-
Testing Meson Portal Dark Sector Solutions to the MiniBooNE Anomaly at CCM
Authors:
A. A. Aguilar-Arevalo,
S. Biedron,
J. Boissevain,
M. Borrego,
L. Bugel,
M. Chavez-Estrada,
J. M. Conrad,
R. L. Cooper,
A. Diaz,
J. R. Distel,
J. C. D'Olivo,
E. Dunton,
B. Dutta,
D. Fields,
J. R. Gochanour,
M. Gold,
E. Guardincerri,
E. C. Huang,
N. Kamp,
D. Kim,
K. Knickerbocker,
W. C. Louis,
J. T. M. Lyles,
R. Mahapatra,
S. Maludze
, et al. (20 additional authors not shown)
Abstract:
A solution to the MiniBooNE excess invoking rare three-body decays of the charged pions and kaons to new states in the MeV mass scale was recently proposed as a dark-sector explanation. This class of solution illuminates the fact that, while the charged pions were focused in the target-mode run, their decay products were isotropically suppressed in the beam-dump-mode run in which no excess was obs…
▽ More
A solution to the MiniBooNE excess invoking rare three-body decays of the charged pions and kaons to new states in the MeV mass scale was recently proposed as a dark-sector explanation. This class of solution illuminates the fact that, while the charged pions were focused in the target-mode run, their decay products were isotropically suppressed in the beam-dump-mode run in which no excess was observed. This suggests a new physics solution correlated to the mesonic sector. We investigate an extended set of phenomenological models that can explain the MiniBooNE excess as a dark sector solution, utilizing long-lived particles that might be produced in the three-body decays of the charged mesons and the two-body anomalous decays of the neutral mesons. Over a broad set of interactions with the long-lived particles, we show that these scenarios can be compatible with constraints from LSND, KARMEN, and MicroBooNE, and evaluate the sensitivity of the ongoing and future data taken by the Coherent CAPTAIN Mills experiment (CCM) to a potential discovery in this parameter space.
△ Less
Submitted 4 May, 2024; v1 submitted 5 September, 2023;
originally announced September 2023.
-
Prospects for detecting axionlike particles at the Coherent CAPTAIN-Mills experiment
Authors:
A. A. Aguilar-Arevalo,
D. S. M. Alves,
S. Biedron,
J. Boissevain,
M. Borrego,
L. Bugel,
M. Chavez-Estrada,
J. M. Conrad,
R. L. Cooper,
A. Diaz,
J. R. Distel,
J. C. D'Olivo,
E. Dunton,
B. Dutta,
D. Fields,
J. R. Gochanour,
M. Gold,
E. Guardincerri,
E. C. Huang,
N. Kamp,
D. Kim,
K. Knickerbocker,
W. C. Louis,
J. T. M. Lyles,
R. Mahapatra
, et al. (23 additional authors not shown)
Abstract:
We show results from the Coherent CAPTAIN Mills (CCM) 2019 engineering run which begin to constrain regions of parameter space for axion-like particles (ALPs) produced in electromagnetic particle showers in an 800 MeV proton beam dump, and further investigate the sensitivity of ongoing data-taking campaigns for the CCM200 upgraded detector. Based on beam-on background estimates from the engineerin…
▽ More
We show results from the Coherent CAPTAIN Mills (CCM) 2019 engineering run which begin to constrain regions of parameter space for axion-like particles (ALPs) produced in electromagnetic particle showers in an 800 MeV proton beam dump, and further investigate the sensitivity of ongoing data-taking campaigns for the CCM200 upgraded detector. Based on beam-on background estimates from the engineering run, we make realistic extrapolations for background reduction based on expected shielding improvements, reduced beam width, and analysis-based techniques for background rejection. We obtain reach projections for two classes of signatures; ALPs coupled primarily to photons can be produced in the tungsten target via the Primakoff process, and then produce a gamma-ray signal in the Liquid Argon (LAr) CCM detector either via inverse Primakoff scattering or decay to a photon pair. ALPs with significant electron couplings have several additional production mechanisms (Compton scattering, $e^+e^-$ annihilation, ALP-bremsstrahlung) and detection modes (inverse Compton scattering, external $e^+e^-$ pair conversion, and decay to $e^+e^-$). In some regions, the constraint is marginally better than both astrophysical and terrestrial constraints. With the beginning of a three year run, CCM will be more sensitive to this parameter space by up to an order of magnitude for both ALP-photon and ALP-electron couplings. The CCM experiment will also have sensitivity to well-motivated parameter space of QCD axion models. It is only a recent realization that accelerator-based large volume liquid argon detectors designed for low energy coherent neutrino and dark matter scattering searches are also ideal for probing ALPs in the unexplored $\sim$MeV mass scale.
△ Less
Submitted 26 May, 2023; v1 submitted 18 December, 2021;
originally announced December 2021.
-
First Leptophobic Dark Matter Search from Coherent CAPTAIN-Mills
Authors:
A. A. Aguilar-Arevalo,
D. S. M. Alves,
S. Biedron,
J. Boissevain,
M. Borrego,
M. Chavez-Estrada,
A. Chavez,
J. M. Conrad,
R. L. Cooper,
A. Diaz,
J. R. Distel,
J. C. D'Olivo,
E. Dunton,
B. Dutta,
A. Elliott,
D. Evans,
D. Fields,
J. Greenwood,
M. Gold,
J. Gordon,
E. Guarincerri,
E. C. Huang,
N. Kamp,
C. Kelsey,
K. Knickerbocker
, et al. (26 additional authors not shown)
Abstract:
We report the first results of a search for leptophobic dark matter (DM) from the Coherent CAPTAIN-Mills (CCM) liquid argon (LAr) detector. An engineering run with 120 photomultiplier tubes (PMTs) and $17.9 \times 10^{20}$ protons-on-target (POT) was performed in Fall 2019 to study the characteristics of the CCM detector. The operation of this 10-ton detector was strictly light-based with a thresh…
▽ More
We report the first results of a search for leptophobic dark matter (DM) from the Coherent CAPTAIN-Mills (CCM) liquid argon (LAr) detector. An engineering run with 120 photomultiplier tubes (PMTs) and $17.9 \times 10^{20}$ protons-on-target (POT) was performed in Fall 2019 to study the characteristics of the CCM detector. The operation of this 10-ton detector was strictly light-based with a threshold of 50 keV and used coherent elastic scattering off argon nuclei to detect DM. Despite only 1.5 months of accumulated luminosity, contaminated LAr, and non-optimized shielding, CCM's first engineering run already achieved sensitivity to previously unexplored parameter space of light dark matter (LDM) models with a baryonic vector portal. With an expected background of 115,005 events, we observe 115,005+16.5 events which is compatible with background expectations. For a benchmark mediator-to-dark matter mass ratio of $m_{_{V_B}}/m_χ=2.1$, DM masses within the range $9\,\text{MeV} \lesssim m_χ\lesssim 50\,\text{MeV}$ have been excluded at 90% C.L. in the leptophobic model after applying the Feldman-Cousins test statistic. CCM's upgraded run with 200 PMTs, filtered LAr, improved shielding, and ten times more POT will be able to exclude the remaining thermal relic density parameter space of this model, as well as probe new parameter space of other leptophobic DM models.
△ Less
Submitted 19 May, 2022; v1 submitted 28 September, 2021;
originally announced September 2021.
-
First Dark Matter Search Results From Coherent CAPTAIN-Mills
Authors:
A. A. Aguilar-Arevalo,
S. Biedron,
J. Boissevain,
M. Borrego,
M. Chavez-Estrada,
A. Chavez,
J. M. Conrad,
R. L. Cooper,
A. Diaz,
J. R. Distel,
J. D'Olivo,
E. Dunton,
B. Dutta,
A. Elliott,
D. Evans,
D. Fields,
J. Greenwood,
M. Gold,
J. Gordon,
E. D. Guarincerri,
E. C. Huang,
N. Kamp,
C. Kelsey,
K. Knickerbocker,
R. Lake
, et al. (25 additional authors not shown)
Abstract:
This paper describes the operation of the Coherent CAPTAIN-Mills (CCM) detector located at the Lujan Neutron Science Center (LANSCE) at Los Alamos National Laboratory (LANL). CCM is a 10-ton liquid argon (LAr) detector located 20 meters from a high flux neutron/neutrino source and is designed to search for sterile neutrinos ($ν_s$) and light dark matter (LDM). An engineering run was performed in F…
▽ More
This paper describes the operation of the Coherent CAPTAIN-Mills (CCM) detector located at the Lujan Neutron Science Center (LANSCE) at Los Alamos National Laboratory (LANL). CCM is a 10-ton liquid argon (LAr) detector located 20 meters from a high flux neutron/neutrino source and is designed to search for sterile neutrinos ($ν_s$) and light dark matter (LDM). An engineering run was performed in Fall 2019 to study the characteristics of the CCM120 detector by searching for coherent scattering signals consistent with $ν_s$'s and LDM resulting from $π^+$ and $π^0$ decays in the tungsten target. New parameter space in a leptophobic dark matter model was excluded for DM masses between $\sim2.0$ and 30 MeV. The lessons learned from this run have guided the development and construction of the new CCM200 detector that will begin operations in 2021 and significantly improve on these searches.
△ Less
Submitted 19 May, 2022; v1 submitted 28 May, 2021;
originally announced May 2021.
-
Shielding Design for the ISODAR Neutrino Experiment
Authors:
Adriana Bungau,
Jose Alonso,
Larry Bartoszek,
Janet M. Conrad,
Edward Dunton,
Michael H. Shaevitz
Abstract:
The IsoDAR sterile-neutrino search requires a very high intensity neutrino source. For IsoDAR, this high intensity is produced using the high neutron flux from a 60 MeV, 10 mA proton beam striking a beryllium target that floods a sleeve of highly-enriched Li-7. Through neutron capture the Li-7 is transmuted to Li-8, which beta-decays giving the desired high neutrino flux for very-short baseline ne…
▽ More
The IsoDAR sterile-neutrino search requires a very high intensity neutrino source. For IsoDAR, this high intensity is produced using the high neutron flux from a 60 MeV, 10 mA proton beam striking a beryllium target that floods a sleeve of highly-enriched Li-7. Through neutron capture the Li-7 is transmuted to Li-8, which beta-decays giving the desired high neutrino flux for very-short baseline neutrino experiments. The target can be placed very close to can existing large neutrino detector, which is typically located deep underground to reduce backgrounds. With such a setup, it is necessary to design a shielding enclosure for the target to prevent neutrons from causing unacceptable activation of the rock walls close to the target. Various materials have been studied including steel to thermalize the high energy neutrons and two new types of concrete developed by Jefferson Laboratory, one very light with shredded plastic aggregate, and the other one enriched with high quantities of boron. The shielding is asymmetrical, having a larger thickness towards the detector in order to suppress the neutron and gamma background in the neutrino detector. Simulation results for rock activation and for detector backgrounds are presented.
△ Less
Submitted 17 September, 2019;
originally announced September 2019.