-
Resolving non-equilibrium shape variations amongst millions of gold nanoparticles
Authors:
Zhou Shen,
Salah Awel,
Anton Barty,
Richard Bean,
Johan Bielecki,
Martin Bergemann,
Benedikt J. Daurer,
Tomas Ekeberg,
Armando D. Estillore,
Hans Fangohr,
Klaus Giewekemeyer,
Mark S. Hunter,
Mikhail Karnevskiy,
Richard A. Kirian,
Henry Kirkwood,
Yoonhee Kim,
Jayanath Koliyadu,
Holger Lange,
Romain Letrun,
Jannik Lübke,
Abhishek Mall,
Thomas Michelat,
Andrew J. Morgan,
Nils Roth,
Amit K. Samanta
, et al. (14 additional authors not shown)
Abstract:
Nanoparticles, exhibiting functionally relevant structural heterogeneity, are at the forefront of cutting-edge research. Now, high-throughput single-particle imaging (SPI) with x-ray free-electron lasers (XFELs) creates unprecedented opportunities for recovering the shape distributions of millions of particles that exhibit functionally relevant structural heterogeneity. To realize this potential,…
▽ More
Nanoparticles, exhibiting functionally relevant structural heterogeneity, are at the forefront of cutting-edge research. Now, high-throughput single-particle imaging (SPI) with x-ray free-electron lasers (XFELs) creates unprecedented opportunities for recovering the shape distributions of millions of particles that exhibit functionally relevant structural heterogeneity. To realize this potential, three challenges have to be overcome: (1) simultaneous parametrization of structural variability in real and reciprocal spaces; (2) efficiently inferring the latent parameters of each SPI measurement; (3) scaling up comparisons between $10^5$ structural models and $10^6$ XFEL-SPI measurements. Here, we describe how we overcame these three challenges to resolve the non-equilibrium shape distributions within millions of gold nanoparticles imaged at the European XFEL. These shape distributions allowed us to quantify the degree of asymmetry in these particles, discover a relatively stable `shape envelope' amongst nanoparticles, discern finite-size effects related to shape-controlling surfactants, and extrapolate nanoparticles' shapes to their idealized thermodynamic limit. Ultimately, these demonstrations show that XFEL SPI can help transform nanoparticle shape characterization from anecdotally interesting to statistically meaningful.
△ Less
Submitted 9 January, 2024;
originally announced January 2024.
-
3D-Printed Sheet Jet for Stable Megahertz Liquid Sample Delivery at X-ray Free Electron Lasers
Authors:
Patrick E. Konold,
Tong You,
Johan Bielecki,
Joana Valerio,
Marco Kloos,
Daniel Westphal,
Alfredo Bellisario,
Tej Varma,
August Wolter,
Jayanath C. P. Koliyadu,
Faisal H. M. Koua,
Romain Letrun,
Adam Round,
Tokushi Sato,
Petra Mésźaros,
Leonardo Monrroy,
Jennifer Mutisya,
Szabolcs Bódizs,
Taru Larkiala,
Amke Nimmrich,
Roberto Alvarez,
Richard Bean,
Tomas Ekeberg,
Richard A. Kirian,
Sebastian Westenhoff
, et al. (1 additional authors not shown)
Abstract:
X-ray Free Electron Lasers (XFELs) can probe chemical and biological reactions as they unfold with unprecedented spatial and temporal resolution. A principal challenge in this pursuit is the delivery of samples to the X-ray interaction point in a way that produces data of the highest possible quality and efficiency. This is hampered by constraints posed by the light source and operation within a b…
▽ More
X-ray Free Electron Lasers (XFELs) can probe chemical and biological reactions as they unfold with unprecedented spatial and temporal resolution. A principal challenge in this pursuit is the delivery of samples to the X-ray interaction point in a way that produces data of the highest possible quality and efficiency. This is hampered by constraints posed by the light source and operation within a beamline environment. For liquid samples, the solution typically involves a high-speed liquid jet, capable of kee** up with the rate of X-ray pulses. However, conventional jets are not ideal because of radiation-induced explosions of the jet, as well as their cylindrical geometry combined with the X-ray pointing instability of many beamlines causes the interaction volume to differ for every pulse. This complicates data analysis and contributes to measurement errors. An alternative geometry is a liquid sheet jet which, with its constant thickness over large areas, eliminates the X-ray pointing related problems. Since liquid sheets can be made very thin, the radiation-induced explosion is reduced, boosting their stability. They are especially attractive for experiments which benefit from small interaction volumes such as fluctuation X-ray scattering and several types of spectroscopy. Although they have seen increasing use for soft X-ray applications in recent years, there has not yet been wide-scale adoption at XFELs. Here, we demonstrate liquid sheet jet sample injection at the European XFEL. We evaluate several aspects of its performance relative to a conventional liquid jet including thickness profile, stability, and radiation-induced explosion dynamics at high repetition rates. The sheet jet exhibits superior performance across these critical experimental parameters. Its minute thickness also suggests ultrafast single-particle solution scattering is a possibility.
△ Less
Submitted 13 June, 2023;
originally announced June 2023.
-
Unsupervised learning approaches to characterize heterogeneous samples using X-ray single particle imaging
Authors:
Yulong Zhuang,
Salah Awel,
Anton Barty,
Richard Bean,
Johan Bielecki,
Martin Bergemann,
Benedikt J. Daurer,
Tomas Ekeberg,
Armando D. Estillore,
Hans Fangohr,
Klaus Giewekemeyer,
Mark S. Hunter,
Mikhail Karnevskiy,
Richard A. Kirian,
Henry Kirkwood,
Yoonhee Kim,
Jayanath Koliyadu,
Holger Lange,
Romain Letrun,
Jannik Lübke,
Abhishek Mall,
Thomas Michelat,
Andrew J. Morgan,
Nils Roth,
Amit K. Samanta
, et al. (17 additional authors not shown)
Abstract:
One of the outstanding analytical problems in X-ray single particle imaging (SPI) is the classification of structural heterogeneity, which is especially difficult given the low signal-to-noise ratios of individual patterns and that even identical objects can yield patterns that vary greatly when orientation is taken into consideration. We propose two methods which explicitly account for this orien…
▽ More
One of the outstanding analytical problems in X-ray single particle imaging (SPI) is the classification of structural heterogeneity, which is especially difficult given the low signal-to-noise ratios of individual patterns and that even identical objects can yield patterns that vary greatly when orientation is taken into consideration. We propose two methods which explicitly account for this orientation-induced variation and can robustly determine the structural landscape of a sample ensemble. The first, termed common-line principal component analysis (PCA) provides a rough classification which is essentially parameter-free and can be run automatically on any SPI dataset. The second method, utilizing variation auto-encoders (VAEs) can generate 3D structures of the objects at any point in the structural landscape. We implement both these methods in combination with the noise-tolerant expand-maximize-compress (EMC) algorithm and demonstrate its utility by applying it to an experimental dataset from gold nanoparticles with only a few thousand photons per pattern and recover both discrete structural classes as well as continuous deformations. These developments diverge from previous approaches of extracting reproducible subsets of patterns from a dataset and open up the possibility to move beyond studying homogeneous sample sets and study open questions on topics such as nanocrystal growth and dynamics as well as phase transitions which have not been externally triggered.
△ Less
Submitted 13 September, 2021;
originally announced September 2021.
-
Ptychographic wavefront characterisation for single-particle imaging at X-ray lasers
Authors:
Benedikt J. Daurer,
Simone Sala,
Max F. Hantke,
Hemanth K. N. Reddy,
Johan Bielecki,
Zhou Shen,
Carl Nettleblad,
Martin Svenda,
Tomas Ekeberg,
Gabriella A. Carini,
Philip Hart,
Timur Osipov,
Andrew Aquila,
N. Duane Loh,
Filipe R. N. C. Maia,
Pierre Thibault
Abstract:
A well-characterised wavefront is important for many X-ray free-electron laser (XFEL) experiments, especially for single-particle imaging (SPI), where individual bio-molecules randomly sample a nanometer-region of highly-focused femtosecond pulses. We demonstrate high-resolution multiple-plane wavefront imaging of an ensemble of XFEL pulses, focused by Kirkpatrick-Baez (KB) mirrors, based on mixed…
▽ More
A well-characterised wavefront is important for many X-ray free-electron laser (XFEL) experiments, especially for single-particle imaging (SPI), where individual bio-molecules randomly sample a nanometer-region of highly-focused femtosecond pulses. We demonstrate high-resolution multiple-plane wavefront imaging of an ensemble of XFEL pulses, focused by Kirkpatrick-Baez (KB) mirrors, based on mixed-state ptychography, an approach letting us infer and reduce experimental sources of instability. From the recovered wavefront profiles, we show that while local photon fluence correction is crucial and possible for SPI, a small diversity of phase-tilts likely has no impact. Our detailed characterisation will aid interpretation of data from past and future SPI experiments, and provides a basis for further improvements to experimental design and reconstruction algorithms.
△ Less
Submitted 26 December, 2020;
originally announced December 2020.
-
3D diffractive imaging of nanoparticle ensembles using an X-ray laser
Authors:
Kartik Ayyer,
P. Lourdu Xavier,
Johan Bielecki,
Zhou Shen,
Benedikt J. Daurer,
Amit K. Samanta,
Salah Awel,
Richard Bean,
Anton Barty,
Tomas Ekeberg,
Armando D. Estillore,
Klaus Giewekemeyer,
Mark S. Hunter,
Richard A. Kirian,
Henry Kirkwood,
Yoonhee Kim,
Jayanath Koliyadu,
Holger Lange,
Romain Letruin,
Jannik Lübke,
Andrew J. Morgan,
Nils Roth,
Tokushi Sato,
Marcin Sikorski,
Florian Schulz
, et al. (12 additional authors not shown)
Abstract:
We report the 3D structure determination of gold nanoparticles (AuNPs) by X-ray single particle imaging (SPI). Around 10 million diffraction patterns from gold nanoparticles were measured in less than 100 hours of beam time, more than 100 times the amount of data in any single prior SPI experiment, using the new capabilities of the European X-ray free electron laser which allow measurements of 150…
▽ More
We report the 3D structure determination of gold nanoparticles (AuNPs) by X-ray single particle imaging (SPI). Around 10 million diffraction patterns from gold nanoparticles were measured in less than 100 hours of beam time, more than 100 times the amount of data in any single prior SPI experiment, using the new capabilities of the European X-ray free electron laser which allow measurements of 1500 frames per second. A classification and structural sorting method was developed to disentangle the heterogeneity of the particles and to obtain a resolution of better than 3 nm. With these new experimental and analytical developments, we have entered a new era for the SPI method and the path towards close-to-atomic resolution imaging of biomolecules is apparent.
△ Less
Submitted 17 July, 2020;
originally announced July 2020.
-
Megahertz single-particle imaging at the European XFEL
Authors:
Egor Sobolev,
Serguey Zolotarev,
Klaus Giewekemeyer,
Johan Bielecki,
Kenta Okamoto,
Hemanth K. N. Reddy,
Jakob Andreasson,
Kartik Ayyer,
Imrich Barak,
Sadia Bari,
Anton Barty,
Richard Bean,
Sergey Bobkov,
Henry N. Chapman,
Grzegorz Chojnowski,
Benedikt J. Daurer,
Katerina Dörner,
Tomas Ekeberg,
Leonie Flückiger,
Oxana Galzitskaya,
Luca Gelisio,
Steffen Hauf,
Brenda G. Hogue,
Daniel A. Horke,
Ahmad Hosseinizadeh
, et al. (38 additional authors not shown)
Abstract:
The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European XFEL will soon provide 27,000 pulses per second, more than two orders of magnitude more than any other XFEL. The increased pulse rate is a key enabling factor for…
▽ More
The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European XFEL will soon provide 27,000 pulses per second, more than two orders of magnitude more than any other XFEL. The increased pulse rate is a key enabling factor for single-particle X-ray diffractive imaging, which relies on averaging the weak diffraction signal from single biological particles. Taking full advantage of this new capability requires that all experimental steps, from sample preparation and delivery to the acquisition of diffraction patterns, are compatible with the increased pulse repetition rate. Here, we show that single-particle imaging can be performed using X-ray pulses at megahertz repetition rates. The obtained results pave the way towards exploiting high repetition-rate X-ray free-electron lasers for single-particle imaging at their full repetition rate.
△ Less
Submitted 14 December, 2019;
originally announced December 2019.
-
Femtosecond X-ray Fourier holography imaging of free-flying nanoparticles
Authors:
Tais Gorkhover,
Anatoli Ulmer,
Ken Ferguson,
Max Bucher,
Filipe Maia,
Johan Bielecki,
Tomas Ekeberg,
Max F. Hantke,
Benedikt J. Daurer,
Carl Nettelblad,
Jakob Andreasson,
Anton Barty,
Petr Bruza,
Sebastian Carron,
Dirk Hasse,
Jacek Krzywinski,
Daniel S. D. Larsson,
Andrew Morgan,
Kerstin Muehlig,
Maria Mueller,
Kenta Okamoto,
Alberto Pietrini,
Daniela Rupp,
Mario Sauppe,
Gijs van der Schot
, et al. (13 additional authors not shown)
Abstract:
Ultrafast X-ray imaging provides high resolution information on individual fragile specimens such as aerosols, metastable particles, superfluid quantum systems and live biospecimen, which is inaccessible with conventional imaging techniques. Coherent X-ray diffractive imaging, however, suffers from intrinsic loss of phase, and therefore structure recovery is often complicated and not always unique…
▽ More
Ultrafast X-ray imaging provides high resolution information on individual fragile specimens such as aerosols, metastable particles, superfluid quantum systems and live biospecimen, which is inaccessible with conventional imaging techniques. Coherent X-ray diffractive imaging, however, suffers from intrinsic loss of phase, and therefore structure recovery is often complicated and not always uniquely-defined. Here, we introduce the method of in-flight holography, where we use nanoclusters as reference X-ray scatterers in order to encode relative phase information into diffraction patterns of a virus. The resulting hologram contains an unambiguous three-dimensional map of a virus and two nanoclusters with the highest lat- eral resolution so far achieved via single shot X-ray holography. Our approach unlocks the benefits of holography for ultrafast X-ray imaging of nanoscale, non-periodic systems and paves the way to direct observation of complex electron dynamics down to the attosecond time scale.
△ Less
Submitted 9 August, 2017; v1 submitted 28 July, 2017;
originally announced July 2017.
-
Machine learning for ultrafast X-ray diffraction patterns on large-scale GPU clusters
Authors:
Tomas Ekeberg,
Stefan Engblom,
**g Liu
Abstract:
The classical method of determining the atomic structure of complex molecules by analyzing diffraction patterns is currently undergoing drastic developments. Modern techniques for producing extremely bright and coherent X-ray lasers allow a beam of streaming particles to be intercepted and hit by an ultrashort high energy X-ray beam. Through machine learning methods the data thus collected can be…
▽ More
The classical method of determining the atomic structure of complex molecules by analyzing diffraction patterns is currently undergoing drastic developments. Modern techniques for producing extremely bright and coherent X-ray lasers allow a beam of streaming particles to be intercepted and hit by an ultrashort high energy X-ray beam. Through machine learning methods the data thus collected can be transformed into a three-dimensional volumetric intensity map of the particle itself. The computational complexity associated with this problem is very high such that clusters of data parallel accelerators are required.
We have implemented a distributed and highly efficient algorithm for inversion of large collections of diffraction patterns targeting clusters of hundreds of GPUs. With the expected enormous amount of diffraction data to be produced in the foreseeable future, this is the required scale to approach real time processing of data at the beam site. Using both real and synthetic data we look at the scaling properties of the application and discuss the overall computational viability of this exciting and novel imaging technique.
△ Less
Submitted 16 December, 2014; v1 submitted 11 September, 2014;
originally announced September 2014.
-
Cryptotomography: reconstructing 3D Fourier intensities from randomly oriented single-shot diffraction patterns
Authors:
N. D. Loh,
M. Bogan,
V. Elser,
A. Barty,
S. Boutet,
S. Bajt,
J. Hajdu,
T. Ekeberg,
F. R. N. C. Maia,
J. Schulz,
M. M. Seibert,
B. Iwan,
N. Timneanu,
S. Marchesini,
I. Schlichting,
R. L. Shoeman,
L. Lomb,
M. Frank,
M. Liang,
H. N. Chapman
Abstract:
We reconstructed the 3D Fourier intensity distribution of mono-disperse prolate nano-particles using single-shot 2D coherent diffraction patterns collected at DESY's FLASH facility when a bright, coherent, ultrafast X-ray pulse intercepted individual particles of random, unmeasured orientations. This first experimental demonstration of cryptotomography extended the Expansion-Maximization-Compres…
▽ More
We reconstructed the 3D Fourier intensity distribution of mono-disperse prolate nano-particles using single-shot 2D coherent diffraction patterns collected at DESY's FLASH facility when a bright, coherent, ultrafast X-ray pulse intercepted individual particles of random, unmeasured orientations. This first experimental demonstration of cryptotomography extended the Expansion-Maximization-Compression (EMC) framework to accommodate unmeasured fluctuations in photon fluence and loss of data due to saturation or background scatter. This work is an important step towards realizing single-shot diffraction imaging of single biomolecules.
△ Less
Submitted 5 April, 2010; v1 submitted 3 March, 2010;
originally announced March 2010.
-
PoGOLite - A High Sensitivity Balloon-Borne Soft Gamma-ray Polarimeter
Authors:
Tuneyoshi Kamae,
Viktor Andersson,
Makoto Arimoto,
Magnus Axelsson,
Cecilia Marini Bettolo,
Claes-Ingvar Björnsson,
Gilles Bogaert,
Per Carlson,
William Craig,
Tomas Ekeberg,
Olle Engdegård,
Yasushi Fukazawa,
Shuichi Gunji,
Linnea Hjalmarsdotter,
Bianca Iwan,
Yoshikazu Kanai,
Jun Kataoka,
Nobuyuki Kawai,
Jaroslav Kazejev,
Mózsi Kiss,
Wlodzimierz Klamra,
Stefan Larsson,
Grzegorz Madejski,
Tsunefumi Mizuno,
Johnny Ng
, et al. (14 additional authors not shown)
Abstract:
We describe a new balloon-borne instrument (PoGOLite) capable of detecting 10% polarisation from 200mCrab point-like sources between 25 and 80keV in one 6 hour flight. Polarisation measurements in the soft gamma-ray band are expected to provide a powerful probe into high-energy emission mechanisms as well as the distribution of magnetic fields, radiation fields and interstellar matter. At presen…
▽ More
We describe a new balloon-borne instrument (PoGOLite) capable of detecting 10% polarisation from 200mCrab point-like sources between 25 and 80keV in one 6 hour flight. Polarisation measurements in the soft gamma-ray band are expected to provide a powerful probe into high-energy emission mechanisms as well as the distribution of magnetic fields, radiation fields and interstellar matter. At present, only exploratory polarisation measurements have been carried out in the soft gamma-ray band. Reduction of the large background produced by cosmic-ray particles has been the biggest challenge. PoGOLite uses Compton scattering and photo-absorption in an array of 217 well-type phoswich detector cells made of plastic and BGO scintillators surrounded by a BGO anticoincidence shield and a thick polyethylene neutron shield. The narrow FOV (1.25msr) obtained with well-type phoswich detector technology and the use of thick background shields enhance the detected S/N ratio. Event selections based on recorded phototube waveforms and Compton kinematics reduce the background to that expected for a 40-100mCrab source between 25 and 50keV. A 6 hour observation on the Crab will differentiate between the Polar Cap/Slot Gap, Outer Gap, and Caustic models with greater than 5 sigma; and also cleanly identify the Compton reflection component in the Cygnus X-1 hard state. The first flight is planned for 2010 and long-duration flights from Sweden to Northern Canada are foreseen thereafter.
△ Less
Submitted 21 April, 2008; v1 submitted 9 September, 2007;
originally announced September 2007.