-
Roadmap on spatiotemporal light fields
Authors:
Yijie Shen,
Qiwen Zhan,
Logan G. Wright,
Demetrios N. Christodoulides,
Frank W. Wise,
Alan E. Willner,
Zhe Zhao,
Kai-heng Zou,
Chen-Ting Liao,
Carlos Hernández-García,
Margaret Murnane,
Miguel A. Porras,
Andy Chong,
Chenhao Wan,
Konstantin Y. Bliokh,
Murat Yessenov,
Ayman F. Abouraddy,
Liang Jie Wong,
Michael Go,
Suraj Kumar,
Cheng Guo,
Shanhui Fan,
Nikitas Papasimakis,
Nikolay I. Zheludev,
Lu Chen
, et al. (20 additional authors not shown)
Abstract:
Spatiotemporal sculpturing of light pulse with ultimately sophisticated structures represents the holy grail of the human everlasting pursue of ultrafast information transmission and processing as well as ultra-intense energy concentration and extraction. It also holds the key to unlock new extraordinary fundamental physical effects. Traditionally, spatiotemporal light pulses are always treated as…
▽ More
Spatiotemporal sculpturing of light pulse with ultimately sophisticated structures represents the holy grail of the human everlasting pursue of ultrafast information transmission and processing as well as ultra-intense energy concentration and extraction. It also holds the key to unlock new extraordinary fundamental physical effects. Traditionally, spatiotemporal light pulses are always treated as spatiotemporally separable wave packet as solution of the Maxwell's equations. In the past decade, however, more generalized forms of spatiotemporally nonseparable solution started to emerge with growing importance for their striking physical effects. This roadmap intends to highlight the recent advances in the creation and control of increasingly complex spatiotemporally sculptured pulses, from spatiotemporally separable to complex nonseparable states, with diverse geometric and topological structures, presenting a bird's eye viewpoint on the zoology of spatiotemporal light fields and the outlook of future trends and open challenges.
△ Less
Submitted 20 October, 2022;
originally announced October 2022.
-
Laser-Plasma Interactions Enabled by Emerging Technologies
Authors:
J. P. Palastro,
F. Albert,
B. Albright,
T. M. Antonsen Jr.,
A. Arefiev,
J. Bates,
R. Berger,
J. Bromage,
M. Campbell,
T. Chapman,
E. Chowdhury,
A. Colaïtis,
C. Dorrer,
E. Esarey,
F. Fiúza,
N. Fisch,
R. Follett,
D. Froula,
S. Glenzer,
D. Gordon,
D. Haberberger,
B. M. Hegelich,
T. Jones,
D. Kaganovich,
K. Krushelnick
, et al. (29 additional authors not shown)
Abstract:
An overview from the past and an outlook for the future of fundamental laser-plasma interactions research enabled by emerging laser systems.
An overview from the past and an outlook for the future of fundamental laser-plasma interactions research enabled by emerging laser systems.
△ Less
Submitted 30 April, 2019;
originally announced April 2019.
-
Band-Limited Coronagraphs using a halftone-dot process: II. Advances and laboratory results for arbitrary telescope apertures
Authors:
P. Martinez,
C. Dorrer,
M. Kasper
Abstract:
The band-limited coronagraph is a nearly ideal concept that theoretically enables perfect cancellation of all the light of an on-axis source. Over the past years, several prototypes have been developed and tested in the laboratory, and more emphasis is now on develo** optimal technologies that can efficiently deliver the expected high-contrast levels of such a concept.
Following the developmen…
▽ More
The band-limited coronagraph is a nearly ideal concept that theoretically enables perfect cancellation of all the light of an on-axis source. Over the past years, several prototypes have been developed and tested in the laboratory, and more emphasis is now on develo** optimal technologies that can efficiently deliver the expected high-contrast levels of such a concept.
Following the development of an early near-IR demonstrator, we present and discuss the results of a second-generation prototype using halftone-dot technology. We report improvement in the accuracy of the control of the local transmission of the manufactured prototype, which was measured to be less than 1%.
This advanced H-band band-limited device demonstrated excellent contrast levels in the laboratory, down to 10-6 at farther angular separations than 3 lambda/D over 24% spectral bandwidth. These performances outperform the ones of our former prototype by more than an order of magnitude and confirm the maturity of the manufacturing process.
Current and next generation high-contrast instruments can directly benefit from such capabilities. In this context, we experimentally examine the ability of the band-limited coronagraph to withstand various complex telescope apertures.
△ Less
Submitted 29 November, 2011;
originally announced November 2011.
-
Laboratory comparison of coronagraphic concepts under dynamical seeing and high-order adaptive optics correction
Authors:
P. Martinez,
E. Aller-Carpentier,
M. Kasper,
A. Boccaletti,
C. Dorrer,
J. Baudrand
Abstract:
The exoplanetary science through direct imaging and spectroscopy will largely expand with the forthcoming development of new instruments at the VLT (SPHERE), Gemini (GPI), Subaru (HiCIAO), and Palomar (Project 1640) observatories. All these ground-based adaptive optics instruments combine extremely high performance adaptive optics (XAO) systems correcting for the atmospheric turbulence with advanc…
▽ More
The exoplanetary science through direct imaging and spectroscopy will largely expand with the forthcoming development of new instruments at the VLT (SPHERE), Gemini (GPI), Subaru (HiCIAO), and Palomar (Project 1640) observatories. All these ground-based adaptive optics instruments combine extremely high performance adaptive optics (XAO) systems correcting for the atmospheric turbulence with advanced starlight-cancellation techniques such as coronagraphy to deliver contrast ratios of about 10-6 to 10-7. While the past fifteen years have seen intensive research and the development of high-contrast coronagraph concepts, very few concepts have been tested under dynamical seeing conditions (either during sky observation or in a realistic laboratory environment). In this paper, we discuss the results obtained with four different coronagraphs -- phase and amplitude types -- on the High-Order Testbench (HOT), the adaptive optics facility developed at ESO. This facility emphasizes realistic conditions encountered at a telescope (e.g., VLT), including a turbulence generator and a high-order adaptive optics system. It enables to evaluate the performance of high-contrast coronagraphs in the near-IR operating with an AO-corrected PSF of 90% Strehl ratio under 0.5 arcsec dynamical seeing.
△ Less
Submitted 15 February, 2011;
originally announced February 2011.
-
Band-Limited Coronagraphs using a Halftone-dot process: design guidelines, manufacturing, and laboratory results
Authors:
P. Martinez,
C. Dorrer,
M. Kasper
Abstract:
The Exo-Planet Imaging Camera and Spectrograph (EPICS) for the future 42-meter European-Extremely Large Telescope, will enable direct images, and spectra for both young and old Jupiter-mass planets in the infrared. To achieve the required contrast, several coronagraphic concepts -- to remove starlight -- are under investigation: conventional pupil apodization (CPA), apodized-pupil Lyot coronagra…
▽ More
The Exo-Planet Imaging Camera and Spectrograph (EPICS) for the future 42-meter European-Extremely Large Telescope, will enable direct images, and spectra for both young and old Jupiter-mass planets in the infrared. To achieve the required contrast, several coronagraphic concepts -- to remove starlight -- are under investigation: conventional pupil apodization (CPA), apodized-pupil Lyot coronagraph (APLC), dual-zone coronagraph (DZC), four-quadrants phase mask (FQPM), multi-stages FQPM, annular groove phase mask (AGPM), high order optical vortex (OVC), and band-limited coronagraph (BLC). Recent experiment demonstrated the interest of an halftone-dot process -- namely microdots technique -- to generate the adequate transmission profile of pupil apodizers for CPA, APLC, and DZC concepts. Here, we examine the use of this technique to produce band-limited focal plane masks, and present guidelines for the design. Additionally, we present the first near-IR laboratory results with BLCs that confirm the microdots approach as a suitable technique for ground-based observations.
△ Less
Submitted 7 October, 2009;
originally announced October 2009.
-
Design, analysis, and testing of a microdot apodizer for the Apodized Pupil Lyot Coronagraph. II. The dot size impact. (Research Note)
Authors:
P. Martinez,
C. Dorrer,
M. Kasper,
A. Boccaletti,
K. Dohlen
Abstract:
The Apodized Pupil Lyot Coronagraph (APLC) is a promising coronagraphic device for direct exoplanets detection on the European-Extremely Large Telescope. We present new near-IR laboratory results using binary apodizers -- the so-called microdots apodizer -- which represent a very attractive and advantageous solution for the APLC.
Microdots apodizers introduce high-frequency noise whose charact…
▽ More
The Apodized Pupil Lyot Coronagraph (APLC) is a promising coronagraphic device for direct exoplanets detection on the European-Extremely Large Telescope. We present new near-IR laboratory results using binary apodizers -- the so-called microdots apodizer -- which represent a very attractive and advantageous solution for the APLC.
Microdots apodizers introduce high-frequency noise whose characteristics depend on the pixel size. The aim of this work is to characterize the impact of the pixel size on the coronagraphic image. Estimation of both the noise intensity and its localization in the field of view is the objective of this study.
Stray-light diffraction introduced by the finite pixel size was measured during experiment. Intensity decreases, and radial distance increases, when the pixel size gets smaller.
The physical properties of these microdots apodizers have been demonstrated in laboratory. The microdots apodizer is a suitable solution for any coronagraph using pupil amplitude apodization if properly designed.
△ Less
Submitted 16 April, 2009;
originally announced April 2009.
-
Design, analysis and test of a microdots apodizer for the Apodized Pupil Lyot Coronagraph
Authors:
P. Martinez,
C. Dorrer,
E. Aller Carpentier,
M. Kasper,
A. Boccaletti,
K. Dohlen,
N. Yaitskova
Abstract:
Coronagraphic techniques are required to detect exoplanets with future Extremely Large Telescopes. One concept, the Apodized Pupil Lyot Coronagraph (APLC), is combining an apodizer in the entrance aperture and a Lyot opaque mask in the focal plane. This paper presents the manufacturing and tests of a microdots apodizer optimized for the near IR.
The intent of this work is to demonstrate the fe…
▽ More
Coronagraphic techniques are required to detect exoplanets with future Extremely Large Telescopes. One concept, the Apodized Pupil Lyot Coronagraph (APLC), is combining an apodizer in the entrance aperture and a Lyot opaque mask in the focal plane. This paper presents the manufacturing and tests of a microdots apodizer optimized for the near IR.
The intent of this work is to demonstrate the feasibility and performance of binary apodizers for the APLC. This study is also relevant for any coronagraph using amplitude pupil apodization.
A binary apodizer has been designed using a halftone dot process, where the binary array of pixels with either 0% or 100% transmission is calculated to fit the required continuous transmission, i.e. local transmission control is obtained by varying the relative density of the opaque and transparent pixels. An error diffusion algorithm was used to optimize the distribution of pixels that best approximates the required field transmission. The prototype was tested with a coronagraphic setup in the near IR.
The transmission profile of the prototype agrees with the theoretical shape within 3% and is achromatic. The observed apodized and coronagraphic images are consistent with theory. However, binary apodizers introduce high frequency noise that is a function of the pixel size. Numerical simulations were used to specify pixel size in order to minimize this effect, and validated by experiment.
This paper demonstrates that binary apodizers are well suited for being used in high contrast imaging coronagraphs. The correct choice of pixel size is important and must be adressed considering the scientific field of view.
△ Less
Submitted 31 October, 2008;
originally announced October 2008.
-
Direct measurement of spatial Wigner function with area-integrated detection
Authors:
Eran Mukamel,
Konrad Banaszek,
Ian A. Walmsley,
Christophe Dorrer
Abstract:
We demonstrate experimentally a novel technique for characterizing transverse spatial coherence using the Wigner distribution function. The presented method is based on measuring interference between a pair of rotated and displaced replicas of the input beam with an area-integrating detector, and it can be superior in regimes when array detectors are not available. We analyze the quantum optical…
▽ More
We demonstrate experimentally a novel technique for characterizing transverse spatial coherence using the Wigner distribution function. The presented method is based on measuring interference between a pair of rotated and displaced replicas of the input beam with an area-integrating detector, and it can be superior in regimes when array detectors are not available. We analyze the quantum optical picture of the presented measurement for single-photon signals and discuss possible applications in quantum information processing.
△ Less
Submitted 17 February, 2003;
originally announced February 2003.