Rigid and non-rigid motion compensation in weight-bearing cone-beam CT of the knee using (noisy) inertial measurements
Authors:
Jennifer Maier,
Marlies Nitschke,
Jang-Hwan Choi,
Garry Gold,
Rebecca Fahrig,
Bjoern M. Eskofier,
Andreas Maier
Abstract:
Involuntary subject motion is the main source of artifacts in weight-bearing cone-beam CT of the knee. To achieve image quality for clinical diagnosis, the motion needs to be compensated. We propose to use inertial measurement units (IMUs) attached to the leg for motion estimation. We perform a simulation study using real motion recorded with an optical tracking system. Three IMU-based correction…
▽ More
Involuntary subject motion is the main source of artifacts in weight-bearing cone-beam CT of the knee. To achieve image quality for clinical diagnosis, the motion needs to be compensated. We propose to use inertial measurement units (IMUs) attached to the leg for motion estimation. We perform a simulation study using real motion recorded with an optical tracking system. Three IMU-based correction approaches are evaluated, namely rigid motion correction, non-rigid 2D projection deformation and non-rigid 3D dynamic reconstruction. We present an initialization process based on the system geometry. With an IMU noise simulation, we investigate the applicability of the proposed methods in real applications. All proposed IMU-based approaches correct motion at least as good as a state-of-the-art marker-based approach. The structural similarity index and the root mean squared error between motion-free and motion corrected volumes are improved by 24-35% and 78-85%, respectively, compared with the uncorrected case. The noise analysis shows that the noise levels of commercially available IMUs need to be improved by a factor of $10^5$ which is currently only achieved by specialized hardware not robust enough for the application. The presented study confirms the feasibility of this novel approach and defines improvements necessary for a real application.
△ Less
Submitted 24 February, 2021;
originally announced February 2021.
-
X-ray Scatter Estimation Using Deep Splines
Authors:
Philipp Roser,
Annette Birkhold,
Alexander Preuhs,
Christopher Syben,
Lina Felsner,
Elisabeth Hoppe,
Norbert Strobel,
Markus Korwarschik,
Rebecca Fahrig,
Andreas Maier
Abstract:
Algorithmic X-ray scatter compensation is a desirable technique in flat-panel X-ray imaging and cone-beam computed tomography. State-of-the-art U-net based image translation approaches yielded promising results. As there are no physics constraints applied to the output of the U-Net, it cannot be ruled out that it yields spurious results. Unfortunately, those may be misleading in the context of med…
▽ More
Algorithmic X-ray scatter compensation is a desirable technique in flat-panel X-ray imaging and cone-beam computed tomography. State-of-the-art U-net based image translation approaches yielded promising results. As there are no physics constraints applied to the output of the U-Net, it cannot be ruled out that it yields spurious results. Unfortunately, those may be misleading in the context of medical imaging. To overcome this problem, we propose to embed B-splines as a known operator into neural networks. This inherently limits their predictions to well-behaved and smooth functions. In a study using synthetic head and thorax data as well as real thorax phantom data, we found that our approach performed on par with U-net when comparing both algorithms based on quantitative performance metrics. However, our approach not only reduces runtime and parameter complexity, but we also found it much more robust to unseen noise levels. While the U-net responded with visible artifacts, our approach preserved the X-ray signal's frequency characteristics.
△ Less
Submitted 22 January, 2021;
originally announced January 2021.
-
Inertial Measurements for Motion Compensation in Weight-bearing Cone-beam CT of the Knee
Authors:
Jennifer Maier,
Marlies Nitschke,
Jang-Hwan Choi,
Garry Gold,
Rebecca Fahrig,
Bjoern M. Eskofier,
Andreas Maier
Abstract:
Involuntary motion during weight-bearing cone-beam computed tomography (CT) scans of the knee causes artifacts in the reconstructed volumes making them unusable for clinical diagnosis. Currently, image-based or marker-based methods are applied to correct for this motion, but often require long execution or preparation times. We propose to attach an inertial measurement unit (IMU) containing an acc…
▽ More
Involuntary motion during weight-bearing cone-beam computed tomography (CT) scans of the knee causes artifacts in the reconstructed volumes making them unusable for clinical diagnosis. Currently, image-based or marker-based methods are applied to correct for this motion, but often require long execution or preparation times. We propose to attach an inertial measurement unit (IMU) containing an accelerometer and a gyroscope to the leg of the subject in order to measure the motion during the scan and correct for it. To validate this approach, we present a simulation study using real motion measured with an optical 3D tracking system. With this motion, an XCAT numerical knee phantom is non-rigidly deformed during a simulated CT scan creating motion corrupted projections. A biomechanical model is animated with the same tracked motion in order to generate measurements of an IMU placed below the knee. In our proposed multi-stage algorithm, these signals are transformed to the global coordinate system of the CT scan and applied for motion compensation during reconstruction. Our proposed approach can effectively reduce motion artifacts in the reconstructed volumes. Compared to the motion corrupted case, the average structural similarity index and root mean squared error with respect to the no-motion case improved by 13-21% and 68-70%, respectively. These results are qualitatively and quantitatively on par with a state-of-the-art marker-based method we compared our approach to. The presented study shows the feasibility of this novel approach, and yields promising results towards a purely IMU-based motion compensation in C-arm CT.
△ Less
Submitted 9 July, 2020;
originally announced July 2020.
-
Simultaneous Estimation of X-ray Back-Scatter and Forward-Scatter using Multi-Task Learning
Authors:
Philipp Roser,
Xia Zhong,
Annette Birkhold,
Alexander Preuhs,
Christopher Syben,
Elisabeth Hoppe,
Norbert Strobel,
Markus Kowarschik,
Rebecca Fahrig,
Andreas Maier
Abstract:
Scattered radiation is a major concern impacting X-ray image-guided procedures in two ways. First, back-scatter significantly contributes to patient (skin) dose during complicated interventions. Second, forward-scattered radiation reduces contrast in projection images and introduces artifacts in 3-D reconstructions. While conventionally employed anti-scatter grids improve image quality by blocking…
▽ More
Scattered radiation is a major concern impacting X-ray image-guided procedures in two ways. First, back-scatter significantly contributes to patient (skin) dose during complicated interventions. Second, forward-scattered radiation reduces contrast in projection images and introduces artifacts in 3-D reconstructions. While conventionally employed anti-scatter grids improve image quality by blocking X-rays, the additional attenuation due to the anti-scatter grid at the detector needs to be compensated for by a higher patient entrance dose. This also increases the room dose affecting the staff caring for the patient. For skin dose quantification, back-scatter is usually accounted for by applying pre-determined scalar back-scatter factors or linear point spread functions to a primary kerma forward projection onto a patient surface point. However, as patients come in different shapes, the generalization of conventional methods is limited. Here, we propose a novel approach combining conventional techniques with learning-based methods to simultaneously estimate the forward-scatter reaching the detector as well as the back-scatter affecting the patient skin dose. Knowing the forward-scatter, we can correct X-ray projections, while a good estimate of the back-scatter component facilitates an improved skin dose assessment. To simultaneously estimate forward-scatter as well as back-scatter, we propose a multi-task approach for joint back- and forward-scatter estimation by combining X-ray physics with neural networks. We show that, in theory, highly accurate scatter estimation in both cases is possible. In addition, we identify research directions for our multi-task framework and learning-based scatter estimation in general.
△ Less
Submitted 8 July, 2020;
originally announced July 2020.
-
Pitfalls in interventional X-ray organ dose assessment -- combined experimental and computational phantom study: application to prostatic artery embolization
Authors:
Philipp Roser,
Annette Birkhold,
Xia Zhong,
Philipp Ochs,
Elizaveta Stepina,
Markus Kowarschik,
Rebecca Fahrig,
Andreas Maier
Abstract:
With X-ray radiation protection and dose management constantly gaining interest in interventional radiology, novel procedures often undergo prospective dose studies using anthropomorphic phantoms to determine expected dose values. Due to inherent uncertainties, these dose values might not allow for patient-specific risk assessment. Therefore, first the aim of this study is to quantify the influenc…
▽ More
With X-ray radiation protection and dose management constantly gaining interest in interventional radiology, novel procedures often undergo prospective dose studies using anthropomorphic phantoms to determine expected dose values. Due to inherent uncertainties, these dose values might not allow for patient-specific risk assessment. Therefore, first the aim of this study is to quantify the influence of these parameters on local X-ray dose to evaluate their relevance in the assessment of patient-specific organ doses. Second, this knowledge further enables validating a simulation approach, which allows employing physiological material models and patient-specific geometries. Phantom dosimetry experiments using MOSFET dosimeters were conducted reproducing imaging scenarios in prostatic arterial embolization (PAE). Associated organ-equivalent dose of prostate, bladder, colon and skin was determined. Dose deviation induced by possible small displacements of the patient was reproduced by moving the X-ray source. Dose deviation induced by material differences was investigated by analyzing two different commonly used phantoms. We reconstructed the experiments using Monte Carlo (MC) simulations, a reference male geometry, and different material properties. Overall, MC simulated organ dose values are in accordance with the measured ones for the majority of cases. Marginal displacements of X-ray source relative to the phantoms lead to deviations of 6% to 135% in organ dose values, while skin dose remains relatively constant. Regarding the impact of phantom material composition, underestimation of internal organ dose values by 12% to 20% is prevalent in all simulated phantoms. Skin dose, however, can be estimated with low deviation of 1% to 8% at least for two materials. Prospective reference dose studies might not extend to precise patient-specific dose assessment.
△ Less
Submitted 7 May, 2020;
originally announced May 2020.
-
Effects of Tissue Material Properties on X-Ray Image, Scatter and Patient Dose Determined using Monte Carlo Simulations
Authors:
Philipp Roser,
Annette Birkhold,
Xia Zhong,
Elizaveta Stepina,
Markus Kowarschik,
Rebecca Fahrig,
Andreas Maier
Abstract:
With increasing patient and staff X-ray radiation awareness, many efforts have been made to develop accurate patient dose estimation methods. To date, Monte Carlo (MC) simulations are considered golden standard to simulate the interaction of X-ray radiation with matter. However, sensitivity of MC simulation results to variations in the experimental or clinical setup of image guided interventional…
▽ More
With increasing patient and staff X-ray radiation awareness, many efforts have been made to develop accurate patient dose estimation methods. To date, Monte Carlo (MC) simulations are considered golden standard to simulate the interaction of X-ray radiation with matter. However, sensitivity of MC simulation results to variations in the experimental or clinical setup of image guided interventional procedures are only limited studied. In particular, the impact of patient material compositions is poorly investigated. This is mainly due to the fact, that these methods are commonly validated in phantom studies utilizing a single anthropomorphic phantom. In this study, we therefore investigate the impact of patient material parameters map** on the outcome of MC X-ray dose simulations. A computation phantom geometry is constructed and three different commonly used material composition map**s are applied. We used the MC toolkit Geant4 to simulate X-ray radiation in an interventional setup and compared the differences in dose deposition, scatter distributions and resulting X-ray images. The evaluation shows a discrepancy between different material composition map** up to 20 % concerning directly irradiated organs. These results highlight the need for standardization of material composition map** for MC simulations in a clinical setup.
△ Less
Submitted 7 May, 2020;
originally announced May 2020.
-
Fully-automatic CT data preparation for interventional X-ray skin dose simulation
Authors:
Philipp Roser,
Annette Birkhold,
Alexander Preuhs,
Bernhard Stimpel,
Christopher Syben,
Norbert Strobel,
Markus Kowarschik,
Rebecca Fahrig,
Andreas Maier
Abstract:
Recently, deep learning (DL) found its way to interventional X-ray skin dose estimation. While its performance was found to be acceptable, even more accurate results could be achieved if more data sets were available for training. One possibility is to turn to computed tomography (CT) data sets. Typically, computed tomography (CT) scans can be mapped to tissue labels and mass densities to obtain t…
▽ More
Recently, deep learning (DL) found its way to interventional X-ray skin dose estimation. While its performance was found to be acceptable, even more accurate results could be achieved if more data sets were available for training. One possibility is to turn to computed tomography (CT) data sets. Typically, computed tomography (CT) scans can be mapped to tissue labels and mass densities to obtain training data. However, care has to be taken to make sure that the different clinical settings are properly accounted for. First, the interventional environment is characterized by wide variety of table setups that are significantly different from the typical patient tables used in conventional CT. This cannot be ignored, since tables play a crucial role in sound skin dose estimation in an interventional setup, e. g., when the X-ray source is directly underneath a patient (posterior-anterior view). Second, due to interpolation errors, most CT scans do not facilitate a clean segmentation of the skin border. As a solution to these problems, we applied connected component labeling (CCL) and Canny edge detection to (a) robustly separate the patient from the table and (b) to identify the outermost skin layer. Our results show that these extensions enable fully-automatic, generalized pre-processing of CT scans for further simulation of both skin dose and corresponding X-ray projections.
△ Less
Submitted 7 May, 2020;
originally announced May 2020.
-
Tenfold your photons -- a physically-sound approach to filtering-based variance reduction of Monte-Carlo-simulated dose distributions
Authors:
Philipp Roser,
Annette Birkhold,
Alexander Preuhs,
Markus Kowarschik,
Rebecca Fahrig,
Andreas Maier
Abstract:
X-ray dose constantly gains interest in the interventional suite. With dose being generally difficult to monitor reliably, fast computational methods are desirable. A major drawback of the gold standard based on Monte Carlo (MC) methods is its computational complexity. Besides common variance reduction techniques, filter approaches are often applied to achieve conclusive results within a fraction…
▽ More
X-ray dose constantly gains interest in the interventional suite. With dose being generally difficult to monitor reliably, fast computational methods are desirable. A major drawback of the gold standard based on Monte Carlo (MC) methods is its computational complexity. Besides common variance reduction techniques, filter approaches are often applied to achieve conclusive results within a fraction of time. Inspired by these methods, we propose a novel approach. We down-sample the target volume based on the fraction of mass, simulate the imaging situation, and then revert the down-sampling. To this end, the dose is weighted by the mass energy absorption, up-sampled, and distributed using a guided filter. Eventually, the weighting is inverted resulting in accurate high resolution dose distributions. The approach has the potential to considerably speed-up MC simulations since less photons and boundary checks are necessary. First experiments substantiate these assumptions. We achieve a median accuracy of 96.7 % to 97.4 % of the dose estimation with the proposed method and a down-sampling factor of 8 and 4, respectively. While maintaining a high accuracy, the proposed method provides for a tenfold speed-up. The overall findings suggest the conclusion that the proposed method has the potential to allow for further efficiency.
△ Less
Submitted 7 May, 2020;
originally announced May 2020.
-
Deep Scatter Splines: Learning-Based Medical X-ray Scatter Estimation Using B-splines
Authors:
Philipp Roser,
Annette Birkhold,
Alexander Preuhs,
Christopher Syben,
Norbert Strobel,
Markus Korwarschik,
Rebecca Fahrig,
Andreas Maier
Abstract:
The idea of replacing hardware by software to compensate for scattered radiation in flat-panel X-ray imaging is well established in the literature. Recently, deep-learningbased image translation approaches, most notably the U-Net, have emerged for scatter estimation. These yield considerable improvements over model-based methods. Such networks, however, involve potential drawbacks that need to be…
▽ More
The idea of replacing hardware by software to compensate for scattered radiation in flat-panel X-ray imaging is well established in the literature. Recently, deep-learningbased image translation approaches, most notably the U-Net, have emerged for scatter estimation. These yield considerable improvements over model-based methods. Such networks, however, involve potential drawbacks that need to be considered. First, they are trained in a data-driven fashion without making use of prior knowledge and X-ray physics. Second, due to their high parameter complexity, the validity of deep neural networks is difficult to assess. To circumvent these issues, we introduce here a surrogate function to model X-ray scatter distributions that can be expressed by few parameters. We could show empirically that cubic B-splines are well-suited to model X-ray scatter in the diagnostic energy regime. Based on these findings, we propose a lean convolutional encoder architecture that extracts local scatter characteristics from X-ray projection images. These characteristics are embedded into a global context using a constrained weighting matrix yielding spline coefficients that model the scatter distribution. In a first simulation study with 17 thorax data sets, we could show that our method and the U-Net-based state of the art reach about the same accuracy. However, we could achieve these comparable outcomes with orders of magnitude fewer parameters while ensuring that not high-frequency information gets manipulated.
△ Less
Submitted 7 May, 2020;
originally announced May 2020.
-
An Investigation of Feature-based Nonrigid Image Registration using Gaussian Process
Authors:
Siming Bayer,
Ute Spiske,
Jie Luo,
Tobias Geimer,
William M. Wells III,
Martin Ostermeier,
Rebecca Fahrig,
Arya Nabavi,
Christoph Bert,
Ilker Eyupoglo,
Andreas Maier
Abstract:
For a wide range of clinical applications, such as adaptive treatment planning or intraoperative image update, feature-based deformable registration (FDR) approaches are widely employed because of their simplicity and low computational complexity. FDR algorithms estimate a dense displacement field by interpolating a sparse field, which is given by the established correspondence between selected fe…
▽ More
For a wide range of clinical applications, such as adaptive treatment planning or intraoperative image update, feature-based deformable registration (FDR) approaches are widely employed because of their simplicity and low computational complexity. FDR algorithms estimate a dense displacement field by interpolating a sparse field, which is given by the established correspondence between selected features. In this paper, we consider the deformation field as a Gaussian Process (GP), whereas the selected features are regarded as prior information on the valid deformations. Using GP, we are able to estimate the both dense displacement field and a corresponding uncertainty map at once. Furthermore, we evaluated the performance of different hyperparameter settings for squared exponential kernels with synthetic, phantom and clinical data respectively. The quantitative comparison shows, GP-based interpolation has performance on par with state-of-the-art B-spline interpolation. The greatest clinical benefit of GP-based interpolation is that it gives a reliable estimate of the mathematical uncertainty of the calculated dense displacement map.
△ Less
Submitted 12 January, 2020;
originally announced January 2020.
-
Multi-Channel Volumetric Neural Network for Knee Cartilage Segmentation in Cone-beam CT
Authors:
Jennifer Maier,
Luis Carlos Rivera Monroy,
Christopher Syben,
Ye** Jeon,
Jang-Hwan Choi,
Mary Elizabeth Hall,
Marc Levenston,
Garry Gold,
Rebecca Fahrig,
Andreas Maier
Abstract:
Analyzing knee cartilage thickness and strain under load can help to further the understanding of the effects of diseases like Osteoarthritis. A precise segmentation of the cartilage is a necessary prerequisite for this analysis. This segmentation task has mainly been addressed in Magnetic Resonance Imaging, and was rarely investigated on contrast-enhanced Computed Tomography, where contrast agent…
▽ More
Analyzing knee cartilage thickness and strain under load can help to further the understanding of the effects of diseases like Osteoarthritis. A precise segmentation of the cartilage is a necessary prerequisite for this analysis. This segmentation task has mainly been addressed in Magnetic Resonance Imaging, and was rarely investigated on contrast-enhanced Computed Tomography, where contrast agent visualizes the border between femoral and tibial cartilage. To overcome the main drawback of manual segmentation, namely its high time investment, we propose to use a 3D Convolutional Neural Network for this task. The presented architecture consists of a V-Net with SeLu activation, and a Tversky loss function. Due to the high imbalance between very few cartilage pixels and many background pixels, a high false positive rate is to be expected. To reduce this rate, the two largest segmented point clouds are extracted using a connected component analysis, since they most likely represent the medial and lateral tibial cartilage surfaces. The resulting segmentations are compared to manual segmentations, and achieve on average a recall of 0.69, which confirms the feasibility of this approach.
△ Less
Submitted 3 December, 2019;
originally announced December 2019.
-
Action Learning for 3D Point Cloud Based Organ Segmentation
Authors:
Xia Zhong,
Mario Amrehn,
Nishant Ravikumar,
Shuqing Chen,
Norbert Strobel,
Annette Birkhold,
Markus Kowarschik,
Rebecca Fahrig,
Andreas Maier
Abstract:
We propose a novel point cloud based 3D organ segmentation pipeline utilizing deep Q-learning. In order to preserve shape properties, the learning process is guided using a statistical shape model. The trained agent directly predicts piece-wise linear transformations for all vertices in each iteration. This map** between the ideal transformation for an object outline estimation is learned based…
▽ More
We propose a novel point cloud based 3D organ segmentation pipeline utilizing deep Q-learning. In order to preserve shape properties, the learning process is guided using a statistical shape model. The trained agent directly predicts piece-wise linear transformations for all vertices in each iteration. This map** between the ideal transformation for an object outline estimation is learned based on image features. To this end, we introduce aperture features that extract gray values by sampling the 3D volume within the cone centered around the associated vertex and its normal vector. Our approach is also capable of estimating a hierarchical pyramid of non rigid deformations for multi-resolution meshes. In the application phase, we use a marginal approach to gradually estimate affine as well as non-rigid transformations. We performed extensive evaluations to highlight the robust performance of our approach on a variety of challenge data as well as clinical data. Additionally, our method has a run time ranging from 0.3 to 2.7 seconds to segment each organ. In addition, we show that the proposed method can be applied to different organs, X-ray based modalities, and scanning protocols without the need of transfer learning. As we learn actions, even unseen reference meshes can be processed as demonstrated in an example with the Visible Human. From this we conclude that our method is robust, and we believe that our method can be successfully applied to many more applications, in particular, in the interventional imaging space.
△ Less
Submitted 14 June, 2018;
originally announced June 2018.
-
Precision Learning: Towards Use of Known Operators in Neural Networks
Authors:
Andreas Maier,
Frank Schebesch,
Christopher Syben,
Tobias Würfl,
Stefan Steidl,
Jang-Hwan Choi,
Rebecca Fahrig
Abstract:
In this paper, we consider the use of prior knowledge within neural networks. In particular, we investigate the effect of a known transform within the map** from input data space to the output domain. We demonstrate that use of known transforms is able to change maximal error bounds.
In order to explore the effect further, we consider the problem of X-ray material decomposition as an example t…
▽ More
In this paper, we consider the use of prior knowledge within neural networks. In particular, we investigate the effect of a known transform within the map** from input data space to the output domain. We demonstrate that use of known transforms is able to change maximal error bounds.
In order to explore the effect further, we consider the problem of X-ray material decomposition as an example to incorporate additional prior knowledge. We demonstrate that inclusion of a non-linear function known from the physical properties of the system is able to reduce prediction errors therewith improving prediction quality from SSIM values of 0.54 to 0.88.
This approach is applicable to a wide set of applications in physics and signal processing that provide prior knowledge on such transforms. Also maximal error estimation and network understanding could be facilitated within the context of precision learning.
△ Less
Submitted 12 October, 2018; v1 submitted 1 December, 2017;
originally announced December 2017.
-
Precision Learning: Reconstruction Filter Kernel Discretization
Authors:
Christopher Syben,
Bernhard Stimpel,
Katharina Breininger,
Tobias Würfl,
Rebecca Fahrig,
Arnd Dörfler,
Andreas Maier
Abstract:
In this paper, we present substantial evidence that a deep neural network will intrinsically learn the appropriate way to discretize the ideal continuous reconstruction filter. Currently, the Ram-Lak filter or heuristic filters which impose different noise assumptions are used for filtered back-projection. All of these, however, inhibit a fully data-driven reconstruction deep learning approach. In…
▽ More
In this paper, we present substantial evidence that a deep neural network will intrinsically learn the appropriate way to discretize the ideal continuous reconstruction filter. Currently, the Ram-Lak filter or heuristic filters which impose different noise assumptions are used for filtered back-projection. All of these, however, inhibit a fully data-driven reconstruction deep learning approach. In addition, the heuristic filters are not chosen in an optimal sense. To tackle this issue, we propose a formulation to directly learn the reconstruction filter. The filter is initialized with the ideal Ramp filter as a strong pre-training and learned in frequency domain. We compare the learned filter with the Ram-Lak and the Ramp filter on a numerical phantom as well as on a real CT dataset. The results show that the network properly discretizes the continuous Ramp filter and converges towards the Ram-Lak solution. In our view these observations are interesting to gain a better understanding of deep learning techniques and traditional analytic techniques such as Wiener filtering and discretization theory. Furthermore, this will allow fully trainable data-driven reconstruction deep learning approaches.
△ Less
Submitted 9 July, 2018; v1 submitted 17 October, 2017;
originally announced October 2017.
-
Path-based Iterative Reconstruction (PBIR) for X-ray Computed Tomography
Authors:
Meng Wu,
Andreas Maier,
Qiao Yang,
Rebecca Fahrig
Abstract:
Model-based iterative reconstruction (MBIR) techniques have demonstrated many advantages in X-ray CT image reconstruction. The MBIR approach is often modeled as a convex optimization problem including a data fitting function and a penalty function. The tuning parameter value that regulates the strength of the penalty function is critical for achieving good reconstruction results but difficult to c…
▽ More
Model-based iterative reconstruction (MBIR) techniques have demonstrated many advantages in X-ray CT image reconstruction. The MBIR approach is often modeled as a convex optimization problem including a data fitting function and a penalty function. The tuning parameter value that regulates the strength of the penalty function is critical for achieving good reconstruction results but difficult to choose. In this work, we describe two path seeking algorithms that are capable of efficiently generating a series of MBIR images with different strengths of the penalty function. The root-mean-squared-differences of the proposed path seeking algorithms are below 4 HU throughout the entire reconstruction path. With the efficient path seeking algorithm, we suggest a path-based iterative reconstruction (PBIR) to obtain complete information from the scanned data and reconstruction model.
△ Less
Submitted 7 December, 2015;
originally announced December 2015.