-
Multiple scattering of channeled and non-channeled positively charged particles in bent monocrystalline silicon
Authors:
W. Scandale,
G. Arduini,
F. Cerutti,
L. S. Esposito,
M. Garattini,
S. Gilardoni,
R. Losito,
A. Masi,
D. Mirarchi,
S. Montesano,
S. Redaelli,
R. Rossi,
G. Smirnov,
L. Burmistrov,
S. Dubos,
V. Puill,
A. Stocchi,
L. Bandiera,
V. Guidi,
A. Mazzolari,
M. Romagnoni,
F. Murtas,
F. Addesa,
G. Cavoto,
F. Iacoangeli
, et al. (17 additional authors not shown)
Abstract:
We present the results of an experimental study of multiple scattering of positively charged high energy particles in bent samples of monocrystalline silicon. This work confirms the recently discovered effect of a strong reduction in the rms multiple scattering angle of particles channeled in the silicon (111) plane. The effect is observed in the plane orthogonal to the bending plane. We show in d…
▽ More
We present the results of an experimental study of multiple scattering of positively charged high energy particles in bent samples of monocrystalline silicon. This work confirms the recently discovered effect of a strong reduction in the rms multiple scattering angle of particles channeled in the silicon (111) plane. The effect is observed in the plane orthogonal to the bending plane. We show in detail the influence of angular constraints on the magnitude of the effect. Comparison of the multiple scattering process at different energies indicates a violation of the law of inverse proportionality of the rms angle of channeled particles with energy. By increasing the statistics, we have improved the results of multiple scattering measurements for particles moving, but not channeled, in silicon crystals.
△ Less
Submitted 31 January, 2022; v1 submitted 24 January, 2022;
originally announced January 2022.
-
Double-crystal measurements at the CERN SPS
Authors:
W. Scandale,
G. Arduini,
F. Cerutti,
M. D'Andrea,
L. S. Esposito,
M. Garattini,
S. Gilardoni,
D. Mirarchi,
S. Montesano,
A. Natochii,
S. Redaelli,
R. Rossi,
G. I. Smirnov,
L. Burmistrov,
S. Dubos,
V. Puill,
A. Stocchi,
F. Addesa,
F. Murtas,
F. Galluccio,
A. D. Kovalenko,
A. M. Taratin,
A. S. Denisov,
Yu. A. Gavrikov,
Yu. M. Ivanov
, et al. (13 additional authors not shown)
Abstract:
The UA9 setup, installed in the Super Proton Synchrotron (SPS) at CERN, was exploited for a proof of principle of the double-crystal scenario, proposed to measure the electric and the magnetic moments of short-lived baryons in a high-energy hadron collider, such as the Large Hadron Collider (LHC). Linear and angular actuators were used to position the crystals and establish the required beam confi…
▽ More
The UA9 setup, installed in the Super Proton Synchrotron (SPS) at CERN, was exploited for a proof of principle of the double-crystal scenario, proposed to measure the electric and the magnetic moments of short-lived baryons in a high-energy hadron collider, such as the Large Hadron Collider (LHC). Linear and angular actuators were used to position the crystals and establish the required beam configuration. Timepix detectors and high-sensitivity Beam Loss Monitors were exploited to observe the deflected beams. Linear and angular scans allowed exploring the particle interactions with the two crystals and recording their efficiency. The measured values of the beam trajectories, profiles and of the channeling efficiency agree with the results of a Monte-Carlo simulation.
△ Less
Submitted 26 March, 2021;
originally announced March 2021.
-
Single photon emission from droplet epitaxial quantum dots in the standard telecom window around a wavelength of 1.55 $μ$m
Authors:
N. Ha,
T. Mano,
S. Dubos,
T. Kuroda,
Y. Sakuma,
K. Sakoda
Abstract:
We study the luminescence dynamics of telecom wavelength InAs quantum dots grown on InP(111)A by droplet epitaxy. The use of the ternary alloy InAlGaAs as a barrier material leads to photon emission in the 1.55 $μ$m telecom C-band. The luminescence decay is well described in terms of the theoretical interband transition strength without the impact of nonradiative recombination. The intensity autoc…
▽ More
We study the luminescence dynamics of telecom wavelength InAs quantum dots grown on InP(111)A by droplet epitaxy. The use of the ternary alloy InAlGaAs as a barrier material leads to photon emission in the 1.55 $μ$m telecom C-band. The luminescence decay is well described in terms of the theoretical interband transition strength without the impact of nonradiative recombination. The intensity autocorrelation function shows clear anti-bunching photon statistics. The results suggest that our quantum dots are useful for constructing a practical source of single photons and quantum entangled photon pairs.
△ Less
Submitted 20 January, 2020;
originally announced January 2020.
-
Double-crystal setup measurements at the CERN SPS
Authors:
W. Scandale,
F. Cerutti,
L. S. Esposito,
M. Garattini,
S. Gilardoni,
S. Montesano,
R. Rossi,
L. Burmistrov,
S. Dubos,
A. Natochii,
V. Puill,
A. Stocchi,
V. Zhovkovska,
F. Murtas,
F. Addesa,
F. Iacoangeli,
F. Galluccio,
A. D. Kovalenko,
A. M. Taratin,
G. I. Smirnov,
A. S. Denisov,
Yu. A. Gavrikov,
Yu. M. Ivanov,
L. P. Lapina,
L. G. Malyarenko
, et al. (11 additional authors not shown)
Abstract:
In this paper, we discuss an experimental layout for the two-crystals scenario at the Super Proton Synchrotron (SPS) accelerator. The research focuses on a fixed target setup at the circulating machine in a frame of the Physics Beyond Colliders (PBC) project at CERN. The UA9 experiment at the SPS serves as a testbench for the proof of concept, which is planning to be projected onto the Large Hadro…
▽ More
In this paper, we discuss an experimental layout for the two-crystals scenario at the Super Proton Synchrotron (SPS) accelerator. The research focuses on a fixed target setup at the circulating machine in a frame of the Physics Beyond Colliders (PBC) project at CERN. The UA9 experiment at the SPS serves as a testbench for the proof of concept, which is planning to be projected onto the Large Hadron Collider (LHC) scale. The presented in the text configuration was used for the quantitative characterization of the deflected particle beam by a pair of bent silicon crystals. For the first time in the double-crystal configuration, a particle deflection efficiency by the second crystal of $0.188 \pm 3 \cdot 10^{-5}$ and $0.179 \pm 0.013$ was measured on the accelerator by means of the Timepix detector and Beam Loss Monitor (BLM) respectively. In this setup, a wide range angular scan allowed a possibility to \textit{in situ} investigate different crystal working regimes (channeling, volume reflection, etc.), and to measure a bent crystal torsion.
△ Less
Submitted 6 September, 2019;
originally announced September 2019.
-
Commissioning and operation of the Cherenkov detector for proton Flux Measurement of the UA9 Experiment
Authors:
F. M. Addesa,
L. Burmistrov,
D. Breton,
G. Cavoto,
V. Chaumat,
S. Dubos,
L. Esposito,
F. Galluccio,
M. Garattini,
F. Iacoangeli,
J. Maalmi,
D. Mirarchi,
A. Natochii,
V. Puill,
R. Rossi,
W. Scandale,
S. Montesano,
A. Stocchi
Abstract:
The UA9 Experiment at CERN-SPS investigates channeling processes in bent silicon crystals with the aim to manipulate hadron beams. Monitoring and characterization of channeled beams in the high energy accelerators environment ideally requires in-vacuum and radiation hard detectors. For this purpose the Cherenkov detector for proton Flux Measurement (CpFM) was designed and developed. It is based on…
▽ More
The UA9 Experiment at CERN-SPS investigates channeling processes in bent silicon crystals with the aim to manipulate hadron beams. Monitoring and characterization of channeled beams in the high energy accelerators environment ideally requires in-vacuum and radiation hard detectors. For this purpose the Cherenkov detector for proton Flux Measurement (CpFM) was designed and developed. It is based on thin fused silica bars in the beam pipe vacuum which intercept charged particles and generate Cherenkov light. The first version of the CpFM is installed since 2015 in the crystal-assisted collimation setup of the UA9 experiment. In this paper the procedures to make the detector operational and fully integrated in the UA9 setup are described. The most important standard operations of the detector are presented. They have been used to commission and characterize the detector, providing moreover the measurement of the integrated channeled beam profile and several functionality tests as the determination of the crystal bending angle.
The calibration has been performed with Lead (Pb) and Xenon (Xe) beams and the results are applied to the flux measurement discussed here in detail.
△ Less
Submitted 12 April, 2019;
originally announced April 2019.
-
Fast-neutron induced background in LaBr3:Ce detectors
Authors:
J. Kiener,
V. Tatischeff,
I. Deloncle,
N. de Séréville,
P. Laurent,
C. Blondel,
M. Chabot,
R. Chipaux,
A. Coc,
S. Dubos,
A. Gostojic,
N. Goutev,
C. Hamadache,
F. Hammache,
B. Horeau,
O. Limousin,
S. Ouichaoui,
G. Prévot,
R. Rodríguez-Gasén,
M. S. Yavahchova
Abstract:
The response of a scintillation detector with a cylindrical 1.5-inch LaBr3:Ce crystal to incident neutrons has been measured in the energy range En = 2-12 MeV. Neutrons were produced by proton irradiation of a Li target at Ep = 5-14.6 MeV with pulsed proton beams. Using the time-of-flight information between target and detector, energy spectra of the LaBr3:Ce detector resulting from fast neutron i…
▽ More
The response of a scintillation detector with a cylindrical 1.5-inch LaBr3:Ce crystal to incident neutrons has been measured in the energy range En = 2-12 MeV. Neutrons were produced by proton irradiation of a Li target at Ep = 5-14.6 MeV with pulsed proton beams. Using the time-of-flight information between target and detector, energy spectra of the LaBr3:Ce detector resulting from fast neutron interactions have been obtained at 4 different neutron energies. Neutron-induced gamma rays emitted by the LaBr3:Ce crystal were also measured in a nearby Ge detector at the lowest proton beam energy. In addition, we obtained data for neutron irradiation of a large-volume high-purity Ge detector and of a NE-213 liquid scintillator detector, both serving as monitor detectors in the experiment. Monte-Carlo type simulations for neutron interactions in the liquid scintillator, the Ge and LaBr3:Ce crystals have been performed and compared with measured data. Good agreement being obtained with the data, we present the results of simulations to predict the response of LaBr3:Ce detectors for a range of crystal sizes to neutron irradiation in the energy range En = 0.5-10 MeV
△ Less
Submitted 1 December, 2015;
originally announced December 2015.
-
ORIGAMIX, a CdTe-based spectro-imager development for nuclear applications
Authors:
S. Dubos,
H. Lemaire,
S. Schanne,
O. Limousin,
F. Carrel,
V. Schoepff,
C. Blondel
Abstract:
The Astrophysics Division of CEA Saclay has a long history in the development of CdTe based pixelated detection planes for X and gamma-ray astronomy, with time-resolved imaging and spectrometric capabilities. The last generation, named Caliste HD, is an all-in-one modular instrument that fulfills requirements for space applications. Its full-custom front-end electronics is designed to work over a…
▽ More
The Astrophysics Division of CEA Saclay has a long history in the development of CdTe based pixelated detection planes for X and gamma-ray astronomy, with time-resolved imaging and spectrometric capabilities. The last generation, named Caliste HD, is an all-in-one modular instrument that fulfills requirements for space applications. Its full-custom front-end electronics is designed to work over a large energy range from 2 keV to 1 MeV with excellent spectroscopic performances, in particular between 10 and 100 keV (0.56 keV FWHM and 0.67 keV FWHM at 13.9 and 59.5 keV). In the frame of the ORIGAMIX project, a consortium based on research laboratories and industrials has been settled in order to develop a new generation of gamma camera. The aim is to develop a system based on the Caliste architecture for post-accidental interventions or homeland security, but integrating new properties (advanced spectrometry, hybrid working mode) and suitable for industry. A first prototype was designed and tested to acquire feedback for further developments. In this study, we particularly focused on spectrometric performances with high energies and high fluxes. Therefore, our device was exposed to energies up to 700 keV (133Ba, 137Cs) and we measured the evolution of energy resolution (0.96 keV at 80 keV, 2.18 keV at 356 keV, 3.33 keV at 662 keV). Detection efficiency decreases after 150 keV, as Compton effect becomes dominant. However, CALISTE is also designed to handle multiple events, enabling Compton scattering reconstruction, which can drastically improve detection efficiencies and dynamic range for higher energies up to 1408 keV (22Na, 60Co, 152Eu) within a 1-mm thick detector. In particular, such spectrometric performances obtained with 152Eu and 60Co were never measured before with this kind of detector.
△ Less
Submitted 5 February, 2015;
originally announced February 2015.