-
Direct map** of nuclear shell effects in the heaviest elements
Authors:
E. Minaya Ramirez,
D. Ackermann,
K. Blaum,
M. Block,
C. Droese,
Ch. E. Düllmann,
M. Dworschak,
M. Eibach,
S. Eliseev,
E. Haettner,
F. Herfurth,
F. P. Heßberger,
S. Hofmann,
J. Ketelaer,
G. Marx,
M. Mazzocco,
D. Nesterenko,
Yu. N. Novikov,
W. R. Plaß,
D. Rodríguez,
C. Scheidenberger,
L. Schweikhard,
P. G. Thirolf,
C. Weber
Abstract:
Quantum-mechanical shell effects are expected to strongly enhance nuclear binding on an "island of stability" of superheavy elements. The predicted center at proton number $Z=114,120$, or $126$ and neutron number $N=184$ has been substantiated by the recent synthesis of new elements up to $Z=118$. However the location of the center and the extension of the island of stability remain vague. High-pr…
▽ More
Quantum-mechanical shell effects are expected to strongly enhance nuclear binding on an "island of stability" of superheavy elements. The predicted center at proton number $Z=114,120$, or $126$ and neutron number $N=184$ has been substantiated by the recent synthesis of new elements up to $Z=118$. However the location of the center and the extension of the island of stability remain vague. High-precision mass spectrometry allows the direct measurement of nuclear binding energies and thus the determination of the strength of shell effects. Here, we present such measurements for nobelium and lawrencium isotopes, which also pin down the deformed shell gap at $N=152$.
△ Less
Submitted 25 June, 2014;
originally announced June 2014.
-
Position-sensitive ion detection in precision Penning trap mass spectrometry
Authors:
G. Eitel,
M. Block,
A. Czasch,
M. Dworschak,
S. George,
O. Jagutzki,
J. Ketelaer,
J. Ketter,
Sz. Nagy,
D. Rodriguez,
C. Smorra,
K. Blaum
Abstract:
A commercial, position-sensitive ion detector was used for the first time for the time-of-flight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its implementation in a Penning trap mass spectrometer will be presented. In addition, simulations and experimental studies concerning the observation of ions ejected f…
▽ More
A commercial, position-sensitive ion detector was used for the first time for the time-of-flight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its implementation in a Penning trap mass spectrometer will be presented. In addition, simulations and experimental studies concerning the observation of ions ejected from a Penning trap are described. This will allow for a precise monitoring of the state of ion motion in the trap.
△ Less
Submitted 1 June, 2009;
originally announced June 2009.
-
Mass measurements beyond the major r-process waiting point 80Zn
Authors:
S. Baruah,
G. Audi,
K. Blaum,
M. Dworschak,
S. George,
C. Guenaut,
U. Hager,
F. Herfurth,
A. Herlert,
A. Kellerbauer,
H. -J. Kluge,
D. Lunney,
H. Schatz,
L. Schweikhard,
C. Yazidjian
Abstract:
High-precision mass measurements on neutron-rich zinc isotopes 71m,72-81Zn have been performed with the Penning trap mass spectrometer ISOLTRAP. For the first time the mass of 81Zn has been experimentally determined. This makes 80Zn the first of the few major waiting points along the path of the astrophysical rapid neutron capture process where neutron separation energy and neutron capture Q-val…
▽ More
High-precision mass measurements on neutron-rich zinc isotopes 71m,72-81Zn have been performed with the Penning trap mass spectrometer ISOLTRAP. For the first time the mass of 81Zn has been experimentally determined. This makes 80Zn the first of the few major waiting points along the path of the astrophysical rapid neutron capture process where neutron separation energy and neutron capture Q-value are determined experimentally. As a consequence, the astrophysical conditions required for this waiting point and its associated abundance signatures to occur in r-process models can now be mapped precisely. The measurements also confirm the robustness of the N = 50 shell closure for Z = 30 farther from stability.
△ Less
Submitted 14 November, 2008;
originally announced November 2008.
-
Mass measurements in the vicinity of the rp-process and the nu p-process paths with JYFLTRAP and SHIPTRAP
Authors:
C. Weber,
V. -V. Elomaa,
R. Ferrer,
C. Fröhlich,
D. Ackermann,
J. Äystö,
G. Audi,
L. Batist,
K. Blaum,
M. Block,
A. Chaudhuri,
M. Dworschak,
S. Eliseev,
T. Eronen,
U. Hager,
J. Hakala,
F. Herfurth,
F. P. Heßberger,
S. Hofmann,
A. Jokinen,
A. Kankainen,
H. -J. Kluge,
K. Langanke,
A. Martín,
G. Martínez-Pinedo
, et al. (20 additional authors not shown)
Abstract:
The masses of very neutron-deficient nuclides close to the astrophysical rp- and nu p-process paths have been determined with the Penning trap facilities JYFLTRAP at JYFL/Jyväskylä and SHIPTRAP at GSI/Darmstadt. Isotopes from yttrium (Z = 39) to palladium (Z = 46) have been produced in heavy-ion fusion-evaporation reactions. In total 21 nuclides were studied and almost half of the mass values we…
▽ More
The masses of very neutron-deficient nuclides close to the astrophysical rp- and nu p-process paths have been determined with the Penning trap facilities JYFLTRAP at JYFL/Jyväskylä and SHIPTRAP at GSI/Darmstadt. Isotopes from yttrium (Z = 39) to palladium (Z = 46) have been produced in heavy-ion fusion-evaporation reactions. In total 21 nuclides were studied and almost half of the mass values were experimentally determined for the first time: 88Tc, 90-92Ru, 92-94Rh, and 94,95Pd. For the 95Pdm, (21/2^+) high-spin state, a first direct mass determination was performed. Relative mass uncertainties of typically $δm / m = 5 \times 10^{-8}$ were obtained. The impact of the new mass values has been studied in nu p-process nucleosynthesis calculations. The resulting reaction flow and the final abundances are compared to those obtained with the data of the Atomic Mass Evaluation 2003.
△ Less
Submitted 29 August, 2008;
originally announced August 2008.
-
Magnetic field stabilization for high-accuracy mass measurements on exotic nuclides
Authors:
M. Marie-Jeanne,
J. Alonso,
K. Blaum,
S. Djekic,
M. Dworschak,
U. Hager,
A. Herlert,
Sz. Nagy,
R. Savreux,
L. Schweikhard,
S. Stahl,
C. Yazidjian
Abstract:
The magnetic-field stability of a mass spectrometer plays a crucial role in precision mass measurements. In the case of mass determination of short-lived nuclides with a Penning trap, major causes of instabilities are temperature fluctuations in the vicinity of the trap and pressure fluctuations in the liquid helium cryostat of the superconducting magnet. Thus systems for the temperature and pre…
▽ More
The magnetic-field stability of a mass spectrometer plays a crucial role in precision mass measurements. In the case of mass determination of short-lived nuclides with a Penning trap, major causes of instabilities are temperature fluctuations in the vicinity of the trap and pressure fluctuations in the liquid helium cryostat of the superconducting magnet. Thus systems for the temperature and pressure stabilization of the Penning trap mass spectrometer ISOLTRAP at the ISOLDE facility at CERN have been installed. A reduction of the fluctuations by at least one order of magnitude downto dT=+/-5mK and dp=+/-50mtorr has been achieved, which corresponds to a relative frequency change of 2.7x10^{-9} and 1.5x10^{-10}, respectively. With this stabilization the frequency determination with the Penning trap only shows a linear temporal drift over several hours on the 10 ppb level due to the finite resistance of the superconducting magnet coils.
△ Less
Submitted 19 January, 2007;
originally announced January 2007.