-
Few-electron highly charged muonic Ar atoms verified by electronic $K$ x rays
Authors:
T. Okumura,
T. Azuma,
D. A. Bennett,
W. B. Doriese,
M. S. Durkin,
J. W. Fowler,
J. D. Gard,
T. Hashimoto,
R. Hayakawa,
Y. Ichinohe,
P. Indelicato,
T. Isobe,
S. Kanda,
D. Kato,
M. Katsuragawa,
N. Kawamura,
Y. Kino,
N. Kominato,
Y. Miyake,
K. M. Morgan,
H. Noda,
G. C. O'Neil,
S. Okada,
K. Okutsu,
N. Paul
, et al. (18 additional authors not shown)
Abstract:
Electronic $K$ x rays emitted by muonic Ar atoms in the gas phase were observed using a superconducting transition-edge-sensor microcalorimeter. The high-precision energy spectra provided a clear signature of the presence of muonic atoms accompanied by a few electrons, which have never been observed before. One-, two-, and three-electron bound, i.e., H-like, He-like, and Li-like, muonic Ar atoms w…
▽ More
Electronic $K$ x rays emitted by muonic Ar atoms in the gas phase were observed using a superconducting transition-edge-sensor microcalorimeter. The high-precision energy spectra provided a clear signature of the presence of muonic atoms accompanied by a few electrons, which have never been observed before. One-, two-, and three-electron bound, i.e., H-like, He-like, and Li-like, muonic Ar atoms were identified from electronic $K$ x rays and hyper-satellite $K$ x rays. These $K$ x rays are emitted after the charge transfer process by the collisions with surrounding Ar atoms. With the aid of theoretical calculations, we confirmed that the peak positions are consistent with the x-ray energies from highly charged Cl ions, and the intensities reflecting deexcitation dynamics were successfully understood by taking into account the interaction between the muon and bound electrons.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
System performance of a TDM test-bed with long flex harness towards the new X-IFU FPA-DM
Authors:
D. Vaccaro,
M. de Wit,
J. van der Kuur,
L. Gottardi,
K. Ravensberg,
E. Taralli,
J. Adams,
S. R. Bandler,
J. A. Chervenak,
W. B. Doriese,
M. Durkin,
C. Reintsema,
K. Sakai,
S. J. Smith,
N. A. Wakeham,
B. Jackson,
P. Khosropanah,
J. R. Gao,
J. W. A. den Herder,
P. Roelfsema
Abstract:
SRON (Netherlands Institute for Space Research) is develo** the Focal Plane Assembly (FPA) for Athena X-IFU, whose Demonstration Model (DM) will use for the first time a time domain multiplexing (TDM)-based readout system for the on-board transition-edge sensors (TES). We report on the characterization activities on a TDM setup provided by NASA Goddard Space Flight Center (GSFC) and National Ins…
▽ More
SRON (Netherlands Institute for Space Research) is develo** the Focal Plane Assembly (FPA) for Athena X-IFU, whose Demonstration Model (DM) will use for the first time a time domain multiplexing (TDM)-based readout system for the on-board transition-edge sensors (TES). We report on the characterization activities on a TDM setup provided by NASA Goddard Space Flight Center (GSFC) and National Institute for Standards and Technology (NIST) and tested in SRON cryogenic test facilities. The goal of these activities is to study the impact of the longer harness, closer to X-IFU specs, in a different EMI environment and switching from a single-ended to a differential readout scheme. In this contribution we describe the advancement in the debugging of the system in the SRON cryostat, which led to the demonstration of the nominal spectral performance of 2.8 eV at 5.9~keV with 16-row multiplexing, as well as an outlook for the future endeavours for the TDM readout integration on X-IFU's FPA-DM at SRON.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
End-to-End Modeling of the TDM Readout System for CMB-S4
Authors:
David C. Goldfinger,
Zeeshan Ahmed,
Darcy R. Barron,
W. Bertrand Doriese,
Malcolm Durkin,
Jeffrey P. Filippini,
Gunther Haller,
Shawn W. Henderson,
Ryan Herbst,
Johannes Hubmayr,
Kent Irwin,
Ben Reese,
Leonid Sapozhnikov,
Keith L. Thompson,
Joel Ullom,
Michael R. Vissers
Abstract:
The CMB-S4 experiment is develo** next-generation ground-based microwave telescopes to observe the Cosmic Microwave Background with unprecedented sensitivity. This will require an order of magnitude increase in the 100 mK detector count, which in turn increases the demands on the readout system. The CMB-S4 readout will use time division multiplexing (TDM), taking advantage of faster switches and…
▽ More
The CMB-S4 experiment is develo** next-generation ground-based microwave telescopes to observe the Cosmic Microwave Background with unprecedented sensitivity. This will require an order of magnitude increase in the 100 mK detector count, which in turn increases the demands on the readout system. The CMB-S4 readout will use time division multiplexing (TDM), taking advantage of faster switches and amplifiers in order to achieve an increased multiplexing factor. To facilitate the design of the new readout system, we have developed a model that predicts the bandwidth and noise performance of this circuity and its interconnections. This is then used to set requirements on individual components in order to meet the performance necessary for the full system. We present an overview of this model and compare the model results to the performance of both legacy and prototype readout hardware.
△ Less
Submitted 17 November, 2023; v1 submitted 7 November, 2023;
originally announced November 2023.
-
A tabletop x-ray tomography instrument for nanometer-scale imaging: demonstration of the 1,000-element transition-edge sensor subarray
Authors:
Paul Szypryt,
Nathan Nakamura,
Daniel T. Becker,
Douglas A. Bennett,
Amber L. Dagel,
W. Bertrand Doriese,
Joseph W. Fowler,
Johnathon D. Gard,
J. Zachariah Harris,
Gene C. Hilton,
Jozsef Imrek,
Edward S. Jimenez,
Kurt W. Larson,
Zachary H. Levine,
John A. B. Mates,
D. McArthur,
Luis Miaja-Avila,
Kelsey M. Morgan,
Galen C. O'Neil,
Nathan J. Ortiz,
Christine G. Pappas,
Daniel R. Schmidt,
Kyle R. Thompson,
Joel N. Ullom,
Leila Vale
, et al. (6 additional authors not shown)
Abstract:
We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly efficient and pixelated TES spectrometer to reconstruct three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel prototype spectrometer was recent…
▽ More
We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly efficient and pixelated TES spectrometer to reconstruct three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel prototype spectrometer was recently used to reconstruct ICs at the 130 nm technology node, but to increase imaging speed to more practical levels, the detector efficiency needs to be improved. For this reason, we are building a spectrometer that will eventually contain 3,000 TES microcalorimeters read out with microwave superconducting quantum interference device (SQUID) multiplexing, and we currently have commissioned a 1,000 TES subarray. This still represents a significant improvement from the 240-pixel system and allows us to begin characterizing the full spectrometer performance. Of the 992 maximimum available readout channels, we have yielded 818 devices, representing the largest number of TES x-ray microcalorimeters simultaneously read out to date. These microcalorimeters have been optimized for pulse speed rather than purely energy resolution, and we measure a FWHM energy resolution of 14 eV at the 8.0 keV Cu K$α$ line.
△ Less
Submitted 22 December, 2022;
originally announced December 2022.
-
First Flight Performance of the Micro-X Microcalorimeter X-Ray Sounding Rocket
Authors:
Joseph S. Adams,
Robert Baker,
Simon R. Bandler,
Noemie Bastidon,
Daniel Castro,
Meredith E. Danowksi,
William B. Doriese,
Megan E. Eckart,
Enectali Figueroa-Feliciano,
Joshua Fuhrman,
David C. Goldfinger,
Sarah N. T. Heine,
Gene Hilton,
Antonia J. F. Hubbard,
Daniel Jardin,
Richard L. Kelley,
Caroline A. Kilbourne,
Steven W. Leman,
Renee E. Manzagol-Harwood,
Dan McCammon,
Philip H. H. Oakley,
Takashi Okajima,
Frederick Scott Porter,
Carl D. Reintsema,
John Rutherford
, et al. (6 additional authors not shown)
Abstract:
The flight of the Micro-X sounding rocket on July 22, 2018 marked the first operation of Transition-Edge Sensors and their SQUID readouts in space. The instrument combines the microcalorimeter array with an imaging mirror to take high-resolution spectra from extended X-ray sources. The first flight target was the Cassiopeia~A Supernova Remnant. While a rocket pointing malfunction led to no time on…
▽ More
The flight of the Micro-X sounding rocket on July 22, 2018 marked the first operation of Transition-Edge Sensors and their SQUID readouts in space. The instrument combines the microcalorimeter array with an imaging mirror to take high-resolution spectra from extended X-ray sources. The first flight target was the Cassiopeia~A Supernova Remnant. While a rocket pointing malfunction led to no time on-target, data from the flight was used to evaluate the performance of the instrument and demonstrate the flight viability of the payload. The instrument successfully achieved a stable cryogenic environment, executed all flight operations, and observed X-rays from the on-board calibration source. The flight environment did not significantly affect the performance of the detectors compared to ground operation. The flight provided an invaluable test of the impact of external magnetic fields and the instrument configuration on detector performance. This flight provides a milestone in the flight readiness of these detector and readout technologies, both of which have been selected for future X-ray observatories.
△ Less
Submitted 22 December, 2022;
originally announced December 2022.
-
Nanoscale Three-Dimensional Imaging of Integrated Circuits using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer
Authors:
Nathan Nakamura,
Paul Szypryt,
Amber L. Dagel,
Bradley K. Alpert,
Douglas A. Bennett,
W. Bertrand Doriese,
Malcolm Durkin,
Joseph W. Fowler,
Dylan T. Fox,
Johnathon D. Gard,
Ryan N. Goodner,
J. Zachariah Harris,
Gene C. Hilton,
Edward S. Jimenez,
Burke L. Kernen,
Kurt W. Larson,
Zachary H. Levine,
Daniel McArthur,
Kelsey M. Morgan,
Galen C. O'Neil,
Nathan J. Ortiz,
Christine G. Pappas,
Carl D. Reintsema,
Daniel R. Schmidt,
Peter A. Schultz
, et al. (8 additional authors not shown)
Abstract:
X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but is difficult to implement due to competing requirements on X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial res…
▽ More
X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but is difficult to implement due to competing requirements on X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while changing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot in a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with high signal-to-noise. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enable nanoscale, element-specific X-ray imaging in a compact footprint. The proof-of-concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in 6 layers of a Cu-SiO2 integrated circuit, and a path towards finer resolution and enhanced imaging capabilities is discussed.
△ Less
Submitted 4 March, 2024; v1 submitted 20 December, 2022;
originally announced December 2022.
-
Design of a 3000-pixel transition-edge sensor x-ray spectrometer for microcircuit tomography
Authors:
Paul Szypryt,
Douglas A. Bennett,
William J. Boone,
Amber L. Dagel,
Gabriella Dalton,
W. Bertrand Doriese,
Joseph W. Fowler,
Edward J. Garboczi,
Johnathon D. Gard,
Gene C. Hilton,
Jozsef Imrek,
Edward S. Jimenez,
Vincent Y. Kotsubo,
Kurt Larson,
Zachary H. Levine,
John A. B. Mates,
Daniel McArthur,
Kelsey M. Morgan,
Nathan Nakamura,
Galen C. O'Neil,
Nathan J. Ortiz,
Christine G. Pappas,
Carl D. Reintsema,
Daniel R. Schmidt,
Daniel S. Swetz
, et al. (6 additional authors not shown)
Abstract:
Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approa…
▽ More
Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approach that addresses this imaging problem through x-ray tomography, which we uniquely realize with an instrument that combines a scanning electron microscope (SEM) with a transition-edge sensor (TES) x-ray spectrometer. Our approach uses the highly focused SEM electron beam to generate a small x-ray generation region in a carefully designed target layer that is placed over the sample being tested. With the high collection efficiency and resolving power of a TES spectrometer, we can isolate x-rays generated in the target from background and trace their paths through regions of interest in the sample layers, providing information about the various materials along the x-ray paths through their attenuation functions. We have recently demonstrated our approach using a 240 Mo/Cu bilayer TES prototype instrument on a simplified test sample containing features with sizes of $\sim$1 $μ$m. Currently, we are designing and building a 3000 Mo/Au bilayer TES spectrometer upgrade, which is expected to improve the imaging speed by factor of up to 60 through a combination of increased detector number and detector speed.
△ Less
Submitted 14 December, 2022;
originally announced December 2022.
-
Line Emission Mapper (LEM): Probing the physics of cosmic ecosystems
Authors:
Ralph Kraft,
Maxim Markevitch,
Caroline Kilbourne,
Joseph S. Adams,
Hiroki Akamatsu,
Mohammadreza Ayromlou,
Simon R. Bandler,
Marco Barbera,
Douglas A. Bennett,
Anil Bhardwaj,
Veronica Biffi,
Dennis Bodewits,
Akos Bogdan,
Massimiliano Bonamente,
Stefano Borgani,
Graziella Branduardi-Raymont,
Joel N. Bregman,
Joseph N. Burchett,
Jenna Cann,
Jenny Carter,
Priyanka Chakraborty,
Eugene Churazov,
Robert A. Crain,
Renata Cumbee,
Romeel Dave
, et al. (85 additional authors not shown)
Abstract:
The Line Emission Mapper (LEM) is an X-ray Probe for the 2030s that will answer the outstanding questions of the Universe's structure formation. It will also provide transformative new observing capabilities for every area of astrophysics, and to heliophysics and planetary physics as well. LEM's main goal is a comprehensive look at the physics of galaxy formation, including stellar and black-hole…
▽ More
The Line Emission Mapper (LEM) is an X-ray Probe for the 2030s that will answer the outstanding questions of the Universe's structure formation. It will also provide transformative new observing capabilities for every area of astrophysics, and to heliophysics and planetary physics as well. LEM's main goal is a comprehensive look at the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. These processes are best studied in X-rays, and emission-line map** is the pressing need in this area. LEM will use a large microcalorimeter array/IFU, covering a 30x30' field with 10" angular resolution, to map the soft X-ray line emission from objects that constitute galactic ecosystems. These include supernova remnants, star-forming regions, superbubbles, galactic outflows (such as the Fermi/eROSITA bubbles in the Milky Way and their analogs in other galaxies), the Circumgalactic Medium in the Milky Way and other galaxies, and the Intergalactic Medium at the outskirts and beyond the confines of galaxies and clusters. LEM's 1-2 eV spectral resolution in the 0.2-2 keV band will make it possible to disentangle the faintest emission lines in those objects from the bright Milky Way foreground, providing groundbreaking measurements of the physics of these plasmas, from temperatures, densities, chemical composition to gas dynamics. While LEM's main focus is on galaxy formation, it will provide transformative capability for all classes of astrophysical objects, from the Earth's magnetosphere, planets and comets to the interstellar medium and X-ray binaries in nearby galaxies, AGN, and cooling gas in galaxy clusters. In addition to pointed observations, LEM will perform a shallow all-sky survey that will dramatically expand the discovery space.
△ Less
Submitted 12 April, 2023; v1 submitted 17 November, 2022;
originally announced November 2022.
-
Signal readout for Transition-Edge Sensor X-ray imaging spectrometers
Authors:
H. Akamatsu,
W. B. Doriese,
J. A. B. Mates,
B. D. Jackson
Abstract:
Arrays of low-temperature microcalorimeters provide a promising technology for X-ray astrophysics: the imaging spectrometer. A camera with at least several thousand pixels, each of which has an energy-resolving power ($E/ΔE\urss{FWHM}$) of a few thousand across a broad energy range (200~eV to 10~keV or higher), would be a revolutionary instrument for the study of energetic astrophysical objects an…
▽ More
Arrays of low-temperature microcalorimeters provide a promising technology for X-ray astrophysics: the imaging spectrometer. A camera with at least several thousand pixels, each of which has an energy-resolving power ($E/ΔE\urss{FWHM}$) of a few thousand across a broad energy range (200~eV to 10~keV or higher), would be a revolutionary instrument for the study of energetic astrophysical objects and phenomena. Signal readout is a critical enabling technology. Multiplexed readout, in which signals from multiple pixels are combined into a single amplifier channel, allows a kilo pixel-scale microcalorimeter array to meet the stringent requirements for power consumption, mass, volume, and cooling capacity in orbit. This chapter describes three different multiplexed-readout technologies for transition-edge-sensor microcalorimeters: time-division multiplexing, frequency-domain multiplexing, and microwave-SQUID multiplexing. For each multiplexing technique, we present the basic method, discuss some design considerations and parameters, and show the state of the art. The chapter concludes with a brief discussion of future prospects.
△ Less
Submitted 12 September, 2022;
originally announced September 2022.
-
A 50 mK test bench for demonstration of the readout chain of Athena/X-IFU
Authors:
Florent Castellani,
Sophie Beaumont,
François Pajot,
Gilles Roudil,
Joseph Adams,
Simon Bandler,
James Chervenak,
Christophe Daniel,
Edward V Denison,
W Bertrand Doriese,
Michel Dupieux,
Malcolm Durkin,
Hervé Geoffray,
Gene C Hilton,
David Murat,
Yann Parot,
Philippe Peille,
Damien Prêle,
Laurent Ravera,
Carl D Reintsema,
Kazuhiro Sakai,
Robert W Stevens,
Joel N Ullom,
Leila R Vale,
Nicholas Wakeham
Abstract:
The X-IFU (X-ray Integral Field Unit) onboard the large ESA mission Athena (Advanced Telescope for High ENergy Astrophysics), planned to be launched in the mid 2030s, will be a cryogenic X-ray imaging spectrometer operating at 55 mK. It will provide unprecedented spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) in the 0.2-12 keV energy range thanks to its array of TES (Tra…
▽ More
The X-IFU (X-ray Integral Field Unit) onboard the large ESA mission Athena (Advanced Telescope for High ENergy Astrophysics), planned to be launched in the mid 2030s, will be a cryogenic X-ray imaging spectrometer operating at 55 mK. It will provide unprecedented spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) in the 0.2-12 keV energy range thanks to its array of TES (Transition Edge Sensors) microcalorimeters of more than 2k pixel. The detection chain of the instrument is developed by an international collaboration: the detector array by NASA/GSFC, the cold electronics by NIST, the cold amplifier by VTT, the WFEE (Warm Front-End Electronics) by APC, the DRE (Digital Readout Electronics) by IRAP and a focal plane assembly by SRON. To assess the operation of the complete readout chain of the X-IFU, a 50 mK test bench based on a kilo-pixel array of microcalorimeters from NASA/GSFC has been developed at IRAP in collaboration with CNES. Validation of the test bench has been performed with an intermediate detection chain entirely from NIST and Goddard. Next planned activities include the integration of DRE and WFEE prototypes in order to perform an end-to-end demonstration of a complete X-IFU detection chain.
△ Less
Submitted 9 September, 2022;
originally announced September 2022.
-
The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase
Authors:
Didier Barret,
Vincent Albouys,
Jan-Willem den Herder,
Luigi Piro,
Massimo Cappi,
Juhani Huovelin,
Richard Kelley,
J. Miguel Mas-Hesse,
Stéphane Paltani,
Gregor Rauw,
Agata Rozanska,
Jiri Svoboda,
Joern Wilms,
Noriko Yamasaki,
Marc Audard,
Simon Bandler,
Marco Barbera,
Xavier Barcons,
Enrico Bozzo,
Maria Teresa Ceballos,
Ivan Charles,
Elisa Costantini,
Thomas Dauser,
Anne Decourchelle,
Lionel Duband
, et al. (274 additional authors not shown)
Abstract:
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide sp…
▽ More
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).
△ Less
Submitted 28 November, 2022; v1 submitted 30 August, 2022;
originally announced August 2022.
-
Conceptual Design of the Modular Detector and Readout System for the CMB-S4 survey experiment
Authors:
D. R. Barron,
Z. Ahmed,
J. Aguilar,
A. J. Anderson,
C. F. Baker,
P. S. Barry,
J. A. Beall,
A. N. Bender,
B. A. Benson,
R. W. Besuner,
T. W. Cecil,
C. L. Chang,
S. C. Chapman,
G. E. Chesmore,
G. Derylo,
W. B. Doriese,
S. M. Duff,
T. Elleflot,
J. P. Filippini,
B. Flaugher,
J. G. Gomez,
P. K. Grimes,
R. Gualtieri,
I. Gullett,
G. Haller
, et al. (25 additional authors not shown)
Abstract:
We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background Stage 4 (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60 percent of the sky. The fundamental…
▽ More
We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background Stage 4 (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60 percent of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over a wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4's science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 square meters of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing.
△ Less
Submitted 3 August, 2022;
originally announced August 2022.
-
A test platform for the detection and readout chain for the Athena X-IFU
Authors:
Gabriele Betancourt-Martinez,
François Pajot,
Sophie Beaumont,
Gilles Roudil,
Joseph Adams,
Hiroki Akamatsu,
Simon Bandler,
Bernard Bertrand,
Marcel Bruijn,
Florent Castellani,
Edoardo Cucchetti,
William Doriese,
Michel Dupieux,
Hervé Geoffray,
Luciano Gottardi,
Brian Jackson,
Jan van der Kuur,
Mikko Kiviranta,
Antoine Miniussi,
Phillipe Peille,
Kevin Ravensberg,
Laurent Ravera,
Carl Reintsema,
Kazuhiro Sakai,
Stephen Smith
, et al. (4 additional authors not shown)
Abstract:
We present a test platform for the Athena X-IFU detection chain, which will serve as the first demonstration of the representative end-to-end detection and readout chain for the X-IFU, using prototypes of the future flight electronics and currently available subsystems. This test bench, housed in a commercial two-stage ADR cryostat, includes a focal plane array placed at the 50 mK cold stage of th…
▽ More
We present a test platform for the Athena X-IFU detection chain, which will serve as the first demonstration of the representative end-to-end detection and readout chain for the X-IFU, using prototypes of the future flight electronics and currently available subsystems. This test bench, housed in a commercial two-stage ADR cryostat, includes a focal plane array placed at the 50 mK cold stage of the ADR with a kilopixel array of transition-edge sensor microcalorimeter spectrometers and associated cold readout electronics. Prototype room temperature electronics for the X-IFU provide the readout, and will evolve over time to become more representative of the X-IFU mission baseline. The test bench yields critical feedback on subsystem designs and interfaces, in particular the warm readout electronics, and will provide an in-house detection system for continued testing and development of the warm readout electronics and for the validation of X-ray calibration sources. In this paper, we describe the test bench subsystems and design, characterization of the cryostat, and current status of the project.
△ Less
Submitted 7 July, 2021;
originally announced July 2021.
-
First operation of Transition-Edge Sensors in space with the Micro-X sounding rocket
Authors:
J. S. Adams,
R. Baker,
S. R. Bandler,
N. Bastidon,
M. E. Danowski,
W. B. Doriese,
M. E. Eckart,
E. Figueroa-Feliciano,
J. Fuhrman,
D. C. Goldfinger,
S. N. T. Heine,
G. C. Hilton,
A. J. F. Hubbard,
D. Jardin,
R. L. Kelley,
C. A. Kilbourne,
R. E. Manzagol-Harwood,
D. McCammon,
T. Okajima,
F. S. Porter,
C. D. Reintsema,
P. Serlemitsos,
S. J. Smith,
P. Wikus
Abstract:
With its first flight in 2018, Micro-X became the first program to fly Transition-Edge Sensors and their SQUID readouts in space. The science goal was a high-resolution, spatially resolved X-ray spectrum of the Cassiopeia A Supernova Remnant. While a rocket pointing error led to no time on target, the data was used to demonstrate the flight performance of the instrument. The detectors observed X-r…
▽ More
With its first flight in 2018, Micro-X became the first program to fly Transition-Edge Sensors and their SQUID readouts in space. The science goal was a high-resolution, spatially resolved X-ray spectrum of the Cassiopeia A Supernova Remnant. While a rocket pointing error led to no time on target, the data was used to demonstrate the flight performance of the instrument. The detectors observed X-rays from the on-board calibration source, but a susceptibility to external magnetic fields limited their livetime. Accounting for this, no change was observed in detector response between ground operation and flight operation. This paper provides an overview of the first flight performance and focuses on the upgrades made in preparation for reflight. The largest changes have been upgrading the SQUIDs to mitigate magnetic susceptibility, synchronizing the clocks on the digital electronics to minimize beat frequencies, and replacing the mounts between the cryostat and the rocket skin to improve mechanical integrity. As the first flight performance was consistent with performance on the ground, reaching the instrument goals in the laboratory is considered a strong predictor of future flight performance.
△ Less
Submitted 3 March, 2021;
originally announced March 2021.
-
Absolute energies and emission line shapes of the L x-ray transitions of lanthanide metals
Authors:
Joseph W. Fowler,
Galen C. O'Neil,
Bradley K. Alpert,
Douglas A. Bennett,
Ed V. Denison,
W. B. Doriese,
Gene C. Hilton,
Lawrence T. Hudson,
Young-Il Joe,
Kelsey M. Morgan,
Daniel R. Schmidt,
Daniel S. Swetz,
Csilla I. Szabo,
Joel N. Ullom
Abstract:
We use an array of transition-edge sensors, cryogenic microcalorimeters with 4 eV energy resolution, to measure L x-ray emission-line profiles of four elements of the lanthanide series: praseodymium, neodymium, terbium, and holmium. The spectrometer also surveys numerous x-ray standards in order to establish an absolute-energy calibration traceable to the International System of Units for the ener…
▽ More
We use an array of transition-edge sensors, cryogenic microcalorimeters with 4 eV energy resolution, to measure L x-ray emission-line profiles of four elements of the lanthanide series: praseodymium, neodymium, terbium, and holmium. The spectrometer also surveys numerous x-ray standards in order to establish an absolute-energy calibration traceable to the International System of Units for the energy range 4 keV to 10 keV. The new results include emission line profiles for 97 lines, each expressed as a sum of one or more Voigt functions; improved absolute energy uncertainty on 71 of these lines relative to existing reference data; a median uncertainty on the peak energy of 0.24 eV, four to ten times better than the median of prior work; and 6 lines that lack any measured values in existing reference tables. The 97 lines comprise nearly all of the most intense L lines from these elements under broad-band x-ray excitation. The work improves on previous measurements made with a similar cryogenic spectrometer by the use of sensors with better linearity in the absorbed energy and a gold x-ray absorbing layer that has a Gaussian energy-response function. It also employs a novel sample holder that enables rapid switching between science targets and calibration targets with excellent gain balancing. Most of the results for peak energy values shown here should be considered as replacements for the currently tabulated standard reference values, while the line shapes given here represent a significant expansion of the scope of available reference data.
△ Less
Submitted 30 November, 2020;
originally announced December 2020.
-
A Transition-edge Sensor-based X-ray Spectrometer for the Study of Highly Charged Ions at the National Institute of Standards and Technology Electron Beam Ion Trap
Authors:
P. Szypryt,
G. C. O'Neil,
E. Takacs,
J. N. Tan,
S. W. Buechele,
A. S. Naing,
D. A. Bennett,
W. B. Doriese,
M. Durkin,
J. W. Fowler,
J. D. Gard,
G. C. Hilton,
K. M. Morgan,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
Yu. Ralchenko
Abstract:
We report on the design, commissioning, and initial measurements of a Transition-edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few decades, the NIST EBIT has produced numerous studies of highly charged ions in diverse fields such as atomic physics, plasma spectroscopy, and laboratory astrophysi…
▽ More
We report on the design, commissioning, and initial measurements of a Transition-edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few decades, the NIST EBIT has produced numerous studies of highly charged ions in diverse fields such as atomic physics, plasma spectroscopy, and laboratory astrophysics. The newly commissioned NIST EBIT TES Spectrometer (NETS) improves the measurement capabilities of the EBIT through a combination of high x-ray collection efficiency and resolving power. NETS utilizes 192 individual TES x-ray microcalorimeters (166/192 yield) to improve upon the collection area by a factor of ~30 over the 4-pixel neutron transmutation doped germanium-based microcalorimeter spectrometer previously used at the NIST EBIT. The NETS microcalorimeters are optimized for the x-ray energies from roughly 500 eV to 8,000 eV and achieve an energy resolution of 3.7 eV to 5.0 eV over this range, a more modest (<2X) improvement over the previous microcalorimeters. Beyond this energy range NETS can operate with various trade-offs, the most significant of which are reduced efficiency at lower energies and being limited to a subset of the pixels at higher energies. As an initial demonstration of the capabilities of NETS, we measured transitions in He-like and H-like O, Ne, and Ar as well as Ni-like W. We detail the energy calibration and data analysis techniques used to transform detector counts into x-ray spectra, a process that will be the basis for analyzing future data.
△ Less
Submitted 11 May, 2020;
originally announced May 2020.
-
On low-energy tail distortions in the detector responsefunction of x-ray microcalorimeter spectrometers
Authors:
G. C. O'Neil,
P. Szypryt,
E. Takacs,
J. N. Tan,
S. W. Buechele,
A. S. Naing,
Y. I. Joe,
D. Swetz,
D. R. Schmidt,
W. B. Doriese,
J. D. Gard,
C. D. Reintsema,
J. N. Ullom,
J. S. Villarrubia,
Yu. Ralchenko
Abstract:
We use narrow spectral lines from the x-ray spectra of various highlycharged ions to measure low-energy tail-like deviations from a Gaussian responsefunction in a microcalorimter x-ray spectrometer with Au absorbers at energiesfrom 650 eV to 3320 eV. We review the literature on low energy tails in othermicrocalorimter x-ray spectrometers and present a model that explains all thereviewed tail fract…
▽ More
We use narrow spectral lines from the x-ray spectra of various highlycharged ions to measure low-energy tail-like deviations from a Gaussian responsefunction in a microcalorimter x-ray spectrometer with Au absorbers at energiesfrom 650 eV to 3320 eV. We review the literature on low energy tails in othermicrocalorimter x-ray spectrometers and present a model that explains all thereviewed tail fraction measurements. In this model a low energy tail arises fromthe combination of electron escape and energy trap** associated with Bi x-rayabsorbers.
△ Less
Submitted 11 May, 2020;
originally announced May 2020.
-
Tuning Excited State Electron Transfer in Fe Tetracyano-Polypyridyl Complexes
Authors:
Kristjan Kunnus,
Lin Li,
Charles J. Titus,
Sang Jun Lee,
Marco E. Reinhard,
Sergey Koroidov,
Kasper S. Kjær,
Kiryong Hong,
Kathryn Ledbetter,
William B. Doriese,
Galen C. O'Neil,
Daniel S. Swetz,
Joel N. Ullom,
Dale Li,
Kent Irwin,
Dennis Nordlund,
Amy A. Cordones,
Kelly J. Gaffney
Abstract:
We have investigated photoinduced intramolecular electron transfer dynamics following metal-to-ligand charge-transfer (MLCT) excitation of [Fe(CN)$_4$(2,2'-bipyridine)]$^{2-}$ (1), [Fe(CN)$_4$(2,3-bis(2-pyridyl)pyrazine)]$^{2-}$ (2) and [Fe(CN)$_4$(2,2'-bipyrimidine)]$^{2-}$ (3) complexes in various solvents with static and time-resolved UV-visible absorption spectroscopy and Fe 2p3d resonant inel…
▽ More
We have investigated photoinduced intramolecular electron transfer dynamics following metal-to-ligand charge-transfer (MLCT) excitation of [Fe(CN)$_4$(2,2'-bipyridine)]$^{2-}$ (1), [Fe(CN)$_4$(2,3-bis(2-pyridyl)pyrazine)]$^{2-}$ (2) and [Fe(CN)$_4$(2,2'-bipyrimidine)]$^{2-}$ (3) complexes in various solvents with static and time-resolved UV-visible absorption spectroscopy and Fe 2p3d resonant inelastic X-ray scattering. We observe $^3$MLCT lifetimes from 180 fs to 67 ps over a wide range of MLCT energies in different solvents by utilizing the strong solvatochromism of the complexes. Intramolecular electron transfer lifetimes governing $^3$MLCT relaxation increase monotonically and (super)exponentially as the $^3$MLCT energy is decreased in 1 and 2 by changing the solvent. This behavior can be described with non-adiabatic classical Marcus electron transfer dynamics along the indirect $^3$MLCT->$^3$MC pathway, where the $^3$MC is the lowest energy metal-centered (MC) excited state. In contrast, the $^3$MLCT lifetime in 3 changes non-monotonically and exhibits a maximum. This qualitatively different behaviour results from direct electron transfer from the $^3$MLCT to the electronic ground state (GS). This pathway involves nuclear tunnelling for the high-frequency polypyridyl skeleton mode ($\hbarω$ = 1530 cm$^{-1}$), which is more displaced for 3 than for either 1 or 2, therefore making the direct pathway significantly more efficient in 3. To our knowledge, this is the first observation of an efficient $^3$MLCT->GS relaxation pathway in an Fe polypyridyl complex. Our study suggests that further extending the MLCT state lifetime requires (1) lowering the $^3$MLCT state energy with respect to the $^3$MC state and (2) suppressing the intramolecular distortion of the electron-accepting ligand in the $^3$MLCT excited state to suppress the rate of direct $^3$MLCT->GS electron transfer.
△ Less
Submitted 30 October, 2019;
originally announced October 2019.
-
First Operation of TES Microcalorimeters in Space with the Micro-X Sounding Rocket
Authors:
J. S. Adams,
R. Baker,
S. R. Bandler,
N. Bastidon,
M. E. Danowski,
W. B. Doriese,
M. E. Eckart,
E. Figueroa-Feliciano,
D. C. Goldfinger,
S. N. T. Heine,
G. C. Hilton,
A. J. F. Hubbard,
R. L. Kelley,
C. A. Kilbourne,
R. E. Manzagol-Harwood,
D. McCammon,
T. Okajima,
F. S. Porter,
C. D. Reintsema,
P. Serlemitsos,
S. J. Smith,
J. N. Ullom,
P. Wikus
Abstract:
Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter array to perform high-resolution X-ray spectroscopy. This instrument flew for the first time on July 22nd, 2018 from the White Sands Missile Range, USA. This flight marks the first successful operation of a Transition-Edge Sensor array and its time division multiplexing read-out system in space. This launch was dedicated to…
▽ More
Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter array to perform high-resolution X-ray spectroscopy. This instrument flew for the first time on July 22nd, 2018 from the White Sands Missile Range, USA. This flight marks the first successful operation of a Transition-Edge Sensor array and its time division multiplexing read-out system in space. This launch was dedicated to the observation of the supernova remnant Cassiopeia A. A failure in the attitude control system prevented the rocket from pointing and led to no time on target. The on-board calibration source provided X-rays in flight, and it is used to compare detector performance during pre-flight integration, flight, and after the successful post-flight recovery. This calibration data demonstrates the capabilities of the detector in a space environment as well as its potential for future flights.
△ Less
Submitted 5 January, 2020; v1 submitted 26 August, 2019;
originally announced August 2019.
-
Micro-X Sounding Rocket: Transitioning from First Flight to a Dark Matter Configuration
Authors:
J. S. Adams,
A. J. Anderson,
R. Baker,
S. R. Bandler,
N. Bastidon,
D. Castro,
M. E. Danowski,
W. B. Doriese,
M. E. Eckart,
E. Figueroa-Feliciano,
D. C. Goldfinger,
S. N. T. Heine,
G. C. Hilton,
A. J. F. Hubbard,
R. L. Kelley,
C. A. Kilbourne,
R. E. Manzagol-Harwood,
D. McCammon,
T. Okajima,
F. S. Porter,
C. D. Reintsema,
P. Serlemitsos,
S. J. Smith,
P. Wikus
Abstract:
The Micro-X sounding rocket flew for the first time on July 22, 2018, becoming the first program to fly Transition-Edge Sensors and multiplexing SQUID readout electronics in space. While a rocket pointing failure led to no time on-target, the success of the flight systems was demonstrated. The successful flight operation of the instrument puts the program in a position to modify the payload for in…
▽ More
The Micro-X sounding rocket flew for the first time on July 22, 2018, becoming the first program to fly Transition-Edge Sensors and multiplexing SQUID readout electronics in space. While a rocket pointing failure led to no time on-target, the success of the flight systems was demonstrated. The successful flight operation of the instrument puts the program in a position to modify the payload for indirect galactic dark matter searches. The payload modifications are motivated by the science requirements of this observation. Micro-X can achieve world-leading sensitivity in the keV regime with a single flight. Dark matter sensitivity projections have been updated to include recent observations and the expected sensitivity of Micro-X to these observed fluxes. If a signal is seen (as seen in the X-ray satellites), Micro-X can differentiate an atomic line from a dark matter signature.
△ Less
Submitted 30 January, 2020; v1 submitted 22 August, 2019;
originally announced August 2019.
-
Resonant soft x-ray scattering from stripe-ordered La$_{2-x}$Ba$_x$CuO$_4$ detected by a transition edge sensor array detector
Authors:
Y. I. Joe,
Y. Fang,
S. Lee,
S. X. L. Sun,
G. A. de la Peña,
W. B. Doriese,
K. M. Morgan,
J. W. Fowler,
L. R. Vale,
F. Rodolakis,
J. L. McChesney,
J. N. Ullom,
D. S. Swetz,
P. Abbamonte
Abstract:
Resonant soft x-ray scattering (RSXS) is a leading probe of valence band order in materials best known for detecting charge density wave order in the copper-oxide superconductors. One of the biggest limitations on the RSXS technique is the presence of a severe fluorescence background which, like the RSXS cross section itself, is enhanced under resonant conditions. This background prevents the stud…
▽ More
Resonant soft x-ray scattering (RSXS) is a leading probe of valence band order in materials best known for detecting charge density wave order in the copper-oxide superconductors. One of the biggest limitations on the RSXS technique is the presence of a severe fluorescence background which, like the RSXS cross section itself, is enhanced under resonant conditions. This background prevents the study of weak signals such as diffuse scattering from glassy or fluctuating order that is spread widely over momentum space. Recent advances in superconducting transition edge sensor (TES) detectors have led to major improvements in energy resolution and detection efficiency in the soft x-ray range. Here, we perform a RSXS study of stripe-ordered La$_{2-x}$Ba$_x$CuO$_4$ at the Cu $L_{3/2}$ edge (932.2 eV) using a TES detector with 1.5 eV resolution, to evaluate its utility for mitigating the fluorescence background problem. We find that, for suitable degree of detuning from the resonance, the TES rejects the fluorescence background, leading to a 5 to 10 times improvement in the statistical quality of the data compared to an equivalent, energy-integrated measurement. We conclude that a TES presents a promising approach to reducing background in RSXS studies and may lead to new discoveries in materials exhibiting valence band order that is fluctuating or glassy.
△ Less
Submitted 16 February, 2020; v1 submitted 17 July, 2019;
originally announced July 2019.
-
Mitigating the effects of charged particle strikes on TES arrays for exotic atom X-ray experiments
Authors:
H. Tatsuno,
D. A. Bennett,
W. B. Doriese,
M. Durkin,
J. W. Fowler,
J. D. Gard,
T. Hashimoto,
R. Hayakawa,
T. Hayashi,
G. C. Hilton,
Y. Ichinohe,
H. Noda,
G. C. O'Neil,
S. Okada,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
S. Yamada
Abstract:
Exotic atom experiments place transition-edge-sensor (TES) microcalorimeter arrays in a high-energy charged particle rich environment. When a high-energy charged particle passes through the silicon substrate of a TES array, a large amount of energy is deposited and small pulses are generated across multiple pixels in the TES array due to thermal crosstalk. We have developed analysis techniques to…
▽ More
Exotic atom experiments place transition-edge-sensor (TES) microcalorimeter arrays in a high-energy charged particle rich environment. When a high-energy charged particle passes through the silicon substrate of a TES array, a large amount of energy is deposited and small pulses are generated across multiple pixels in the TES array due to thermal crosstalk. We have developed analysis techniques to assess and reduce the effects of charged particle events on exotic atom X-ray measurements. Using this technique, the high-energy and low-energy components of the X-ray peaks due to pileup are eliminated, improving the energy resolution from 6.6 eV to 5.7 eV at 6.9 keV.
△ Less
Submitted 20 May, 2020; v1 submitted 14 July, 2019;
originally announced July 2019.
-
A Highly Linear Calibration Metric for TES X-ray Microcalorimeters
Authors:
C. G. Pappas,
J. W. Fowler,
D. A. Bennett,
W. B. Doriese,
Y. I. Joe,
K. M. Morgan,
G. C. O'Neil,
J. N. Ullom,
D. S. Swetz
Abstract:
Transition-edge sensor X-ray microcalorimeters are usually calibrated empirically, as the most widely-used calibration metric, optimal filtered pulse height (OFPH), in general has an unknown dependance on photon energy, $E_γ$. Because the calibration function can only be measured at specific points where photons of a known energy can be produced, this unknown dependence of OFPH on $E_γ$ leads to c…
▽ More
Transition-edge sensor X-ray microcalorimeters are usually calibrated empirically, as the most widely-used calibration metric, optimal filtered pulse height (OFPH), in general has an unknown dependance on photon energy, $E_γ$. Because the calibration function can only be measured at specific points where photons of a known energy can be produced, this unknown dependence of OFPH on $E_γ$ leads to calibration errors and the need for time-intensive calibration measurements and analysis. A calibration metric that is nearly linear as a function of $E_γ$ could help alleviate these problems. In this work, we assess the linearity of a physically motivated calibration metric, $E_{Joule}$. We measure calibration pulses in the range 4.5 keV$<$$E_γ$$<$9.6 keV with detectors optimized for 6 keV photons to compare the linearity properties of $E_{Joule}$ to OFPH. In these test data sets, we find that $E_{Joule}$ fits a linear function an order of magnitude better than OFPH. Furthermore, calibration functions using $E_{J}$, an optimized version of $E_{Joule}$, are linear within the 2-3 eV noise of the data.
△ Less
Submitted 1 August, 2018;
originally announced August 2018.
-
Approaches to the Optimal Nonlinear Analysis of Microcalorimeter Pulses
Authors:
J. W. Fowler,
C. G. Pappas,
B. K. Alpert,
W. B. Doriese,
G. C. O'Neil,
J. N. Ullom,
D. S. Swetz
Abstract:
We consider how to analyze microcalorimeter pulses for quantities that are nonlinear in the data, while preserving the signal-to-noise advantages of lin- ear optimal filtering. We successfully apply our chosen approach to compute the electrothermal feedback energy deficit (the "Joule energy") of a pulse, which has been proposed as a linear estimator of the deposited photon energy.
We consider how to analyze microcalorimeter pulses for quantities that are nonlinear in the data, while preserving the signal-to-noise advantages of lin- ear optimal filtering. We successfully apply our chosen approach to compute the electrothermal feedback energy deficit (the "Joule energy") of a pulse, which has been proposed as a linear estimator of the deposited photon energy.
△ Less
Submitted 6 March, 2018;
originally announced March 2018.
-
Microstructure analysis of bismuth absorbers for transition-edge sensor X-ray microcalorimeters
Authors:
Daikang Yan,
Ralu Divan,
Lisa M. Gades,
Peter Kenesei,
Timothy J. Madden,
Antonino Miceli,
Jun-Sang Park,
Umeshkumar M. Patel,
Orlando Quaranta,
Hemant Sharma,
Douglas A. Bennett,
William B. Doriese,
Joseph W. Fowler,
Johnathon Gard,
James Hays-Wehle,
Kelsey M. Morgan,
Daniel R. Schmidt,
Daniel S. Swetz,
Joel N. Ullom
Abstract:
Transition-edge sensors (TESs) as microcalorimeters offer high resolving power, owning to their sharp response and low operating temperature. In the hard X-ray regime and above, the demand for high quantum-efficiency requires the use of absorbers. Bismuth (Bi), owing to its low heat carrier density and high X-ray stop** power, has been widely used as an absorber material for TESs. However, disti…
▽ More
Transition-edge sensors (TESs) as microcalorimeters offer high resolving power, owning to their sharp response and low operating temperature. In the hard X-ray regime and above, the demand for high quantum-efficiency requires the use of absorbers. Bismuth (Bi), owing to its low heat carrier density and high X-ray stop** power, has been widely used as an absorber material for TESs. However, distinct spectral responses have been observed for Bi absorbers deposited via evaporation versus electroplating. Evaporated Bi absorbers are widely observed to have a non-Gaussian tail on the low energy side of measured spectra. In this study, we fabricated Bi absorbers via these two methods, and performed microstructure analysis using scanning electron microscopy (SEM) and X-ray diffraction microscopy. The two types of material showed the same crystallographic structure, but the grain size of the evaporated Bi was about 40 times smaller than that of the electroplated Bi. This distinction in grain size is likely to be the cause of their different spectral responses.
△ Less
Submitted 6 November, 2017;
originally announced November 2017.
-
Eliminating the non-Gaussian spectral response of X-ray absorbers for transition-edge sensors
Authors:
Daikang Yan,
Ralu Divan,
Lisa M. Gades,
Peter Kenesei,
Timothy J. Madden,
Antonino Miceli,
Jun-Sang Park,
Umeshkumar M. Patel,
Orlando Quaranta,
Hemant Sharma,
Douglas A. Bennett,
William B. Doriese,
Joseph W. Fowler,
Johnathon Gard,
James Hays-Wehle,
Kelsey M. Morgan,
Daniel R. Schmidt,
Daniel S. Swetz,
Joel N. Ullom
Abstract:
Transition-edge sensors (TES) as microcalorimeters for high-energy-resolution X-ray spectroscopy are often fabricated with an absorber made of materials with high Z (for X-ray stop** power) and low heat capacity (for high resolving power). Bismuth represents one of the most compelling options. TESs with evaporated bismuth absorbers have shown spectra with undesirable and unexplained low-energy t…
▽ More
Transition-edge sensors (TES) as microcalorimeters for high-energy-resolution X-ray spectroscopy are often fabricated with an absorber made of materials with high Z (for X-ray stop** power) and low heat capacity (for high resolving power). Bismuth represents one of the most compelling options. TESs with evaporated bismuth absorbers have shown spectra with undesirable and unexplained low-energy tails. We have developed TESs with electroplated bismuth absorbers over a gold layer that are not afflicted by this problem and that retain the other positive aspects of this material. To better understand these phenomena, we have studied a series of TESs with gold, gold/evaporated bismuth, and gold/electroplated bismuth absorbers, fabricated on the same die with identical thermal coupling. We show that bismuth morphology is linked to the spectral response of X-ray TES microcalorimeters.
△ Less
Submitted 28 August, 2017;
originally announced August 2017.
-
L-Edge Spectroscopy of Dilute, Radiation-Sensitive Systems Using a Transition-Edge-Sensor Array
Authors:
Charles J. Titus,
Michael L. Baker,
Sang Jun Lee,
Hsiao-mei Cho,
William B. Doriese,
Joseph W. Fowler,
Kelly Gaffney,
Johnathon D. Gard,
Gene C. Hilton,
Chris Kenney,
Jason Knight,
Dale Li,
Ron Marks,
Michael P. Minitti,
Kelsey M. Morgan,
Galen C. O'Neil,
Carl D. Reintsema,
Daniel R. Schmidt,
Dimosthenis Sokaras,
Daniel S. Swetz,
Joel N. Ullom,
Tsu-Chien Weng,
Christopher Williams,
Betty A. Young,
Kent D. Irwin
, et al. (2 additional authors not shown)
Abstract:
We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100-2000eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in ag…
▽ More
We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100-2000eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in agreement with high-concentration measurements recorded by conventional grating-based spectrometers. These results show that soft X-ray RIXS spectroscopy acquired by high-throughput TES spectrometers can be used to study the local electronic structure of dilute metal-centered complexes relevant to biology, chemistry and catalysis. In particular, TES spectrometers have a unique ability to characterize frozen solutions of radiation- and temperature-sensitive samples.
△ Less
Submitted 18 August, 2017; v1 submitted 29 June, 2017;
originally announced June 2017.
-
A Reassessment of Absolute Energies of the X-ray L Lines of Lanthanide Metals
Authors:
J. W. Fowler,
B. K. Alpert,
D. A. Bennett,
W. B. Doriese,
J. D. Gard,
G. C. Hilton,
L. T. Hudson,
Y. -I. Joe,
K. M. Morgan,
G. C. O'Neil,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
C. I. Szabo,
J. N. Ullom.
Abstract:
We introduce a new technique for determining x-ray fluorescence line energies and widths, and we present measurements made with this technique of 22 x-ray L lines from lanthanide-series elements. The technique uses arrays of transition-edge sensors, microcalorimeters with high energy-resolving power that simultaneously observe both calibrated x-ray standards and the x-ray emission lines under stud…
▽ More
We introduce a new technique for determining x-ray fluorescence line energies and widths, and we present measurements made with this technique of 22 x-ray L lines from lanthanide-series elements. The technique uses arrays of transition-edge sensors, microcalorimeters with high energy-resolving power that simultaneously observe both calibrated x-ray standards and the x-ray emission lines under study. The uncertainty in absolute line energies is generally less than 0.4 eV in the energy range of 4.5 keV to 7.5 keV. Of the seventeen line energies of neodymium, samarium, and holmium, thirteen are found to be consistent with the available x-ray reference data measured after 1990; only two of the four lines for which reference data predate 1980, however, are consistent with our results. Five lines of terbium are measured with uncertainties that improve on those of existing data by factors of two or more. These results eliminate a significant discrepancy between measured and calculated x-ray line energies for the terbium Ll line (5.551 keV). The line widths are also measured, with uncertainties of 0.6 eV or less on the full-width at half-maximum in most cases. These measurements were made with an array of approximately one hundred superconducting x- ray microcalorimeters, each sensitive to an energy band from 1 keV to 8 keV. No energy-dispersive spectrometer has previously been used for absolute-energy estimation at this level of accuracy. Future spectrometers, with superior linearity and energy resolution, will allow us to improve on these results and expand the measurements to more elements and a wider range of line energies.
△ Less
Submitted 10 May, 2017; v1 submitted 1 February, 2017;
originally announced February 2017.
-
When "Optimal Filtering" Isn't
Authors:
J. W. Fowler,
B. K. Alpert,
W. B. Doriese,
J. Hays-Wehle,
Y. -I. Joe,
K. M. Morgan,
G. C. O'Neil,
C. D. Reintsema,
D. R. Schmidt,
J. N. Ullom,
D. S. Swetz
Abstract:
The so-called "optimal filter" analysis of a microcalorimeter's x-ray pulses is statistically optimal only if all pulses have the same shape, regardless of energy. The shapes of pulses from a nonlinear detector can and do depend on the pulse energy, however. A pulse-fitting procedure that we call "tangent filtering" accounts for the energy dependence of the shape and should therefore achieve super…
▽ More
The so-called "optimal filter" analysis of a microcalorimeter's x-ray pulses is statistically optimal only if all pulses have the same shape, regardless of energy. The shapes of pulses from a nonlinear detector can and do depend on the pulse energy, however. A pulse-fitting procedure that we call "tangent filtering" accounts for the energy dependence of the shape and should therefore achieve superior energy resolution. We take a geometric view of the pulse-fitting problem and give expressions to predict how much the energy resolution stands to benefit from such a procedure. We also demonstrate the method with a case study of K-line fluorescence from several 3d transition metals. The method improves the resolution from 4.9 eV to 4.2 eV at the Cu K$α$ line (8.0keV).
△ Less
Submitted 23 November, 2016;
originally announced November 2016.
-
First application of superconducting transition-edge-sensor microcalorimeters to hadronic-atom x-ray spectroscopy
Authors:
S. Okada,
D. A. Bennett,
C. Curceanu,
W. B. Doriese,
J. W. Fowler,
J. Gard,
F. P. Gustafsson,
T. Hashimoto,
R. S. Hayano,
S. Hirenzaki,
J. P. Hays-Wehle,
G. C. Hilton,
N. Ikeno,
M. Iliescu,
S. Ishimoto,
K. Itahashi,
M. Iwasaki,
T. Koike,
K. Kuwabara,
Y. Ma,
J. Marton,
H. Noda,
G. C. O'Neil,
H. Outa,
C. D. Reintsema
, et al. (13 additional authors not shown)
Abstract:
High-resolution pionic-atom x-ray spectroscopy was performed with an x-ray spectrometer based on a 240-pixel array of superconducting transition-edge-sensor (TES) microcalorimeters at the piM1 beam line of the Paul Scherrer Institute. X-rays emitted by pionic carbon via the 4f->3d transition and the parallel 4d->3p transition were observed with a full-width-at-half-maximum energy resolution of 6.8…
▽ More
High-resolution pionic-atom x-ray spectroscopy was performed with an x-ray spectrometer based on a 240-pixel array of superconducting transition-edge-sensor (TES) microcalorimeters at the piM1 beam line of the Paul Scherrer Institute. X-rays emitted by pionic carbon via the 4f->3d transition and the parallel 4d->3p transition were observed with a full-width-at-half-maximum energy resolution of 6.8 eV at 6.4 keV. Measured x-ray energies are consistent with calculated electromagnetic values which considered the strong-interaction effect assessed via the Seki-Masutani potential for the 3p energy level, and favor the electronic population of two filled 1s electrons in the K-shell. Absolute energy calibration with an uncertainty of 0.1 eV was demonstrated under a high-rate hadron beam condition of 1.45 MHz. This is the first application of a TES spectrometer to hadronic-atom x-ray spectroscopy and is an important milestone towards next-generation high-resolution kaonic-atom x-ray spectroscopy.
△ Less
Submitted 18 August, 2016;
originally announced August 2016.
-
Absolute Energy Calibration of X-ray TESs with 0.04 eV Uncertainty at 6.4 keV in a Hadron-Beam Environment
Authors:
H. Tatsuno,
W. B. Doriese,
D. A. Bennett,
C. Curceanu,
J. W. Fowler,
J. Gard,
F. P. Gustafsson,
T. Hashimoto,
R. S. Hayano,
J. P. Hays-Wehle,
G. C. Hilton,
M. Iliescu,
S. Ishimoto,
K. Itahashi,
M. Iwasaki,
K. Kuwabara,
Y. Ma,
J. Marton,
H. Noda,
G. C. O'Neil,
S. Okada,
H. Outa,
C. D. Reintsema,
M. Sato,
D. R. Schmidt
, et al. (9 additional authors not shown)
Abstract:
A performance evaluation of superconducting transition-edge sensors (TESs) in the environment of a pion beam line at a particle accelerator is presented. Averaged across the 209 functioning sensors in the array, the achieved energy resolution is 5.2 eV FWHM at Co $K_α$ (6.9 keV) when the pion beam is off and 7.3 eV at a beam rate of 1.45 MHz. Absolute energy uncertainty of $\pm$0.04 eV is demonstr…
▽ More
A performance evaluation of superconducting transition-edge sensors (TESs) in the environment of a pion beam line at a particle accelerator is presented. Averaged across the 209 functioning sensors in the array, the achieved energy resolution is 5.2 eV FWHM at Co $K_α$ (6.9 keV) when the pion beam is off and 7.3 eV at a beam rate of 1.45 MHz. Absolute energy uncertainty of $\pm$0.04 eV is demonstrated for Fe $K_α$ (6.4 keV) with in-situ energy calibration obtained from other nearby known x-ray lines. To achieve this small uncertainty, it is essential to consider the non-Gaussian energy response of the TESs and thermal cross-talk pile-up effects due to charged-particle hits in the silicon substrate of the TES array.
△ Less
Submitted 13 January, 2016;
originally announced January 2016.
-
The Practice of Pulse Processing
Authors:
J. W. Fowler,
B. K. Alpert,
W. B. Doriese,
Y. -I. Joe,
G. C. O'Neil,
J. N. Ullom,
D. S. Swetz
Abstract:
The analysis of data from x-ray microcalorimeters requires great care; their excellent intrinsic energy resolution cannot usually be achieved in practice without a statistically near-optimal pulse analysis and corrections for important systematic errors. We describe the essential parts of a pulse-analysis pipeline for data from x-ray microcalorimeters, including steps taken to reduce systematic ga…
▽ More
The analysis of data from x-ray microcalorimeters requires great care; their excellent intrinsic energy resolution cannot usually be achieved in practice without a statistically near-optimal pulse analysis and corrections for important systematic errors. We describe the essential parts of a pulse-analysis pipeline for data from x-ray microcalorimeters, including steps taken to reduce systematic gain variation and the unwelcome dependence of filtered pulse heights on the exact pulse-arrival time. We find these steps collectively to be essential tools for getting the best results from a microcalorimeter-based x-ray spectrometer.
△ Less
Submitted 12 November, 2015;
originally announced November 2015.
-
Microcalorimeter Spectroscopy at High Pulse Rates: a Multi-Pulse Fitting Technique
Authors:
J. W. Fowler,
B. K. Alpert,
W. B. Doriese,
D. A. Fischer,
C. Jaye,
Y. I. Joe,
G. C. O'Neil,
D. S. Swetz,
J. N. Ullom
Abstract:
Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each sensor must be able to measure hundreds or even thousands of photon energies per second. Current "optimal filtering" approaches to achieve the best possible energ…
▽ More
Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each sensor must be able to measure hundreds or even thousands of photon energies per second. Current "optimal filtering" approaches to achieve the best possible energy resolution work only for photons well isolated in time, a requirement in direct conflict with the need for high-rate measurements. We describe a new analysis procedure to allow fitting for the pulse height of all photons even in the presence of heavy pulse pile-up. In the limit of isolated pulses, the technique reduces to the standard optimal filtering with long records. We employ reasonable approximations to the noise covariance function in order to render multi-pulse fitting computationally viable even for very long data records. The technique is employed to analyze x-ray emission spectra at 600 eV and 6 keV at rates up to 250 counts per second in microcalorimeters having exponential signal decay times of approximately 1.2 ms.
△ Less
Submitted 31 March, 2015; v1 submitted 20 March, 2015;
originally announced March 2015.
-
High-resolution kaonic-atom x-ray spectroscopy with transition-edge-sensor microcalorimeters
Authors:
S. Okada,
D. A. Bennett,
W. B. Doriese,
J. W. Fowler,
K. D. Irwin,
S. Ishimoto,
M. Sato,
D. R. Schmidt,
D. S. Swetz,
H. Tatsuno,
J. N. Ullom,
S. Yamada
Abstract:
We are preparing for an ultra-high resolution x-ray spectroscopy of kaonic atoms using an x-ray spectrometer based on an array of superconducting transition-edge-sensor microcalorimeters developed by NIST. The instrument has excellent energy resolutions of 2 - 3 eV (FWHM) at 6 keV and a large collecting area of about 20 mm^2. This will open new door to investigate kaon-nucleus strong interaction a…
▽ More
We are preparing for an ultra-high resolution x-ray spectroscopy of kaonic atoms using an x-ray spectrometer based on an array of superconducting transition-edge-sensor microcalorimeters developed by NIST. The instrument has excellent energy resolutions of 2 - 3 eV (FWHM) at 6 keV and a large collecting area of about 20 mm^2. This will open new door to investigate kaon-nucleus strong interaction and provide new accurate charged-kaon mass value.
△ Less
Submitted 18 February, 2014; v1 submitted 30 January, 2014;
originally announced January 2014.
-
Transition-Edge Sensors for Particle Induced X-ray Emission Measurements
Authors:
M. R. J. Palosaari,
K. M. Kinnunen,
J. Julin,
M. Laitinen,
M. Napari,
T. Sajavaara,
W. B. Doriese,
J. Fowler,
C. Reintsema,
D. Swetz,
D. Schmidt,
J. Ullom,
I. J. Maasilta
Abstract:
In this paper we present a new measurement setup, where a transitionedge sensor detector array is used to detect X-rays in particle induced X-ray emission measurements with a 2 MeV proton beam. Transition-edge sensors offer orders of magnitude improvement in energy resolution compared to conventional silicon or germanium detectors, making it possible to recognize spectral lines in materials analys…
▽ More
In this paper we present a new measurement setup, where a transitionedge sensor detector array is used to detect X-rays in particle induced X-ray emission measurements with a 2 MeV proton beam. Transition-edge sensors offer orders of magnitude improvement in energy resolution compared to conventional silicon or germanium detectors, making it possible to recognize spectral lines in materials analysis that have previously been impossible to resolve, and to get chemical information from the elements. Our sensors are cooled to the operation temperature (65 mK) with a cryogen-free adiabatic demagnetization refrigerator, which houses a specially designed X-ray snout that has a vacuum tight window to couple in the radiation. For the best pixel, the measured instrumental energy resolution was 3.06 eV full width at half maximum at 5.9 keV.We discuss the current status of the project, benefits of transition-edge sensors when used in particle induced X-ray emission spectroscopy, and the results from the first measurements.
△ Less
Submitted 7 October, 2013;
originally announced October 2013.
-
The Hot and Energetic Universe: The X-ray Integral Field Unit (X-IFU) for Athena+
Authors:
D. Barret,
J. W. den Herder,
L. Piro,
L. Ravera,
R. Den Hartog,
C. Macculi,
X. Barcons,
M. Page,
S. Paltani,
G. Rauw,
J. Wilms,
M. Ceballos,
L. Duband,
L. Gottardi,
S. Lotti,
J. de Plaa,
E. Pointecouteau,
C. Schmid,
H. Akamatsu,
D. Bagliani,
S. Bandler,
M. Barbera,
P. Bastia,
M. Biasotti,
M. Branco
, et al. (33 additional authors not shown)
Abstract:
The Athena+ mission concept is designed to implement the Hot and Energetic Universe science theme submitted to the European Space Agency in response to the call for White Papers for the definition of the L2 and L3 missions of its science program. The Athena+ science payload consists of a large aperture high angular resolution X-ray optics and twelve meters away, two interchangeable focal plane ins…
▽ More
The Athena+ mission concept is designed to implement the Hot and Energetic Universe science theme submitted to the European Space Agency in response to the call for White Papers for the definition of the L2 and L3 missions of its science program. The Athena+ science payload consists of a large aperture high angular resolution X-ray optics and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager (WFI). The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), offering 2.5 eV spectral resolution, with ~5" pixels, over a field of view of 5 arc minutes in diameter. In this paper, we briefly describe the Athena+ mission concept and the X-IFU performance requirements. We then present the X-IFU detector and readout electronics principles, the current design of the focal plane assembly, the cooling chain and review the global architecture design. Finally, we describe the current performance estimates, in terms of effective area, particle background rejection, count rate capability and velocity measurements. Finally, we emphasize on the latest technology developments concerning TES array fabrication, spectral resolution and readout performance achieved to show that significant progresses are being accomplished towards the demanding X-IFU requirements.
△ Less
Submitted 30 August, 2013;
originally announced August 2013.
-
SCUBA-2: The 10000 pixel bolometer camera on the James Clerk Maxwell Telescope
Authors:
W. S. Holland,
D. Bintley,
E. L. Chapin,
A. Chrysostomou,
G. R. Davis,
J. T. Dempsey,
W. D. Duncan,
M. Fich,
P. Friberg,
M. Halpern,
K. D. Irwin,
T. Jenness,
B. D. Kelly,
M. J. MacIntosh,
E. I. Robson,
D. Scott,
P. A. R. Ade,
E. Atad-Ettedgui,
D. S. Berry,
S. C. Craig,
X. Gao,
A. G. Gibb,
G. C. Hilton,
M. I. Hollister,
J. B. Kycia
, et al. (24 additional authors not shown)
Abstract:
SCUBA-2 is an innovative 10000 pixel bolometer camera operating at submillimetre wavelengths on the James Clerk Maxwell Telescope (JCMT). The camera has the capability to carry out wide-field surveys to unprecedented depths, addressing key questions relating to the origins of galaxies, stars and planets. With two imaging arrays working simultaneously in the atmospheric windows at 450 and 850 micro…
▽ More
SCUBA-2 is an innovative 10000 pixel bolometer camera operating at submillimetre wavelengths on the James Clerk Maxwell Telescope (JCMT). The camera has the capability to carry out wide-field surveys to unprecedented depths, addressing key questions relating to the origins of galaxies, stars and planets. With two imaging arrays working simultaneously in the atmospheric windows at 450 and 850 microns, the vast increase in pixel count means that SCUBA-2 maps the sky 100-150 times faster than the previous SCUBA instrument. In this paper we present an overview of the instrument, discuss the physical characteristics of the superconducting detector arrays, outline the observing modes and data acquisition, and present the early performance figures on the telescope. We also showcase the capabilities of the instrument via some early examples of the science SCUBA-2 has already undertaken. In February 2012, SCUBA-2 began a series of unique legacy surveys for the JCMT community. These surveys will take 2.5 years and the results are already providing complementary data to the shorter wavelength, shallower, larger-area surveys from Herschel. The SCUBA-2 surveys will also provide a wealth of information for further study with new facilities such as ALMA, and future telescopes such as CCAT and SPICA.
△ Less
Submitted 16 January, 2013;
originally announced January 2013.
-
The Atacama Cosmology Telescope: Cosmological parameters from three seasons of data
Authors:
Jonathan L. Sievers,
Renée A. Hlozek,
Michael R. Nolta,
Viviana Acquaviva,
Graeme E. Addison,
Peter A. R. Ade,
Paula Aguirre,
Mandana Amiri,
John William Appel,
L. Felipe Barrientos,
Elia S. Battistelli,
Nick Battaglia,
J. Richard Bond,
Ben Brown,
Bryce Burger,
Erminia Calabrese,
Jay Chervenak,
Devin Crichton,
Sudeep Das,
Mark J. Devlin,
Simon R. Dicker,
W. Bertrand Doriese,
Joanna Dunkley,
Rolando Dünner,
Thomas Essinger-Hileman
, et al. (68 additional authors not shown)
Abstract:
We present constraints on cosmological and astrophysical parameters from high-resolution microwave background maps at 148 GHz and 218 GHz made by the Atacama Cosmology Telescope (ACT) in three seasons of observations from 2008 to 2010. A model of primary cosmological and secondary foreground parameters is fit to the map power spectra and lensing deflection power spectrum, including contributions f…
▽ More
We present constraints on cosmological and astrophysical parameters from high-resolution microwave background maps at 148 GHz and 218 GHz made by the Atacama Cosmology Telescope (ACT) in three seasons of observations from 2008 to 2010. A model of primary cosmological and secondary foreground parameters is fit to the map power spectra and lensing deflection power spectrum, including contributions from both the thermal Sunyaev-Zeldovich (tSZ) effect and the kinematic Sunyaev-Zeldovich (kSZ) effect, Poisson and correlated anisotropy from unresolved infrared sources, radio sources, and the correlation between the tSZ effect and infrared sources. The power ell^2 C_ell/2pi of the thermal SZ power spectrum at 148 GHz is measured to be 3.4 +\- 1.4 muK^2 at ell=3000, while the corresponding amplitude of the kinematic SZ power spectrum has a 95% confidence level upper limit of 8.6 muK^2. Combining ACT power spectra with the WMAP 7-year temperature and polarization power spectra, we find excellent consistency with the LCDM model. We constrain the number of effective relativistic degrees of freedom in the early universe to be Neff=2.79 +\- 0.56, in agreement with the canonical value of Neff=3.046 for three massless neutrinos. We constrain the sum of the neutrino masses to be Sigma m_nu < 0.39 eV at 95% confidence when combining ACT and WMAP 7-year data with BAO and Hubble constant measurements. We constrain the amount of primordial helium to be Yp = 0.225 +\- 0.034, and measure no variation in the fine structure constant alpha since recombination, with alpha/alpha0 = 1.004 +/- 0.005. We also find no evidence for any running of the scalar spectral index, dns/dlnk = -0.004 +\- 0.012.
△ Less
Submitted 11 October, 2013; v1 submitted 4 January, 2013;
originally announced January 2013.
-
Filters for High Rate Pulse Processing
Authors:
B. K. Alpert,
R. D. Horansky,
D. A. Bennett,
W. B. Doriese,
J. W. Fowler,
A. S. Hoover,
M. W. Rabin,
J. N. Ullom
Abstract:
We introduce a filter-construction method for pulse processing that differs in two respects from that in standard optimal filtering, in which the average pulse shape and noise-power spectral density are combined to create a convolution filter for estimating pulse heights. First, the proposed filters are computed in the time domain, to avoid periodicity artifacts of the discrete Fourier transform,…
▽ More
We introduce a filter-construction method for pulse processing that differs in two respects from that in standard optimal filtering, in which the average pulse shape and noise-power spectral density are combined to create a convolution filter for estimating pulse heights. First, the proposed filters are computed in the time domain, to avoid periodicity artifacts of the discrete Fourier transform, and second, orthogonality constraints are imposed on the filters, to reduce the filtering procedure's sensitivity to unknown baseline height and pulse tails. We analyze the proposed filters, predicting energy resolution under several scenarios, and apply the filters to high-rate pulse data from gamma-rays measured by a transition-edge-sensor microcalorimeter.
△ Less
Submitted 7 December, 2012;
originally announced December 2012.
-
The Atacama Cosmology Telescope: Data Characterization and Map Making
Authors:
Rolando Dünner,
Matthew Hasselfield,
Tobias A. Marriage,
Jon Sievers,
Viviana Acquaviva,
Graeme E. Addison,
Peter A. R. Ade,
Paula Aguirre,
Mandana Amiri,
John William Appel,
L. Felipe Barrientos,
Elia S. Battistelli,
J. Richard Bond,
Ben Brown,
Bryce Burger,
Erminia Calabrese,
Jay Chervenak,
Sudeep Das,
Mark J. Devlin,
Simon R. Dicker,
W. Bertrand Doriese,
Joanna Dunkley,
Thomas Essinger-Hileman,
Ryan P. Fisher,
Megan B. Gralla
, et al. (49 additional authors not shown)
Abstract:
We present a description of the data reduction and mapmaking pipeline used for the 2008 observing season of the Atacama Cosmology Telescope (ACT). The data presented here at 148 GHz represent 12% of the 90 TB collected by ACT from 2007 to 2010. In 2008 we observed for 136 days, producing a total of 1423 hours of data (11 TB for the 148 GHz band only), with a daily average of 10.5 hours of observat…
▽ More
We present a description of the data reduction and mapmaking pipeline used for the 2008 observing season of the Atacama Cosmology Telescope (ACT). The data presented here at 148 GHz represent 12% of the 90 TB collected by ACT from 2007 to 2010. In 2008 we observed for 136 days, producing a total of 1423 hours of data (11 TB for the 148 GHz band only), with a daily average of 10.5 hours of observation. From these, 1085 hours were devoted to a 850 deg^2 stripe (11.2 hours by 9.1 deg) centered on a declination of -52.7 deg, while 175 hours were devoted to a 280 deg^2 stripe (4.5 hours by 4.8 deg) centered at the celestial equator. We discuss sources of statistical and systematic noise, calibration, telescope pointing, and data selection. Out of 1260 survey hours and 1024 detectors per array, 816 hours and 593 effective detectors remain after data selection for this frequency band, yielding a 38% survey efficiency. The total sensitivity in 2008, determined from the noise level between 5 Hz and 20 Hz in the time-ordered data stream (TOD), is 32 micro-Kelvin sqrt{s} in CMB units. Atmospheric brightness fluctuations constitute the main contaminant in the data and dominate the detector noise covariance at low frequencies in the TOD. The maps were made by solving the least-squares problem using the Preconditioned Conjugate Gradient method, incorporating the details of the detector and noise correlations. Cross-correlation with WMAP sky maps, as well as analysis from simulations, reveal that our maps are unbiased at multipoles ell > 300. This paper accompanies the public release of the 148 GHz southern stripe maps from 2008. The techniques described here will be applied to future maps and data releases.
△ Less
Submitted 2 August, 2012; v1 submitted 31 July, 2012;
originally announced August 2012.
-
Code-division multiplexing for x-ray microcalorimeters
Authors:
G. M. Stiehl,
W. B. Doriese,
J. W. Fowler,
G. C. Hilton,
K. D. Irwin,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R. Vale.
Abstract:
We demonstrate the code-division multiplexed (CDM) readout of eight transition-edge sensor microcalorimeters. The energy resolution is 3.0 eV (full width at half-maximum) or better at 5.9 keV, with a best resolution of 2.3 eV and a mean of 2.6 eV over the seven modulated detectors. The flux-summing CDM system is described and compared with similar time-division multiplexed (TDM) readout. We show t…
▽ More
We demonstrate the code-division multiplexed (CDM) readout of eight transition-edge sensor microcalorimeters. The energy resolution is 3.0 eV (full width at half-maximum) or better at 5.9 keV, with a best resolution of 2.3 eV and a mean of 2.6 eV over the seven modulated detectors. The flux-summing CDM system is described and compared with similar time-division multiplexed (TDM) readout. We show that the sqrt(Npixels) multiplexing disadvantage associated with TDM is not present in CDM. This demonstration establishes CDM as both a simple route to higher performance in existing TDM microcalorimetric experiments and a long-term approach to reaching higher multiplexing factors.
△ Less
Submitted 30 January, 2012;
originally announced January 2012.
-
Optimization and analysis of code-division multiplexed TES microcalorimeters
Authors:
J. W. Fowler,
W. B. Doriese,
G. C. Hilton,
K. D. Irwin,
D. R. Schmidt,
G. M. Stiehl,
D. S. Swetz,
J. N. Ullom,
L. R. Vale.
Abstract:
We are develo** code-division multiplexing (CDM) systems for transition-edge sensor arrays with the goal of reaching multiplexing factors in the hundreds. We report on x-ray measurements made with a four-channel prototype CDM system that employs a flux-summing architecture, emphasizing data-analysis issues. We describe an empirical method to determine the demodulation matrix that minimizes cross…
▽ More
We are develo** code-division multiplexing (CDM) systems for transition-edge sensor arrays with the goal of reaching multiplexing factors in the hundreds. We report on x-ray measurements made with a four-channel prototype CDM system that employs a flux-summing architecture, emphasizing data-analysis issues. We describe an empirical method to determine the demodulation matrix that minimizes cross-talk. This CDM system achieves energy resolutions of between 2.3 eV and 3.0 eV FWHM at 5.9 keV.
△ Less
Submitted 11 October, 2011;
originally announced October 2011.
-
Advanced code-division multiplexers for superconducting detector arrays
Authors:
K. D. Irwin,
H. M. Cho,
W. B. Doriese,
J. W. Fowler,
G. C. Hilton,
M. D. Niemack,
C. D. Reintsema,
D. R. Schmidt,
J. N. Ullom,
L. R. Vale
Abstract:
Multiplexers based on the modulation of superconducting quantum interference devices are now regularly used in multi-kilopixel arrays of superconducting detectors for astrophysics, cosmology, and materials analysis. Over the next decade, much larger arrays will be needed. These larger arrays require new modulation techniques and compact multiplexer elements that fit within each pixel. We present a…
▽ More
Multiplexers based on the modulation of superconducting quantum interference devices are now regularly used in multi-kilopixel arrays of superconducting detectors for astrophysics, cosmology, and materials analysis. Over the next decade, much larger arrays will be needed. These larger arrays require new modulation techniques and compact multiplexer elements that fit within each pixel. We present a new in-focal-plane code-division multiplexer that provides multiplexing elements with the required scalability. This code-division multiplexer uses compact lithographic modulation elements that simultaneously multiplex both signal outputs and superconducting transition-edge sensor (TES) detector bias voltages. It eliminates the shunt resistor used to voltage bias TES detectors, greatly reduces power dissipation, allows different dc bias voltages for each TES, and makes all elements sufficiently compact to fit inside the detector pixel area. These in-focal-plane code-division multiplexers can be combined with multi-gigahertz readout based on superconducting microresonators to scale to even larger arrays.
△ Less
Submitted 7 October, 2011;
originally announced October 2011.
-
The Atacama Cosmology Telescope: Sunyaev Zel'dovich Selected Galaxy Clusters at 148 GHz in the 2008 Survey
Authors:
T. A. Marriage,
V. Acquaviva,
P. A. R. Ade,
P. Aguirre,
M. Amiri,
J. W. Appel,
L. F. Barrientos,
E. S. Battistelli,
J. R. Bond,
B. Brown,
B. Burger,
J. Chervenak,
S. Das,
M. J. Devlin,
S. R. Dicker,
W. B. Doriese,
J. Dunkley,
R. Dunner,
T. Essinger-Hileman,
R. P. Fisher,
J. W. Fowler,
A. Hajian,
M. Halpern,
M. Hasselfield,
C. Hern'andez-Monteagudo
, et al. (46 additional authors not shown)
Abstract:
We report on twenty-three clusters detected blindly as Sunyaev-Zel'dovich (SZ) decrements in a 148 GHz, 455 square-degree map of the southern sky made with data from the Atacama Cosmology Telescope 2008 observing season. All SZ detections announced in this work have confirmed optical counterparts. Ten of the clusters are new discoveries. One newly discovered cluster, ACT-CL J0102-4915, with a reds…
▽ More
We report on twenty-three clusters detected blindly as Sunyaev-Zel'dovich (SZ) decrements in a 148 GHz, 455 square-degree map of the southern sky made with data from the Atacama Cosmology Telescope 2008 observing season. All SZ detections announced in this work have confirmed optical counterparts. Ten of the clusters are new discoveries. One newly discovered cluster, ACT-CL J0102-4915, with a redshift of 0.75 (photometric), has an SZ decrement comparable to the most massive systems at lower redshifts. Simulations of the cluster recovery method reproduce the sample purity measured by optical follow-up. In particular, for clusters detected with a signal-to-noise ratio greater than six, simulations are consistent with optical follow-up that demonstrated this subsample is 100% pure. The simulations further imply that the total sample is 80% complete for clusters with mass in excess of 6x10^14 solar masses referenced to the cluster volume characterized by five hundred times the critical density. The Compton y -- X-ray luminosity mass comparison for the eleven best detected clusters visually agrees with both self-similar and non-adiabatic, simulation-derived scaling laws.
△ Less
Submitted 23 June, 2011; v1 submitted 6 October, 2010;
originally announced October 2010.
-
The Atacama Cosmology Telescope: Cosmology from Galaxy Clusters Detected via the Sunyaev-Zel'dovich Effect
Authors:
Neelima Sehgal,
Hy Trac,
Viviana Acquaviva,
Peter A. R. Ade,
Paula Aguirre,
Mandana Amiri,
John W. Appel,
L. Felipe Barrientos,
Elia S. Battistelli,
J. Richard Bond,
Ben Brown,
Bryce Burger,
Jay Chervenak,
Sudeep Das,
Mark J. Devlin,
Simon R. Dicker,
W. Bertrand Doriese,
Joanna Dunkley,
Rolando Dünner,
Thomas Essinger-Hileman,
Ryan P. Fisher,
Joseph W. Fowler,
Amir Hajian,
Mark Halpern,
Matthew Hasselfield
, et al. (44 additional authors not shown)
Abstract:
We present constraints on cosmological parameters based on a sample of Sunyaev-Zel'dovich-selected galaxy clusters detected in a millimeter-wave survey by the Atacama Cosmology Telescope. The cluster sample used in this analysis consists of 9 optically-confirmed high-mass clusters comprising the high-significance end of the total cluster sample identified in 455 square degrees of sky surveyed duri…
▽ More
We present constraints on cosmological parameters based on a sample of Sunyaev-Zel'dovich-selected galaxy clusters detected in a millimeter-wave survey by the Atacama Cosmology Telescope. The cluster sample used in this analysis consists of 9 optically-confirmed high-mass clusters comprising the high-significance end of the total cluster sample identified in 455 square degrees of sky surveyed during 2008 at 148 GHz. We focus on the most massive systems to reduce the degeneracy between unknown cluster astrophysics and cosmology derived from SZ surveys. We describe the scaling relation between cluster mass and SZ signal with a 4-parameter fit. Marginalizing over the values of the parameters in this fit with conservative priors gives sigma_8 = 0.851 +/- 0.115 and w = -1.14 +/- 0.35 for a spatially-flat wCDM cosmological model with WMAP 7-year priors on cosmological parameters. This gives a modest improvement in statistical uncertainty over WMAP 7-year constraints alone. Fixing the scaling relation between cluster mass and SZ signal to a fiducial relation obtained from numerical simulations and calibrated by X-ray observations, we find sigma_8 = 0.821 +/- 0.044 and w = -1.05 +/- 0.20. These results are consistent with constraints from WMAP 7 plus baryon acoustic oscillations plus type Ia supernoava which give sigma_8 = 0.802 +/- 0.038 and w = -0.98 +/- 0.053. A stacking analysis of the clusters in this sample compared to clusters simulated assuming the fiducial model also shows good agreement. These results suggest that, given the sample of clusters used here, both the astrophysics of massive clusters and the cosmological parameters derived from them are broadly consistent with current models.
△ Less
Submitted 5 October, 2010;
originally announced October 2010.
-
The Atacama Cosmology Telescope: Cosmological Parameters from the 2008 Power Spectra
Authors:
J. Dunkley,
R. Hlozek,
J. Sievers,
V. Acquaviva,
P. A. R. Ade,
P. Aguirre,
M. Amiri,
J. W. Appel,
L. F. Barrientos,
E. S. Battistelli,
J. R. Bond,
B. Brown,
B. Burger,
J. Chervenak,
S. Das,
M. J. Devlin,
S. R. Dicker,
W. Bertrand Doriese,
R. Dunner,
T. Essinger-Hileman,
R. P. Fisher,
J. W. Fowler,
A. Hajian,
M. Halpern,
M. Hasselfield
, et al. (42 additional authors not shown)
Abstract:
We present cosmological parameters derived from the angular power spectrum of the cosmic microwave background (CMB) radiation observed at 148 GHz and 218 GHz over 296 deg^2 with the Atacama Cosmology Telescope (ACT) during its 2008 season. ACT measures fluctuations at scales 500<l<10000. We fit a model for the lensed CMB, Sunyaev-Zel'dovich (SZ), and foreground contribution to the 148 GHz and 218…
▽ More
We present cosmological parameters derived from the angular power spectrum of the cosmic microwave background (CMB) radiation observed at 148 GHz and 218 GHz over 296 deg^2 with the Atacama Cosmology Telescope (ACT) during its 2008 season. ACT measures fluctuations at scales 500<l<10000. We fit a model for the lensed CMB, Sunyaev-Zel'dovich (SZ), and foreground contribution to the 148 GHz and 218 GHz power spectra, including thermal and kinetic SZ, Poisson power from radio and infrared point sources, and clustered power from infrared point sources. The power from thermal and kinetic SZ at 148 GHz is estimated to be B_3000 = 6.8+-2.9 uK^2, where B_l=l(l+1)C_l/2pi. We estimate primary cosmological parameters from the 148 GHz spectrum, marginalizing over SZ and source power. The LCDM cosmological model is a good fit to the data, and LCDM parameters estimated from ACT+WMAP are consistent with the 7-year WMAP limits, with scale invariant n_s = 1 excluded at 99.7% CL (3sigma). A model with no CMB lensing is disfavored at 2.8sigma. By measuring the third to seventh acoustic peaks, and probing the Silk dam** regime, the ACT data improve limits on cosmological parameters that affect the small-scale CMB power. The ACT data combined with WMAP give a 6sigma detection of primordial helium, with Y_P = 0.313+-0.044, and a 4sigma detection of relativistic species, assumed to be neutrinos, with Neff = 5.3+-1.3 (4.6+-0.8 with BAO+H0 data). From the CMB alone the running of the spectral index is constrained to be dn/dlnk = -0.034 +- 0.018, the limit on the tensor-to-scalar ratio is r<0.25 (95% CL), and the possible contribution of Nambu cosmic strings to the power spectrum is constrained to string tension Gmu<1.6 \times 10^-7 (95% CL).
△ Less
Submitted 4 September, 2010;
originally announced September 2010.
-
The Atacama Cosmology Telescope: A Measurement of the Cosmic Microwave Background Power Spectrum at 148 and 218 GHz from the 2008 Southern Survey
Authors:
Sudeep Das,
Tobias A. Marriage,
Peter A. R. Ade,
Paula Aguirre,
Mandana Amir,
John W. Appel,
L. Felipe Barrientos,
Elia S. Battistelli,
J. Richard Bond,
Ben Brown,
Bryce Burger,
Jay Chervenak,
Mark J. Devlin,
Simon R. Dicker,
W. Bertrand Doriese,
Joanna Dunkley,
Rolando Dünner,
Thomas Essinger-Hileman,
Ryan P. Fisher,
Joseph W. Fowler,
Amir Hajian,
Mark Halpern,
Matthew Hasselfield,
Carlos Hernández-Monteagudo,
Gene C. Hilton
, et al. (42 additional authors not shown)
Abstract:
We present measurements of the cosmic microwave background (CMB) power spectrum made by the Atacama Cosmology Telescope at 148 GHz and 218 GHz, as well as the cross-frequency spectrum between the two channels. Our results clearly show the second through the seventh acoustic peaks in the CMB power spectrum. The measurements of these higher-order peaks provide an additional test of the ΛCDM cosmolog…
▽ More
We present measurements of the cosmic microwave background (CMB) power spectrum made by the Atacama Cosmology Telescope at 148 GHz and 218 GHz, as well as the cross-frequency spectrum between the two channels. Our results clearly show the second through the seventh acoustic peaks in the CMB power spectrum. The measurements of these higher-order peaks provide an additional test of the ΛCDM cosmological model. At l > 3000, we detect power in excess of the primary anisotropy spectrum of the CMB. At lower multipoles 500 < l < 3000, we find evidence for gravitational lensing of the CMB in the power spectrum at the 2.8σ level. We also detect a low level of Galactic dust in our maps, which demonstrates that we can recover known faint, diffuse signals.
△ Less
Submitted 4 September, 2010;
originally announced September 2010.
-
The Atacama Cosmology Telescope: Calibration with WMAP Using Cross-Correlations
Authors:
Amir Hajian,
Viviana Acquaviva,
Peter A. R. Ade,
Paula Aguirre,
Mandana Amiri,
John William Appel,
L. Felipe Barrientos,
Elia S. Battistelli,
J. Richard Bond,
Ben Brown,
Bryce Burger,
Jay Chervenak,
Sudeep Das,
Mark J. Devlin,
Simon R. Dicker,
W. Bertrand Doriese,
Joanna Dunkley,
Rolando Dunner,
Thomas Essinger-Hileman,
Ryan P. Fisher,
Joseph W. Fowler,
Mark Halpern,
Matthew Hasselfield,
Carlos Hernandez-Monteagudo,
Gene C. Hilton
, et al. (42 additional authors not shown)
Abstract:
We present a new calibration method based on cross-correlations with WMAP and apply it to data from the Atacama Cosmology Telescope (ACT). ACT's observing strategy and map making procedure allows an unbiased reconstruction of the modes in the maps over a wide range of multipoles. By directly matching the ACT maps to WMAP observations in the multipole range of 400 < ell < 1000, we determine the abs…
▽ More
We present a new calibration method based on cross-correlations with WMAP and apply it to data from the Atacama Cosmology Telescope (ACT). ACT's observing strategy and map making procedure allows an unbiased reconstruction of the modes in the maps over a wide range of multipoles. By directly matching the ACT maps to WMAP observations in the multipole range of 400 < ell < 1000, we determine the absolute calibration with an uncertainty of 2% in temperature. The precise measurement of the calibration error directly impacts the uncertainties in the cosmological parameters estimated from the ACT power spectra. We also present a combined map based on ACT and WMAP data that has high signal-to-noise over a wide range of multipoles.
△ Less
Submitted 3 September, 2010;
originally announced September 2010.
-
The Atacama Cosmology Telescope: Extragalactic Sources at 148 GHz in the 2008 Survey
Authors:
T. A. Marriage,
J. B. Juin,
Y. -T. Lin,
D. Marsden,
M. R. Nolta,
B. Partridge,
P. A. R. Ade,
P. Aguirre,
M. Amiri,
J. W. Appel,
L. F. Barrientos,
E. S. Battistelli,
J. R. Bond,
B. Brown,
B. Burger,
J. Chervenak,
S. Das,
M. J. Devlin,
S. R. Dicker,
W. B. Doriese,
J. Dunkley,
R. Dunner,
T. Essinger-Hileman,
R. P. Fisher,
J. W. Fowler
, et al. (44 additional authors not shown)
Abstract:
We report on extragalactic sources detected in a 455 square-degree map of the southern sky made with data at a frequency of 148 GHz from the Atacama Cosmology Telescope 2008 observing season. We provide a catalog of 157 sources with flux densities spanning two orders of magnitude: from 15 to 1500 mJy. Comparison to other catalogs shows that 98% of the ACT detections correspond to sources detected…
▽ More
We report on extragalactic sources detected in a 455 square-degree map of the southern sky made with data at a frequency of 148 GHz from the Atacama Cosmology Telescope 2008 observing season. We provide a catalog of 157 sources with flux densities spanning two orders of magnitude: from 15 to 1500 mJy. Comparison to other catalogs shows that 98% of the ACT detections correspond to sources detected at lower radio frequencies. Three of the sources appear to be associated with the brightest cluster galaxies of low redshift X-ray selected galaxy clusters. Estimates of the radio to mm-wave spectral indices and differential counts of the sources further bolster the hypothesis that they are nearly all radio sources, and that their emission is not dominated by re-emission from warm dust. In a bright (>50 mJy) 148 GHz-selected sample with complete cross-identifications from the Australia Telescope 20 GHz survey, we observe an average steepening of the spectra between 5, 20, and 148 GHz with median spectral indices of $α_{\rm 5-20} = -0.07 \pm 0.06$, $α_{\rm 20-148} = -0.39 \pm0.04$, and $α_{\rm 5-148} = -0.20 \pm 0.03$. When the measured spectral indices are taken into account, the 148 GHz differential source counts are consistent with previous measurements at 30 GHz in the context of a source count model dominated by radio sources. Extrapolating with an appropriately rescaled model for the radio source counts, the Poisson contribution to the spatial power spectrum from synchrotron-dominated sources with flux density less than 20 mJy is $C^{\rm Sync} = (2.8 \pm 0.3) \times 10^{-6} \micro\kelvin^2$.
△ Less
Submitted 3 June, 2011; v1 submitted 29 July, 2010;
originally announced July 2010.
-
The Atacama Cosmology Telescope: The Receiver and Instrumentation
Authors:
D. S. Swetz,
P. A. R. Ade,
M. Amiri,
J. W. Appel,
E. S. Battistelli,
B. Burger,
J. Chervenak,
M. J. Devlin,
S. R. Dicker,
W. B. Doriese,
R. Dünner,
T. Essinger-Hileman,
R. P. Fisher,
J. W. Fowler,
M. Halpern,
M. Hasselfield,
G. C. Hilton,
A. D. Hincks,
K. D. Irwin,
N. Jarosik,
M. Kaul,
J. Klein,
J. M. Lau,
M. Limon,
T. A. Marriage
, et al. (16 additional authors not shown)
Abstract:
The Atacama Cosmology Telescope was designed to measure small-scale anisotropies in the Cosmic Microwave Background and detect galaxy clusters through the Sunyaev-Zel'dovich effect. The instrument is located on Cerro Toco in the Atacama Desert, at an altitude of 5190 meters. A six-meter off-axis Gregorian telescope feeds a new type of cryogenic receiver, the Millimeter Bolometer Array Camera. The…
▽ More
The Atacama Cosmology Telescope was designed to measure small-scale anisotropies in the Cosmic Microwave Background and detect galaxy clusters through the Sunyaev-Zel'dovich effect. The instrument is located on Cerro Toco in the Atacama Desert, at an altitude of 5190 meters. A six-meter off-axis Gregorian telescope feeds a new type of cryogenic receiver, the Millimeter Bolometer Array Camera. The receiver features three 1000-element arrays of transition-edge sensor bolometers for observations at 148 GHz, 218 GHz, and 277 GHz. Each detector array is fed by free space mm-wave optics. Each frequency band has a field of view of approximately 22' x 26'. The telescope was commissioned in 2007 and has completed its third year of operations. We discuss the major components of the telescope, camera, and related systems, and summarize the instrument performance.
△ Less
Submitted 2 July, 2010;
originally announced July 2010.