Skip to main content

Showing 1–4 of 4 results for author: Edwards, B N V

.
  1. arXiv:2101.03686  [pdf, other

    physics.ins-det hep-ex physics.app-ph

    The Electric Field Dependence of Single Electron Emission in the PIXeY Two-Phase Xenon Detector

    Authors: E. Bodnia, E. P. Bernard, A. Biekert, E. M. Boulton, S. B. Cahn, N. Destefano, B. N. V. Edwards, M. Gai, M. Horn, N. A. Larsen, Q. Riffard, B. Tennyson, V. Velan, C. Wahl, D. N. McKinsey

    Abstract: Dual phase xenon detectors are widely used in experimental searches for galactic darkmatter particles. The origin of single electron backgrounds following prompt scintillation and proportional scintillation signals in these detectors is not fully understood, although there has been progress in recent years. In this paper, we describe single electron backgrounds in ${}^{83m}Kr$ calibration events a… ▽ More

    Submitted 16 December, 2021; v1 submitted 10 January, 2021; originally announced January 2021.

    Comments: accepted for publication in JINST

    Journal ref: 2021 JINST 16 P12015

  2. Analysis of $^{83m}$Kr Prompt Scintillation Signals in the PIXeY Detector

    Authors: A. G. Singh, A. Biekert, E. Bernard, E. M. Boulton, S. B. Cahn, N. Destefano, B. N. V. Edwards, M. Gai, M. Horn, N. Larsen, B. Tennyson, Q. Riffard, V. Velan, C. Wahl, D. N. McKinsey

    Abstract: Prompt scintillation signals from $^{83m}$Kr calibration sources are a useful metric to calibrate the spatial variation of light collection efficiency and electric field magnitude of a two phase liquid-gas xenon time projection chamber. Because $^{83m}$Kr decays in two steps, there are two prompt scintillation pulses for each calibration event, denoted S1a and S1b. We study the ratio of S1b to S1a… ▽ More

    Submitted 9 December, 2019; v1 submitted 10 November, 2019; originally announced November 2019.

    Comments: Version edits: corrected typos and references, revised values presented in section 5.1, analysis conclusion is unchanged

  3. arXiv:1710.11032  [pdf, other

    physics.ins-det hep-ex

    Extraction efficiency of drifting electrons in a two-phase xenon time projection chamber

    Authors: B. N. V. Edwards, E. Bernard, E. M. Boulton, N. Destefano, M. Gai, M. Horn, N. Larsen, B. Tennyson, L. Tvrznikova, C. Wahl, D. N. McKinsey

    Abstract: We present a measurement of the extraction efficiency of quasi-free electrons from the liquid into the gas phase in a two-phase xenon time-projection chamber. The measurements span a range of electric fields from 2.4 to 7.1 kV/cm in the liquid xenon, corresponding to 4.5 to 13.1 kV/cm in the gaseous xenon. Extraction efficiency continues to increase at the highest extraction fields, implying that… ▽ More

    Submitted 7 January, 2018; v1 submitted 30 October, 2017; originally announced October 2017.

  4. Calibration of a two-phase xenon time projection chamber with a $^{37}$Ar source

    Authors: E. M. Boulton, E. Bernard, N. Destefano, B. N. V. Edwards, M. Gai, S. A. Hertel, M. Horn, N. A. Larsen, B. P. Tennyson, C. Wahl, D. N. McKinsey

    Abstract: We calibrate a two-phase xenon detector at 0.27 keV in the charge channel and at 2.8 keV in both the light and charge channels using a $^{37}$Ar source that is directly released into the detector. We map the light and charge yields as a function of electric drift field. For the 2.8 keV peak, we calculate the Thomas-Imel box parameter for recombination and determine its dependence on drift field. F… ▽ More

    Submitted 26 June, 2017; v1 submitted 24 May, 2017; originally announced May 2017.

    Comments: 12 pages, 7 figures