-
SDF4CHD: Generative Modeling of Cardiac Anatomies with Congenital Heart Defects
Authors:
Fanwei Kong,
Sascha Stocker,
Perry S. Choi,
Michael Ma,
Daniel B. Ennis,
Alison Marsden
Abstract:
Congenital heart disease (CHD) encompasses a spectrum of cardiovascular structural abnormalities, often requiring customized treatment plans for individual patients. Computational modeling and analysis of these unique cardiac anatomies can improve diagnosis and treatment planning and may ultimately lead to improved outcomes. Deep learning (DL) methods have demonstrated the potential to enable effi…
▽ More
Congenital heart disease (CHD) encompasses a spectrum of cardiovascular structural abnormalities, often requiring customized treatment plans for individual patients. Computational modeling and analysis of these unique cardiac anatomies can improve diagnosis and treatment planning and may ultimately lead to improved outcomes. Deep learning (DL) methods have demonstrated the potential to enable efficient treatment planning by automating cardiac segmentation and mesh construction for patients with normal cardiac anatomies. However, CHDs are often rare, making it challenging to acquire sufficiently large patient cohorts for training such DL models. Generative modeling of cardiac anatomies has the potential to fill this gap via the generation of virtual cohorts; however, prior approaches were largely designed for normal anatomies and cannot readily capture the significant topological variations seen in CHD patients. Therefore, we propose a type- and shape-disentangled generative approach suitable to capture the wide spectrum of cardiac anatomies observed in different CHD types and synthesize differently shaped cardiac anatomies that preserve the unique topology for specific CHD types. Our DL approach represents generic whole heart anatomies with CHD type-specific abnormalities implicitly using signed distance fields (SDF) based on CHD type diagnosis, which conveniently captures divergent anatomical variations across different types and represents meaningful intermediate CHD states. To capture the shape-specific variations, we then learn invertible deformations to morph the learned CHD type-specific anatomies and reconstruct patient-specific shapes. Our approach has the potential to augment the image-segmentation pairs for rarer CHD types for cardiac segmentation and generate cohorts of CHD cardiac meshes for computational simulation.
△ Less
Submitted 8 November, 2023; v1 submitted 1 November, 2023;
originally announced November 2023.
-
Coil Sketching for computationally-efficient MR iterative reconstruction
Authors:
Julio A. Oscanoa,
Frank Ong,
Siddharth S. Iyer,
Zhitao Li,
Christopher M. Sandino,
Batu Ozturkler,
Daniel B. Ennis,
Mert Pilanci,
Shreyas S. Vasanawala
Abstract:
Purpose: Parallel imaging and compressed sensing reconstructions of large MRI datasets often have a prohibitive computational cost that bottlenecks clinical deployment, especially for 3D non-Cartesian acquisitions. One common approach is to reduce the number of coil channels actively used during reconstruction as in coil compression. While effective for Cartesian imaging, coil compression inherent…
▽ More
Purpose: Parallel imaging and compressed sensing reconstructions of large MRI datasets often have a prohibitive computational cost that bottlenecks clinical deployment, especially for 3D non-Cartesian acquisitions. One common approach is to reduce the number of coil channels actively used during reconstruction as in coil compression. While effective for Cartesian imaging, coil compression inherently loses signal energy, producing shading artifacts that compromise image quality for 3D non-Cartesian imaging. We propose coil sketching, a general and versatile method for computationally-efficient iterative MR image reconstruction.
Theory and Methods: We based our method on randomized sketching algorithms, a type of large-scale optimization algorithms well established in the fields of machine learning and big data analysis. We adapt the sketching theory to the MRI reconstruction problem via a structured sketching matrix that, similar to coil compression, considers high-energy virtual coils obtained from principal component analysis. But, unlike coil compression, it also considers random linear combinations of the remaining low-energy coils, effectively leveraging information from all coils.
Results: First, we performed ablation experiments to validate the sketching matrix design on both Cartesian and non-Cartesian datasets. The resulting design yielded both improved computational efficiency and preserved signal-to-noise ratio (SNR) as measured by the inverse g-factor. Then, we verified the efficacy of our approach on high-dimensional non-Cartesian 3D cones datasets, where coil sketching yielded up to three-fold faster reconstructions with equivalent image quality.
Conclusion: Coil sketching is a general and versatile reconstruction framework for computationally fast and memory-efficient reconstruction.
△ Less
Submitted 11 October, 2023; v1 submitted 10 May, 2023;
originally announced May 2023.
-
Hemodynamic Effects of Entry and Exit Tear Size in Aortic Dissection Evaluated with In Vitro Magnetic Resonance Imaging and Fluid-Structure Interaction Simulation
Authors:
Judith Zimmermann,
Kathrin Bäumler,
Michael Loecher,
Tyler E. Cork,
Alison L. Marsden,
Daniel B. Ennis,
Dominik Fleischmann
Abstract:
Understanding the complex interplay between morphologic and hemodynamic features in aortic dissection is critical for risk stratification and for the development of individualized therapy. This work evaluates the effects of entry and exit tear size on the hemodynamics in type B aortic dissection by comparing fluid-structure interaction (FSI) simulations with in vitro 4D-flow magnetic resonance ima…
▽ More
Understanding the complex interplay between morphologic and hemodynamic features in aortic dissection is critical for risk stratification and for the development of individualized therapy. This work evaluates the effects of entry and exit tear size on the hemodynamics in type B aortic dissection by comparing fluid-structure interaction (FSI) simulations with in vitro 4D-flow magnetic resonance imaging (MRI). A baseline patient-specific 3D-printed model and two variants with modified tear size (smaller entry tear, smaller exit tear) were embedded into a flow- and pressure-controlled setup to perform MRI as well as 12-point catheter-based pressure measurements. The same models defined the wall and fluid domains for FSI simulations, for which boundary conditions were matched with measured data. Results showed exceptionally well matched complex flow patterns between 4D-flow MRI and FSI simulations. Compared to the baseline model, false lumen flow volume decreased with either a smaller entry tear (-17.8 and -18.5 %, for FSI simulation and 4D-flow MRI, respectively) or smaller exit tear (-16.0 and -17.3 %). True to false lumen pressure difference (initially 11.0 and 7.9 mmHg, for FSI simulation and catheter-based pressure measurements, respectively) increased with a smaller entry tear (28.9 and 14.6 mmHg), and became negative with a smaller exit tear (-20.6 and -13.2 mmHg). This work establishes quantitative and qualitative effects of entry or exit tear size on hemodynamics in aortic dissection, with particularly notable impact observed on FL pressurization. FSI simulations demonstrate acceptable qualitative and quantitative agreement with flow imaging, supporting its deployment in clinical studies.
△ Less
Submitted 23 March, 2023;
originally announced March 2023.
-
Validation of the Reduced Unified Continuum Formulation Against In Vitro 4D-Flow MRI
Authors:
Ingrid S. Lan,
Ju Liu,
Weiguang Yang,
Judith Zimmermann,
Daniel B. Ennis,
Alison L. Marsden
Abstract:
In our recent work, we introduced the reduced unified continuum formulation for vascular fluid-structure interaction (FSI) and demonstrated enhanced solver accuracy, scalability, and performance compared to conventional approaches. We further verified the formulation against Womersley's deformable wall theory. In this study, we assessed its performance in a compliant patient-specific aortic model…
▽ More
In our recent work, we introduced the reduced unified continuum formulation for vascular fluid-structure interaction (FSI) and demonstrated enhanced solver accuracy, scalability, and performance compared to conventional approaches. We further verified the formulation against Womersley's deformable wall theory. In this study, we assessed its performance in a compliant patient-specific aortic model by leveraging 3D printing, 2D magnetic resonance imaging (MRI), and 4D-flow MRI to extract high-resolution anatomical and hemodynamic information from an in vitro flow circuit. To accurately reflect experimental conditions, we additionally enabled in-plane vascular motion at each inlet and outlet, and implemented viscoelastic external tissue support and vascular tissue prestressing. Validation of our formulation is achieved through close quantitative agreement in pressures, lumen area changes, pulse wave velocity, and early systolic velocities, as well as qualitative agreement in late systolic flow structures. Our validated suite of FSI techniques can be used to investigate vascular disease initiation, progression, and treatment at a computational cost on the same order as that of rigid-walled simulations. This study is the first to validate a cardiovascular FSI formulation against an in vitro flow circuit involving a compliant vascular phantom of complex patient-specific anatomy.
△ Less
Submitted 1 March, 2022;
originally announced March 2022.
-
Quantitative Hemodynamics in Aortic Dissection: Comparing in vitro MRI with FSI Simulation in a Compliant Model
Authors:
Judith Zimmermann,
Kathrin Baeumler,
Michael Loecher,
Tyler E. Cork,
Fikunwa O. Kolawole,
Kyle Gifford,
Alison L. Marsden,
Dominik Fleischmann,
Daniel B. Ennis
Abstract:
The analysis of quantitative hemodynamics and luminal pressure may add valuable information to aid treatment strategies and prognosis for aortic dissections. This work directly compared in vitro 4D-flow magnetic resonance imaging (MRI), catheter-based pressure measurements, and computational fluid dynamics that integrated fluid-structure interaction (CFD FSI). Experimental data was acquired with a…
▽ More
The analysis of quantitative hemodynamics and luminal pressure may add valuable information to aid treatment strategies and prognosis for aortic dissections. This work directly compared in vitro 4D-flow magnetic resonance imaging (MRI), catheter-based pressure measurements, and computational fluid dynamics that integrated fluid-structure interaction (CFD FSI). Experimental data was acquired with a compliant 3D-printed model of a type-B aortic dissection (TBAD) that was embedded into a physiologically tuned flow circuit. In vitro flow and pressure information were used to tune the CFD FSI Windkessel boundary conditions. Results showed very good overall agreement of complex flow patterns, true to false lumen flow splits, and pressure distribution. This work demonstrates feasibility of a tunable experimental setup that integrates a patient-specific compliant model and provides a test bed for exploring critical imaging and modeling parameters that ultimately may improve the prognosis for patients with aortic dissections.
△ Less
Submitted 21 April, 2021; v1 submitted 25 February, 2021;
originally announced February 2021.
-
Testing Foundations of Biological Scaling Theory Using Automated Measurements of Vascular Networks
Authors:
Mitchell G Newberry,
Daniel B Ennis,
Van M Savage
Abstract:
Scientists have long sought to understand how vascular networks supply blood and oxygen to cells throughout the body. Recent work focuses on principles that constrain how vessel size changes through branching generations from the aorta to capillaries and uses scaling exponents to quantify these changes. Prominent scaling theories predict that combinations of these exponents explain how metabolic,…
▽ More
Scientists have long sought to understand how vascular networks supply blood and oxygen to cells throughout the body. Recent work focuses on principles that constrain how vessel size changes through branching generations from the aorta to capillaries and uses scaling exponents to quantify these changes. Prominent scaling theories predict that combinations of these exponents explain how metabolic, growth, and other biological rates vary with body size. Nevertheless, direct measurements of individual vessel segments have been limited because existing techniques for measuring vasculature are invasive, time consuming, and technically difficult. We developed software that extracts the length, radius, and connectivity of in vivo vessels from contrast-enhanced 3D Magnetic Resonance Angiography. Using data from 20 human subjects, we calculated scaling exponents by four methods--two derived from local properties of branching junctions and two from whole-network properties. Although these methods are often used interchangeably in the literature, we do not find general agreement between these methods, particularly for vessel lengths. Measurements for length of vessels also diverge from theoretical values, but those for radius show stronger agreement. Our results demonstrate that vascular network models cannot ignore certain complexities of real vascular systems and indicate the need to discover new principles regarding vessel lengths.
△ Less
Submitted 9 September, 2015;
originally announced September 2015.