Skip to main content

Showing 1–25 of 25 results for author: Edwards, B N

.
  1. arXiv:2104.04824  [pdf

    astro-ph.IM astro-ph.EP

    Ariel: Enabling planetary science across light-years

    Authors: Giovanna Tinetti, Paul Eccleston, Carole Haswell, Pierre-Olivier Lagage, Jérémy Leconte, Theresa Lüftinger, Giusi Micela, Michel Min, Göran Pilbratt, Ludovic Puig, Mark Swain, Leonardo Testi, Diego Turrini, Bart Vandenbussche, Maria Rosa Zapatero Osorio, Anna Aret, Jean-Philippe Beaulieu, Lars Buchhave, Martin Ferus, Matt Griffin, Manuel Guedel, Paul Hartogh, Pedro Machado, Giuseppe Malaguti, Enric Pallé , et al. (293 additional authors not shown)

    Abstract: Ariel, the Atmospheric Remote-sensing Infrared Exoplanet Large-survey, was adopted as the fourth medium-class mission in ESA's Cosmic Vision programme to be launched in 2029. During its 4-year mission, Ariel will study what exoplanets are made of, how they formed and how they evolve, by surveying a diverse sample of about 1000 extrasolar planets, simultaneously in visible and infrared wavelengths.… ▽ More

    Submitted 10 April, 2021; originally announced April 2021.

    Comments: Ariel Definition Study Report, 147 pages. Reviewed by ESA Science Advisory Structure in November 2020. Original document available at: https://www.cosmos.esa.int/documents/1783156/3267291/Ariel_RedBook_Nov2020.pdf/

    Report number: ESA/SCI(2020)1

  2. arXiv:2101.03686  [pdf, other

    physics.ins-det hep-ex physics.app-ph

    The Electric Field Dependence of Single Electron Emission in the PIXeY Two-Phase Xenon Detector

    Authors: E. Bodnia, E. P. Bernard, A. Biekert, E. M. Boulton, S. B. Cahn, N. Destefano, B. N. V. Edwards, M. Gai, M. Horn, N. A. Larsen, Q. Riffard, B. Tennyson, V. Velan, C. Wahl, D. N. McKinsey

    Abstract: Dual phase xenon detectors are widely used in experimental searches for galactic darkmatter particles. The origin of single electron backgrounds following prompt scintillation and proportional scintillation signals in these detectors is not fully understood, although there has been progress in recent years. In this paper, we describe single electron backgrounds in ${}^{83m}Kr$ calibration events a… ▽ More

    Submitted 16 December, 2021; v1 submitted 10 January, 2021; originally announced January 2021.

    Comments: accepted for publication in JINST

    Journal ref: 2021 JINST 16 P12015

  3. arXiv:2006.02506  [pdf, other

    physics.ins-det hep-ex

    The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

    Authors: D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, A. Alquahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, A. Arbuckle, J. E. Armstrong, M. Arthurs, H. Auyeung, S. Aviles, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, J. Bang, M. J. Barry, D. Bauer, P. Bauer, A. Baxter, J. Belle, P. Beltrame, J. Bensinger , et al. (365 additional authors not shown)

    Abstract: LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent… ▽ More

    Submitted 28 February, 2022; v1 submitted 3 June, 2020; originally announced June 2020.

    Comments: 45 pages (79 inc. tables), 7 figures, 9 tables

    Journal ref: The European Physical Journal C, Volume 80, Article number: 1044 (2020)

  4. Analysis of $^{83m}$Kr Prompt Scintillation Signals in the PIXeY Detector

    Authors: A. G. Singh, A. Biekert, E. Bernard, E. M. Boulton, S. B. Cahn, N. Destefano, B. N. V. Edwards, M. Gai, M. Horn, N. Larsen, B. Tennyson, Q. Riffard, V. Velan, C. Wahl, D. N. McKinsey

    Abstract: Prompt scintillation signals from $^{83m}$Kr calibration sources are a useful metric to calibrate the spatial variation of light collection efficiency and electric field magnitude of a two phase liquid-gas xenon time projection chamber. Because $^{83m}$Kr decays in two steps, there are two prompt scintillation pulses for each calibration event, denoted S1a and S1b. We study the ratio of S1b to S1a… ▽ More

    Submitted 9 December, 2019; v1 submitted 10 November, 2019; originally announced November 2019.

    Comments: Version edits: corrected typos and references, revised values presented in section 5.1, analysis conclusion is unchanged

  5. arXiv:1910.09124  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    The LUX-ZEPLIN (LZ) Experiment

    Authors: The LZ Collaboration, D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, A. Alquahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, A. Arbuckle, J. E. Armstrong, M. Arthurs, H. Auyeung, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, J. Bang, M. J. Barry, J. Barthel, D. Bauer, P. Bauer, A. Baxter, J. Belle, P. Beltrame , et al. (357 additional authors not shown)

    Abstract: We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n… ▽ More

    Submitted 3 November, 2019; v1 submitted 20 October, 2019; originally announced October 2019.

  6. arXiv:1907.06272  [pdf, ps, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    Extending light WIMP searches to single scintillation photons in LUX

    Authors: D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, A. Baxter, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, B. Boxer, P. Brás, S. Burdin, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. A. Chiller, C. Chiller, A. Currie, J. E. Cutter, L. de Viveiros, A. Dobi , et al. (100 additional authors not shown)

    Abstract: We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its… ▽ More

    Submitted 27 December, 2019; v1 submitted 14 July, 2019; originally announced July 2019.

    Journal ref: Phys. Rev. D 101, 042001 (2020)

  7. Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector

    Authors: The LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, P. Brás, D. Byram, M. C. Carmona-Benitez, C. Chan, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, E. Druszkiewicz, B. N. Edwards, S. R. Fallon, A. Fan, S. Fiorucci , et al. (68 additional authors not shown)

    Abstract: Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection chambers. We present a measurement of the scintillation timing characteristics of liquid xenon in the LUX dark matter detector and develop a pulse shape discriminant to be used for particle identification. To accurately meas… ▽ More

    Submitted 10 May, 2018; v1 submitted 16 February, 2018; originally announced February 2018.

    Comments: 16 pages, 11 figures

    Journal ref: Phys. Rev. D 97, 112002 (2018)

  8. Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment

    Authors: D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, P. Brás, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, J. E. Y. Dobson, E. Druszkiewicz, B. N. Edwards, C. H. Faham, S. R. Fallon , et al. (73 additional authors not shown)

    Abstract: The LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sections for dark matter. Here, for results derived from ${1.4}\times 10^{4}\;\mathrm{kg\,days}$ of target exposure in 2013, details of the calibration, event-reconstruction, modeling, and statistical tests that underlie the r… ▽ More

    Submitted 15 December, 2017; originally announced December 2017.

    Journal ref: Phys. Rev. D 97, 102008 (2018)

  9. arXiv:1710.11032  [pdf, other

    physics.ins-det hep-ex

    Extraction efficiency of drifting electrons in a two-phase xenon time projection chamber

    Authors: B. N. V. Edwards, E. Bernard, E. M. Boulton, N. Destefano, M. Gai, M. Horn, N. Larsen, B. Tennyson, L. Tvrznikova, C. Wahl, D. N. McKinsey

    Abstract: We present a measurement of the extraction efficiency of quasi-free electrons from the liquid into the gas phase in a two-phase xenon time-projection chamber. The measurements span a range of electric fields from 2.4 to 7.1 kV/cm in the liquid xenon, corresponding to 4.5 to 13.1 kV/cm in the gaseous xenon. Extraction efficiency continues to increase at the highest extraction fields, implying that… ▽ More

    Submitted 7 January, 2018; v1 submitted 30 October, 2017; originally announced October 2017.

  10. arXiv:1710.02752  [pdf, other

    physics.ins-det hep-ex physics.comp-ph

    Position Reconstruction in LUX

    Authors: LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, P. Brás, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, E. Druszkiewicz, B. N. Edwards, S. R. Fallon, A. Fan , et al. (69 additional authors not shown)

    Abstract: The $(x, y)$ position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional fo… ▽ More

    Submitted 12 March, 2018; v1 submitted 7 October, 2017; originally announced October 2017.

    Comments: 30 pages, 17 figures

    Journal ref: Journal of Instrumentation, Volume 13, February 2018, P02001

  11. arXiv:1709.00800  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Ultra-Low Energy Calibration of LUX Detector using $^{127}$Xe Electron Capture

    Authors: LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, P. Brás, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, E. Druszkiewicz, B. N. Edwards, S. R. Fallon, A. Fan , et al. (69 additional authors not shown)

    Abstract: We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in sea… ▽ More

    Submitted 3 September, 2017; originally announced September 2017.

    Comments: 10 pages, 10 figures, 2 tables

    Journal ref: Phys. Rev. D 96, 112011 (2017)

  12. arXiv:1709.00095  [pdf, other

    physics.ins-det hep-ex physics.comp-ph

    3D Modeling of Electric Fields in the LUX Detector

    Authors: LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, P. Brás, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, E. Druszkiewicz, B. N. Edwards, S. R. Fallon, A. Fan , et al. (69 additional authors not shown)

    Abstract: This work details the development of a three-dimensional (3D) electric field model for the LUX detector. The detector took data during two periods of searching for weakly interacting massive particle (WIMP) searches. After the first period completed, a time-varying non-uniform negative charge developed in the polytetrafluoroethylene (PTFE) panels that define the radial boundary of the detector's a… ▽ More

    Submitted 27 November, 2017; v1 submitted 31 August, 2017; originally announced September 2017.

    Journal ref: JINST 12, no. 11, P11022 (2017)

  13. $^{83\textrm{m}}$Kr calibration of the 2013 LUX dark matter search

    Authors: LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, P. Brás, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, E. Druszkiewicz, B. N. Edwards, S. R. Fallon, A. Fan , et al. (69 additional authors not shown)

    Abstract: LUX was the first dark matter experiment to use a $^{83\textrm{m}}$Kr calibration source. In this paper we describe the source preparation and injection. We also present several $^{83\textrm{m}}$Kr calibration applications in the context of the 2013 LUX exposure, including the measurement of temporal and spatial variation in scintillation and charge signal amplitudes, and several methods to unders… ▽ More

    Submitted 8 August, 2017; originally announced August 2017.

    Journal ref: Phys. Rev. D 96, 112009 (2017)

  14. Calibration of a two-phase xenon time projection chamber with a $^{37}$Ar source

    Authors: E. M. Boulton, E. Bernard, N. Destefano, B. N. V. Edwards, M. Gai, S. A. Hertel, M. Horn, N. A. Larsen, B. P. Tennyson, C. Wahl, D. N. McKinsey

    Abstract: We calibrate a two-phase xenon detector at 0.27 keV in the charge channel and at 2.8 keV in both the light and charge channels using a $^{37}$Ar source that is directly released into the detector. We map the light and charge yields as a function of electric drift field. For the 2.8 keV peak, we calculate the Thomas-Imel box parameter for recombination and determine its dependence on drift field. F… ▽ More

    Submitted 26 June, 2017; v1 submitted 24 May, 2017; originally announced May 2017.

    Comments: 12 pages, 7 figures

  15. Limits on spin-dependent WIMP-nucleon cross section obtained from the complete LUX exposure

    Authors: LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, P. Brás, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. A. Chiller, C. Chiller, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, J. E. Y. Dobson, E. Druszkiewicz , et al. (75 additional authors not shown)

    Abstract: We present experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from the total 129.5 kg-year exposure acquired by the Large Underground Xenon experiment (LUX), operating at the Sanford Underground Research Facility in Lead, South Dakota (USA). A profile likelihood ratio analysis allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of… ▽ More

    Submitted 23 June, 2017; v1 submitted 9 May, 2017; originally announced May 2017.

    Comments: 7 pages, 3 figures, version accepted by PRL

    Journal ref: Phys. Rev. Lett. 118, 251302 (2017)

  16. First Searches for Axions and Axion-Like Particles with the LUX Experiment

    Authors: D. S. Akerib, S. Alsum, C. Aquino, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, P. Brás, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. A. Chiller, C. Chiller, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, J. E. Y. Dobson, E. Druszkiewicz , et al. (76 additional authors not shown)

    Abstract: The first searches for axions and axion-like particles with the Large Underground Xenon (LUX) experiment are presented. Under the assumption of an axio-electric interaction in xenon, the coupling constant between axions and electrons, gAe is tested, using data collected in 2013 with an exposure totalling 95 live-days $\times$ 118 kg. A double-sided, profile likelihood ratio statistic test excludes… ▽ More

    Submitted 30 June, 2017; v1 submitted 7 April, 2017; originally announced April 2017.

    Journal ref: Phys. Rev. Lett. 118, 261301 (2017)

  17. arXiv:1610.02076  [pdf, other

    physics.ins-det hep-ex

    Signal yields, energy resolution, and recombination fluctuations in liquid xenon

    Authors: D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, R. Bramante, P. Brás, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. A. Chiller, C. Chiller, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, J. E. Y. Dobson, E. Druszkiewicz , et al. (76 additional authors not shown)

    Abstract: This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and light yields for electronic recoil energies between 5.2 and 661.7 keV are measured, as well as the energy resolution for the LUX detector at those same energies. Additiona… ▽ More

    Submitted 6 October, 2016; originally announced October 2016.

    Comments: 11 pages, 12 figures, 3 tables

    Journal ref: Phys. Rev. D 95, 012008 (2017)

  18. arXiv:1608.07648  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    Results from a search for dark matter in the complete LUX exposure

    Authors: D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, R. Bramante, P. Brás, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. A. Chiller, C. Chiller, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, J. E. Y. Dobson, E. Druszkiewicz , et al. (76 additional authors not shown)

    Abstract: We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high… ▽ More

    Submitted 13 January, 2017; v1 submitted 26 August, 2016; originally announced August 2016.

    Comments: This version includes a combined analysis with previously published LUX results, and matches the version published in PRL

    Journal ref: Phys. Rev. Lett. 118, 021303 (2017)

  19. arXiv:1608.05381  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics

    Authors: LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, A. Bradley, R. Bramante, P. Brás, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, J. J. Chapman, A. A. Chiller, C. Chiller, A. Currie, J. E. Cutter, T. J. R. Davison , et al. (82 additional authors not shown)

    Abstract: The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. T… ▽ More

    Submitted 26 October, 2016; v1 submitted 18 August, 2016; originally announced August 2016.

    Comments: 24 pages, 15 figures, 6 tables

  20. Chromatographic separation of radioactive noble gases from xenon

    Authors: LUX Collaboration, D. S. Akerib, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, R. Bramante, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, A. A. Chiller, C. Chiller, T. Coffey, A. Currie, J. E. Cutter, T. J. R. Davison, A. Dobi, J. E. Y. Dobson, E. Druszkiewicz, B. N. Edwards , et al. (74 additional authors not shown)

    Abstract: The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid xenon typically contains trace amounts of the noble radioactive isotopes $^{85}$Kr and $^{39}$Ar that are not removed by the in situ gas purification system. The decays of the… ▽ More

    Submitted 26 October, 2017; v1 submitted 12 May, 2016; originally announced May 2016.

    Comments: Accepted in Astropart. Phys

  21. Results on the Spin-Dependent Scattering of Weakly Interacting Massive Particles on Nucleons from the Run 3 Data of the LUX Experiment

    Authors: LUX Collaboration, D. S. Akerib, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, A. Bradley, R. Bramante, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, J. J. Chapman, A. A. Chiller, C. Chiller, A. Currie, J. E. Cutter, T. J. R. Davison, L. de Viveiros, A. Dobi, J. E. Y. Dobson , et al. (77 additional authors not shown)

    Abstract: We present the first experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), which is designed to observe the recoil signature of galactic WIMPs scattering from xenon nuclei. A profile likelihood ratio analysis of… ▽ More

    Submitted 16 May, 2016; v1 submitted 10 February, 2016; originally announced February 2016.

    Comments: 6 pages, 2 figures

    Journal ref: Phys. Rev. Lett. 116, 161302 (2016)

  22. arXiv:1512.03506  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data

    Authors: LUX Collaboration, D. S. Akerib, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, A. Bradley, R. Bramante, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, J. J. Chapman, A. A. Chiller, C. Chiller, A. Currie, J. E. Cutter, T. J. R. Davison, L. de Viveiros, A. Dobi, J. E. Y. Dobson , et al. (77 additional authors not shown)

    Abstract: We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background… ▽ More

    Submitted 16 May, 2016; v1 submitted 10 December, 2015; originally announced December 2015.

    Comments: Accepted by Phys. Rev. Lett

    Journal ref: Phys. Rev. Lett. 116, 161301 (2016)

  23. arXiv:1512.03133  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Tritium calibration of the LUX dark matter experiment

    Authors: LUX Collaboration, D. S. Akerib, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, A. Bradley, R. Bramante, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, J. J. Chapman, A. A. Chiller, C. Chiller, A. Currie, J. E. Cutter, T. J. R. Davison, L. de Viveiros, A. Dobi, J. E. Y. Dobson , et al. (76 additional authors not shown)

    Abstract: We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and compare the resu… ▽ More

    Submitted 5 May, 2016; v1 submitted 9 December, 2015; originally announced December 2015.

    Journal ref: Phys. Rev. D 93, 072009 (2016)

  24. FPGA-based Trigger System for the LUX Dark Matter Experiment

    Authors: D. S. Akerib, H. M. Araujo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, A. Bradley, R. Bramante, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, J. J. Chapman, A. A. Chiller, C. Chiller, A. Currie, J. E. Cutter, T. J. R. Davison, L. de Viveiros, A. Dobi, J. E. Y. Dobson, E. Druszkiewicz , et al. (78 additional authors not shown)

    Abstract: LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils resulting from interactions with dark matter particles. Signals from the detector are processed with an FPGA-based digital trigger system that analyzes the incoming data in real-time, with just a few microsecond latency. The system enables first pass selection of events of interest based on their pulse… ▽ More

    Submitted 8 February, 2016; v1 submitted 11 November, 2015; originally announced November 2015.

    Comments: 11 pages, 26 figures, added some key points to the abstract, and conclusions, no change in results, accepted for publication in Nuclear Instruments and Methods in Physics Research Section A

  25. arXiv:1509.02910  [pdf

    physics.ins-det astro-ph.IM hep-ex

    LUX-ZEPLIN (LZ) Conceptual Design Report

    Authors: The LZ Collaboration, D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, S. K. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, M. J. Barry, P. Bauer, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, K. E. Boast, A. I. Bolozdynya, E. M. Boulton, R. Bramante, J. H. Buckley, V. V. Bugaev, R. Bunker, S. Burdin, J. K. Busenitz , et al. (170 additional authors not shown)

    Abstract: The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp… ▽ More

    Submitted 23 September, 2015; v1 submitted 9 September, 2015; originally announced September 2015.

    Comments: 278 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Number One (CD-1) management process. Report also available by chapter at http://hep.ucsb.edu/LZ/CDR. This version includes corrections of minor typographic errors

    Report number: LBNL-190005