arXiv:1111.7060
[pdf]
physics.ins-det
cond-mat.other
nucl-ex
physics.comp-ph
physics.med-ph
quant-ph
Radiation Dam** for Speeding-up NMR Applications
Authors:
Gennady P. Berman,
Michelle A. Espy,
Vyacheslav N. Gorshkov,
Vladimir I. Tsifrinovich,
Petr L. Volegov
Abstract:
We demonstrate theoretically and numerically how to control the NMR relaxation rate after application of the standard spin echo technique. Using radiation dam**, we return the nuclear magnetization to its equilibrium state during a time interval that is negligible compared to the relaxation time. We obtain an estimate for optimal radiation dam** which is consistent with our numerical simulatio…
▽ More
We demonstrate theoretically and numerically how to control the NMR relaxation rate after application of the standard spin echo technique. Using radiation dam**, we return the nuclear magnetization to its equilibrium state during a time interval that is negligible compared to the relaxation time. We obtain an estimate for optimal radiation dam** which is consistent with our numerical simulations.
△ Less
Submitted 25 November, 2011;
originally announced November 2011.
-
Microtesla MRI with dynamic nuclear polarization
Authors:
V. S. Zotev,
T. Owens,
A. N. Matlashov,
I. M. Savukov,
J. J. Gomez,
M. A. Espy
Abstract:
Magnetic resonance imaging at microtesla fields is a promising imaging method that combines the pre-polarization technique and broadband signal reception by SQUID sensors to enable in vivo MRI at microtesla-range magnetic fields. Despite significant advances, the potential of microtesla MRI for biomedical imaging is limited by its insufficient signal-to-noise ratio due to a relatively low sample p…
▽ More
Magnetic resonance imaging at microtesla fields is a promising imaging method that combines the pre-polarization technique and broadband signal reception by SQUID sensors to enable in vivo MRI at microtesla-range magnetic fields. Despite significant advances, the potential of microtesla MRI for biomedical imaging is limited by its insufficient signal-to-noise ratio due to a relatively low sample polarization. Dynamic nuclear polarization (DNP) is a widely used approach that allows polarization enhancement by two-four orders of magnitude without an increase in the polarizing field strength. In this work, the first implementation of microtesla MRI with Overhauser DNP and SQUID signal detection is described. The first measurements of carbon-13 NMR spectra at microtesla fields are also reported. The experiments were performed at the measurement field of 96 microtesla with Overhauser enhancement at 3.5 - 5.7 mT field. The Overhauser DNP enabled nuclear polarization enhancement by factor as high as -95 for protons and as high as -200 for carbon-13, corresponding to thermal polarizations at 0.33 T and 1.1 T fields, respectively. These results demonstrate that SQUID-based microtesla MRI can be naturally combined with Overhauser DNP in one system, and that its signal-to-noise performance is greatly improved in this case. They also suggest that microtesla MRI can become an efficient tool for in vivo imaging of hyperpolarized carbon-13, produced by the low-temperature dissolution DNP.
△ Less
Submitted 11 July, 2010; v1 submitted 5 November, 2009;
originally announced November 2009.
-
SQUID-based microtesla MRI for in vivo relaxometry of the human brain
Authors:
V. S. Zotev,
P. L. Volegov,
A. N. Matlashov,
I. M. Savukov,
T. Owens,
M. A. Espy
Abstract:
SQUID-based MRI (magnetic resonance imaging) at microtesla fields has developed significantly over the past few years. Here we describe application of this method for magnetic relaxation measurements in the living human brain. We report values of the longitudinal relaxation time T1 for brain tissues, measured in vivo for the first time at microtesla fields. The experiments were performed at 46 m…
▽ More
SQUID-based MRI (magnetic resonance imaging) at microtesla fields has developed significantly over the past few years. Here we describe application of this method for magnetic relaxation measurements in the living human brain. We report values of the longitudinal relaxation time T1 for brain tissues, measured in vivo for the first time at microtesla fields. The experiments were performed at 46 microtesla field using a seven-channel SQUID system designed for microtesla MRI and MEG. Values of T1, measured for different tissues at this field, are found to be close (within 5%) to the corresponding values of the transverse relaxation time T2 at the same field. Implications of this result for imaging contrast in microtesla MRI are discussed.
△ Less
Submitted 3 November, 2008;
originally announced November 2008.
-
Microtesla MRI of the human brain combined with MEG
Authors:
V. S. Zotev,
A. N. Matlashov,
P. L. Volegov,
I. M. Savukov,
M. A. Espy,
J. C. Mosher,
J. J. Gomez,
R. H. Kraus Jr
Abstract:
One of the challenges in functional brain imaging is integration of complementary imaging modalities, such as magnetoencephalography (MEG) and functional magnetic resonance imaging (fMRI). MEG, which uses highly sensitive superconducting quantum interference devices (SQUIDs) to directly measure magnetic fields of neuronal currents, cannot be combined with conventional high-field MRI in a single…
▽ More
One of the challenges in functional brain imaging is integration of complementary imaging modalities, such as magnetoencephalography (MEG) and functional magnetic resonance imaging (fMRI). MEG, which uses highly sensitive superconducting quantum interference devices (SQUIDs) to directly measure magnetic fields of neuronal currents, cannot be combined with conventional high-field MRI in a single instrument. Indirect matching of MEG and MRI data leads to significant co-registration errors. A recently proposed imaging method - SQUID-based microtesla MRI - can be naturally combined with MEG in the same system to directly provide structural maps for MEG-localized sources. It enables easy and accurate integration of MEG and MRI/fMRI, because microtesla MR images can be precisely matched to structural images provided by high-field MRI and other techniques. Here we report the first images of the human brain by microtesla MRI, together with auditory MEG (functional) data, recorded using the same seven-channel SQUID system during the same imaging session. The images were acquired at 46 microtesla measurement field with pre-polarization at 30 mT. We also estimated transverse relaxation times for different tissues at microtesla fields. Our results demonstrate feasibility and potential of human brain imaging by microtesla MRI. They also show that two new types of imaging equipment - low-cost systems for anatomical MRI of the human brain at microtesla fields, and more advanced instruments for combined functional (MEG) and structural (microtesla MRI) brain imaging - are practical.
△ Less
Submitted 28 June, 2008; v1 submitted 1 November, 2007;
originally announced November 2007.
-
SQUID-based instrumentation for ultra-low-field MRI
Authors:
V. S. Zotev,
A. N. Matlashov,
P. L. Volegov,
A. V. Urbaitis,
M. A. Espy,
R. H. Kraus Jr
Abstract:
Magnetic resonance imaging at ultra-low fields (ULF MRI) is a promising new imaging method that uses SQUID sensors to measure the spatially encoded precession of pre-polarized nuclear spin populations at a microtesla-range measurement field. In this work, a seven-channel SQUID system designed for simultaneous 3D ULF MRI and magnetoencephalography (MEG) is described. The system includes seven sec…
▽ More
Magnetic resonance imaging at ultra-low fields (ULF MRI) is a promising new imaging method that uses SQUID sensors to measure the spatially encoded precession of pre-polarized nuclear spin populations at a microtesla-range measurement field. In this work, a seven-channel SQUID system designed for simultaneous 3D ULF MRI and magnetoencephalography (MEG) is described. The system includes seven second-order SQUID gradiometers, characterized by magnetic field resolutions of 1.2 - 2.8 fT/rtHz. It is also equipped with five sets of coils for 3D Fourier imaging with pre-polarization. Essential technical details of the design are discussed. The system's ULF MRI performance is demonstrated by multi-channel 3D images of a preserved sheep brain acquired at 46 microtesla measurement field with pre-polarization at 40 mT. The imaging resolution is 2.5 mm x 2.5 mm x 5 mm. The ULF MRI images are compared to images of the same brain acquired using conventional high-field MRI. Different ways to improve imaging SNR are discussed.
△ Less
Submitted 30 July, 2007; v1 submitted 4 May, 2007;
originally announced May 2007.
-
Parallel MRI at microtesla fields
Authors:
V. S. Zotev,
P. L. Volegov,
A. N. Matlashov,
M. A. Espy,
J. C. Mosher,
R. H. Kraus Jr
Abstract:
Parallel imaging techniques have been widely used in high-field magnetic resonance imaging (MRI). Multiple receiver coils have been shown to improve image quality and allow accelerated image acquisition. Magnetic resonance imaging at ultra-low fields (ULF MRI) is a new imaging approach that uses SQUID (superconducting quantum interference device) sensors to measure the spatially encoded precessi…
▽ More
Parallel imaging techniques have been widely used in high-field magnetic resonance imaging (MRI). Multiple receiver coils have been shown to improve image quality and allow accelerated image acquisition. Magnetic resonance imaging at ultra-low fields (ULF MRI) is a new imaging approach that uses SQUID (superconducting quantum interference device) sensors to measure the spatially encoded precession of pre-polarized nuclear spin populations at microtesla-range measurement fields. In this work, parallel imaging at microtesla fields is systematically studied for the first time. A seven-channel SQUID system, designed for both ULF MRI and magnetoencephalography (MEG), is used to acquire 3D images of a human hand, as well as 2D images of a large water phantom. The imaging is performed at 46 microtesla measurement field with pre-polarization at 40 mT. It is shown how the use of seven channels increases imaging field of view and improves signal-to-noise ratio for the hand images. A simple procedure for approximate correction of concomitant gradient artifacts is described. Noise propagation is analyzed experimentally, and the main source of correlated noise is identified. Accelerated imaging based on one-dimensional undersampling and 1D SENSE (sensitivity encoding) image reconstruction is studied in the case of the 2D phantom. Actual 3-fold imaging acceleration in comparison to single-average fully encoded Fourier imaging is demonstrated. These results show that parallel imaging methods are efficient in ULF MRI, and that imaging performance of SQUID-based instruments improves substantially as the number of channels is increased.
△ Less
Submitted 27 March, 2008; v1 submitted 16 January, 2007;
originally announced January 2007.
-
Multi-sensor system for simultaneous ultra-low-field MRI and MEG
Authors:
V. S. Zotev,
A. N. Matlachov,
P. L. Volegov,
H. J. Sandin,
M. A. Espy,
J. C. Mosher,
A. V. Urbaitis,
S. G. Newman,
R. H. Kraus Jr
Abstract:
Magnetoencephalography (MEG) and magnetic resonance imaging at ultra-low fields (ULF MRI) are two methods based on the ability of SQUID (superconducting quantum interference device) sensors to detect femtotesla magnetic fields. Combination of these methods will allow simultaneous functional (MEG) and structural (ULF MRI) imaging of the human brain. In this paper, we report the first implementati…
▽ More
Magnetoencephalography (MEG) and magnetic resonance imaging at ultra-low fields (ULF MRI) are two methods based on the ability of SQUID (superconducting quantum interference device) sensors to detect femtotesla magnetic fields. Combination of these methods will allow simultaneous functional (MEG) and structural (ULF MRI) imaging of the human brain. In this paper, we report the first implementation of a multi-sensor SQUID system designed for both MEG and ULF MRI. We present a multi-channel image of a human hand obtained at 46 microtesla field, as well as results of auditory MEG measurements with the new system.
△ Less
Submitted 5 December, 2006;
originally announced December 2006.
-
Multi-Channel SQUID System for MEG and Ultra-Low-Field MRI
Authors:
Vadim S. Zotev,
Andrei N. Matlachov,
Petr L. Volegov,
Henrik J. Sandin,
Michelle A. Espy,
John C. Mosher,
Algis V. Urbaitis,
Shaun G. Newman,
Robert H. Kraus Jr
Abstract:
A seven-channel system capable of performing both magnetoencephalography (MEG) and ultra-low-field magnetic resonance imaging (ULF MRI) is described. The system consists of seven second-order SQUID gradiometers with 37 mm diameter and 60 mm baseline, having magnetic field resolution of 1.2-2.8 fT/rtHz. It also includes four sets of coils for 2-D Fourier imaging with pre-polarization. The system'…
▽ More
A seven-channel system capable of performing both magnetoencephalography (MEG) and ultra-low-field magnetic resonance imaging (ULF MRI) is described. The system consists of seven second-order SQUID gradiometers with 37 mm diameter and 60 mm baseline, having magnetic field resolution of 1.2-2.8 fT/rtHz. It also includes four sets of coils for 2-D Fourier imaging with pre-polarization. The system's MEG performance was demonstrated by measurements of auditory evoked response. The system was also used to obtain a multi-channel 2-D image of a whole human hand at the measurement field of 46 microtesla with 3 by 3 mm resolution.
△ Less
Submitted 29 November, 2006;
originally announced November 2006.
-
Measurement of the 3He mass diffusion coefficient in superfluid 4He over the 0.45-0.95 K temperature range
Authors:
S. K. Lamoreaux,
G. Archibald,
P. D. Barnes,
W. T. Buttler,
D. J. Clark,
M. D. Cooper,
M. Espy,
G. L. Greene,
R. Golub,
M. E. Hayden,
C. Lei,
L. J. Marek,
J. -C. Peng,
S. Penttila
Abstract:
We have measured the mass diffusion coefficient D of 3He in superfluid 4He at temperatures lower than were previously possible. The experimental technique utilizes scintillation light produced when neutron react with 3He nuclei, and allows measurement of the 3He density integrated along the trajectory of a well-defined neutron beam. By measuring the change in 3He density near a heater as a funct…
▽ More
We have measured the mass diffusion coefficient D of 3He in superfluid 4He at temperatures lower than were previously possible. The experimental technique utilizes scintillation light produced when neutron react with 3He nuclei, and allows measurement of the 3He density integrated along the trajectory of a well-defined neutron beam. By measuring the change in 3He density near a heater as a function of applied heat current, we are able to infer values of D with 20% accuracy. At temperatures below 0.7 K and for concentrations of order 10^{-4} we find D=(2.0+2.4-1.2)T^-(6.5 -/+ 1.2) cm^2/s, in agreement with a theoretical approximation.
△ Less
Submitted 4 October, 2001;
originally announced October 2001.
-
A measurement of the absolute neutron beam polarization produced by an optically-pumped 3He spin filter
Authors:
D. R. Rich,
J. D. Bowman,
B. E. Crawford,
P. P. J. Delheij,
M. A. Espy,
T. Haseyama,
G. Jones,
C. D. Keith,
J. Knudson,
M. B. Leuschner,
A. Masaike,
Y. Masuda,
Y. Matsuda,
S. I. Penttila,
V. R. Pomeroy,
D. A. Smith,
W. M. Snow,
S. L. Stephenson,
A. K. Thompson,
V. Yuan
Abstract:
The capability of performing accurate measurements of neutron beam polarization opens a number of exciting opportunities in fundamental neutron physics and in neutron scattering. At the LANSCE pulsed neutron source we have measured the neutron beam polarization with absolute accuracy of 0.3% in the neutron energy range from 40 meV to 10 eV using an optically-pumped polarized 3He spin filter and…
▽ More
The capability of performing accurate measurements of neutron beam polarization opens a number of exciting opportunities in fundamental neutron physics and in neutron scattering. At the LANSCE pulsed neutron source we have measured the neutron beam polarization with absolute accuracy of 0.3% in the neutron energy range from 40 meV to 10 eV using an optically-pumped polarized 3He spin filter and a relative transmission measurement technique. 3He was polarized using the Rb spin-exchange method. We describe the measurement technique, present our results, and discuss some of the systematic effects associated with the method.
△ Less
Submitted 25 August, 1999;
originally announced August 1999.