Skip to main content

Showing 1–8 of 8 results for author: Federau, C

.
  1. Random Expert Sampling for Deep Learning Segmentation of Acute Ischemic Stroke on Non-contrast CT

    Authors: Sophie Ostmeier, Brian Axelrod, Benjamin Pulli, Benjamin F. J. Verhaaren, Abdelkader Mahammedi, Yongkai Liu, Christian Federau, Greg Zaharchuk, Jeremy J. Heit

    Abstract: Purpose: Multi-expert deep learning training methods to automatically quantify ischemic brain tissue on Non-Contrast CT Materials and Methods: The data set consisted of 260 Non-Contrast CTs from 233 patients of acute ischemic stroke patients recruited in the DEFUSE 3 trial. A benchmark U-Net was trained on the reference annotations of three experienced neuroradiologists to segment ischemic brain t… ▽ More

    Submitted 7 September, 2023; originally announced September 2023.

    Journal ref: https://jnis.bmj.com/content/early/2024/02/01/jnis-2023-021283

  2. arXiv:2101.06772  [pdf, other

    eess.IV cs.CV cs.LG

    Latent Space Analysis of VAE and Intro-VAE applied to 3-dimensional MR Brain Volumes of Multiple Sclerosis, Leukoencephalopathy, and Healthy Patients

    Authors: Christopher Vogelsanger, Christian Federau

    Abstract: Multiple Sclerosis (MS) and microvascular leukoencephalopathy are two distinct neurological conditions, the first caused by focal autoimmune inflammation in the central nervous system, the second caused by chronic white matter damage from atherosclerotic microvascular disease. Both conditions lead to signal anomalies on Fluid Attenuated Inversion Recovery (FLAIR) magnetic resonance (MR) images, wh… ▽ More

    Submitted 17 January, 2021; originally announced January 2021.

  3. arXiv:2012.14802  [pdf

    physics.med-ph math.NA

    Signal to Noise and b-value Analysis for Optimal Intra-Voxel Incoherent Motion Imaging in the Brain

    Authors: Harri Merisaari, Christian Federau

    Abstract: Intravoxel incoherent motion (IVIM) is a method that can provide quantitative information about perfusion in the human body, in vivo, and without contrast agent. Unfortunately, the IVIM perfusion parameter maps are known to be relatively noisy in the brain, in particular for the pseudo-diffusion coefficient, which might hinder its potential broader use in clinical applications. Therefore, we studi… ▽ More

    Submitted 29 December, 2020; originally announced December 2020.

    Comments: 26 pages, 5 Figures

  4. arXiv:2012.14771  [pdf

    physics.med-ph eess.IV

    Improved Segmentation and Detection Sensitivity of Diffusion-Weighted Brain Infarct Lesions with Synthetically Enhanced Deep Learning

    Authors: Christian Federau, Soren Christensen, Nino Scherrer, Johanna Ospel, Victor Schulze-Zachau, Noemi Schmidt, Hanns-Christian Breit, Julian Maclaren, Maarten Lansberg, Sebastian Kozerke

    Abstract: Purpose: To compare the segmentation and detection performance of a deep learning model trained on a database of human-labelled clinical diffusion-weighted (DW) stroke lesions to a model trained on the same database enhanced with synthetic DW stroke lesions. Methods: In this institutional review board approved study, a stroke database of 962 cases (mean age 65+/-17 years, 255 males, 449 scans with… ▽ More

    Submitted 29 December, 2020; originally announced December 2020.

    Comments: This manuscript has been accepted for publication in Radiology: Artificial Intelligence

    Journal ref: Radiology: Artificial Intelligence 2020; 2(5):e190217

  5. arXiv:2012.14749  [pdf

    physics.med-ph math.NA

    Simulation of Intravoxel Incoherent Perfusion Signal Using a Realistic Capillary Network of a Mouse Brain

    Authors: Valerie Phi van, Franca Schmid, Georg Spinner, Sebastian Kozerke, Christian Federau

    Abstract: Purpose: To simulate the intravoxel incoherent perfusion magnetic resonance magnitude signal from the motion of blood particles in three realistic vascular network graphs from a mouse brain. Methods: In three networks generated from the cortex of a mouse scanned by two-photon laser microscopy, blood flow in each vessel was simulated using Poiseuille law. The trajectories, flow speeds and phases ac… ▽ More

    Submitted 29 December, 2020; originally announced December 2020.

    Comments: 22 pages, 5 Figures

  6. arXiv:2010.02745  [pdf, other

    eess.IV cs.CV cs.LG

    Image Translation for Medical Image Generation -- Ischemic Stroke Lesions

    Authors: Moritz Platscher, Jonathan Zopes, Christian Federau

    Abstract: Deep learning based disease detection and segmentation algorithms promise to improve many clinical processes. However, such algorithms require vast amounts of annotated training data, which are typically not available in the medical context due to data privacy, legal obstructions, and non-uniform data acquisition protocols. Synthetic databases with annotated pathologies could provide the required… ▽ More

    Submitted 31 October, 2021; v1 submitted 5 October, 2020; originally announced October 2020.

    Comments: 15 pages; 9 figures; 2 tables; content matches published version

  7. arXiv:2008.04594  [pdf, other

    eess.IV cs.CV

    Multi-modal segmentation of 3D brain scans using neural networks

    Authors: Jonathan Zopes, Moritz Platscher, Silvio Paganucci, Christian Federau

    Abstract: Purpose: To implement a brain segmentation pipeline based on convolutional neural networks, which rapidly segments 3D volumes into 27 anatomical structures. To provide an extensive, comparative study of segmentation performance on various contrasts of magnetic resonance imaging (MRI) and computed tomography (CT) scans. Methods: Deep convolutional neural networks are trained to segment 3D MRI (MPRA… ▽ More

    Submitted 11 August, 2020; originally announced August 2020.

  8. arXiv:2006.13944  [pdf

    cs.CV cs.LG eess.IV

    Diffusion-Weighted Magnetic Resonance Brain Images Generation with Generative Adversarial Networks and Variational Autoencoders: A Comparison Study

    Authors: Alejandro UngrĂ­a Hirte, Moritz Platscher, Thomas Joyce, Jeremy J. Heit, Eric Tranvinh, Christian Federau

    Abstract: We show that high quality, diverse and realistic-looking diffusion-weighted magnetic resonance images can be synthesized using deep generative models. Based on professional neuroradiologists' evaluations and diverse metrics with respect to quality and diversity of the generated synthetic brain images, we present two networks, the Introspective Variational Autoencoder and the Style-Based GAN, that… ▽ More

    Submitted 24 June, 2020; originally announced June 2020.

    Comments: 20 pages, 5 figures, 2 tables