-
Implementing High-Order FIR Filters in FPGAs
Authors:
Philipp Födisch,
Artsiom Bryksa,
Bert Lange,
Wolfgang Enghardt,
Peter Kaever
Abstract:
Contemporary field-programmable gate arrays (FPGAs) are predestined for the application of finite impulse response (FIR) filters. Their embedded digital signal processing (DSP) blocks for multiply-accumulate operations enable efficient fixed-point computations, in cases where the filter structure is accurately mapped to the dedicated hardware architecture. This brief presents a generic systolic st…
▽ More
Contemporary field-programmable gate arrays (FPGAs) are predestined for the application of finite impulse response (FIR) filters. Their embedded digital signal processing (DSP) blocks for multiply-accumulate operations enable efficient fixed-point computations, in cases where the filter structure is accurately mapped to the dedicated hardware architecture. This brief presents a generic systolic structure for high-order FIR filters, efficiently exploiting the hardware resources of an FPGA in terms of routability and timing. Although this seems to be an easily implementable task, the synthesizing tools require an adaptation of the straightforward digital filter implementation for an optimal map**. Using the example of a symmetric FIR filter with 90 taps, we demonstrate the performance of the proposed structure with FPGAs from Xilinx and Altera. The implementation utilizes less than 1% of slice logic and runs at clock frequencies up to 526 MHz. Moreover, an enhancement of the structure ultimately provides an extended dynamic range for the quantized coefficients without the costs of additional slice logic.
△ Less
Submitted 12 October, 2016; v1 submitted 11 October, 2016;
originally announced October 2016.
-
Digital high-pass filter deconvolution by means of an infinite impulse response filter
Authors:
P. Födisch,
J. Wohsmann,
B. Lange,
J. Schönherr,
W. Enghardt,
P. Kaever
Abstract:
In the application of semiconductor detectors, the charge-sensitive amplifier is widely used in front-end electronics. The output signal is shaped by a typical exponential decay. Depending on the feedback network, this type of front-end electronics suffers from the ballistic deficit problem, or an increased rate of pulse pile-ups. Moreover, spectroscopy applications require a correction of the pul…
▽ More
In the application of semiconductor detectors, the charge-sensitive amplifier is widely used in front-end electronics. The output signal is shaped by a typical exponential decay. Depending on the feedback network, this type of front-end electronics suffers from the ballistic deficit problem, or an increased rate of pulse pile-ups. Moreover, spectroscopy applications require a correction of the pulse-height, while a shortened pulse-width is desirable for high-throughput applications. For both objectives, digital deconvolution of the exponential decay is convenient. With a general method and the signals of our custom charge-sensitive amplifier for cadmium zinc telluride detectors, we show how the transfer function of an amplifier is adapted to an infinite impulse response (IIR) filter. This paper investigates different design methods for an IIR filter in the discrete-time domain and verifies the obtained filter coefficients with respect to the equivalent continuous-time frequency response. Finally, the exponential decay is shaped to a step-like output signal that is exploited by a forward-looking pulse processing.
△ Less
Submitted 1 June, 2016; v1 submitted 29 April, 2016;
originally announced April 2016.
-
Charge-sensitive front-end electronics with operational amplifiers for CdZnTe detectors
Authors:
P. Födisch,
M. Berthel,
B. Lange,
T. Kirschke,
W. Enghardt,
P. Kaever
Abstract:
Cadmium zinc telluride (CdZnTe, CZT) radiation detectors are suitable for a variety of applications, due to their high spatial resolution and spectroscopic energy performance at room temperature. However, state-of-the-art detector systems require high-performance readout electronics. Though an application-specific integrated circuit (ASIC) is an adequate solution for the readout, requirements of h…
▽ More
Cadmium zinc telluride (CdZnTe, CZT) radiation detectors are suitable for a variety of applications, due to their high spatial resolution and spectroscopic energy performance at room temperature. However, state-of-the-art detector systems require high-performance readout electronics. Though an application-specific integrated circuit (ASIC) is an adequate solution for the readout, requirements of high dynamic range and high throughput are not available in any commercial circuit. Consequently, the present study develops the analog front-end electronics with operational amplifiers for an 8x8 pixelated CZT detector. For this purpose, we modeled an electrical equivalent circuit of the CZT detector with the associated charge-sensitive amplifier (CSA). Based on a detailed network analysis, the circuit design is completed by numerical values for various features such as ballistic deficit, charge-to-voltage gain, rise time, and noise level. A verification of the performance is carried out by synthetic detector signals and a pixel detector. The experimental results with the pixel detector assembly and a 22Na radioactive source emphasize the depth dependence of the measured energy. After pulse processing with depth correction based on the fit of the weighting potential, the energy resolution is 2.2% (FWHM) for the 511 keV photopeak.
△ Less
Submitted 19 August, 2016; v1 submitted 16 March, 2016;
originally announced March 2016.
-
A synchronous Gigabit Ethernet protocol stack for high-throughput UDP/IP applications
Authors:
P. Födisch,
B. Lange,
J. Sandmann,
A. Büchner,
W. Enghardt,
P. Kaever
Abstract:
State of the art detector readout electronics require high-throughput data acquisition (DAQ) systems. In many applications, e. g. for medical imaging, the front-end electronics are set up as separate modules in a distributed DAQ. A standardized interface between the modules and a central data unit is essential. The requirements on such an interface are varied, but demand almost always a high throu…
▽ More
State of the art detector readout electronics require high-throughput data acquisition (DAQ) systems. In many applications, e. g. for medical imaging, the front-end electronics are set up as separate modules in a distributed DAQ. A standardized interface between the modules and a central data unit is essential. The requirements on such an interface are varied, but demand almost always a high throughput of data. Beyond this challenge, a Gigabit Ethernet interface is predestined for the broad requirements of Systems-on-a-Chip (SoC) up to large-scale DAQ systems. We have implemented an embedded protocol stack for a Field Programmable Gate Array (FPGA) capable of high-throughput data transmission and clock synchronization. A versatile stack architecture for the User Datagram Protocol (UDP) and Internet Control Message Protocol (ICMP) over Internet Protocol (IP) such as Address Resolution Protocol (ARP) as well as Precision Time Protocol (PTP) is presented. With a point-to-point connection to a host in a MicroTCA system we achieved the theoretical maximum data throughput limited by UDP both for 1000BASE-T and 1000BASE-KX links. Furthermore, we show that the random jitter of a synchronous clock over a 1000BASE-T link for a PTP application is below 60 ps.
△ Less
Submitted 23 November, 2015; v1 submitted 5 October, 2015;
originally announced October 2015.
-
Phi decay: a relevant source for K- production at SIS energies?
Authors:
The HADES Collaboration,
G. Agakishiev,
A. Balanda,
B. Bannier,
R. Bassini,
D. Belver,
A. V. Belyaev,
A. Blanco,
M. Boehmer,
J. L. Boyard,
P. Braun-Munzinger,
P. Cabanelas,
E. Castro,
S. Chernenko,
T. Christ,
M. Destefanis,
J. Diaz,
F. Dohrmann,
A. Dybczak,
T. Eberl,
W. Enghardt,
L. Fabbietti,
O. V. Fateev,
P. Finocchiaro,
P. Fonte
, et al. (88 additional authors not shown)
Abstract:
We present phase space distributions and multiplicities of K+, K- and phi mesons produced in Ar+KCl reactions at a kinetic beam energy of 1.756 AGeV and measured with the HADES spectrometer. The inverse slope parameters and yields of kaons supplement the systematics of previous measurements. The percentage of K- mesons coming fromphi decay is found to be 18+- 7%.
We present phase space distributions and multiplicities of K+, K- and phi mesons produced in Ar+KCl reactions at a kinetic beam energy of 1.756 AGeV and measured with the HADES spectrometer. The inverse slope parameters and yields of kaons supplement the systematics of previous measurements. The percentage of K- mesons coming fromphi decay is found to be 18+- 7%.
△ Less
Submitted 19 February, 2009;
originally announced February 2009.
-
The High-Acceptance Dielectron Spectrometer HADES
Authors:
The HADES Collaboration,
G. Agakishiev,
A. Balanda,
B. Bannier,
R. Bassini,
D. Belver,
A. V. Belyaev,
A. Blanco,
M. Boehmer,
J. L. Boyard,
P. Braun-Munzinger,
P. Cabanelas,
E. Castro,
S. Chernenko,
T. Christ,
M. Destefanis,
J. Diaz,
F. Dohrmann,
A. Dybczak,
T. Eberl,
W. Enghardt,
L. Fabbietti,
O. V. Fateev,
P. Finocchiaro,
P. Fonte
, et al. (88 additional authors not shown)
Abstract:
HADES is a versatile magnetic spectrometer aimed at studying dielectron production in pion, proton and heavy-ion induced collisions. Its main features include a ring imaging gas Cherenkov detector for electron-hadron discrimination, a tracking system consisting of a set of 6 superconducting coils producing a toroidal field and drift chambers and a multiplicity and electron trigger array for addi…
▽ More
HADES is a versatile magnetic spectrometer aimed at studying dielectron production in pion, proton and heavy-ion induced collisions. Its main features include a ring imaging gas Cherenkov detector for electron-hadron discrimination, a tracking system consisting of a set of 6 superconducting coils producing a toroidal field and drift chambers and a multiplicity and electron trigger array for additional electron-hadron discrimination and event characterization. A two-stage trigger system enhances events containing electrons. The physics program is focused on the investigation of hadron properties in nuclei and in the hot and dense hadronic matter. The detector system is characterized by an 85% azimuthal coverage over a polar angle interval from 18 to 85 degree, a single electron efficiency of 50% and a vector meson mass resolution of 2.5%. Identification of pions, kaons and protons is achieved combining time-of-flight and energy loss measurements over a large momentum range. This paper describes the main features and the performance of the detector system.
△ Less
Submitted 9 March, 2009; v1 submitted 19 February, 2009;
originally announced February 2009.