Undulator-Based Production of Polarized Positrons
Authors:
Gideon Alexander,
John Barley,
Yuri Batygin,
Steven Berridge,
Vinod Bharadwaj,
Gary Bower,
William Bugg,
Franz-Josef Decker,
Ralph Dollan,
Yuri Efremenko,
Klaus Floettmann,
Vahagn Gharibyan,
Carsten Hast,
Richard Iverson,
Hermann Kolanoski,
Jan W. Kovermann,
Karim Laihem,
Thomas Lohse,
Kirk T. McDonald,
Alexander A. Mikhailichenko,
Gudrid Moortgat-Pick,
Philipp Pahl,
Rainer Pitthan,
Roman Poeschl,
Erez Reinherz-Aronis
, et al. (10 additional authors not shown)
Abstract:
Full exploitation of the physics potential of a future International Linear Collider will require the use of polarized electron and positron beams. Experiment E166 at the Stanford Linear Accelerator Center (SLAC) has demonstrated a scheme in which an electron beam passes through a helical undulator to generate photons (whose first-harmonic spectrum extended to 7.9MeV) with circular polarization,…
▽ More
Full exploitation of the physics potential of a future International Linear Collider will require the use of polarized electron and positron beams. Experiment E166 at the Stanford Linear Accelerator Center (SLAC) has demonstrated a scheme in which an electron beam passes through a helical undulator to generate photons (whose first-harmonic spectrum extended to 7.9MeV) with circular polarization, which are then converted in a thin target to generate longitudinally polarized positrons and electrons. The experiment was carried out with a one-meter-long, 400-period, pulsed helical undulator in the Final Focus Test Beam (FFTB) operated at 46.6GeV. Measurements of the positron polarization have been performed at five positron energies from 4.5 to 7.5MeV. In addition, the electron polarization has been determined at 6.7MeV, and the effect of operating the undulator with a ferrofluid was also investigated. To compare the measurements with expectations, detailed simulations were made with an upgraded version of Geant4 that includes the dominant polarization-dependent interactions of electrons, positrons, and photons with matter. The measurements agree with calculations, corresponding to 80% polarization for positrons near 6MeV and 90% for electrons near 7MeV.
△ Less
Submitted 19 May, 2009;
originally announced May 2009.
Monte Carlo based studies of a polarized positron source for International Linear Collider (ILC)
Authors:
Ralph Dollan,
Karim Laihem,
Andreas Schaelicke
Abstract:
The full exploitation of the physics potential of an International Linear Collider (ILC) requires the development of a polarized positron beam. New concepts of polarized positron sources are based on the development of circularly polarized photon sources. The polarized photons create electron-positron pairs in a thin target and transfer their polarization state to the outgoing leptons. To achiev…
▽ More
The full exploitation of the physics potential of an International Linear Collider (ILC) requires the development of a polarized positron beam. New concepts of polarized positron sources are based on the development of circularly polarized photon sources. The polarized photons create electron-positron pairs in a thin target and transfer their polarization state to the outgoing leptons. To achieve a high level of positron polarization the understanding of the production mechanisms in the target is crucial. Therefore a general framework for the simulation of polarized processes with GEANT4 is under development. In this contribution the current status of the project and its application to a study of the positron production process for the ILC is presented.
△ Less
Submitted 21 December, 2005;
originally announced December 2005.
Beam Calorimeter Technologies
Authors:
R. Dollan,
Ch. Grah,
E. Kuznetsova,
W. Lange,
W. Lohmann,
A. Stahl,
K. Afanaciev,
V. Drugakov,
I. Emeliantchik
Abstract:
Two different technologies are considered for the Beam Calorimeters of the ILC detector. Simulation studies of the performance have been done for a diamond-tungsten sandwich calorimeter and for a homogeneous heavy element crystal calorimeter with optical fiber readout. Studies of the stability and the linearity of a polycrystalline diamond were done for the diamond-tungsten option. For the heavy…
▽ More
Two different technologies are considered for the Beam Calorimeters of the ILC detector. Simulation studies of the performance have been done for a diamond-tungsten sandwich calorimeter and for a homogeneous heavy element crystal calorimeter with optical fiber readout. Studies of the stability and the linearity of a polycrystalline diamond were done for the diamond-tungsten option. For the heavy crystal option the light yield reduction due to the wavelength shifting fiber readout was studied.
△ Less
Submitted 25 July, 2005; v1 submitted 1 July, 2005;
originally announced July 2005.