-
Progress on the design of a perpendicularly biased 2nd harmonic cavity for the Fermilab Booster
Authors:
R. L. Madrak,
J. E. Dey,
K. L. Duel,
J. C. Kuharik,
W. A. Pellico,
J. S. Reid,
G. Romanov,
M. Slabaugh,
D. Sun,
C. Y. Tan,
I. Terechkine
Abstract:
A perpendicularly biased 2nd harmonic cavity is being designed and built for the Fermilab Booster. Its purpose is to flatten the bucket at injection and thus change the longitudinal beam distribution to decrease space charge effects. It can also help at extraction. The cavity frequency range is 76 - 106 MHz. The power amplifier will be built using the Y567B tetrode, which is also used for the fund…
▽ More
A perpendicularly biased 2nd harmonic cavity is being designed and built for the Fermilab Booster. Its purpose is to flatten the bucket at injection and thus change the longitudinal beam distribution to decrease space charge effects. It can also help at extraction. The cavity frequency range is 76 - 106 MHz. The power amplifier will be built using the Y567B tetrode, which is also used for the fundamental mode cavities in the Fermilab Booster. We discuss recent progress on the cavity, the biasing solenoid design and plans for testing the tuner's garnet material.
△ Less
Submitted 27 December, 2017;
originally announced December 2017.
-
The Linac Laser Notcher For The Fermilab Booster
Authors:
David E. Johnson,
Kevin Laurence Duel,
Matthew Gardner,
Todd R. Johnson,
David Slimmer,
Sreenivas Patil,
Jason Tafoya
Abstract:
In synchrotron machines, the beam extraction is accomplished by a combination of septa and kicker magnets which deflect the beam from an accelerator into another. Ideally the kicker field must rise/fall in between the beam bunches. However, in reality, an intentional beam-free time region (aka "notch") is created on the beam pulse to assure that the beam can be extracted with minimal losses. In th…
▽ More
In synchrotron machines, the beam extraction is accomplished by a combination of septa and kicker magnets which deflect the beam from an accelerator into another. Ideally the kicker field must rise/fall in between the beam bunches. However, in reality, an intentional beam-free time region (aka "notch") is created on the beam pulse to assure that the beam can be extracted with minimal losses. In the case of the Fermilab Booster, the notch is created in the ring near injection energy by the use of fast kickers which deposit the beam in a shielded collimation region within the accelerator tunnel. With increasing beam power it is desirable to create this notch at the lowest possible energy to minimize activation. The Fermilab Proton Improvement Plan (PIP) initiated an R&D project to build a laser system to create the notch within a linac beam pulse at 750 keV. This talk will describe the concept for the laser notcher and discuss our current status, commissioning results, and future plans.
△ Less
Submitted 13 April, 2017;
originally announced April 2017.
-
Instrumentation Developments and Beam Studies for the Fermilab Proton Improvement Plan LINAC Upgrade and New RFQ Front-End
Authors:
Victor E. Scarpine,
Cheng-Yang Tan,
Pat R. Karns,
Daniel S. Bollinger,
Kevin L. Duel,
Nathan Eddy,
Ning Lui,
Alexei Semenov,
Raymond E. Tomlin,
William A. Pellico
Abstract:
Fermilab is develo** a Proton Improvement Plan (PIP) to increase throughput of its proton source. The plan addresses hardware modifications to increase repetition rate and improve beam loss while ensuring viable operation of the proton source through 2025. The first phase of the PIP will enable the Fermilab proton source to deliver 1.8e17 protons per hour by mid-2013. As part of this initial upg…
▽ More
Fermilab is develo** a Proton Improvement Plan (PIP) to increase throughput of its proton source. The plan addresses hardware modifications to increase repetition rate and improve beam loss while ensuring viable operation of the proton source through 2025. The first phase of the PIP will enable the Fermilab proton source to deliver 1.8e17 protons per hour by mid-2013. As part of this initial upgrade, Fermilab plans to install a new front-end consisting of dual H- ion sources and a 201 MHz pulsed RFQ. This paper will present beam studies measurements of this new front-end and discuss new beam instrumentation upgrades for the Fermilab linac.
△ Less
Submitted 29 August, 2014;
originally announced August 2014.
-
Secondary Electron Yield Measurements of Fermilab's Main Injector Vacuum Vessel
Authors:
D. J. Scott,
D. Capista,
K. L. Duel,
R. M. Zwaska,
S. Greenwald,
W. Hartung,
Y. Li,
T. P. Moore,
M. A. Palmer,
R. Kirby,
M. Pivi,
L. Wang
Abstract:
We discuss the progress made on a new installation in Fermilab's Main Injector that will help investigate the electron cloud phenomenon by making direct measurements of the secondary electron yield (SEY) of samples irradiated in the accelerator. In the Project X upgrade the Main Injector will have its beam intensity increased by a factor of three compared to current operations. This may result in…
▽ More
We discuss the progress made on a new installation in Fermilab's Main Injector that will help investigate the electron cloud phenomenon by making direct measurements of the secondary electron yield (SEY) of samples irradiated in the accelerator. In the Project X upgrade the Main Injector will have its beam intensity increased by a factor of three compared to current operations. This may result in the beam being subject to instabilities from the electron cloud. Measured SEY values can be used to further constrain simulations and aid our extrapolation to Project X intensities. The SEY test-stand, developed in conjunction with Cornell and SLAC, is capable of measuring the SEY from samples using an incident electron beam when the samples are biased at different voltages. We present the design and manufacture of the test-stand and the results of initial laboratory tests on samples prior to installation.
△ Less
Submitted 29 January, 2013;
originally announced January 2013.
-
The FNAL injector upgrade
Authors:
C. Y. Tan,
D. S. Bollinger,
K. L. Duel,
J. R. Lackey,
W. A. Pellico
Abstract:
The present FNAL H- injector has been operational since the 1970s and consists of two magnetron H- sources and two 750 keV Cockcroft-Walton Accelerators. In the upgrade, both slit-type magnetron sources will be replaced with circular aperture sources, and the Cockcroft-Waltons with a 200 MHz RFQ (radio frequency quadrupole). Operational experience at BNL (Brookhaven National Laboratory) has shown…
▽ More
The present FNAL H- injector has been operational since the 1970s and consists of two magnetron H- sources and two 750 keV Cockcroft-Walton Accelerators. In the upgrade, both slit-type magnetron sources will be replaced with circular aperture sources, and the Cockcroft-Waltons with a 200 MHz RFQ (radio frequency quadrupole). Operational experience at BNL (Brookhaven National Laboratory) has shown that the upgraded source and RFQ will be more reliable, improve beam quality and require less manpower than the present system.
△ Less
Submitted 15 August, 2012;
originally announced August 2012.