-
The Cryogenic Storage Ring CSR
Authors:
Robert von Hahn,
Arno Becker,
Felix Berg,
Klaus Blaum,
Christian Breitenfeldt,
Hisham Fadil,
Florian Fellenberger,
Michael Froese,
Sebastian George,
Jürgen Göck,
Manfred Grieser,
Florian Grussie,
Elisabeth A. Guerin,
Oded Heber,
Philipp Herwig,
Jonas Karthein,
Claude Krantz,
Holger Kreckel,
Michael Lange,
Felix Laux,
Svenja Lohmann,
Sebastian Menk,
Christian Meyer,
Preeti M. Mishra,
Oldřich Novotný
, et al. (19 additional authors not shown)
Abstract:
An electrostatic cryogenic storage ring, CSR, for beams of anions and cations with up to 300 keV kinetic energy per unit charge has been designed, constructed and put into operation. With a circumference of 35 m, the ion-beam vacuum chambers and all beam optics are in a cryostat and cooled by a closed-cycle liquid helium system. At temperatures as low as (5.5 $\pm$ 1) K inside the ring, storage ti…
▽ More
An electrostatic cryogenic storage ring, CSR, for beams of anions and cations with up to 300 keV kinetic energy per unit charge has been designed, constructed and put into operation. With a circumference of 35 m, the ion-beam vacuum chambers and all beam optics are in a cryostat and cooled by a closed-cycle liquid helium system. At temperatures as low as (5.5 $\pm$ 1) K inside the ring, storage time constants of several minutes up to almost an hour were observed for atomic and molecular, anion and cation beams at an energy of 60 keV. The ion-beam intensity, energy-dependent closed-orbit shifts (dispersion) and the focusing properties of the machine were studied by a system of capacitive pickups. The Schottky-noise spectrum of the stored ions revealed a broadening of the momentum distribution on a time scale of 1000 s. Photodetachment of stored anions was used in the beam lifetime measurements. The detachment rate by anion collisions with residual-gas molecules was found to be extremely low. A residual-gas density below 140 cm$^{-3}$ is derived, equivalent to a room-temperature pressure below 10$^{-14}$ mbar. Fast atomic, molecular and cluster ion beams stored for long periods of time in a cryogenic environment will allow experiments on collision- and radiation-induced fragmentation processes of ions in known internal quantum states with merged and crossed photon and particle beams.
△ Less
Submitted 5 June, 2016;
originally announced June 2016.
-
An Efficient, Movable Single-Particle Detector for Use in Cryogenic Ultra-High Vacuum Environments
Authors:
Kaija Spruck,
Arno Becker,
Florian Fellenberger,
Manfred Grieser,
Robert von Hahn,
Vincent Klinkhamer,
Oldřich Novotný,
Stefan Schippers,
Stephen Vogel,
Andreas Wolf,
Claude Krantz
Abstract:
A compact, highly efficient single-particle counting detector for ions of keV/u kinetic energy, movable by a long-stroke mechanical translation stage, has been developed at the Max-Planck-Institut für Kernphysik (Max Planck Institute for Nuclear Physics, MPIK). Both, detector and translation mechanics, can operate at ambient temperatures down to $\sim$ 10 K and consist fully of ultra-high vacuum (…
▽ More
A compact, highly efficient single-particle counting detector for ions of keV/u kinetic energy, movable by a long-stroke mechanical translation stage, has been developed at the Max-Planck-Institut für Kernphysik (Max Planck Institute for Nuclear Physics, MPIK). Both, detector and translation mechanics, can operate at ambient temperatures down to $\sim$ 10 K and consist fully of ultra-high vacuum (UHV) compatible, high-temperature bakeable and non-magnetic materials. The set-up is designed to meet the technical demands of MPIK's Cryogenic Storage Ring (CSR). We present a series of functional tests that demonstrate full suitability for this application and characterise the set-up with regard to its particle detection efficiency.
△ Less
Submitted 16 July, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
Measurement of the neutron electric to magnetic form factor ratio at Q2 = 1.58 GeV2 using the reaction 3He(e,e'n)pp
Authors:
B. S. Schlimme,
P. Achenbach,
C. A. Ayerbe Gayoso,
J. C. Bernauer,
R. Böhm,
D. Bosnar,
Th. Challand,
M. O. Distler,
L. Doria,
F. Fellenberger,
H. Fonvieille,
M. Gómez Rodríguez,
P. Grabmayr,
T. Hehl,
W. Heil,
D. Kiselev,
J. Krimmer,
M. Makek,
H. Merkel,
D. G. Middleton,
U. Müller,
L. Nungesser,
B. A. Ott,
J. Pochodzalla,
M. Potokar
, et al. (7 additional authors not shown)
Abstract:
A measurement of beam helicity asymmetries in the reaction 3He(e,e'n)pp has been performed at the Mainz Microtron in quasielastic kinematics in order to determine the electric to magnetic form factor ratio of the neutron, GEn/GMn, at a four momentum transfer Q2 = 1.58 GeV2. Longitudinally polarized electrons were scattered on a highly polarized 3He gas target. The scattered electrons were detected…
▽ More
A measurement of beam helicity asymmetries in the reaction 3He(e,e'n)pp has been performed at the Mainz Microtron in quasielastic kinematics in order to determine the electric to magnetic form factor ratio of the neutron, GEn/GMn, at a four momentum transfer Q2 = 1.58 GeV2. Longitudinally polarized electrons were scattered on a highly polarized 3He gas target. The scattered electrons were detected with a high-resolution magnetic spectrometer, and the ejected neutrons with a dedicated neutron detector composed of scintillator bars. To reduce systematic errors data were taken for four different target polarization orientations allowing the determination of GEn/GMn from a double ratio. We find mu_n GEn/GMn = 0.250 +/- 0.058(stat.) +/- 0.017 (sys.).
△ Less
Submitted 29 August, 2013; v1 submitted 28 July, 2013;
originally announced July 2013.