-
A Multi-Area Architecture for Real-Time Feedback-Based Optimization of Distribution Grids
Authors:
Ilyas Farhat,
Etinosa Ekomwenrenren,
John W. Simpson-Porco,
Evangelos Farantatos,
Mahendra Patel,
Aboutaleb Haddadi
Abstract:
A challenge in transmission-distribution coordination is how to quickly and reliably coordinate Distributed Energy Resources (DERs) across large multi-stakeholder Distribution Networks (DNs) to support the Transmission Network (TN), while ensuring operational constraints continue to be met within the DN. Here we propose a hierarchical feedback-based control architecture for coordination of DERs in…
▽ More
A challenge in transmission-distribution coordination is how to quickly and reliably coordinate Distributed Energy Resources (DERs) across large multi-stakeholder Distribution Networks (DNs) to support the Transmission Network (TN), while ensuring operational constraints continue to be met within the DN. Here we propose a hierarchical feedback-based control architecture for coordination of DERs in DNs, enabling the DN to quickly respond to power set-point requests from the Transmission System Operator (TSO) while maintaining local DN constraints. Our scheme allows for multiple independently-managed areas within the DN to optimize their local resources while coordinating to support the TN, and while maintaining data privacy; the only required inter-area communication is between physically adjacent areas within the DN control hierarchy. We conduct a rigorous stability analysis, establishing intuitive conditions for closed-loop stability, and provide detailed tuning recommendations. The proposal is validated via case studies on multiple feeders, including IEEE-123 and IEEE-8500, using a custom MATLAB-based application which integrates with OpenDSS. The simulation results show that the proposed structure is highly scalable and can quickly coordinate DERs in response to TSO commands, while responding to local disturbances within the DN and maintaining DN operational limits.
△ Less
Submitted 17 January, 2024;
originally announced January 2024.
-
Data-Driven Fast Frequency Control using Inverter-Based Resources
Authors:
Etinosa Ekomwenrenren,
John W. Simpson-Porco,
Evangelos Farantatos,
Mahendra Patel,
Aboutaleb Haddadi,
Lin Zhu
Abstract:
To address the control challenges associated with the increasing share of inverter-connected renewable energy resources, this paper proposes a direct data-driven approach for fast frequency control in the bulk power system. The proposed control scheme partitions the power system into control areas, and leverages local dispatchable inverter-based resources to rapidly mitigate local power imbalances…
▽ More
To address the control challenges associated with the increasing share of inverter-connected renewable energy resources, this paper proposes a direct data-driven approach for fast frequency control in the bulk power system. The proposed control scheme partitions the power system into control areas, and leverages local dispatchable inverter-based resources to rapidly mitigate local power imbalances upon events. The controller design is based directly on historical measurement sequences, and does not require identification of a parametric power system model. Theoretical results are provided to support the approach. Simulation studies on a nonlinear three-area test system demonstrate that the controller provides fast and localized frequency control under several types of contingencies.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Time-Synchronized Full System State Estimation Considering Practical Implementation Challenges
Authors:
Antos Cheeramban Varghese,
Hritik Shah,
Behrouz Azimian,
Anamitra Pal,
Evangelos Farantatos
Abstract:
As the phasor measurement unit (PMU) placement problem involves a cost-benefit trade-off, more PMUs get placed on the higher voltage buses. However, this causes many of the lower voltage levels of the bulk power system to not be observed by PMUs. This lack of visibility then makes time-synchronized state estimation of the full system a challenging problem. We propose a Deep Neural network-based St…
▽ More
As the phasor measurement unit (PMU) placement problem involves a cost-benefit trade-off, more PMUs get placed on the higher voltage buses. However, this causes many of the lower voltage levels of the bulk power system to not be observed by PMUs. This lack of visibility then makes time-synchronized state estimation of the full system a challenging problem. We propose a Deep Neural network-based State Estimator (DeNSE) to overcome this problem. The DeNSE employs a Bayesian framework to indirectly combine inferences drawn from slow timescale but widespread supervisory control and data acquisition (SCADA) data with fast timescale but select PMU data to attain sub-second situational awareness of the entire system. The practical utility of the proposed approach is demonstrated by considering topology changes, non-Gaussian measurement noise, and bad data detection and correction. The results obtained using the IEEE 118-bus system show the superiority of the DeNSE over a purely SCADA state estimator and a PMU-only linear state estimator from a techno-economic viability perspective. Lastly, scalability of the DeNSE is proven by estimating the states of a large and realistic 2000-bus Synthetic Texas system.
△ Less
Submitted 21 March, 2024; v1 submitted 3 December, 2022;
originally announced December 2022.
-
Data-Driven Fast Frequency Control using Inverter-Based Resources
Authors:
Etinosa Ekomwenrenren,
John Simpson-Porco,
Evangelos Farantatos,
Mahendra Patel,
Aboutaleb Haddadi,
Lin Zhu
Abstract:
We develop and test a data-driven and area-based fast frequency control scheme, which rapidly redispatches inverter-based resources to compensate for local power imbalances within the bulk power system. The approach requires no explicit system model information, relying only on historical measurement sequences for the computation of control actions. Our technical approach fuses developments in low…
▽ More
We develop and test a data-driven and area-based fast frequency control scheme, which rapidly redispatches inverter-based resources to compensate for local power imbalances within the bulk power system. The approach requires no explicit system model information, relying only on historical measurement sequences for the computation of control actions. Our technical approach fuses developments in low-gain estimator design and data-driven control to provide a model-free and practical solution for fast frequency control. Theoretical results and extensive simulation scenarios on a three area system are provided to support the approach.
△ Less
Submitted 2 August, 2022;
originally announced August 2022.
-
Hierarchical Frequency and Voltage Control using Prioritized Utilization of Inverter Based Resources
Authors:
Rahul Chakraborty,
Aranya Chakrabortty,
Evangelos Farantatos,
Mahendra Patel,
Hossein Hooshyar,
Atena Darvishi
Abstract:
We propose a novel hierarchical frequency and voltage control design for multi-area power system integrated with inverter-based resources (IBRs). The design is based on the idea of prioritizing the use of IBRs over conventional generator-based control in compensating for sudden and unpredicted changes in loads and generations, and thereby mitigate any undesired dynamics in the frequency or the vol…
▽ More
We propose a novel hierarchical frequency and voltage control design for multi-area power system integrated with inverter-based resources (IBRs). The design is based on the idea of prioritizing the use of IBRs over conventional generator-based control in compensating for sudden and unpredicted changes in loads and generations, and thereby mitigate any undesired dynamics in the frequency or the voltage by exploiting their fast actuation time constants. A new sequential optimization problem, referred to as Area Prioritized Power Flow (APPF), is formulated to model this prioritization. It is shown that compared to conventional power flow APPF not only leads to a fairer balance between the dispatch of active and reactive power from the IBRs and the synchronous generators, but also limits the impact of any contingency from spreading out beyond its respective control area, thereby guaranteeing a better collective dynamic performance of the grid. This improvement, however, comes at the cost of adding an extra layer of communication needed for executing APPF in a hierarchical way. Results are validated using simulations of a 9-machine, 6-IBR, 33-bus, 3-area power system model, illustrating how APPF can mitigate a disturbance faster and more efficiently by prioritizing the use of local area-resources.
△ Less
Submitted 5 February, 2022; v1 submitted 8 September, 2021;
originally announced September 2021.