-
Variational Autoencoders for Noise Reduction in Industrial LLRF Systems
Authors:
J. P. Edelen,
M. J. Henderson,
J. Einstein-Curtis,
C. C. Hall,
J. A. Diaz Cruz,
A. L. Edelen
Abstract:
Industrial particle accelerators inherently operate in much dirtier environments than typical research accelerators. This leads to an increase in noise both in the RF system and in other electronic systems. Combined with the fact that industrial accelerators are mass produced, there is less attention given to optimizing the performance of an individual system. As a result, industrial systems tend…
▽ More
Industrial particle accelerators inherently operate in much dirtier environments than typical research accelerators. This leads to an increase in noise both in the RF system and in other electronic systems. Combined with the fact that industrial accelerators are mass produced, there is less attention given to optimizing the performance of an individual system. As a result, industrial systems tend to under perform considering their hardware hardware capabilities. With the growing demand for accelerators for medical sterilization, food irradiation, cancer treatment, and imaging, improving the signal processing of these machines will increase the margin for the deployment of these systems. Our work is focusing on using machine learning techniques to reduce the noise of RF signals used for pulse-to-pulse feedback in industrial accelerators. We will review our algorithms, simulation results, and results working with measured data. We will then discuss next steps for deployment and testing on an industrial system.
△ Less
Submitted 7 November, 2023; v1 submitted 29 October, 2023;
originally announced November 2023.
-
LLRF System Considerations for a Compact, Commercial C-band Accelerator using the AMD Xilinx RF-SoC
Authors:
J. Einstein-Curtis,
J. Edelen,
B. Gur,
M. Henderson,
G. Khalsa,
M. Kilpatrick,
R. O'Rourke,
R. Augustsson,
A. Diego,
A. Smirnov,
S. Thielk,
B. Hong,
Z. Li,
C. Liu,
J. Merrick,
E. Nanni,
L. Ruckman,
S. Tantawi,
F. Zuo
Abstract:
This work describes the LLRF and control system in use for a novel accelerator structure developed for a compact design operating in C-band developed by SLAC, with collaboration from RadiaBeam and RadiaSoft. This design is a pulsed RF/pulsed beam system that only provides minimal monitoring for control of each two-cavity pair. Available signals include only a forward and reflected signal for each…
▽ More
This work describes the LLRF and control system in use for a novel accelerator structure developed for a compact design operating in C-band developed by SLAC, with collaboration from RadiaBeam and RadiaSoft. This design is a pulsed RF/pulsed beam system that only provides minimal monitoring for control of each two-cavity pair. Available signals include only a forward and reflected signal for each pair; such a design requires careful consideration of calibration and power-on routines, as well an understanding of how to correct for disturbances caused by the entire RF signal chain, including a new SSA, klystron, and distribution system. An AMD ** for larger-volume manufacturing.
This material is based upon work supported by the Defense Advanced Research Projects Agency under Contract Numbers 140D0423C0006 and 140D0423C0007. The views, opinions, and/or findings expressed are those of the author(s) and should not be interpreted as representing the official views or policies of the Department of Defense or the U.S. Government.
△ Less
Submitted 9 October, 2023; v1 submitted 6 October, 2023;
originally announced October 2023.
-
Impact of Electron Transport Models on Capillary Discharge Plasmas
Authors:
A. Diaw,
S. J. Coleman,
N. M. Cook,
J. Edelen,
E. C. Hansen,
P. Tzeferacos
Abstract:
Magnetohydrodynamics (MHD) can be used to model capillary discharge waveguides in laser-wakefield accelerators. However, the predictive capability of MHD can suffer due to poor microscopic closure models. Here, we study the impact of electron heating and thermal conduction on capillary waveguide performance as part of an effort to understand and quantify uncertainties in modeling and designing nex…
▽ More
Magnetohydrodynamics (MHD) can be used to model capillary discharge waveguides in laser-wakefield accelerators. However, the predictive capability of MHD can suffer due to poor microscopic closure models. Here, we study the impact of electron heating and thermal conduction on capillary waveguide performance as part of an effort to understand and quantify uncertainties in modeling and designing next-generation plasma accelerators. To do so, we perform two-dimensional high-resolution MHD simulations using an argon-filled capillary discharge waveguide with three different electron transport coefficients models. The models tested include (i) Davies et al. (ii) Spitzer, and (iii) Epperlein-Haines (EH). We found that the EH model overestimates the electron temperature inside the channel by over $20\%$ while predicting a lower azimuthal magnetic field. Moreover, the Spitzer model, often used in MHD simulations for plasma-based accelerators, predicts a significantly higher electron temperature than the other models suggest.
△ Less
Submitted 17 March, 2022;
originally announced March 2022.
-
Anomaly Detection in Particle Accelerators using Autoencoders
Authors:
Jonathan P. Edelen,
Nathan M. Cook
Abstract:
The application of machine learning techniques for anomaly detection in particle accelerators has gained popularity in recent years. These efforts have ranged from the analysis of quenches in radio frequency cavities and superconducting magnets to anomalous beam position monitors, and even losses in rings. Using machine learning for anomaly detection can be challenging owing to the inherent imbala…
▽ More
The application of machine learning techniques for anomaly detection in particle accelerators has gained popularity in recent years. These efforts have ranged from the analysis of quenches in radio frequency cavities and superconducting magnets to anomalous beam position monitors, and even losses in rings. Using machine learning for anomaly detection can be challenging owing to the inherent imbalance in the amount of data collected during normal operations as compared to during faults. Additionally, the data are not always labeled and therefore supervised learning is not possible. Autoencoders, neural networks that form a compressed representation and reconstruction of the input data, are a useful tool for such situations. Here we explore the use of autoencoder reconstruction analysis for the prediction of magnet faults in the Advanced Photon Source (APS) storage ring at Argonne National Laboratory.
△ Less
Submitted 14 December, 2021;
originally announced December 2021.
-
Propagation of partially coherent radiation using Wigner functions
Authors:
Boaz Nash,
Nicholas Goldring,
Jonathan Edelen,
Stephen Webb,
Rafael Celestre
Abstract:
Undulator radiation from synchrotron light sources must be transported down a beamline from the source to the sample. A partially coherent photon beam may be represented in phase space using a Wigner function, and its transport may use some similar techniques as is familiar in particle beam transport. We describe this process in the case that the beamline is composed of linear focusing and defocus…
▽ More
Undulator radiation from synchrotron light sources must be transported down a beamline from the source to the sample. A partially coherent photon beam may be represented in phase space using a Wigner function, and its transport may use some similar techniques as is familiar in particle beam transport. We describe this process in the case that the beamline is composed of linear focusing and defocusing sections as well as apertures. We present a compact representation of the beamline map involving linear transformations and convolutions. We create a 1:1 imaging system (4f system) with a single slit on the image plane and observe the radiation downstream to it. We propagate a Gaussian beam and undulator radiation down this sample beamline, drawing parameters from current and future ultra low emittance light sources. We derive an analytic expression for the partially coherent Gaussian case including passage through a single slit aperture. We benchmark the Wigner function calculation against the analytical expression and a partially coherent calculation in the Synchrotron Radiation Workshop (SRW) code.
△ Less
Submitted 16 September, 2020; v1 submitted 15 September, 2020;
originally announced September 2020.
-
A Vlasov Algorithm Derived from Phase Space Conservation
Authors:
Jonathan P. Edelen,
Stephen D. Webb
Abstract:
Existing approaches to solving the Vlasov equation treat the system as a partial differential equation on a phase space grid, and track in either an Eulerian, Lagrangian, or semi-Lagrangian picture. We present an alternative approach, which treats the Vlasov equation as a conservative flow on phase space, and derives its equations of motion using particle-pushing algorithms akin to particle-in-cel…
▽ More
Existing approaches to solving the Vlasov equation treat the system as a partial differential equation on a phase space grid, and track in either an Eulerian, Lagrangian, or semi-Lagrangian picture. We present an alternative approach, which treats the Vlasov equation as a conservative flow on phase space, and derives its equations of motion using particle-pushing algorithms akin to particle-in-cell methods. Deposition to the grid is determined from the convolution of local basis functions. This approach has the benefit of allowing flexible definitions in the grid, which are decoupled from how the phase space flow evolves. We present numerical examples and comment on the various properties of the algorithm.
△ Less
Submitted 23 July, 2020;
originally announced July 2020.
-
Opportunities in Machine Learning for Particle Accelerators
Authors:
Auralee Edelen,
Christopher Mayes,
Daniel Bowring,
Daniel Ratner,
Andreas Adelmann,
Rasmus Ischebeck,
Jochem Snuverink,
Ilya Agapov,
Raimund Kammering,
Jonathan Edelen,
Ivan Bazarov,
Gianluca Valentino,
Jorg Wenninger
Abstract:
Machine learning (ML) is a subfield of artificial intelligence. The term applies broadly to a collection of computational algorithms and techniques that train systems from raw data rather than a priori models. ML techniques are now technologically mature enough to be applied to particle accelerators, and we expect that ML will become an increasingly valuable tool to meet new demands for beam energ…
▽ More
Machine learning (ML) is a subfield of artificial intelligence. The term applies broadly to a collection of computational algorithms and techniques that train systems from raw data rather than a priori models. ML techniques are now technologically mature enough to be applied to particle accelerators, and we expect that ML will become an increasingly valuable tool to meet new demands for beam energy, brightness, and stability. The intent of this white paper is to provide a high-level introduction to problems in accelerator science and operation where incorporating ML-based approaches may provide significant benefit. We review ML techniques currently being investigated at particle accelerator facilities, and we place specific emphasis on active research efforts and promising exploratory results. We also identify new applications and discuss their feasibility, along with the required data and infrastructure strategies. We conclude with a set of guidelines and recommendations for laboratory managers and administrators, emphasizing the logistical and technological requirements for successfully adopting this technology. This white paper also serves as a summary of the discussion from a recent workshop held at SLAC on ML for particle accelerators.
△ Less
Submitted 7 November, 2018;
originally announced November 2018.
-
PIP-II Injector Test Warm Front End: Commissioning Update
Authors:
L. Prost,
R. Andrews,
C. Baffes,
J. -P. Carneiro,
B. Chase,
A. Chen,
E. Cullerton,
P. F. Derwent,
J. P. Edelen,
J. Einstein-Curtis,
D. Frolov,
B. Hanna,
D. Peterson,
G. Saewert,
A. Saini,
V. Scarpine,
A. Shemyakin,
J. Steimel,
D. Sun,
A. Warner,
C. Richard,
V. L. S. Sista
Abstract:
The Warm Front End (WFE) of the Proton Improvement Plan II Injector Test at Fermilab has been constructed to its full length. It includes a 15-mA DC, 30-keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT) with a switching dipole magnet, a 2.1 MeV CW RFQ, followed by a Medium Energy Beam Transport (MEBT) with various diagnostics and a dump. This report presents the commissioning status,…
▽ More
The Warm Front End (WFE) of the Proton Improvement Plan II Injector Test at Fermilab has been constructed to its full length. It includes a 15-mA DC, 30-keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT) with a switching dipole magnet, a 2.1 MeV CW RFQ, followed by a Medium Energy Beam Transport (MEBT) with various diagnostics and a dump. This report presents the commissioning status, focusing on beam measurements in the MEBT. In particular, a beam with the parameters required for injection into the Booster (5 mA, 0.55 ms macro-pulse at 20 Hz) was transported through the WFE.
△ Less
Submitted 14 June, 2018;
originally announced June 2018.
-
Commissioning And First Results From The Fermilab Cryomodule Test Stand
Authors:
E. R. Harms,
M. Awida,
C. Baffes,
K. Carlson,
S. Chandrasekaran,
B. Chase,
E. Cullerton,
J. Edelen,
J. Einstein-Curtis,
C. Ginsburg,
A. Grassellino,
B. Hansen,
J. Holzbauer,
S. Kazakov,
T. Khabiboulline,
M. Kucera,
J. Leibfritz,
A. Lunin,
D. McDowell,
M. McGee,
D. Nicklaus,
D. Orris,
J. Ozelis,
J. Patrick,
T. Petersen
, et al. (12 additional authors not shown)
Abstract:
A new test stand dedicated to Superconducting Radiofrequency (SRF) cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3 GHz cryomodule assembled at Fermilab for LCLS-II. We describe the demonstrated capabilities of CMTS1, report on steps taken during commissioning, provide an overv…
▽ More
A new test stand dedicated to Superconducting Radiofrequency (SRF) cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3 GHz cryomodule assembled at Fermilab for LCLS-II. We describe the demonstrated capabilities of CMTS1, report on steps taken during commissioning, provide an overview of first test results, and survey future plans.
△ Less
Submitted 7 May, 2018;
originally announced May 2018.
-
Adaptive beam loading compensation in room temperature bunching cavities
Authors:
J. P. Edelen,
B. E. Chase,
E. Cullerton,
P. Varghese
Abstract:
In this paper we present the design, simulation, and proof of principle results of an optimization based adaptive feed-forward algorithm for beam-loading compensation in a high impedance room temperature cavity. We begin with an overview of prior developments in beam loading compensation. Then we discuss different techniques for adaptive beam loading compensation and why the use of Newton's Method…
▽ More
In this paper we present the design, simulation, and proof of principle results of an optimization based adaptive feed-forward algorithm for beam-loading compensation in a high impedance room temperature cavity. We begin with an overview of prior developments in beam loading compensation. Then we discuss different techniques for adaptive beam loading compensation and why the use of Newton's Method is of interest for this application. This is followed by simulation and initial experimental results of this method.
△ Less
Submitted 23 March, 2018;
originally announced March 2018.
-
Automatic phase calibration for RF cavities using beam-loading signals
Authors:
J. P. Edelen,
B. E. Chase
Abstract:
Precise calibration of the cavity phase signals is necessary for the operation of any particle accelerator. For many systems this requires human in the loop adjustments based on measurements of the beam parameters downstream. Some recent work has developed a scheme for the calibration of the cavity phase using beam measurements and beam-loading however this scheme is still a multi-step process tha…
▽ More
Precise calibration of the cavity phase signals is necessary for the operation of any particle accelerator. For many systems this requires human in the loop adjustments based on measurements of the beam parameters downstream. Some recent work has developed a scheme for the calibration of the cavity phase using beam measurements and beam-loading however this scheme is still a multi-step process that requires heavy automation or human in the loop. In this paper we analyze a new scheme that uses only RF signals reacting to beam-loading to calculate the phase of the beam relative to the cavity. This technique could be used in slow control loops to provide real-time adjustment of the cavity phase calibration without human intervention thereby increasing the stability and reliability of the accelerator.
△ Less
Submitted 23 March, 2018;
originally announced March 2018.
-
Status of the warm front end of PIP-II injector test
Authors:
A. Shemyakin,
M. Alvarez,
R. Andrews,
C. Baffes,
J. -P. Carneiro,
A. Chen,
P. F. Derwent,
J. P. Edelen,
D. Frolov,
B. Hanna,
L. Prost,
A. Saini,
G. Saewert,
V. Scarpine,
V. L. S. Sista,
J. Steimel,
D. Sun,
A. Warner
Abstract:
The Proton Improvement Plan II (PIP-II) at Fermilab is a program of upgrades to the injection complex. At its core is the design and construction of a CW compatible, pulsed H- SRF linac. To validate the concept of the front-end of such machine, a test accelerator known as PIP-II Injector Test (PIP2IT) is under construction. It includes a 10 mA DC, 30 keV H- ion source, a 2 m-long Low Energy Beam T…
▽ More
The Proton Improvement Plan II (PIP-II) at Fermilab is a program of upgrades to the injection complex. At its core is the design and construction of a CW compatible, pulsed H- SRF linac. To validate the concept of the front-end of such machine, a test accelerator known as PIP-II Injector Test (PIP2IT) is under construction. It includes a 10 mA DC, 30 keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1 MeV CWRFQ, followed by a Medium Energy Beam Transport (MEBT) that feeds the first of 2 cryomodules increasing the beam energy to about 25 MeV, and a High Energy Beam Transport section (HEBT) that takes the beam to a dump. The ion source, LEBT, RFQ, and initial version of the MEBT have been built, installed, and commissioned. This report presents the overall status of the warm front end.
△ Less
Submitted 23 March, 2018;
originally announced March 2018.
-
Low Level RF Control for the PIP-II Accelerator
Authors:
J. P. Edelen,
B. E. Chase,
E. Cullerton,
J. Einstein-Curtis,
J. Holzbauer,
D. Klepec,
Y. Pischalnikov,
W. Schappert,
P. Varghese,
G. Joshi,
S. Khole,
D. Sharma
Abstract:
The PIP-II accelerator is a proposed upgrade to the Fermilab accelerator complex that will replace the existing, 400 MeV room temperature LINAC with an 800 MeV superconducting LINAC. Part of this upgrade includes a new injection scheme into the booster that levies tight requirements on the LLRF control system for the cavities. In this paper we discuss the challenges of the PIP-II accelerator and t…
▽ More
The PIP-II accelerator is a proposed upgrade to the Fermilab accelerator complex that will replace the existing, 400 MeV room temperature LINAC with an 800 MeV superconducting LINAC. Part of this upgrade includes a new injection scheme into the booster that levies tight requirements on the LLRF control system for the cavities. In this paper we discuss the challenges of the PIP-II accelerator and the present status of the LLRF system for this project.
△ Less
Submitted 21 March, 2018;
originally announced March 2018.
-
Current transmission and nonlinear effects in un-gated thermionic cathode RF guns
Authors:
J. P. Edelen,
J. R. Harris
Abstract:
Un-gated thermionic cathode RF guns are well known as a robust source of electrons for many accelerator applications. These sources are in principle scalable to high currents without degradation of the transverse emittance due to control grids but they are also known for being limited by back-bombardment. While back-bombardment presents a significant limitation, there is still a lack of general un…
▽ More
Un-gated thermionic cathode RF guns are well known as a robust source of electrons for many accelerator applications. These sources are in principle scalable to high currents without degradation of the transverse emittance due to control grids but they are also known for being limited by back-bombardment. While back-bombardment presents a significant limitation, there is still a lack of general understanding on how emission over the whole RF period will affect the nature of the beams produced from these guns. In order to improve our understanding of how these guns can be used in general we develop analytical models that predict the transmission efficiency as a function of the design parameters, study how bunch compression and emission enhancement caused by Schottky barrier lowering affect the output current profile in the gun, and study the onset of space-charge limited effects and the resultant virtual cathode formation leading to a modulation in the output current distribution.
△ Less
Submitted 3 May, 2017;
originally announced May 2017.
-
Observation Of Repetition-Rate Dependent Emission From an Un-Gated Thermionic Cathode RF Gun
Authors:
J. P. Edelen,
Y. Sun,
J. R. Harris,
J. W. Lewellen
Abstract:
Recent work at Fermilab in collaboration with the Advanced Photon Source and members of other national labs, designed an experiment to study the relationship between the RF repetition rate and the average current per RF pulse. While existing models anticipate a direct relationship between these two parameters we observed an inverse relationship. We believe this is a result of damage to the barium…
▽ More
Recent work at Fermilab in collaboration with the Advanced Photon Source and members of other national labs, designed an experiment to study the relationship between the RF repetition rate and the average current per RF pulse. While existing models anticipate a direct relationship between these two parameters we observed an inverse relationship. We believe this is a result of damage to the barium coating on the cathode surface caused by a change in back-bombardment power that is unaccounted for in the existing theories. These observations shed new light on the challenges and fundamental limitations associated with scaling an un-gated thermionic cathode RF gun to high average current machines.
△ Less
Submitted 24 February, 2017;
originally announced February 2017.
-
Installation Progress At The PIP-II Injector Test At Fermilab
Authors:
C. Baffes,
M. Alvarez,
R. Andrews,
A. Chen,
J. Czajkowski,
P. Derwent,
J. Edelen,
B. Hanna,
B. Hartsell,
K. Kendziora,
D. Mitchell,
L. Prost,
V. Scarpine,
A. Shemyakin,
J. Steimel,
T. Zuchnik,
A. Edelen
Abstract:
A CW-compatible, pulsed H- superconducting linac "PIP-II" is being planned to upgrade Fermilab's injection complex. To validate the front-end concept, a test accelerator (The PIP-II Injector Test, formerly known as "PXIE") is under construction. The warm part of this accelerator comprises a 10 mA DC, 30 keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1 MeV Radio Frequency Quadr…
▽ More
A CW-compatible, pulsed H- superconducting linac "PIP-II" is being planned to upgrade Fermilab's injection complex. To validate the front-end concept, a test accelerator (The PIP-II Injector Test, formerly known as "PXIE") is under construction. The warm part of this accelerator comprises a 10 mA DC, 30 keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1 MeV Radio Frequency Quadrupole (RFQ) capable of operation in Continuous Wave (CW) mode, and a 10 m-long Medium Energy Beam Transport (MEBT). The paper will report on the installation of the RFQ and the first sections of the MEBT and related mechanical design considerations.
△ Less
Submitted 4 January, 2017;
originally announced January 2017.
-
Neural Network Model Of The PXIE RFQ Cooling System and Resonant Frequency Response
Authors:
A. L. Edelen,
S. G. Biedron,
S. V. Milton,
D. Bowring,
B. E. Chase,
J. P. Edelen,
J. Steimel
Abstract:
As part of the PIP-II Injector Experiment (PXIE) accelerator, a four-vane radio frequency quadrupole (RFQ) accelerates a 30-keV, 1-mA to 10-mA H- ion beam to 2.1 MeV. It is designed to operate at a frequency of 162.5 MHz with arbitrary duty factor, including continuous wave (CW) mode. The resonant frequency is controlled solely by a water-cooling system. We present an initial neural network model…
▽ More
As part of the PIP-II Injector Experiment (PXIE) accelerator, a four-vane radio frequency quadrupole (RFQ) accelerates a 30-keV, 1-mA to 10-mA H- ion beam to 2.1 MeV. It is designed to operate at a frequency of 162.5 MHz with arbitrary duty factor, including continuous wave (CW) mode. The resonant frequency is controlled solely by a water-cooling system. We present an initial neural network model of the RFQ frequency response to changes in the cooling system and RF power conditions during pulsed operation. A neural network model will be used in a model predictive control scheme to regulate the resonant frequency of the RFQ.
△ Less
Submitted 21 December, 2016;
originally announced December 2016.
-
First Steps Toward Incorporating Image Based Diagnostics Into Particle Accelerator Control Systems Using Convolutional Neural Networks
Authors:
A. L. Edelen,
S. G. Biedron,
S. V. Milton,
J. P. Edelen
Abstract:
At present, a variety of image-based diagnostics are used in particle accelerator systems. Often times, these are viewed by a human operator who then makes appropriate adjustments to the machine. Given recent advances in using convolutional neural networks (CNNs) for image processing, it should be possible to use image diagnostics directly in control routines (NN-based or otherwise). This is espec…
▽ More
At present, a variety of image-based diagnostics are used in particle accelerator systems. Often times, these are viewed by a human operator who then makes appropriate adjustments to the machine. Given recent advances in using convolutional neural networks (CNNs) for image processing, it should be possible to use image diagnostics directly in control routines (NN-based or otherwise). This is especially appealing for non-intercepting diagnostics that could run continuously during beam operation. Here, we show results of a first step toward implementing such a controller: our trained CNN can predict multiple simulated downstream beam parameters at the Fermilab Accelerator Science and Technology (FAST) facility's low energy beamline using simulated virtual cathode laser images, gun phases, and solenoid strengths.
△ Less
Submitted 16 December, 2016;
originally announced December 2016.
-
Resonant Frequency Control For the PIP-II Injector Test RFQ: Control Framework and Initial Results
Authors:
A. L. Edelen,
S. G. Biedron,
S. V. Milton,
D. Bowring,
B. E. Chase,
J. P. Edelen,
D. Nicklaus,
J. Steimel
Abstract:
For the PIP-II Injector Test (PI-Test) at Fermilab, a four-vane radio frequency quadrupole (RFQ) is designed to accelerate a 30-keV, 1-mA to 10-mA, H- beam to 2.1 MeV under both pulsed and continuous wave (CW) RF operation. The available headroom of the RF amplifiers limits the maximum allowable detuning to 3 kHz, and the detuning is controlled entirely via thermal regulation. Fine control over th…
▽ More
For the PIP-II Injector Test (PI-Test) at Fermilab, a four-vane radio frequency quadrupole (RFQ) is designed to accelerate a 30-keV, 1-mA to 10-mA, H- beam to 2.1 MeV under both pulsed and continuous wave (CW) RF operation. The available headroom of the RF amplifiers limits the maximum allowable detuning to 3 kHz, and the detuning is controlled entirely via thermal regulation. Fine control over the detuning, minimal manual intervention, and fast trip recovery is desired. In addition, having active control over both the walls and vanes provides a wider tuning range. For this, we intend to use model predictive control (MPC). To facilitate these objectives, we developed a dedicated control framework that handles higher-level system decisions as well as executes control calculations. It is written in Python in a modular fashion for easy adjustments, readability, and portability. Here we describe the framework and present the first control results for the PI-Test RFQ under pulsed and CW operation.
△ Less
Submitted 16 December, 2016;
originally announced December 2016.