-
The Upgrade of the CMS RPC System during the First LHC Long Shutdown
Authors:
M. Tytgat,
A. Marinov,
P. Verwilligen,
N. Zaganidis,
A. Aleksandrov,
V. Genchev,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Sultanov,
Y. Assran,
M. Abbrescia,
C. Calabria,
A. Colaleo,
G. Iaselli,
F. Loddo,
M. Maggi,
G. Pugliese,
L. Benussi,
S. Bianco,
M. Caponero,
S. Colafranceschi,
F. Felli,
D. Piccolo,
G. Saviano
, et al. (9 additional authors not shown)
Abstract:
The CMS muon system includes in both the barrel and endcap region Resistive Plate Chambers (RPC). They mainly serve as trigger detectors and also improve the reconstruction of muon parameters. Over the years, the instantaneous luminosity of the Large Hadron Collider gradually increases. During the LHC Phase 1 (~first 10 years of operation) an ultimate luminosity is expected above its design value…
▽ More
The CMS muon system includes in both the barrel and endcap region Resistive Plate Chambers (RPC). They mainly serve as trigger detectors and also improve the reconstruction of muon parameters. Over the years, the instantaneous luminosity of the Large Hadron Collider gradually increases. During the LHC Phase 1 (~first 10 years of operation) an ultimate luminosity is expected above its design value of 10^34/cm^2/s at 14 TeV. To prepare the machine and also the experiments for this, two long shutdown periods are scheduled for 2013-2014 and 2018-2019. The CMS Collaboration is planning several detector upgrades during these long shutdowns. In particular, the muon detection system should be able to maintain a low-pT threshold for an efficient Level-1 Muon Trigger at high particle rates. One of the measures to ensure this, is to extend the present RPC system with the addition of a 4th layer in both endcap regions. During the first long shutdown, these two new stations will be equipped in the region |eta|<1.6 with 144 High Pressure Laminate (HPL) double-gap RPCs operating in avalanche mode, with a similar design as the existing CMS endcap chambers. Here, we present the upgrade plans for the CMS RPC system for the fist long shutdown, including trigger simulation studies for the extended system, and details on the new HPL production, the chamber assembly and the quality control procedures.
△ Less
Submitted 10 September, 2012;
originally announced September 2012.
-
Study of gas purifiers for the CMS RPC detector
Authors:
L. Benussi,
S. Bianco,
S. Colafranceschi,
F. L. Fabbri,
F. Felli,
M. Ferrini,
M. Giardoni,
T. Greci,
A. Paolozzi,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
G. Saviano,
S. Buontempo,
A. Cimmino,
M. de Gruttola,
F Fabozzi d A. O. M. Iorio,
L. Lista,
P. Paolucci,
P. Baesso,
G. Belli,
D. Pagano,
S. P. Ratti,
A. Vicini
, et al. (4 additional authors not shown)
Abstract:
The CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has been carried out over 400 days between July 2008 and August 2009 at CERN in a low-radiation test area, with the use of RPC chambers with currents monitoring, and gas analysis sampling points. The study aimed to fully clar…
▽ More
The CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has been carried out over 400 days between July 2008 and August 2009 at CERN in a low-radiation test area, with the use of RPC chambers with currents monitoring, and gas analysis sampling points. The study aimed to fully clarify the presence of pollutants, the chemistry of purifiers used in the CL, and the regeneration procedure. Preliminary results on contaminants release and purifier characterization are reported.
△ Less
Submitted 26 December, 2010;
originally announced December 2010.
-
Gas Analysis and Monitoring Systems for the RPC Detector of CMS at LHC
Authors:
M. Abbrescia,
A. Colaleo,
R. Guida,
G. Iaselli,
R. Liuzzi,
F. Loddo,
M. Maggi,
B. Marangelli,
S. Natali,
S. Nuzzo,
G. Pugliese,
A. Ranieri,
F. Romano,
R. Trentadue,
L. Benussi,
M. Bertani,
S. Bianco,
M. A. Caponero,
D. Colonna,
D. Donisi,
F. L. Fabbri,
F. Felli,
M. Giardoni B. Ortenzi,
M. Pallotta,
A. Paolozzi
, et al. (16 additional authors not shown)
Abstract:
The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC proton collider (CERN, Switzerland) will employ an online gas analysis and monitoring system of the freon-based gas mixture used. We give an overview of the CMS RPC gas system, describe the project parameters and first results on gas-chromatograph analysis. Finally, we report on preliminary results for a set of monitor…
▽ More
The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC proton collider (CERN, Switzerland) will employ an online gas analysis and monitoring system of the freon-based gas mixture used. We give an overview of the CMS RPC gas system, describe the project parameters and first results on gas-chromatograph analysis. Finally, we report on preliminary results for a set of monitor RPC.
△ Less
Submitted 30 December, 2006;
originally announced January 2007.
-
A Novel Approach for an Integrated Straw tube-Microstrip Detector
Authors:
E. Basile,
F. Bellucci,
L. Benussi,
M. Bertani,
S. Bianco,
M. A. Caponero,
D. Colonna,
F. Di Falco,
F. L. Fabbri,
F. Felli,
M. Giardoni,
A. La Monaca,
G. Mensitieri,
B. Ortenzi,
M. Pallotta,
A. Paolozzi,
L. Passamonti,
D. Pierluigi,
C. Pucci,
A. Russo,
G. Saviano,
F. Massa,
F. Casali,
M. Bettuzzi,
D. Bianconi F. Baruffaldi
, et al. (1 additional authors not shown)
Abstract:
We report on a novel concept of silicon microstrips and straw tubes detector, where integration is accomplished by a straw module with straws not subjected to mechanical tension in a Rohacell $^{\circledR}$ lattice and carbon fiber reinforced plastic shell. Results on mechanical and test beam performances are reported on as well.
We report on a novel concept of silicon microstrips and straw tubes detector, where integration is accomplished by a straw module with straws not subjected to mechanical tension in a Rohacell $^{\circledR}$ lattice and carbon fiber reinforced plastic shell. Results on mechanical and test beam performances are reported on as well.
△ Less
Submitted 28 December, 2005;
originally announced December 2005.
-
Two- and Three-Dimensional Reconstruction and Analysis of the Straw Tubes Tomography in the Btev Experiment
Authors:
E. Basile,
F. Bellucci,
L. Benussi,
M. Bertani,
S. Bianco,
M. A. Caponero,
D. Colonna,
F. Di Falco,
F. L. Fabbri,
F. Felli,
M. Giardoni,
A. La Monaca,
F. Massa,
G. Mensitieri,
B. Ortenzi,
M. Pallotta,
A. Paolozzi,
L. Passamonti,
D. Pierluigi,
C. Pucci,
A. Russo,
G. Saviano F. Casali,
M. Bettuzzi,
D. Bianconi
Abstract:
A check of the eccentricity of the aluminised kapton straw tubes used in the BTeV experiment is accomplished using X-ray tomography of the section of tubes modules. 2 and 3-dimensional images of the single tubes and of the modules are reconstructed and analysed. Preliminary results show that a precision better than 40 $μ$m can be reached on the measurement of the straw radii.
A check of the eccentricity of the aluminised kapton straw tubes used in the BTeV experiment is accomplished using X-ray tomography of the section of tubes modules. 2 and 3-dimensional images of the single tubes and of the modules are reconstructed and analysed. Preliminary results show that a precision better than 40 $μ$m can be reached on the measurement of the straw radii.
△ Less
Submitted 28 December, 2005;
originally announced December 2005.
-
Micrometric Position Monitoring Using Fiber Bragg Grating Sensors in Silicon Detectors
Authors:
E. Basile,
F. Bellucci,
L. Benussi,
M. Bertani,
S. Bianco,
M. A. Caponero,
D. Colonna,
F. Di Falco,
F. L. Fabbri,
F. Felli,
M. Giardoni,
A. La Monaca,
F. Massa,
G. Mensitieri,
B. Ortenzi,
M. Pallotta,
A. Paolozzi,
L. Passamonti,
D. Pierluigi,
C. Pucci,
A. Russo,
G. Saviano
Abstract:
We show R&D results including long term stability, resolution, radiation hardness and characterization of Fiber Grating sensors used to monitor structure deformation, repositioning and surveying of silicon detector in High Energy Physics.
We show R&D results including long term stability, resolution, radiation hardness and characterization of Fiber Grating sensors used to monitor structure deformation, repositioning and surveying of silicon detector in High Energy Physics.
△ Less
Submitted 28 December, 2005;
originally announced December 2005.
-
An Uncoventional Approach for a Straw Tube-Microstrip Detector
Authors:
E. Basile,
F. Bellucci,
L. Benussi,
M. Bertani,
S. Bianco,
M. A. Caponero,
D. Colonna,
F. Di Falco,
F. L. Fabbri,
F. Felli,
M. Giardoni,
A. La Monaca,
G. Mensitieri,
B. Ortenzi,
M. Pallotta,
A. Paolozzi,
L. Passamonti,
D. Pierluigi,
C. Pucci,
A. Russo,
G. Saviano,
S. Tomassini
Abstract:
We report on a novel concept of silicon microstrips and straw tubes detector, where integration is accomplished by a straw module with straws not subjected to mechanical tension in a Rohacell lattice and carbon fiber reinforced plastic shell. Results on mechanical and test beam performances are reported on as well.
We report on a novel concept of silicon microstrips and straw tubes detector, where integration is accomplished by a straw module with straws not subjected to mechanical tension in a Rohacell lattice and carbon fiber reinforced plastic shell. Results on mechanical and test beam performances are reported on as well.
△ Less
Submitted 16 December, 2004;
originally announced December 2004.