Jiang,
Martin E. Fermann,
Gabriele Navickaite,
Michael Geiselmann,
Antoine Rolland
Abstract:
A quiet point, an operating point of pump-resonance detuning that minimizes frequency fluctuation due to nonlinear effects inside a resonator, has been employed for phase noise reduction of a soliton Kerr microresonator frequency comb (microcomb). Naturally, it is expected that the use of the point will also improve performances of a microcomb in terms of frequency stability and faithfulness in a…
▽ More
A quiet point, an operating point of pump-resonance detuning that minimizes frequency fluctuation due to nonlinear effects inside a resonator, has been employed for phase noise reduction of a soliton Kerr microresonator frequency comb (microcomb). Naturally, it is expected that the use of the point will also improve performances of a microcomb in terms of frequency stability and faithfulness in a phase locked loop. In this study, we experimentally investigate the effect in a microcomb with a repetition frequency of 300~GHz. We obtain a lowest fractional frequency instability at a quiet point of $1.5\times 10^{-9}$ at 1 second, which is 44 times lower than free-running instability. Phase-locking of a microcomb to a stabilized fiber comb is demonstrated to evaluate performance in a feedback loop, where in-loop-limited relative fractional frequency instability between the microcomb and the fiber comb of $6.8 \times 10^{-13}$ is obtained as an indicator of the stability limitation.
△ Less
Submitted 15 February, 2021;
originally announced February 2021.
-
300 GHz wave with attosecond-level timing noise
Authors:
Tomohiro Tetsumoto,
Tadao Nagatsuma,
Martin E. Fermann,
Gabriele Navickaite,
Michael Geiselmann,
Antoine Rolland
Abstract:
Optical frequency division (OFD) via optical frequency combs (OFC) has enabled a leap in microwave metrology leading to noise performance never explored before. Extending the method to millimeter-wave (mmW) and terahertz (THz)-wave domain is of great interest. Dissipative Kerr solitons (DKSs) in integrated photonic chips offer a unique feature of delivering OFCs with ultrahigh repetition rates fro…
▽ More
Optical frequency division (OFD) via optical frequency combs (OFC) has enabled a leap in microwave metrology leading to noise performance never explored before. Extending the method to millimeter-wave (mmW) and terahertz (THz)-wave domain is of great interest. Dissipative Kerr solitons (DKSs) in integrated photonic chips offer a unique feature of delivering OFCs with ultrahigh repetition rates from 10 GHz to 1 THz making them relevant gears to perform OFD in the mmW and THz-wave domain. We experimentally demonstrate OFD of an optically-carried 3.6 THz reference down to 300 GHz through a DKS, photodetected with an ultrafast uni-traveling-carrier photodiode (UTC-PD). A new measurement system, based on the characterization of a microwave reference phase-locked to the 300 GHz signal under test, yields attosecond-level timing noise sensitivity, leveraging conventional technical limitations. This work places DKSs as a leading technology in the mmW and THz-wave field promising breakthroughs in fundamental and civilian applications.
△ Less
Submitted 22 September, 2020;
originally announced September 2020.
-
Continuous scanning of a dissipative Kerr-microresonator soliton comb for broadband, high resolution spectroscopy
Authors:
Naoya Kuse,
Tomohiro Tetsumoto,
Gabriele Navickaite,
Michael Geiselmann,
Martin E. Fermann
Abstract:
Dissipative Kerr-microresonator soliton combs (hereafter called soliton combs) are promising to realize chip scale integration of full soliton comb systems providing high precision, broad spectral coverage and a coherent link to the micro/mm/THz domain with diverse applications coming on line all the time. However, the large soliton comb spacing hampers some applications. For example, for spectros…
▽ More
Dissipative Kerr-microresonator soliton combs (hereafter called soliton combs) are promising to realize chip scale integration of full soliton comb systems providing high precision, broad spectral coverage and a coherent link to the micro/mm/THz domain with diverse applications coming on line all the time. However, the large soliton comb spacing hampers some applications. For example, for spectroscopic applications, there are simply not enough comb lines available to sufficiently cover almost any relevant absorption features. Here, we overcome this limitation by scanning the comb mode spacing by employing PDH locking and a microheater on the microresonator, showing continuous scanning of the soliton comb modes across nearly the full FSR of the microresonator without losing soliton operation, while spectral features with a bandwidth of as small of 5 MHz are resolved. Thus, comb mode scanning allows to cover the whole comb mode spectrum of tens of THz bandwidth with only one chip-scale comb.
△ Less
Submitted 29 July, 2019;
originally announced August 2019.
-
Quantum state resolution of the C$_{60}$ fullerene
Authors:
P. Bryan Changala,
Marissa L. Weichman,
Kevin F. Lee,
Martin E. Fermann,
Jun Ye
Abstract:
The remarkable physical properties of buckminsterfullerene, C$_{60}$, have attracted intense research activity since its original discovery. Total quantum state resolved measurements of isolated C$_{60}$ molecules have been of particularly long-standing interest. However, such observations have to date been unsuccessful due to the difficulty in preparing cold, gas-phase C$_{60}$ in sufficiently hi…
▽ More
The remarkable physical properties of buckminsterfullerene, C$_{60}$, have attracted intense research activity since its original discovery. Total quantum state resolved measurements of isolated C$_{60}$ molecules have been of particularly long-standing interest. However, such observations have to date been unsuccessful due to the difficulty in preparing cold, gas-phase C$_{60}$ in sufficiently high densities. Here we report high resolution infrared absorption spectroscopy of C$_{60}$ in the 8.5 $μ$m spectral region. A combination of cryogenic buffer gas cooling and cavity-enhanced direct frequency comb spectroscopy has enabled the observation of quantum state resolved rovibrational transitions. Characteristic nuclear spin statistical intensity patterns provide striking confirmation of the indistinguishability of the sixty $^{12}$C atoms, while rovibrational fine structure encodes further details of the molecule's rare icosahedral symmetry. These observations establish new possibilities in the study and control of emergent complexity in finite-sized quantum systems such as fullerenes.
△ Less
Submitted 29 August, 2018;
originally announced August 2018.
-
Phase-stabilized 100 mW frequency comb near 10 μm
Authors:
Kana Iwakuni,
Gil Porat,
Thinh Q. Bui,
Bryce J. Bjork,
Stephen B. Schoun,
Oliver H. Heckl,
Martin E. Fermann,
Jun Ye
Abstract:
Long-wavelength mid-infrared frequency combs with high power and flexible tunability are highly desired for molecular spectroscopy, including investigation of large molecules such as C60. We present a high power, phase-stabilized frequency comb near 10 μm, generated by a synchronously-pumped, singly-resonant optical parametric oscillator (OPO) based on AgGaSe2. The OPO can be continuously tuned fr…
▽ More
Long-wavelength mid-infrared frequency combs with high power and flexible tunability are highly desired for molecular spectroscopy, including investigation of large molecules such as C60. We present a high power, phase-stabilized frequency comb near 10 μm, generated by a synchronously-pumped, singly-resonant optical parametric oscillator (OPO) based on AgGaSe2. The OPO can be continuously tuned from 8.4 to 9.5 μm, with a maximum average idler power of 100 mW at the center wavelength of 8.5 μm. Both the repetition rate (frep) and the carrier-envelop offset frequency (fceo) of the idler wave are phase-locked to microwave signals referenced to a Cs clock. We describe the detailed design and construction of the frequency comb, and discuss potential applications for precise and sensitive direct frequency comb spectroscopy.
△ Less
Submitted 1 March, 2018;
originally announced March 2018.
-
Absolute spectroscopy near 7.8 μm with a comb-locked extended-cavity quantum-cascade-laser
Authors:
Marco Lamperti,
Bidoor Alsaif,
Davide Gatti,
Martin Fermann,
Paolo Laporta,
Aamir Farooq,
Marco Marangoni
Abstract:
We report the first experimental demonstration of frequency-locking of an extended-cavity quantum-cascade-laser (EC-QCL) to a near-infrared frequency comb. The locking scheme is applied to carry out absolute spectroscopy of N2O lines near 7.87 μm with an accuracy of ~60 kHz. Thanks to a single mode operation over more than 100 cm^{-1}, the comb-locked EC-QCL shows great potential for the accurate…
▽ More
We report the first experimental demonstration of frequency-locking of an extended-cavity quantum-cascade-laser (EC-QCL) to a near-infrared frequency comb. The locking scheme is applied to carry out absolute spectroscopy of N2O lines near 7.87 μm with an accuracy of ~60 kHz. Thanks to a single mode operation over more than 100 cm^{-1}, the comb-locked EC-QCL shows great potential for the accurate retrieval of line center frequencies in a spectral region that is currently outside the reach of broadly tunable cw sources, either based on difference frequency generation or optical parametric oscillation. The approach described here can be straightforwardly extended up to 12 μm, which is the current wavelength limit for commercial cw EC-QCLs.
△ Less
Submitted 31 July, 2017;
originally announced August 2017.
-
All-polarization-maintaining, single-port Er:fiber comb for high-stability comparison of optical lattice clocks
Authors:
Noriaki Ohmae,
Naoya Kuse,
Martin E. Fermann,
Hidetoshi Katori
Abstract:
All-polarization-maintaining, single-port Er:fiber combs offer long-term robust operation as well as high stability. We have built two such combs and evaluated the transfer noise for linking optical clocks. A uniformly broadened spectrum over 135-285 THz with a high signal-to-noise ratio enables the optical frequency measurement of the subharmonics of strontium, ytterbium, and mercury optical latt…
▽ More
All-polarization-maintaining, single-port Er:fiber combs offer long-term robust operation as well as high stability. We have built two such combs and evaluated the transfer noise for linking optical clocks. A uniformly broadened spectrum over 135-285 THz with a high signal-to-noise ratio enables the optical frequency measurement of the subharmonics of strontium, ytterbium, and mercury optical lattice clocks with the fractional frequency-noise power spectral density of $(1-2)\times 10^{-17}$ Hz$^{-1/2}$ at 1 Hz. By applying a synchronous clock comparison, the comb enables clock ratio measurements with $10^{-17}$ instability at 1 s, which is one order of magnitude smaller than the best instability of the frequency ratio of optical lattice clocks.
△ Less
Submitted 1 June, 2017;
originally announced June 2017.
-
Three Photon Absorption in Optical Parametric Oscillators Based on OP-GaAs
Authors:
Oliver H. Heckl,
Bryce J. Bjork,
Georg Winkler,
P. Bryan Changala,
Ben Spaun,
1 Gil Porat,
Thinh Q. Bui,
Kevin F. Lee,
Jie Jiang,
Martin Fermann,
Peter G. Schunemann,
Jun Ye
Abstract:
We report on the first singly-resonant (SR), synchronously pumped optical parametric oscillator (OPO) based on orientation-patterned gallium arsenide (OP-GaAs). Together with a doubly resonant (DR) degenerate OPO based on the same OP-GaAs material, the output spectra cover 3 to 6 $μ$m within ~3 dB of relative power. The DR-OPO has the highest output power reported to date from a femtosecond, synch…
▽ More
We report on the first singly-resonant (SR), synchronously pumped optical parametric oscillator (OPO) based on orientation-patterned gallium arsenide (OP-GaAs). Together with a doubly resonant (DR) degenerate OPO based on the same OP-GaAs material, the output spectra cover 3 to 6 $μ$m within ~3 dB of relative power. The DR-OPO has the highest output power reported to date from a femtosecond, synchronously pumped OPO based on OP-GaAs. We discovered strong three photon absorption with a coefficient of 0.35 ${\pm}$ 0.06 cm${^3}$/GW${^2}$ for our OP-GaAs sample, which limits the output power of these OPOs as mid-IR light sources. We present a detailed study of the three photon loss on the performance of both the SR and DR-OPOs, and compare them to those without this loss mechanism.
△ Less
Submitted 2 September, 2016;
originally announced September 2016.
-
Optical frequency comb spectroscopy at 3-5.4 μm with a doubly resonant optical parametric oscillator
Authors:
Amir Khodabakhsh,
Venkata Ramaiah-Badarla,
Lucile Rutkowski,
Alexandra C. Johansson,
Kevin F. Lee,
Jie Jiang,
Christian Mohr,
Martin E. Fermann,
Aleksandra Foltynowicz
Abstract:
We present a versatile mid-infrared frequency comb spectroscopy system based on a doubly resonant optical parametric oscillator tunable in the 3-5.4 μm range and two detection methods, a Fourier transform spectrometer (FTS) and a Vernier spectrometer. Using the FTS with a multipass cell we measure high-precision broadband absorption spectra of CH$_4$ and NO at ~3.3 μm and ~5.2 μm, respectively, an…
▽ More
We present a versatile mid-infrared frequency comb spectroscopy system based on a doubly resonant optical parametric oscillator tunable in the 3-5.4 μm range and two detection methods, a Fourier transform spectrometer (FTS) and a Vernier spectrometer. Using the FTS with a multipass cell we measure high-precision broadband absorption spectra of CH$_4$ and NO at ~3.3 μm and ~5.2 μm, respectively, and of atmospheric species (CH$_4$, CO, CO$_2$ and H$_2$O) in air in the signal and idler wavelength range. The figure of merit of the system is on the order of 10$^{-8}$ cm$^{-1}$ Hz$^{-1/2}$ per spectral element, and multiline fitting yields minimum detectable concentrations of 10-20 ppb Hz$^{-1/2}$ for CH$_4$, NO and CO. For the first time in the mid-infrared, we perform continuous-filtering Vernier spectroscopy using a low finesse enhancement cavity, a grating and a single detector, and measure the absorption spectrum of CH$_4$ and H$_2$O in ambient air at ~3.3 μm.
△ Less
Submitted 31 March, 2016;
originally announced March 2016.
-
Surpassing the Path-Limited Resolution of a Fourier Transform Spectrometer with Frequency Combs
Authors:
Piotr Maslowski,
Kevin F. Lee,
Alexandra C. Johansson,
Amir Khodabakhsh,
Grzegorz Kowzan,
Lucile Rutkowski,
Andrew A. Mills,
Christian Mohr,
Jie Jiang,
Martin E. Fermann,
Aleksandra Foltynowicz
Abstract:
Fourier transform spectroscopy based on incoherent light sources is a well-established tool in research fields from molecular spectroscopy and atmospheric monitoring to material science and biophysics. It provides broadband molecular spectra and information about the molecular structure and composition of absorptive media. However, the spectral resolution is fundamentally limited by the maximum de…
▽ More
Fourier transform spectroscopy based on incoherent light sources is a well-established tool in research fields from molecular spectroscopy and atmospheric monitoring to material science and biophysics. It provides broadband molecular spectra and information about the molecular structure and composition of absorptive media. However, the spectral resolution is fundamentally limited by the maximum delay range (Δ$_{max}$) of the interferometer, so acquisition of high-resolution spectra implies long measurement times and large instrument size. We overcome this limit by combining the Fourier transform spectrometer with an optical frequency comb and measuring the intensities of individual comb lines by precisely matching the Δ$_{max}$ to the comb line spacing. This allows measurements of absorption lines narrower than the nominal (optical path-limited) resolution without ringing effects from the instrumental lineshape and reduces the acquisition time and interferometer length by orders of magnitude.
△ Less
Submitted 28 May, 2015;
originally announced May 2015.
-
Widely-tunable mid-IR frequency comb source based on difference frequency generation
Authors:
Axel Ruehl,
Alessio Gambetta,
Ingmar Hartl,
Martin E. Fermann,
Kjeld S. E. Eikema,
Marco Marangoni
Abstract:
We report on a mid-infrared frequency comb source of unprecedented tunability covering the entire 3-10 μm molecular fingerprint region. The system is based on difference frequency generation in a GaSe crystal pumped by a 151 MHz Yb:fiber frequency comb. The process was seeded with Raman shifted solitons generated in a highly nonlinear suspended-core fiber with the same source. Average powers up to…
▽ More
We report on a mid-infrared frequency comb source of unprecedented tunability covering the entire 3-10 μm molecular fingerprint region. The system is based on difference frequency generation in a GaSe crystal pumped by a 151 MHz Yb:fiber frequency comb. The process was seeded with Raman shifted solitons generated in a highly nonlinear suspended-core fiber with the same source. Average powers up to 1.5 mW were achieved at 4.7 μm wavelength.
△ Less
Submitted 12 March, 2012;
originally announced March 2012.
-
Full phase stabilization of a Yb:fiber femtosecond frequency comb via high-bandwidth transducers
Authors:
C. Benko,
A. Ruehl,
M. J. Martin,
K. S. E. Eikema,
M. E. Fermann,
I. Hartl,
J. Ye
Abstract:
We present full phase stabilization of an amplified Yb:fiber femtosecond frequency comb using an intra-cavity electro-optic modulator and an acousto-optic modulator. These transducers provide high servo bandwidths of 580 kHz and 250 kHz for frep and fceo, producing a robust and low phase noise fiber frequency comb. The comb was self-referenced with an f - 2f interferometer and phase locked to an u…
▽ More
We present full phase stabilization of an amplified Yb:fiber femtosecond frequency comb using an intra-cavity electro-optic modulator and an acousto-optic modulator. These transducers provide high servo bandwidths of 580 kHz and 250 kHz for frep and fceo, producing a robust and low phase noise fiber frequency comb. The comb was self-referenced with an f - 2f interferometer and phase locked to an ultra-stable optical reference used for the JILA Sr optical clock at 698 nm, exhibiting 0.21 rad and 0.47 rad of integrated phase errors (over 1 mHz - 1 MHz) respectively. Alternatively, the comb was locked to two optical references at 698 nm and 1064 nm, obtaining 0.43 rad and 0.14 rad of integrated phase errors respectively.
△ Less
Submitted 23 February, 2012;
originally announced February 2012.
-
Direct Frequency Comb Spectroscopy in the Extreme Ultraviolet
Authors:
Arman Cingoz,
Dylan C. Yost,
Thomas K. Allison,
Axel Ruehl,
Martin E. Fermann,
Ingmar Hartl,
Jun Ye
Abstract:
Development of the optical frequency comb has revolutionised metrology and precision spectroscopy due to its ability to provide a precise and direct link between microwave and optical frequencies. A novel application of frequency comb technology that leverages both the ultrashort duration of each laser pulse and the exquisite phase coherence of a train of pulses is the generation of frequency comb…
▽ More
Development of the optical frequency comb has revolutionised metrology and precision spectroscopy due to its ability to provide a precise and direct link between microwave and optical frequencies. A novel application of frequency comb technology that leverages both the ultrashort duration of each laser pulse and the exquisite phase coherence of a train of pulses is the generation of frequency combs in the extreme ultraviolet (XUV) via high harmonic generation (HHG) in a femtosecond enhancement cavity. Until now, this method has lacked sufficient average power for applications, which has also hampered efforts to observe phase coherence of the high-repetition rate pulse train produced in the extremely nonlinear HHG process. Hence, the existence of a frequency comb in the XUV has not been confirmed. We have overcome both challenges. Here, we present generation of >200 μW per harmonic reaching 50 nm, and the observation of single-photon spectroscopy signals for both an argon transition at 82 nm and a neon transition at 63 nm. The absolute frequency of the argon transition has been determined via direct frequency comb spectroscopy. The resolved 10-MHz linewidth of the transition, limited by the transverse temperature of the argon atoms, is unprecedented in this spectral region and places a stringent upper limit on the linewidth of individual comb teeth. Due to the lack of cw lasers, these frequency combs are currently the only promising avenue towards extending ultrahigh precision spectroscopy to below the 100-nm spectral region with a wide range of applications that include spectroscopy of electronic transitions in molecules, experimental tests of bound state and many body quantum electrodynamics in He+ and He, development of next-generation "nuclear" clocks, and searches for spatial and temporal variation of fundamental constants using the enhanced sensitivity of highly charged ions.
△ Less
Submitted 8 September, 2011;
originally announced September 2011.
-
Ultra-Broadband Coherent Supercontinuum Frequency Comb
Authors:
Axel Ruehl,
Michael. J. Martin,
Kevin C. Cossel,
Lisheng Chen,
Hugh McKay,
Brian Thomas,
Craig Benko,
Liang Dong,
John M. Dudley,
Martin E. Fermann,
Ingmar Hartl,
Jun Ye
Abstract:
We present detailed studies of the coherence properties of an ultra-broadband super-continuum, enabled by a new approach involving continuous wave laser sources to independently probe both the amplitude and phase noise quadratures across the entire spectrum. The continuum coherently spans more than 1.5 octaves, supporting Hz-level comparison of ultrastable lasers at 698 nm and 1.54 μm. We present…
▽ More
We present detailed studies of the coherence properties of an ultra-broadband super-continuum, enabled by a new approach involving continuous wave laser sources to independently probe both the amplitude and phase noise quadratures across the entire spectrum. The continuum coherently spans more than 1.5 octaves, supporting Hz-level comparison of ultrastable lasers at 698 nm and 1.54 μm. We present the first numerical simulation of the accumulated comb coherence in the limit of many pulses, in contrast to the single-pulse level, with systematic experimental verification. The experiment and numerical simulations reveal the presence of quantum-seeded broadband amplitude noise without phase coherence degradation, including the discovery of a dependence of the super-continuum coherence on the fiber fractional Raman gain.
△ Less
Submitted 10 May, 2011;
originally announced May 2011.
-
Broadband Phase-Noise Suppression in a Yb-Fiber Frequency Comb
Authors:
A. Cingoz,
D. C. Yost,
T. K. Allison,
A. Ruehl,
M. E. Fermann,
I. Hartl,
J. Ye
Abstract:
We report a simple technique to suppress high frequency phase noise of a Yb-based fiber optical frequency comb using an active intensity noise servo. Out-of-loop measurements of the phase noise using an optical heterodyne beat with a continuous wave (cw) laser show suppression of phase noise by \geq7 dB out to Fourier frequencies of 100 kHz with a unity-gain crossing of -700 kHz. These results are…
▽ More
We report a simple technique to suppress high frequency phase noise of a Yb-based fiber optical frequency comb using an active intensity noise servo. Out-of-loop measurements of the phase noise using an optical heterodyne beat with a continuous wave (cw) laser show suppression of phase noise by \geq7 dB out to Fourier frequencies of 100 kHz with a unity-gain crossing of -700 kHz. These results are enabled by the strong correlation between the intensity and phase noise of the laser. Detailed measurements of intensity and phase noise spectra, as well as transfer functions, reveal that the dominant phase and intensity noise contribution above -100 kHz is due to amplified spontaneous emission (ASE) or other quantum noise sources.
△ Less
Submitted 29 January, 2011;
originally announced January 2011.
-
Phase-stabilized, 1.5-W frequency comb at 2.8 to 4.8 micron
Authors:
Florian Adler,
Kevin C. Cossel,
Michael J. Thorpe,
Ingmar Hartl,
Martin E. Fermann,
Jun Ye
Abstract:
We present a high-power optical parametric oscillator-based frequency comb in the mid-infrared wavelength region using periodically poled lithium niobate. The system is synchronously pumped by a 10-W femtosecond Yb:fiber laser centered at 1.07 um and is singly resonant for the signal. The idler (signal) wavelength can be continuously tuned from 2.8 to 4.8 um (1.76 to 1.37 um) with a simultaneous…
▽ More
We present a high-power optical parametric oscillator-based frequency comb in the mid-infrared wavelength region using periodically poled lithium niobate. The system is synchronously pumped by a 10-W femtosecond Yb:fiber laser centered at 1.07 um and is singly resonant for the signal. The idler (signal) wavelength can be continuously tuned from 2.8 to 4.8 um (1.76 to 1.37 um) with a simultaneous bandwidth as high as 0.3 um and a maximum average idler output power of 1.50 W. We also demonstrate the performance of the stabilized comb by recording the heterodyne beat with a narrow-linewidth diode laser. This OPO is an ideal source for frequency comb spectroscopy in the mid-IR.
△ Less
Submitted 11 February, 2009;
originally announced February 2009.