-
The dual-path hypothesis for the emergence of anosognosia in Alzheimer's disease
Authors:
Katia Andrade,
Thomas Guiyesse,
Takfarinas Medani,
Etienne Koechlin,
Dimitrios Pantazis,
Bruno Dubois
Abstract:
Although neurocognitive models have been proposed to explain anosognosia in Alzheimer's disease (AD), the neural cascade responsible for its origin in the human brain remains unknown. Here, we build on a mechanistic dual-path hypothesis that brings error-monitoring and emotional processing systems as key elements for self-awareness, with distinct impacts on the emergence of anosognosia in AD. Proc…
▽ More
Although neurocognitive models have been proposed to explain anosognosia in Alzheimer's disease (AD), the neural cascade responsible for its origin in the human brain remains unknown. Here, we build on a mechanistic dual-path hypothesis that brings error-monitoring and emotional processing systems as key elements for self-awareness, with distinct impacts on the emergence of anosognosia in AD. Proceeding from the notion of anosognosia as a dimensional syndrome, ranging from the lack of concern about one's own deficits (i.e., anosodiaphoria) to the complete lack of awareness of deficits, our hypothesis states that (i) unawareness of deficits would result from a failure in the error-monitoring system, whereas (ii) anosodiaphoria would more likely result from an imbalance between emotional processing and error-monitoring systems. In the first case, a synaptic failure in the error-monitoring system, in which the cingulate cortex plays a major role, would have a negative impact on error (or deficits) awareness, preventing patients from becoming aware of their condition. In the second case, an impairment in the emotional processing system, in which the amygdala and orbitofrontal cortex play a major role, would prevent patients from monitoring the internal milieu for relevant errors (or deficits) and assigning appropriate value to them, thus biasing their impact on the error-monitoring system. Our hypothesis stems from two scientific premises. One comes from preliminary results in AD patients showing a synaptic failure in the error-monitoring system and decline of awareness at the time of diagnosis. Another comes from the somatic marker hypothesis, which proposes that emotional signals are critical to adaptive behavior. Further exploration will be of great interest to illuminate the foundations of self-awareness and improve our understanding of the underlying mechanisms of anosognosia in AD.
△ Less
Submitted 25 March, 2023; v1 submitted 11 February, 2023;
originally announced February 2023.
-
Interdicting attack plans with boundedly-rational players and multiple attackers: An adversarial risk analysis approach
Authors:
Eric B. DuBois,
Ashley Peper,
Laura A. Albert
Abstract:
Cybersecurity planning supports the selection of and implementation of security controls in resource-constrained settings to manage risk. Doing so requires considering adaptive adversaries with different levels of strategic sophistication in modeling efforts to support risk management. However, most models in the literature only consider rational or non-strategic adversaries. Therefore, we study h…
▽ More
Cybersecurity planning supports the selection of and implementation of security controls in resource-constrained settings to manage risk. Doing so requires considering adaptive adversaries with different levels of strategic sophistication in modeling efforts to support risk management. However, most models in the literature only consider rational or non-strategic adversaries. Therefore, we study how to inform defensive decision-making to mitigate the risk from boundedly rational players, with a particular focus on making integrated, interdependent planning decisions. To achieve this goal, we introduce a modeling framework for selecting a portfolio of security mitigations that interdict adversarial attack plans that uses a structured approach for risk analysis. Our approach adapts adversarial risk analysis and cognitive hierarchy theory to consider a maximum reliability path interdiction problem with a single defender and multiple attackers who have different goals and levels of strategic sophistication. Instead of enumerating all possible attacks and defenses, we introduce a solution technique based on integer programming and approximation algorithms to iteratively solve the defender's and attackers' problems. A case study illustrates the proposed models and provides insights into defensive planning.
△ Less
Submitted 3 February, 2023;
originally announced February 2023.
-
A Cryogenic Sapphire Resonator Oscillator with 1e-16 mid-term fractional frequency stability
Authors:
Christophe Fluhr,
Benoit Dubois,
Claudio E. Calosso,
Francois Vernotte,
Enrico Rubiola,
Vincent Giordano
Abstract:
We report in this letter the outstanding frequency stability performances of an autonomous cryogenique sapphire oscillator presenting a flicker frequency noise floor below 2e-16 near 1,000 s of integration time and a long term Allan Deviation (ADEV) limited by a random walk process of 1e-18/sqr(tau). The frequency stability qualification at this level called for the implementation of sophisticated…
▽ More
We report in this letter the outstanding frequency stability performances of an autonomous cryogenique sapphire oscillator presenting a flicker frequency noise floor below 2e-16 near 1,000 s of integration time and a long term Allan Deviation (ADEV) limited by a random walk process of 1e-18/sqr(tau). The frequency stability qualification at this level called for the implementation of sophisticated instrumentation associated with ultra-stable frequency references and ad hoq averaging and correlation methods.
△ Less
Submitted 12 October, 2022;
originally announced October 2022.
-
Reliability and Reproducibility of the Cryogenic Sapphire Oscillator Technology
Authors:
Christophe Fluhr,
Benoît Dubois,
Guillaume Le Tetu,
Valerie Soumann,
Julien Paris,
Enrico Rubiola,
Vincent Giordano
Abstract:
The cryogenic sapphire oscillator (CSO) is a highly specialized machine, which delivers a reference signal exhibiting the lowest frequency fluctuations. For the best units, the Allan deviation (ADEV) is <1e-15 for integration time between 1 and 10,000 s, with a drift <1e-14 in one day.The oscillator is based on a sapphire monocrystal resonating at 10 GHz in a whispering-gallery mode, cooled at 6 K…
▽ More
The cryogenic sapphire oscillator (CSO) is a highly specialized machine, which delivers a reference signal exhibiting the lowest frequency fluctuations. For the best units, the Allan deviation (ADEV) is <1e-15 for integration time between 1 and 10,000 s, with a drift <1e-14 in one day.The oscillator is based on a sapphire monocrystal resonating at 10 GHz in a whispering-gallery mode, cooled at 6 K for highest Q-factor and zero thermal coefficient. We report on the progress accomplished implementing eleven CSOs in about 10 years since the first sample delivered to the ESA station in Argentina.
Short-term stability is improved by a factor of 3-10, depending on the integration time, and the refrigerator's electric power is reduced to 3 kW. Frequency stability and overall performances are reproducible, with unattended operation between scheduled maintenance every two years. The CSO is suitable to scientific applications requiring extreme frequency stability with reliable long-term operation. For example, the flywheel for primary frequency standards, the ground segment of GNSS, astrometry, VLBI, and radio astronomy stations.
△ Less
Submitted 11 October, 2022;
originally announced October 2022.
-
The SuperCam Infrared Spectrometer for the Perseverance Rover of the Mars2020 mission
Authors:
Thierry Fouchet,
Jean-Michel Reess,
Franck Montmessin,
Rafik Hassen-Khodja,
Napoléon Nguyen-Tuong,
Olivier Humeau,
Sophie Jacquinod,
Laurent Lapauw,
Jérôme Parisot,
Marion Bonafous,
Pernelle Bernardi,
Frédéric Chapron,
Alexandre Jeanneau,
Claude Collin,
Didier Zeganadin,
Patricia Nibert,
Sadok Abbaki,
Christophe Montaron,
Cyrille Blanchard,
Vartan Arslanyan,
Ourdya Achelhi,
Claudine Colon,
Clément Royer,
Vincent Hamm,
Mehdi Bouzit
, et al. (16 additional authors not shown)
Abstract:
We present the Infrared spectrometer of SuperCam Instrument Suite that enables the Mars 2020 Perseverance Rover to study remotely the Martian mineralogy within the Jezero crater. The SuperCam IR spectrometer is designed to acquire spectra in the 1.3-2.6 $μ$m domain at a spectral resolution ranging from 5 to 20~nm. The field-of-view of 1.15 mrad, is coaligned with the boresights of the other remote…
▽ More
We present the Infrared spectrometer of SuperCam Instrument Suite that enables the Mars 2020 Perseverance Rover to study remotely the Martian mineralogy within the Jezero crater. The SuperCam IR spectrometer is designed to acquire spectra in the 1.3-2.6 $μ$m domain at a spectral resolution ranging from 5 to 20~nm. The field-of-view of 1.15 mrad, is coaligned with the boresights of the other remote-sensing techniques provided by SuperCam: laser-induced breakdown spectroscopy, remote time-resolved Raman and luminescence spectroscopies, and visible reflectance spectroscopy, and micro-imaging. The IR spectra can be acquired from the robotic-arm workspace to long-distances, in order to explore the mineralogical diversity of the Jezero crater, guide the Perseverance Rover in its sampling task, and to document the samples' environment. We present the design, the performance, the radiometric calibration, and the anticipated operations at the surface of Mars.
△ Less
Submitted 28 October, 2021;
originally announced October 2021.
-
SPIRou: nIR velocimetry & spectropolarimetry at the CFHT
Authors:
J. -F. Donati,
D. Kouach,
C. Moutou,
R. Doyon,
X. Delfosse,
E. Artigau,
S. Baratchart,
M. Lacombe,
G. Barrick,
G. Hebrard,
F. Bouchy,
L. Saddlemyer,
L. Pares,
P. Rabou,
Y. Micheau,
F. Dolon,
V. Reshetov,
Z. Challita,
A. Carmona,
N. Striebig,
S. Thibault,
E. Martioli,
N. Cook,
P. Fouque,
T. Vermeulen
, et al. (41 additional authors not shown)
Abstract:
This paper presents an overview of SPIRou, the new-generation near-infrared spectropolarimeter / precision velocimeter recently installed on the 3.6-m Canada-France-Hawaii Telescope (CFHT). Starting from the two main science goals, namely the quest for planetary systems around nearby M dwarfs and the study of magnetized star / planet formation, we outline the instrument concept that was designed t…
▽ More
This paper presents an overview of SPIRou, the new-generation near-infrared spectropolarimeter / precision velocimeter recently installed on the 3.6-m Canada-France-Hawaii Telescope (CFHT). Starting from the two main science goals, namely the quest for planetary systems around nearby M dwarfs and the study of magnetized star / planet formation, we outline the instrument concept that was designed to efficiently address these forefront topics, and detail the in-lab and on-sky instrument performances measured throughout the intensive testing phase that SPIRou was submitted to before passing the final acceptance review in early 2019 and initiating science observations. With a central position among the newly started programmes, the SPIRou Legacy Survey (SLS) Large Programme was allocated 300 CFHT nights until at least mid 2022. We also briefly describe a few of the first results obtained in the various science topics that SPIRou started investigating, focusing in particular on planetary systems of nearby M dwarfs, transiting exoplanets and their atmospheres, magnetic fields of young stars, but also on alternate science goals like the atmospheres of M dwarfs and the Earth's atmosphere. We finally conclude on the essential role that SPIRou and the CFHT can play in coordination with forthcoming major facilities like the JWST, the ELTs, PLATO and ARIEL over the decade.
△ Less
Submitted 20 August, 2020;
originally announced August 2020.
-
Accuracy of MRI Classification Algorithms in a Tertiary Memory Center Clinical Routine Cohort
Authors:
Alexandre Morin,
Jorge Samper-González,
Anne Bertrand,
Sebastian Stroer,
Didier Dormont,
Aline Mendes,
Pierrick Coupé,
Jamila Ahdidan,
Marcel Lévy,
Dalila Samri,
Harald Hampel,
Bruno Dubois,
Marc Teichmann,
Stéphane Epelbaum,
Olivier Colliot
Abstract:
BACKGROUND:Automated volumetry software (AVS) has recently become widely available to neuroradiologists. MRI volumetry with AVS may support the diagnosis of dementias by identifying regional atrophy. Moreover, automatic classifiers using machine learning techniques have recently emerged as promising approaches to assist diagnosis. However, the performance of both AVS and automatic classifiers has…
▽ More
BACKGROUND:Automated volumetry software (AVS) has recently become widely available to neuroradiologists. MRI volumetry with AVS may support the diagnosis of dementias by identifying regional atrophy. Moreover, automatic classifiers using machine learning techniques have recently emerged as promising approaches to assist diagnosis. However, the performance of both AVS and automatic classifiers has been evaluated mostly in the artificial setting of research datasets.OBJECTIVE:Our aim was to evaluate the performance of two AVS and an automatic classifier in the clinical routine condition of a memory clinic.METHODS:We studied 239 patients with cognitive troubles from a single memory center cohort. Using clinical routine T1-weighted MRI, we evaluated the classification performance of: 1) univariate volumetry using two AVS (volBrain and Neuroreader$^{TM}$); 2) Support Vector Machine (SVM) automatic classifier, using either the AVS volumes (SVM-AVS), or whole gray matter (SVM-WGM); 3) reading by two neuroradiologists. The performance measure was the balanced diagnostic accuracy. The reference standard was consensus diagnosis by three neurologists using clinical, biological (cerebrospinal fluid) and imaging data and following international criteria.RESULTS:Univariate AVS volumetry provided only moderate accuracies (46% to 71% with hippocampal volume). The accuracy improved when using SVM-AVS classifier (52% to 85%), becoming close to that of SVM-WGM (52 to 90%). Visual classification by neuroradiologists ranged between SVM-AVS and SVM-WGM.CONCLUSION:In the routine practice of a memory clinic, the use of volumetric measures provided by AVS yields only moderate accuracy. Automatic classifiers can improve accuracy and could be a useful tool to assist diagnosis.
△ Less
Submitted 19 March, 2020;
originally announced March 2020.
-
Magnetic sensitivity of the Microwave Cryogenic Sapphire Oscillator
Authors:
Vincent Giordano,
Christophe Fluhr,
Benoit Dubois
Abstract:
The Cryogenic Sapphire Oscillator is today recognized for its unprecedented frequency stability, mainly coming from the exceptional physical properties of its resonator made in a high quality sapphire crystal. With these instruments, the fractional frequency measurement resolution, currently of the order of 1e-16, is such that it is possible to detect very small phenomena like residual resonator e…
▽ More
The Cryogenic Sapphire Oscillator is today recognized for its unprecedented frequency stability, mainly coming from the exceptional physical properties of its resonator made in a high quality sapphire crystal. With these instruments, the fractional frequency measurement resolution, currently of the order of 1e-16, is such that it is possible to detect very small phenomena like residual resonator environmental sensitivities. Thus, we highlighted an unexpected magnetic sensitivity of the Cryogenic Sapphire Oscillator (CSO) at low magnetic field. The fractional frequency sensitivity has been preliminary evaluated to 1e-13/Gauss, making this phenomenon a potential cause of frequency stability limitation. In this paper we report the experimental data related to the magnetic sensitivity of the quasi-transverse magnetic Whispering Gallery (WGH) modes excited in sapphire crystals differing from their paramagnetic contaminants concentration. The magnetic behavior of the WGH modes does not follow the expected theory combining the Curie law and the Zeeman effect affecting the Electron Spin Resonance of the paramagnetic ions present in the crystal.
△ Less
Submitted 26 February, 2020;
originally announced February 2020.
-
Modeling stripe formation on growing zebrafish tailfins
Authors:
Alexandria Volkening,
Madeline R Abbott,
Dorothy Catey,
Neil Chandra,
Bethany Dubois,
Francesca Lim,
Bjorn Sandstede
Abstract:
As zebrafish develop, black and gold stripes form across their skin due to the interactions of brightly colored pigment cells. These characteristic patterns emerge on the growing fish body, as well as on the anal and caudal fins. While wild-type stripes form parallel to a horizontal marker on the body, patterns on the tailfin gradually extend distally outward. Interestingly, several mutations lead…
▽ More
As zebrafish develop, black and gold stripes form across their skin due to the interactions of brightly colored pigment cells. These characteristic patterns emerge on the growing fish body, as well as on the anal and caudal fins. While wild-type stripes form parallel to a horizontal marker on the body, patterns on the tailfin gradually extend distally outward. Interestingly, several mutations lead to altered body patterns without affecting fin stripes. Through an exploratory modeling approach, our goal is to help better understand these differences between body and fin patterns. By adapting a prior agent-based model of cell interactions on the fish body, we present an in silico study of stripe development on tailfins. Our main result is a demonstration that two cell types can produce stripes on the caudal fin. We highlight several ways that bone rays, growth, and the body-fin interface may be involved in patterning, and we raise questions for future work related to pattern robustness.
△ Less
Submitted 9 November, 2019;
originally announced November 2019.
-
The influence of diversity on the measurement of functional impairment: An international validation of the Amsterdam IADL Questionnaire in 8 countries
Authors:
Mark A. Dubbelman,
Merike Verrijp,
David Facal,
Gonzalo Sánchez-Benavides,
Laura J. E. Brown,
Wiesje M. van der Flier,
Hanna Jokinen,
Athene Lee,
Iracema Leroi,
Cristina Lojo-Seoane,
Vuk Milosevic,
José Luís Molinuevo,
Arturo X. Pereiro Rozas,
Craig Ritchie,
Stephen Salloway,
Gemma Stringer,
Stelios Zygouris,
Bruno Dubois,
Stéphane Epelbaum,
Philip Scheltens,
Sietske A. M. Sikkes
Abstract:
INTRODUCTION: To understand the potential influence of diversity on the measurement of functional impairment in dementia, we aimed to investigate possible bias caused by age, gender, education, and cultural differences. METHODS: 3,571 individuals (67.1 {\pm} 9.5 years old, 44.7% female) from the Netherlands, Spain, France, United States, United Kingdom, Greece, Serbia and Finland were included. Fu…
▽ More
INTRODUCTION: To understand the potential influence of diversity on the measurement of functional impairment in dementia, we aimed to investigate possible bias caused by age, gender, education, and cultural differences. METHODS: 3,571 individuals (67.1 {\pm} 9.5 years old, 44.7% female) from the Netherlands, Spain, France, United States, United Kingdom, Greece, Serbia and Finland were included. Functional impairment was measured using the Amsterdam IADL Questionnaire. Item bias was assessed using differential item functioning (DIF) analysis. RESULTS: There were some differences in activity endorsement. A few items showed statistically significant DIF. However, there was no evidence of meaningful item bias: effect sizes were low (ΔR2 range 0-0.03). Impact on total scores was minimal. DISCUSSION: The results imply a limited bias for age, gender, education and culture in the measurement of functional impairment. This study provides an important step in recognizing the potential influence of diversity on primary outcomes in dementia research.
△ Less
Submitted 29 January, 2020; v1 submitted 4 September, 2019;
originally announced September 2019.
-
KLTS: A rigorous method to compute the confidence intervals for the Three-Cornered Hat and for Groslambert Covariance
Authors:
Éric Lantz,
Claudio E. Calosso,
Enrico Rubiola,
Vincent Giordano,
Christophe Fluhr,
Benoît Dubois,
François Vernotte
Abstract:
The three-cornered hat / Groslambert Covariance methods are widely used to estimate the stability of each individual clock in a set of three, but no method gives reliable confidence intervals for large integration times.
We propose a new KLTS (Karhunen-Loève Tansform using Sufficient statistics) method which uses these estimators to take into account the statistics of all the measurements betwee…
▽ More
The three-cornered hat / Groslambert Covariance methods are widely used to estimate the stability of each individual clock in a set of three, but no method gives reliable confidence intervals for large integration times.
We propose a new KLTS (Karhunen-Loève Tansform using Sufficient statistics) method which uses these estimators to take into account the statistics of all the measurements between the pairs of clocks in a Bayesian way. The resulting Cumulative Density Function (CDF) yields confidence intervals for each clock AVAR. This CDF provides also a stability estimator which is always positive.
Checked by massive Monte-Carlo simulations, KLTS proves to be perfectly reliable even for one degree of freedom. An example of experimental measurement is given.
△ Less
Submitted 1 August, 2019; v1 submitted 11 April, 2019;
originally announced April 2019.
-
Neural correlates of episodic memory in the Memento cohort
Authors:
Stéphane Epelbaum,
Vincent Bouteloup,
Jean Mangin,
Valentina La Corte,
Raffaela Migliaccio,
Hugo Bertin,
Marie O. Habert,
Clara Fischer,
Chabha Azouani,
Ludovic Fillon,
Marie Chupin,
Bruno Vellas,
Florence Pasquier,
Jean Dartigues,
Frédéric Blanc,
Audrey Gabelle,
Mathieu Ceccaldi,
Pierre Krolak-Salmon,
Jacques Hugon,
Olivier Hanon,
Olivier Rouaud,
Renaud David,
Geneviève Chêne,
Bruno Dubois,
Carole Dufouil
Abstract:
IntroductionThe free and cued selective reminding test is used to identify memory deficits in mild cognitive impairment and demented patients. It allows assessing three processes: encoding, storage, and recollection of verbal episodic memory.MethodsWe investigated the neural correlates of these three memory processes in a large cohort study. The Memento cohort enrolled 2323 outpatients presenting…
▽ More
IntroductionThe free and cued selective reminding test is used to identify memory deficits in mild cognitive impairment and demented patients. It allows assessing three processes: encoding, storage, and recollection of verbal episodic memory.MethodsWe investigated the neural correlates of these three memory processes in a large cohort study. The Memento cohort enrolled 2323 outpatients presenting either with subjective cognitive decline or mild cognitive impairment who underwent cognitive, structural MRI and, for a subset, fluorodeoxyglucose--positron emission tomography evaluations.ResultsEncoding was associated with a network including parietal and temporal cortices; storage was mainly associated with entorhinal and parahippocampal regions, bilaterally; retrieval was associated with a widespread network encompassing frontal regions.DiscussionThe neural correlates of episodic memory processes can be assessed in large and standardized cohorts of patients at risk for Alzheimer's disease. Their relation to pathophysiological markers of Alzheimer's disease remains to be studied.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
COGEVIS: A New Scale to Evaluate Cognition in Patients with Visual Deficiency
Authors:
Claire Meyniel,
Dalila Samri,
Farah Stefano,
Joel Crevoisier,
Florence Bonté,
Raffaella Migliaccio,
Laure Delaby,
Anne Bertrand,
Marie Odile Habert,
Bruno Dubois,
Bahram Bodaghi,
Stéphane Epelbaum
Abstract:
We evaluated the cognitive status of visually impaired patients referred to low vision rehabilitation (LVR) based on a standard cognitive battery and a new evaluation tool, named the COGEVIS, which can be used to assess patients with severe visual deficits. We studied patients aged 60 and above, referred to the LVR Hospital in Paris. Neurological and cognitive evaluations were performed in an expe…
▽ More
We evaluated the cognitive status of visually impaired patients referred to low vision rehabilitation (LVR) based on a standard cognitive battery and a new evaluation tool, named the COGEVIS, which can be used to assess patients with severe visual deficits. We studied patients aged 60 and above, referred to the LVR Hospital in Paris. Neurological and cognitive evaluations were performed in an expert memory center. Thirty-eight individuals, 17 women and 21 men with a mean age of 70.3 $\pm$ 1.3 years and a mean visual acuity of 0.12 $\pm$ 0.02, were recruited over a one-year period. Sixty-three percent of participants had normal cognitive status. Cognitive impairment was diagnosed in 37.5% of participants. The COGEVIS score cutoff point to screen for cognitive impairment was 24 (maximum score of 30) with a sensitivity of 66.7% and a specificity of 95%. Evaluation following 4 months of visual rehabilitation showed an improvement of Instrumental Activities of Daily Living (p = 0 004), National Eye Institute Visual Functioning Questionnaire (p = 0 035), and Montgomery-Åsberg Depression Rating Scale (p = 0 037). This study introduces a new short test to screen for cognitive impairment in visually impaired patients.
△ Less
Submitted 18 December, 2018;
originally announced December 2018.
-
Disrupted core-periphery structure of multimodal brain networks in Alzheimer's Disease
Authors:
Jeremy Guillon,
Mario Chavez,
Federico Battiston,
Yohan Attal,
Valentina La Corte,
Michel Thiebaut de Schotten,
Bruno Dubois,
Denis Schwartz,
Olivier Colliot,
Fabrizio De Vico Fallani
Abstract:
In Alzheimer's disease (AD), the progressive atrophy leads to aberrant network reconfigurations both at structural and functional levels. In such network reorganization, the core and peripheral nodes appear to be crucial for the prediction of clinical outcome due to their ability to influence large-scale functional integration. However, the role of the different types of brain connectivity in such…
▽ More
In Alzheimer's disease (AD), the progressive atrophy leads to aberrant network reconfigurations both at structural and functional levels. In such network reorganization, the core and peripheral nodes appear to be crucial for the prediction of clinical outcome due to their ability to influence large-scale functional integration. However, the role of the different types of brain connectivity in such prediction still remains unclear. Using a multiplex network approach we integrated information from DWI, fMRI and MEG brain connectivity to extract an enriched description of the core-periphery structure in a group of AD patients and age-matched controls. Globally, the regional coreness - i.e., the probability of a region to be in the multiplex core - significantly decreased in AD patients as a result of the randomization process initiated by the neurodegeneration. Locally, the most impacted areas were in the core of the network - including temporal, parietal and occipital areas - while we reported compensatory increments for the peripheral regions in the sensorimotor system. Furthermore, these network changes significantly predicted the cognitive and memory impairment of patients. Taken together these results indicate that a more accurate description of neurodegenerative diseases can be obtained from the multimodal integration of neuroimaging-derived network data.
△ Less
Submitted 7 December, 2018; v1 submitted 28 November, 2018;
originally announced November 2018.
-
Frequency Stability Measurement of Cryogenic Sapphire Oscillators with a Multichannel Tracking DDS and the Two-Sample Covariance
Authors:
Claudio E. Calosso,
François Vernotte,
Vincent Giordano,
Christophe Fluhr Benoît Dubois,
Enrico Rubiolar
Abstract:
This article shows the first measurement of three 100 MHz signals exhibiting fluctuations from 2E-16 to parts in 1E-15 for integration time tau between 1 s and 1 day. Such stable signals are provided by three Cryogenic Sapphire Oscillators (CSOs) operating at about 10 GHz, also delivering the 100 MHz output via a dedicated synthesizer. The measurement is made possible by a 6-channel Tracking DDS (…
▽ More
This article shows the first measurement of three 100 MHz signals exhibiting fluctuations from 2E-16 to parts in 1E-15 for integration time tau between 1 s and 1 day. Such stable signals are provided by three Cryogenic Sapphire Oscillators (CSOs) operating at about 10 GHz, also delivering the 100 MHz output via a dedicated synthesizer. The measurement is made possible by a 6-channel Tracking DDS (TDDS) and the two-sample covariance tool, used to estimate the Allan variance. The use of two TDDS channels per CSO enables high rejection of the instrument background noise. The covariance outperforms the Three-Cornered Hat (TCH) method in that the background converges to zero "out of the box," with no need of the hypothesis that the instrument channels are equally noisy, nor of more sophisticated techniques to estimate the background noise of each channel. Thanks to correlation and averaging, the instrument background (AVAR) rolls off with a slope 1/sqrt(m), the number of measurements, down to 1E-18 tau = 1E4 s. For consistency check, we compare the results to the traditional TCH method beating the 10 GHz outputs down to the MHz region. Given the flexibility of the TDDS, our methods find immediate application to the measurement of the 250 MHz output of the FS combs.
△ Less
Submitted 29 August, 2018;
originally announced August 2018.
-
Photonic Generation of High Power, Ultrastable Microwave Signals by Vernier Effect in a Femtosecond Laser Frequency Comb
Authors:
Khaldoun Saleh,
Jacques Millo,
Baptiste Marechal,
Benoît Dubois,
Ahmed Bakir,
Alexandre Didier,
Clément Lacroûte,
Yann Kersalé
Abstract:
Optical frequency division of an ultrastable laser to the microwave frequency range by an optical frequency comb has allowed the generation of microwave signals with unprecedently high spectral purity and stability. However, the generated microwave signal will suffer from a very low power level if no external optical frequency comb repetition rate multiplication device is used. This paper reports…
▽ More
Optical frequency division of an ultrastable laser to the microwave frequency range by an optical frequency comb has allowed the generation of microwave signals with unprecedently high spectral purity and stability. However, the generated microwave signal will suffer from a very low power level if no external optical frequency comb repetition rate multiplication device is used. This paper reports theoretical and experimental studies on the beneficial use of the Vernier effect together with the spectral selective filtering in a double directional coupler add-drop optical fibre ring resonator to increase the comb repetition rate and generate high power microwaves. The studies are focused on two selective filtering aspects: the high rejection of undesirable optical modes of the frequency comb and the transmission of the desirable modes with the lowest possible loss. Moreover, the conservation of the frequency comb stability and linewidth at the resonator output is particularly considered. Accordingly, a fibre ring resonator is designed, fabricated, and characterized, and a technique to stabilize the resonator's resonance comb is proposed. A significant power gain is achieved for the photonically generated beat note at 10 GHz. Routes to highly improve the performances of such proof-of-concept device are also discussed.
△ Less
Submitted 1 February, 2018;
originally announced February 2018.
-
Multidimensional classification of hippocampal shape features discriminates Alzheimer's disease and mild cognitive impairment from normal aging
Authors:
Emilie Gerardin,
Gaël Chételat,
Marie Chupin,
Rémi Cuingnet,
Béatrice Desgranges,
Ho-Sung Kim,
Marc Niethammer,
Bruno Dubois,
Stéphane Lehéricy,
Line Garnero,
Francis Eustache,
Olivier Colliot
Abstract:
We describe a new method to automatically discriminate between patients with Alzheimer's disease (AD) or mild cognitive impairment (MCI) and elderly controls, based on multidimensional classification of hippocampal shape features. This approach uses spherical harmonics (SPHARM) coefficients to model the shape of the hippocampi, which are segmented from magnetic resonance images (MRI) using a fully…
▽ More
We describe a new method to automatically discriminate between patients with Alzheimer's disease (AD) or mild cognitive impairment (MCI) and elderly controls, based on multidimensional classification of hippocampal shape features. This approach uses spherical harmonics (SPHARM) coefficients to model the shape of the hippocampi, which are segmented from magnetic resonance images (MRI) using a fully automatic method that we previously developed. SPHARM coefficients are used as features in a classification procedure based on support vector machines (SVM). The most relevant features for classification are selected using a bagging strategy. We evaluate the accuracy of our method in a group of 23 patients with AD (10 males, 13 females, age $\pm$ standard-deviation (SD) = 73 $\pm$ 6 years, mini-mental score (MMS) = 24.4 $\pm$ 2.8), 23 patients with amnestic MCI (10 males, 13 females, age $\pm$ SD = 74 $\pm$ 8 years, MMS = 27.3 $\pm$ 1.4) and 25 elderly healthy controls (13 males, 12 females, age $\pm$ SD = 64 $\pm$ 8 years), using leave-one-out cross-validation. For AD vs controls, we obtain a correct classification rate of 94%, a sensitivity of 96%, and a specificity of 92%. For MCI vs controls, we obtain a classification rate of 83%, a sensitivity of 83%, and a specificity of 84%. This accuracy is superior to that of hippocampal volumetry and is comparable to recently published SVM-based whole-brain classification methods, which relied on a different strategy. This new method may become a useful tool to assist in the diagnosis of Alzheimer's disease.
△ Less
Submitted 19 July, 2017;
originally announced July 2017.
-
Loss of brain inter-frequency hubs in Alzheimer's disease
Authors:
Jeremy Guillon,
Yohan Attal,
Olivier Colliot,
Valentina La Corte,
Bruno Dubois,
Denis Schwartz,
Mario Chavez,
Fabrizio De Vico Fallani
Abstract:
Alzheimer's disease (AD) causes alterations of brain network structure and function. The latter consists of connectivity changes between oscillatory processes at different frequency channels. We proposed a multi-layer network approach to analyze multiple-frequency brain networks inferred from magnetoencephalographic recordings during resting-states in AD subjects and age-matched controls. Main res…
▽ More
Alzheimer's disease (AD) causes alterations of brain network structure and function. The latter consists of connectivity changes between oscillatory processes at different frequency channels. We proposed a multi-layer network approach to analyze multiple-frequency brain networks inferred from magnetoencephalographic recordings during resting-states in AD subjects and age-matched controls. Main results showed that brain networks tend to facilitate information propagation across different frequencies, as measured by the multi-participation coefficient (MPC). However, regional connectivity in AD subjects was abnormally distributed across frequency bands as compared to controls, causing significant decreases of MPC. This effect was mainly localized in association areas and in the cingulate cortex, which acted, in the healthy group, as a true inter-frequency hub. MPC values significantly correlated with memory impairment of AD subjects, as measured by the total recall score. Most predictive regions belonged to components of the default-mode network that are typically affected by atrophy, metabolism disruption and amyloid-beta deposition. We evaluated the diagnostic power of the MPC and we showed that it led to increased classification accuracy (78.39%) and sensitivity (91.11%). These findings shed new light on the brain functional alterations underlying AD and provide analytical tools for identifying multi-frequency neural mechanisms of brain diseases.
△ Less
Submitted 10 March, 2017; v1 submitted 31 December, 2016;
originally announced January 2017.
-
Characterization of Zero-Bias Microwave Diode Power Detectors at Cryogenic Temperature
Authors:
Vincent Giordano,
Christophe Fluhr,
Benoît Dubois,
Enrico Rubiola
Abstract:
We present the characterization of commercial tunnel diode low-level microwave power detectors at room and cryogenic temperatures. The sensitivity as well as the output voltage noise of the tunnel diodes are measured as functions of the applied microwave power, the signal frequency being 10 GHz. We highlight strong variations of the diode characteristics when the applied microwave power is higher…
▽ More
We present the characterization of commercial tunnel diode low-level microwave power detectors at room and cryogenic temperatures. The sensitivity as well as the output voltage noise of the tunnel diodes are measured as functions of the applied microwave power, the signal frequency being 10 GHz. We highlight strong variations of the diode characteristics when the applied microwave power is higher than few microwatt. For a diode operating at ${4}$ K, the differential gain increases from ${1,000}$ V/W to about ${4,500}$ V/W when the power passes from ${-30}$ dBm to ${-20}$ dBm. The diode present a white noise floor equivalent to a NEP of ${0.8}$ pW/ ${\sqrt{\mathrm{Hz}}}$ and ${8}$ pW/${ \sqrt{\mathrm{Hz}}}$ at 4 K and 300 K respectively. Its flicker noise is equivalent to a relative amplitude noise power spectral density ${S_α(1~\mathrm{Hz})=-120}$~dB/Hz at ${4}$ K. Flicker noise is 10 dB higher at room temperature.
△ Less
Submitted 26 January, 2016;
originally announced January 2016.
-
Characterization of the individual short-term frequency stability of Cryogenic Sapphire Oscillators at the 1e-16 level
Authors:
Christophe Fluhr,
Serge Grop,
Benoît Dubois,
Yann Kersalé,
Enrico Rubiola,
Vincent Giordano
Abstract:
We present the characterisation of three Cryogenic Sapphire Oscillators using the three-corner-hat method. Easily implemented with commercial components and instruments, this method reveals itself very useful to analyse the frequency stability limitations of these state-of-the-art ultra-stable oscillators. The best unit presents a fractional frequency stability better than 5e-16 at 1 s and below 2…
▽ More
We present the characterisation of three Cryogenic Sapphire Oscillators using the three-corner-hat method. Easily implemented with commercial components and instruments, this method reveals itself very useful to analyse the frequency stability limitations of these state-of-the-art ultra-stable oscillators. The best unit presents a fractional frequency stability better than 5e-16 at 1 s and below 2e-16 for integration times less than 5,000s.
△ Less
Submitted 10 December, 2015;
originally announced December 2015.
-
Tests of Sapphire Crystals Produced with Different Growth Processes for Ultra-stable Microwave Oscillators
Authors:
Vincent Giordano,
Christophe Fluhr,
Serge Grop,
Benoit Dubois
Abstract:
We present the characterization of 8-12 GHz whispering gallery mode resonators machined in high-quality sapphire crystals elaborated with different growth techniques. These microwave resonators are intended to constitute the reference frequency of ultra-stable Cryogenic Sapphire Oscillators. We conducted systematic tests near 4 K on these crystals to determine the unloaded Q-factor and the turnove…
▽ More
We present the characterization of 8-12 GHz whispering gallery mode resonators machined in high-quality sapphire crystals elaborated with different growth techniques. These microwave resonators are intended to constitute the reference frequency of ultra-stable Cryogenic Sapphire Oscillators. We conducted systematic tests near 4 K on these crystals to determine the unloaded Q-factor and the turnover temperature for whispering gallery modes in the 8-12 GHz frequency range. These characterizations show that high quality sapphire crystals elaborated with the Heat Exchange or the Kyropoulos growth technique are both suitable to meet a fractional frequency stability better than 1x10-15 for 1 s to 10.000 s integration times.
△ Less
Submitted 10 April, 2015;
originally announced April 2015.
-
Ultra-low phase noise all-optical microwave generation setup based on commercial devices
Authors:
A. Didier,
J. Millo,
S. Grop,
B. Dubois,
E. Bigler,
E. Rubiola,
C. Lacroûte,
Y. Kersalé
Abstract:
In this paper, we present a very simple design based on commercial devices for the all-optical generation of ultra-low phase noise microwave signals. A commercial, fibered femtosecond laser is locked to a laser that is stabilized to a commercial ULE Fabry-Perot cavity. The 10 GHz microwave signal extracted from the femtosecond laser output exhibits a single sideband phase noise…
▽ More
In this paper, we present a very simple design based on commercial devices for the all-optical generation of ultra-low phase noise microwave signals. A commercial, fibered femtosecond laser is locked to a laser that is stabilized to a commercial ULE Fabry-Perot cavity. The 10 GHz microwave signal extracted from the femtosecond laser output exhibits a single sideband phase noise $\mathcal{L}(f)=-104 \ \mathrm{dBc}/\mathrm{Hz}$ at 1 Hz Fourier frequency, at the level of the best value obtained with such "microwave photonics" laboratory experiments \cite{Fortier2011}. Close-to-the-carrier ultra-low phase noise microwave signals will now be available in laboratories outside the frequency metrology field, opening up new possibilities in various domains.
△ Less
Submitted 20 March, 2015;
originally announced March 2015.
-
SPIRou: the near-infrared spectropolarimeter/high-precision velocimeter for the Canada-France-Hawaii telescope
Authors:
Étienne Artigau,
Driss Kouach,
Jean-François Donati,
René Doyon,
Xavier Delfosse,
Sébastien Baratchart,
Marielle Lacombe,
Claire Moutou,
Patrick Rabou,
Laurent P. Parès,
Yoan Micheau,
Simon Thibault,
Vladimir A. Reshetov,
Bruno Dubois,
Olivier Hernandez,
Philippe Vallée,
Shiang-Yu Wang,
François Dolon,
Francesco A. Pepe,
François Bouchy,
Nicolas Striebig,
François Hénault,
David Loop,
Leslie Saddlemyer,
Gregory Barrick
, et al. (8 additional authors not shown)
Abstract:
SPIRou is a near-IR échelle spectropolarimeter and high-precision velocimeter under construction as a next-generation instrument for the Canada-France-Hawaii-Telescope. It is designed to cover a very wide simultaneous near-IR spectral range (0.98-2.35 μm) at a resolving power of 73.5K, providing unpolarized and polarized spectra of low-mass stars at a radial velocity (RV) precision of 1m/s. The ma…
▽ More
SPIRou is a near-IR échelle spectropolarimeter and high-precision velocimeter under construction as a next-generation instrument for the Canada-France-Hawaii-Telescope. It is designed to cover a very wide simultaneous near-IR spectral range (0.98-2.35 μm) at a resolving power of 73.5K, providing unpolarized and polarized spectra of low-mass stars at a radial velocity (RV) precision of 1m/s. The main science goals of SPIRou are the detection of habitable super-Earths around low-mass stars and the study of how critically magnetic fields impact star / planet formation. Following a successful final design review in Spring 2014, SPIRou is now under construction and is scheduled to see first light in late 2017. We present an overview of key aspects of SPIRou's optical and mechanical design.
△ Less
Submitted 26 June, 2014;
originally announced June 2014.