Skip to main content

Showing 1–13 of 13 results for author: Fan, I

.
  1. arXiv:2407.02424  [pdf, other

    cs.LG math.CT

    A Pattern Language for Machine Learning Tasks

    Authors: Benjamin Rodatz, Ian Fan, Tuomas Laakkonen, Neil John Ortega, Thomas Hoffman, Vincent Wang-Mascianica

    Abstract: Idealised as universal approximators, learners such as neural networks can be viewed as "variable functions" that may become one of a range of concrete functions after training. In the same way that equations constrain the possible values of variables in algebra, we may view objective functions as constraints on the behaviour of learners. We extract the equivalences perfectly optimised objective f… ▽ More

    Submitted 2 July, 2024; originally announced July 2024.

    MSC Class: 18M30; 68T01 ACM Class: I.2.6

  2. arXiv:2311.00488  [pdf, other

    cs.LG cs.CL

    Comparing Optimization Targets for Contrast-Consistent Search

    Authors: Hugo Fry, Seamus Fallows, Ian Fan, Jamie Wright, Nandi Schoots

    Abstract: We investigate the optimization target of Contrast-Consistent Search (CCS), which aims to recover the internal representations of truth of a large language model. We present a new loss function that we call the Midpoint-Displacement (MD) loss function. We demonstrate that for a certain hyper-parameter value this MD loss function leads to a prober with very similar weights to CCS. We further show t… ▽ More

    Submitted 1 November, 2023; originally announced November 2023.

    Comments: Socially Responsible Language Modelling Research (SoLaR) NeurIPS 2023

  3. Aircraft Skin Inspections: Towards a New Model for Dent Evaluation

    Authors: Pasquale Lafiosca, Ip-Shing Fan, Nicolas P. Avdelidis

    Abstract: Aircraft maintenance, repair and overhaul industry is gradually switching to 3D scanning for dent inspection. High-accuracy devices allow quick and repeatable measurements, which translate into efficient reporting and more objective damage evaluations. However, the potential of 3D scanners is far from being exploited. This is due to the traditional way in which the structural repair manual deals w… ▽ More

    Submitted 11 July, 2023; v1 submitted 25 January, 2023; originally announced January 2023.

  4. arXiv:2205.01614  [pdf, other

    cs.CV cs.LG eess.IV

    Automatic Segmentation of Aircraft Dents in Point Clouds

    Authors: Pasquale Lafiosca, Ip-Shing Fan, Nicolas P. Avdelidis

    Abstract: Dents on the aircraft skin are frequent and may easily go undetected during airworthiness checks, as their inspection process is tedious and extremely subject to human factors and environmental conditions. Nowadays, 3D scanning technologies are being proposed for more reliable, human-independent measurements, yet the process of inspection and reporting remains laborious and time consuming because… ▽ More

    Submitted 24 February, 2023; v1 submitted 3 May, 2022; originally announced May 2022.

  5. arXiv:2110.04236  [pdf, other

    cs.CL cs.AI quant-ph

    lambeq: An Efficient High-Level Python Library for Quantum NLP

    Authors: Dimitri Kartsaklis, Ian Fan, Richie Yeung, Anna Pearson, Robin Lorenz, Alexis Toumi, Giovanni de Felice, Konstantinos Meichanetzidis, Stephen Clark, Bob Coecke

    Abstract: We present lambeq, the first high-level Python library for Quantum Natural Language Processing (QNLP). The open-source toolkit offers a detailed hierarchy of modules and classes implementing all stages of a pipeline for converting sentences to string diagrams, tensor networks, and quantum circuits ready to be used on a quantum computer. lambeq supports syntactic parsing, rewriting and simplificati… ▽ More

    Submitted 8 October, 2021; originally announced October 2021.

  6. arXiv:2008.07975  [pdf, other

    physics.atom-ph nucl-ex

    Revisiting $^{129}$Xe electric dipole moment measurements applying a new global phase fitting approach

    Authors: T. Liu, K. Rolfs, I. Fan, S. Haude, W. Kilian, L. Li, A. Schnabel, J. Voigt, L. Trahms

    Abstract: By measuring the nuclear magnetic spin precession frequencies of polarized $^{129}$Xe and $^{3}$He, a new upper limit on the $^{129}$Xe atomic electric dipole moment (EDM) $ d_\mathrm{A} (^{129}\mathrm{Xe})$ was reported in Phys. Rev. Lett. 123, 143003 (2019). Here, we propose a new evaluation method based on global phase fitting (GPF) for analyzing the continuous phase development of the $^{3}$He… ▽ More

    Submitted 15 November, 2020; v1 submitted 18 August, 2020; originally announced August 2020.

    Comments: Acknowledgement changed; Format changed and several wordings are modified to avoid potential confusions

  7. New Limit on the Permanent Electric Dipole Moment of $^{129}$Xe using $^{3}$He Comagnetometry and SQUID Detection

    Authors: N. Sachdeva, I. Fan, E. Babcock, M. Burghoff, T. E. Chupp, S. Degenkolb, P. Fierlinger, S. Haude, E. Kraegeloh, W. Kilian, S. Knappe-Grüneberg, F. Kuchler, T. Liu, M. Marino, J. Meinel, K. Rolfs, Z. Salhi, A. Schnabel, J. T. Singh, S. Stuiber, W. A. Terrano, L. Trahms, J. Voigt

    Abstract: We report results of a new technique to measure the electric dipole moment of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pum**, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result from a one week measurement camp… ▽ More

    Submitted 26 September, 2019; originally announced September 2019.

    Comments: To be published in Physical Review Letters. arXiv admin note: substantial text overlap with arXiv:1902.02864

  8. arXiv:1902.02864  [pdf, other

    physics.atom-ph physics.ins-det

    A new measurement of the permanent electric dipole moment of $^{129}$Xe using $^{3}$He comagnetometry and SQUID detection

    Authors: N. Sachdeva, I. Fan, E. Babcock, M. Burghoff, T. E. Chupp, S. Degenkolb, P. Fierlinger, E. Kraegeloh, W. Kilian, S. Knappe-Grüneberg, F. Kuchler, T. Liu, M. Marino, J. Meinel, Z. Salhi, A. Schnabel, J. T. Singh, S. Stuiber, W. A. Terrano, L. Trahms, J. Voigt

    Abstract: We describe a new technique to measure the EDM of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pum**, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result of a one week run combined with a detailed study of systemat… ▽ More

    Submitted 7 February, 2019; originally announced February 2019.

  9. arXiv:1403.6467  [pdf, other

    physics.ins-det

    A magnetically shielded room with ultra low residual field and gradient

    Authors: I. Altarev, E. Babcock, D. Beck, M. Burghoff, S. Chesnevskaya, T. Chupp, S. Degenkolb, I. Fan, P. Fierlinger, A. Frei, E. Gutsmiedl, S. Knappe-Grüneberg, F. Kuchler, T. Lauer, P. Link, T. Lins, M. Marino, J. McAndrew, B. Niessen, S. Paul, G. Petzoldt, U. Schläpfer, A. Schnabel, S. Sharma, J. Singh , et al. (7 additional authors not shown)

    Abstract: A versatile and portable magnetically shielded room with a field of (700 \pm 200) pT within a central volume of 1m x 1m x 1m and a field gradient less than 300 pT/m is described. This performance represents more than a hundred-fold improvement of the state of the art for a two-layer magnetic shield and provides an environment suitable for a next generation of precision experiments in fundamental p… ▽ More

    Submitted 24 March, 2014; originally announced March 2014.

    Journal ref: Rev. Sci. Instrum. 85, 075106 (2014)

  10. New Determination of Muonium-Deuterium 1S-2S Isotope Shift

    Authors: Isaac Fan, Chun-Yu Chang, Li-Bang Wang, Simon L. Cornish, Jow-Tsong Shy, Yi-Wei Liu

    Abstract: We report a new determination of muonium 1S-2S transition frequency and its isotope shift with deuterium by recalibrating the iodine reference lines using an optical frequency comb. The reference lines for the muonium and deuterium 1S-2S transitions are determined with a precision of 2.4*10^-10 and 1.7*10^-10 respectively. A new muonium-deuterium 1S-2S isotope-shift frequency is derived from these… ▽ More

    Submitted 6 October, 2013; originally announced October 2013.

    Journal ref: Phys. Rev. A 89, 032513 (2014)

  11. $β$ NMR study of Isolated $^8$Li in the enhanced paramagnet Platinum

    Authors: Oren Ofer, K. H. Chow, I. Fan, M. Egilmez, T. J. Parolin, M. D. Hossain, J. Jung, Z. Salman, R. F. Kiefl, C. D. P. Levy, G. D. Morris, M. R. Pearson, H. Saadaoui, Q. Song, D. Wang, W. A. MacFarlane

    Abstract: We report β detected nuclear magnetic resonance (βNMR) measurements of 8Li+ implanted into high purity Pt. The frequency of the 8Li βNMR resonance and the spin-lattice relaxation rates 1/T1 were measured at temperatures ranging from 3 to 300 K. Remarkably, both the spin-lattice relaxation rate and the Knight shift K depend linearly on temperature T although the bulk susceptibility does not. K is f… ▽ More

    Submitted 19 August, 2012; originally announced August 2012.

    Comments: 8 pages, 4 figures

    Journal ref: Phys. Rev. B 86, 064419 (2012)

  12. arXiv:physics/0703075  [pdf, other

    physics.atom-ph

    Absolute Frequency Measurement of the 378 nm Transition in Thallium

    Authors: Tzu-Ling Chen, Isaac Fan, Chang-Yi Lin, Hsuan-Chen Chen, Shih-En Chen, Jow-Tsong Shy, Yi-Wei Liu

    Abstract: The absolute frequency measurement for all of the hyperfine transitions of 6P1/2 -> 7S1/2 using a self-referencing frequency comb is reported. This transition can be used as a bench marker for the accurate atomic wave function, and then improve the calculation of the atomic parity- non-conservation (PNC). The frequency center is precisely determined by saturation spectroscopy utilizing a pair of t… ▽ More

    Submitted 20 March, 2013; v1 submitted 7 March, 2007; originally announced March 2007.

    Journal ref: 2012, PRA

  13. $β$-NMR of Isolated $^{8}$Li$^{+}$ Implanted into a Thin Copper Film

    Authors: Z. Salman, A. I. Mansour, K. H. Chow, M. Beaudoin, I. Fan, J. Jung, T. A. Keeler, R. F. Kiefl, C. D. P. Levy, R. C. Ma, G. D. Morris, T. J. Parolin, D. Wang, W. A. MacFarlane

    Abstract: Depth-controlled $β$-NMR was used to study highly spin-polarized $^8$Li in a Cu film of thickness 100 nm deposited onto a MgO substrate. The positive Knight Shifts and spin relaxation data show that $^8$Li occupies two sites at low temperatures, assigned to be the substitutional ($S$) and octahedral ($O$) interstitial sites. Between 50 to 100 K, there is a site change from $O$ to $S$. The temper… ▽ More

    Submitted 29 December, 2006; originally announced January 2007.

    Comments: Accepted for publication in Phys. Rev. B

    Journal ref: Phys. Rev. B 75, 073405 (2007)