-
Instrumentation for correlated prompt $n$-$γ$ emission studies in coincidence with fission fragments
Authors:
S. Marin,
I. Tolstukhin,
M. B. Oberling,
R. A. Knaack,
B. P. Kay,
D. L. Duke,
K. B. Montoya,
D. Connolly,
W. Loveland,
A. Chemey,
S. A. Pozzi,
F. Tovesson
Abstract:
Recent theoretical and experimental results have brought renewed interest and focus on the topic of fission fragment angular momentum. Measurements of neutrons and $γ$ rays in coincidence with fission fragments remain the most valuable tool in the exploration of fission physics. To achieve these scientific goals, we have developed a system that combines a state-of-the-art fission fragment detector…
▽ More
Recent theoretical and experimental results have brought renewed interest and focus on the topic of fission fragment angular momentum. Measurements of neutrons and $γ$ rays in coincidence with fission fragments remain the most valuable tool in the exploration of fission physics. To achieve these scientific goals, we have developed a system that combines a state-of-the-art fission fragment detector and $n$-$γ$ radiation detectors. A new twin Frisch-gridded ionization chamber has been designed and constructed for use with a spontaneous fission source and an array of forty \textit{trans}-stilbene organic scintillators (FS-3) at Argonne National Laboratory. The new ionization chamber design we present in this work aims at minimizing particle attenuation in the chamber walls, and provides a compact apparatus that can be fit inside existing experimental systems. The ionization chamber is capable of measuring fission fragment masses and kinetic energies, whereas the FS-3 provides neutron and gamma-ray multiplicities and spectra. The details of both detector assembly are presented along with the first experimental results of this setup. Planned event-by-event analysis and future experiments are briefly discussed.
△ Less
Submitted 30 October, 2022;
originally announced October 2022.
-
Properties of correlated fission fragments from neutron induced fission of Np-237 at incident neutron energies between 200 keV and 100 MeV
Authors:
D. Connolly,
K. B. Montoya,
D. L. Duke,
U. Greife,
A. E. Lovell,
S. Mosby,
C. Prokop,
E. Rudziensky,
K. Schmitt,
J. Winkelbauer
Abstract:
Neutron-induced fission of $^{237}$Np has been measured over a wide range of incident neutron energies using a twin Frisch-gridded ionization chamber (TFGIC) and a thin-backed $^{237}$Np target. These measurements were performed at the Los Alamos Neutron Science Center - Weapons Neutron Research (LANSCE - WNR) facility, which provides a collimated beam of neutrons with energies ranging from 100s o…
▽ More
Neutron-induced fission of $^{237}$Np has been measured over a wide range of incident neutron energies using a twin Frisch-gridded ionization chamber (TFGIC) and a thin-backed $^{237}$Np target. These measurements were performed at the Los Alamos Neutron Science Center - Weapons Neutron Research (LANSCE - WNR) facility, which provides a collimated beam of neutrons with energies ranging from 100s of keV to 100s of MeV. The data were analyzed using the double-energy ($2E$) method, with mass-dependent corrections for prompt-fission neutrons and pulse height defect. Pre- and post-neutron evaporation average total kinetic energy ($\langle TKE\rangle$) values are reported for 54 incident neutron energies in the energy range $0.20 \le E_n \le 100.0$ MeV and compared to existing data and evaluations. Pre- and post-neutron evaporation mass yields were extracted with a full width at half maximum (FWHM) resolution of 4u and compared to existing data and evaluations. The present $\langle TKE\rangle$ and mass yield data agree with previous results and also with statistical models of $^{237}$Np$(n,f)$ at incident neutron energies between $E_n = 0.2 - 20.0$ MeV. A flattening of the $\langle TKE\rangle$ data is observed (relative to the prediction of the GEF model) above $E_n = 20.0$ MeV. However, the interpretation of this discrepancy is unclear as the analysis method's neglect of incomplete momentum transfer at high energies, as well as pre-equilibrium pre-fission phenomena likely have a significant impact on the measurement at such high incident neutron energies.
△ Less
Submitted 9 January, 2022; v1 submitted 24 November, 2021;
originally announced November 2021.
-
Neutron Induced Fission Fragment Angular Distributions, Anisotropy, and Linear Momentum Transfer Measured with the NIFFTE Fission Time Projection Chamber
Authors:
D. Hensle,
J. T. Barker,
J. S. Barrett,
N. S. Bowden,
K. J. Brewster,
J. Bundgaard,
Z. Q. Case,
R. J. Casperson,
D. A. Cebra,
T. Classen,
D. L. Duke,
N. Fotiadis,
J Gearhart,
V. Geppert-Kleinrath,
U. Greife,
E. Guardincerri,
C. Hagmann,
M. Heffner,
C. R. Hicks,
D. Higgins,
L. D. Isenhower,
K. Kazkaz,
A. Kemnitz,
K. J. Kiesling,
J. King
, et al. (24 additional authors not shown)
Abstract:
The Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) collaboration has performed measurements with a fission time projection chamber (fissionTPC) to study the fission process by reconstructing full three-dimensional tracks of fission fragments and other ionizing radiation. The amount of linear momentum imparted to the fissioning nucleus by the incident neutron can be inferred by measu…
▽ More
The Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) collaboration has performed measurements with a fission time projection chamber (fissionTPC) to study the fission process by reconstructing full three-dimensional tracks of fission fragments and other ionizing radiation. The amount of linear momentum imparted to the fissioning nucleus by the incident neutron can be inferred by measuring the opening angle between the fission fragments. Using this measured linear momentum, fission fragment angular distributions can be converted to the center-of-mass frame for anisotropy measurements. Angular anisotropy is an important experimental observable for understanding the quantum mechanical state of the fissioning nucleus and vital to determining detection efficiency for cross section measurements. Neutron linear momentum transfer to fissioning $^{235}$U, $^{238}$U, and $^{239}$Pu and fission fragment angular anisotropy of $^{235}$U and $^{238}$U as a function of neutron energies in the range 130 keV--250 MeV are presented.
△ Less
Submitted 25 January, 2020;
originally announced January 2020.
-
Measurement of the normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio from threshold to 30 MeV with the fission Time Projection Chamber
Authors:
R. J. Casperson,
D. M. Asner,
J. Baker,
R. G. Baker,
J. S. Barrett,
N. S. Bowden,
C. Brune,
J. Bundgaard,
E. Burgett,
D. A. Cebra,
T. Classen,
M. Cunningham,
J. Deaven,
D. L. Duke,
I. Ferguson,
J. Gearhart,
V. Geppert-Kleinrath,
U. Greife,
S. Grimes,
E. Guardincerri,
U. Hager,
C. Hagmann,
M. Heffner,
D. Hensle,
N. Hertel
, et al. (39 additional authors not shown)
Abstract:
The normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio has been measured using the NIFFTE fission Time Projection Chamber from the reaction threshold to $30$~MeV. The fissionTPC is a two-volume MICROMEGAS time projection chamber that allows for full three-dimensional reconstruction of fission-fragment ionization profiles from neutron-induced fission. The measurement was performed at the…
▽ More
The normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio has been measured using the NIFFTE fission Time Projection Chamber from the reaction threshold to $30$~MeV. The fissionTPC is a two-volume MICROMEGAS time projection chamber that allows for full three-dimensional reconstruction of fission-fragment ionization profiles from neutron-induced fission. The measurement was performed at the Los Alamos Neutron Science Center, where the neutron energy is determined from neutron time-of-flight. The $^{238}$U(n,f)/$^{235}$U(n,f) ratio reported here is the first cross section measurement made with the fissionTPC, and will provide new experimental data for evaluation of the $^{238}$U(n,f) cross section, an important standard used in neutron-flux measurements. Use of a development target in this work prevented the determination of an absolute normalization, to be addressed in future measurements. Instead, the measured cross section ratio has been normalized to ENDF/B-VIII.$β$5 at 14.5 MeV.
△ Less
Submitted 23 February, 2018;
originally announced February 2018.
-
Performance of a MICROMEGAS-based TPC in a high-energy neutron beam
Authors:
Lucas Snyder,
Brett Manning,
Nathaniel S. Bowden,
Jeremy Bundgaard,
Robert J. Casperson,
Daniel A. Cebra,
Timothy Classen,
Dana L. Duke,
Joshua Gearhart,
Uwe Greife,
Christian Hagmann,
Michael Heffner,
David Hensle,
Daniel Higgins,
Donald Isenhower,
Jonathan King,
Jennifer L. Klay,
Verena Geppert-Kleinrath,
Walter Loveland,
Joshua A. Magee,
Michael P. Mendenhall,
Samuele Sangiorgio,
Brandon Seilhan,
Kyle T. Schmitt,
Fredrik Tovesson
, et al. (5 additional authors not shown)
Abstract:
The MICROMEGAS (MICRO-MEsh GAseous Structure) charge amplification structure has found wide use in many detection applications, especially as a gain stage for the charge readout of Time Projection Chambers (TPCs). Here we report on the behavior of a MICROMEGAS TPC when operated in a high-energy (up to 800 MeV) neutron beam. It is found that neutron-induced reactions can cause discharges in some dr…
▽ More
The MICROMEGAS (MICRO-MEsh GAseous Structure) charge amplification structure has found wide use in many detection applications, especially as a gain stage for the charge readout of Time Projection Chambers (TPCs). Here we report on the behavior of a MICROMEGAS TPC when operated in a high-energy (up to 800 MeV) neutron beam. It is found that neutron-induced reactions can cause discharges in some drift gas mixtures that are stable in the absence of the neutron beam. The discharges result from recoil ions close to the MICROMEGAS that deposit high specific ionization density and have a limited diffusion time. For a binary drift gas, increasing the percentage of the molecular component (quench gas) relative to the noble component and operating at lower pressures generally improves stability.
△ Less
Submitted 4 December, 2017;
originally announced December 2017.
-
Fission Fragment Angular Anisotropy in Neutron-Induced Fission of $^{235}$U Measured with a Time Projection Chamber
Authors:
V. Geppert-Kleinrath,
F. Tovesson,
J. S. Barrett,
N. S. Bowden,
J. Bundgaard,
R. J. Casperson,
D. A. Cebra,
T. Classen,
M. Cunningham,
D. L. Duke,
J. Gearhart,
U. Greife,
E. Guardincerri,
C. Hagmann,
M. Heffner,
D. Hensle,
D. Higgins,
L. D. Isenhower,
J. King,
J. L. Klay,
W. Loveland,
J. A. Magee,
B. Manning,
M. P. Mendenhall,
J. Ruz
, et al. (11 additional authors not shown)
Abstract:
Fission fragment angular distributions can provide an important constraint on fission theory, improving predictive fission codes, and are a prerequisite for a precise ratio cross section measurement. Available anisotropy data is sparse, especially at neutron energies above 5 MeV. For the first time, a three-dimensional tracking detector is employed to study fragment emission angles and provide a d…
▽ More
Fission fragment angular distributions can provide an important constraint on fission theory, improving predictive fission codes, and are a prerequisite for a precise ratio cross section measurement. Available anisotropy data is sparse, especially at neutron energies above 5 MeV. For the first time, a three-dimensional tracking detector is employed to study fragment emission angles and provide a direct measurement of angular anisotropy. The Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) collaboration has deployed the fission time projection chamber (fissionTPC) to measure nuclear data with unprecedented precision. The fission fragment anisotropy of $^{235}$U has been measured over a wide range of incident neutron energies from 180 keV to 200 MeV; a careful study of the systematic uncertainties complement the data.
△ Less
Submitted 15 August, 2019; v1 submitted 2 October, 2017;
originally announced October 2017.
-
A Time Projection Chamber for High Accuracy and Precision Fission Cross Section Measurements
Authors:
NIFFTE Collaboration,
M. Heffner,
D. M. Asner,
R. G. Baker,
J. Baker,
S. Barrett,
C. Brune,
J. Bundgaard,
E. Burgett,
D. Carter,
M. Cunningham,
J. Deaven,
D. L. Duke,
U. Greife,
S. Grimes,
U. Hager,
N. Hertel,
T. Hill,
D. Isenhower,
K. Jewell,
J. King,
J. L. Klay,
V. Kleinrath,
N. Kornilov,
R. Kudo
, et al. (25 additional authors not shown)
Abstract:
The fission Time Projection Chamber (fissionTPC) is a compact (15 cm diameter) two-chamber MICROMEGAS TPC designed to make precision cross section measurements of neutron-induced fission. The actinide targets are placed on the central cathode and irradiated with a neutron beam that passes axially through the TPC inducing fission in the target. The 4$π$ acceptance for fission fragments and complete…
▽ More
The fission Time Projection Chamber (fissionTPC) is a compact (15 cm diameter) two-chamber MICROMEGAS TPC designed to make precision cross section measurements of neutron-induced fission. The actinide targets are placed on the central cathode and irradiated with a neutron beam that passes axially through the TPC inducing fission in the target. The 4$π$ acceptance for fission fragments and complete charged particle track reconstruction are powerful features of the fissionTPC which will be used to measure fission cross sections and examine the associated systematic errors. This paper provides a detailed description of the design requirements, the design solutions, and the initial performance of the fissionTPC.
△ Less
Submitted 26 March, 2014;
originally announced March 2014.
-
Targets for Precision Measurements
Authors:
W. Loveland,
L. Yao,
David M. Asner,
R. G. Baker,
J. Bundgaard,
E. Burgett,
M. Cunningham,
J. Deaven,
D. L. Duke,
U. Greife,
S. Grimes,
M. Heffer,
T. Hill,
D. Isenhower,
J. L. Klay,
V. Kleinrath,
N. Kornilov,
A. B. Laptev,
T. N. Massey,
R. Meharchand,
H. Qu,
J. Ruz,
S. Sangiorgio,
B. Selhan,
L. Snyder
, et al. (9 additional authors not shown)
Abstract:
The general properties needed in targets (sources) for high precision, high accuracy measurements are reviewed. The application of these principles to the problem of develo** targets for the Fission TPC is described. Longer term issues, such as the availability of actinide materials, improved knowledge of energy losses and straggling and the stability of targets during irradiation are also discu…
▽ More
The general properties needed in targets (sources) for high precision, high accuracy measurements are reviewed. The application of these principles to the problem of develo** targets for the Fission TPC is described. Longer term issues, such as the availability of actinide materials, improved knowledge of energy losses and straggling and the stability of targets during irradiation are also discussed.
△ Less
Submitted 9 March, 2013;
originally announced March 2013.