-
The Three-Dipole Kicker Injection Scheme for the ALS-U Accumulator Ring
Authors:
M. Ehrlichman,
T. Hellert,
S. C. Leemann,
G. Penn,
C. Steier,
C. Sun,
M. Venturini,
D. Wang
Abstract:
The ALS-U light source will implement on-axis single-train swap-out injection employing an accumulator between the booster and storage rings. The accumulator ring design is a twelve period triple-bend achromat that will be installed along the inner circumference of the storage-ring tunnel. A non-conventional injection scheme will be utilized for top-off off-axis injection from the booster into the…
▽ More
The ALS-U light source will implement on-axis single-train swap-out injection employing an accumulator between the booster and storage rings. The accumulator ring design is a twelve period triple-bend achromat that will be installed along the inner circumference of the storage-ring tunnel. A non-conventional injection scheme will be utilized for top-off off-axis injection from the booster into the accumulator ring meant to accommodate a large $\sim 300$~nm emittance beam into a vacuum-chamber with a limiting horizontal aperture radius as small as $8$ mm. The scheme incorporates three dipole kickers distributed over three sectors, with two kickers perturbing the stored beam and the third affecting both the stored and the injected beam trajectories. This paper describes this ``3DK'' injection scheme and how it fits the accumulator ring's particular requirements. We describe the design and optimization process, and how we evaluated its fitness as a solution for booster-to-accumulator ring injection.
△ Less
Submitted 15 June, 2021;
originally announced June 2021.
-
A Genetic Algorithm for Chromaticity Correction in Diffraction Limited Storage Rings
Authors:
M. P. Ehrlichman
Abstract:
A multi-objective genetic algorithm is developed for optimizing nonlinearities in diffraction limited storage rings. This algorithm determines sextupole and octupole strengths for chromaticity correction that deliver optimized dynamic aperture and beam lifetime. The algorithm makes use of dominance constraints to breed desirable properties into the early generations. The momentum aperture is optim…
▽ More
A multi-objective genetic algorithm is developed for optimizing nonlinearities in diffraction limited storage rings. This algorithm determines sextupole and octupole strengths for chromaticity correction that deliver optimized dynamic aperture and beam lifetime. The algorithm makes use of dominance constraints to breed desirable properties into the early generations. The momentum aperture is optimized indirectly by constraining the chromatic tune footprint and optimizing the off-energy dynamic aperture. The result is an effective and computationally efficient technique for correcting chromaticity in a storage ring while maintaining optimal dynamic aperture and beam lifetime. This framework was developed for the Swiss Light Source (SLS) upgrade project.
△ Less
Submitted 15 April, 2016; v1 submitted 8 March, 2016;
originally announced March 2016.
-
Design and performance of coded aperture optical elements for the CESR-TA x-ray beam size monitor
Authors:
J. P. Alexander,
A. Chatterjee,
C. Conolly,
E. Edwards,
M. P. Ehrlichman,
J. W. Flanagan,
E. Fontes,
B. K. Heltsley,
A. Lyndaker,
D. P. Peterson,
N. T. Rider,
D. L. Rubin,
R. Seeley,
J. Shanks
Abstract:
We describe the design and performance of optical elements for an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring. The device can measure vertical beam sizes of $10-100~μ$m on a turn-by-turn, bunch-by-bunch basis at $e^\pm$ beam energies of $\sim2-5~$GeV. X-rays produced by a hard-bend magnet pass through a single- or multiple-slit (coded a…
▽ More
We describe the design and performance of optical elements for an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring. The device can measure vertical beam sizes of $10-100~μ$m on a turn-by-turn, bunch-by-bunch basis at $e^\pm$ beam energies of $\sim2-5~$GeV. X-rays produced by a hard-bend magnet pass through a single- or multiple-slit (coded aperture) optical element onto a detector. The coded aperture slit pattern and thickness of masking material forming that pattern can both be tuned for optimal resolving power. We describe several such optical elements and show how well predictions of simple models track measured performances.
△ Less
Submitted 14 August, 2014;
originally announced August 2014.
-
Vertical beam size measurement in the CESR-TA $e^+e^-$ storage ring using x-rays from synchrotron radiation
Authors:
J. P. Alexander,
A. Chatterjee,
C. Conolly,
E. Edwards,
M. P. Ehrlichman,
E. Fontes,
B. K. Heltsley,
W. Hopkins,
A. Lyndaker,
D. P. Peterson,
N. T. Rider,
D. L. Rubin,
J. Savino,
R. Seeley,
J. Shanks,
J. W. Flanagan
Abstract:
We describe the construction and operation of an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring using synchrotron radiation. The device can measure vertical beam sizes of $10-100~μ$m on a turn-by-turn, bunch-by-bunch basis at $e^\pm$ beam energies of $\sim2~$GeV. At such beam energies the xBSM images x-rays of $ε\approx$1-10$~$keV (…
▽ More
We describe the construction and operation of an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring using synchrotron radiation. The device can measure vertical beam sizes of $10-100~μ$m on a turn-by-turn, bunch-by-bunch basis at $e^\pm$ beam energies of $\sim2~$GeV. At such beam energies the xBSM images x-rays of $ε\approx$1-10$~$keV ($λ\approx 0.1-1$ nm) that emerge from a hard-bend magnet through a single- or multiple-slit (coded aperture) optical element onto an array of 32 InGaAs photodiodes with 50$~μ$m pitch. Beamlines and detectors are entirely in-vacuum, enabling single-shot beam size measurement down to below 0.1$~$mA ($2.5\times10^9$ particles) per bunch and inter-bunch spacing of as little as 4$~$ns. At $E_{\rm b}=2.1 $GeV, systematic precision of $\sim 1~μ$m is achieved for a beam size of $\sim12~μ$m; this is expected to scale as $\propto 1/σ_{\rm b}$ and $\propto 1/E_{\rm b}$. Achieving this precision requires comprehensive alignment and calibration of the detector, optical elements, and x-ray beam. Data from the xBSM have been used to extract characteristics of beam oscillations on long and short timescales, and to make detailed studies of low-emittance tuning, intra-beam scattering, electron cloud effects, and multi-bunch instabilities.
△ Less
Submitted 3 March, 2014; v1 submitted 26 November, 2013;
originally announced November 2013.
-
Measurement and Compensation of Horizontal Crabbing at the Cornell Electron Storage Ring Test Accelerator
Authors:
M. P. Ehrlichman,
A. Chatterjee,
W. Hartung,
B. Heltsley,
D. P. Peterson,
N. Rider,
D. Rubin,
D. Sagan,
J. P. Shanks,
S. T. Wang
Abstract:
In storage rings, horizontal dispersion in the rf cavities introduces horizontal-longitudinal (xz) coupling, contributing to beam tilt in the xz plane. This coupling can be characterized by a "crabbing" dispersion term ζa that appears in the normal mode decomposition of the 1-turn transfer matrix. ζa is proportional to the rf cavity voltage and the horizontal dispersion in the cavity. We report ex…
▽ More
In storage rings, horizontal dispersion in the rf cavities introduces horizontal-longitudinal (xz) coupling, contributing to beam tilt in the xz plane. This coupling can be characterized by a "crabbing" dispersion term ζa that appears in the normal mode decomposition of the 1-turn transfer matrix. ζa is proportional to the rf cavity voltage and the horizontal dispersion in the cavity. We report experiments at the Cornell Electron Storage Ring Test Accelerator (CesrTA) where xz coupling was explored using three lattices with distinct crabbing properties. We characterize the xz coupling for each case by measuring the horizontal projection of the beam with a beam size monitor. The three lattice configurations correspond to a) 16 mrad xz tilt at the beam size monitor source point, b) compensation of the ζa introduced by one of two pairs of RF cavities with the second, and c) zero dispersion in RF cavities, eliminating ζa entirely. Additionally, intrabeam scattering (IBS) is evident in our measurements of beam size vs. rf voltage.
△ Less
Submitted 13 March, 2014; v1 submitted 7 November, 2013;
originally announced November 2013.
-
Intrabeam Scattering Studies at CesrTA
Authors:
M. P. Ehrlichman,
W. Hartung,
B. Heltsley,
D. P. Peterson,
N. Rider,
D. Rubin,
D. Sagan,
J. Shanks,
S. T. Wang,
R. Campbell,
R. Holtzapple
Abstract:
Intrabeam scattering (IBS) limits the emittance and single-bunch current that can be achieved in electron or positron storage ring colliders, dam** rings, and light sources. Much theoretical work on IBS exists, and while the theories have been validated in hadron and ion machines, the presence of strong dam** makes IBS in lepton machines a different phenomenon. We present the results of measur…
▽ More
Intrabeam scattering (IBS) limits the emittance and single-bunch current that can be achieved in electron or positron storage ring colliders, dam** rings, and light sources. Much theoretical work on IBS exists, and while the theories have been validated in hadron and ion machines, the presence of strong dam** makes IBS in lepton machines a different phenomenon. We present the results of measurements at CesrTA of IBS dominated beams, and compare the data with theory. The beams we study have parameters typical of those specified for the next generation of wiggler dominated storage rings: low emittance, small bunch length, and few GeV energy. Our measurements are in good agreement with IBS theory, provided a tail-cut procedure is applied.
△ Less
Submitted 14 October, 2013; v1 submitted 31 July, 2013;
originally announced August 2013.