-
Focusing of an Atomic Beam
Authors:
R. Bruce Doak
Abstract:
A bent-crystal mirror has been used to focus an atomic helium beam. The mirror is made from gold deposited onto a mica substrate to form a thin film (~5000 Å thick) of large single crystal domains (domain size ~4000 Å ). The mica sheet is then bent in situ to form a cylindrical mirror of variable radius of curvature. Measurement of scattered beam intensity and angular distribution as a function of…
▽ More
A bent-crystal mirror has been used to focus an atomic helium beam. The mirror is made from gold deposited onto a mica substrate to form a thin film (~5000 Å thick) of large single crystal domains (domain size ~4000 Å ). The mica sheet is then bent in situ to form a cylindrical mirror of variable radius of curvature. Measurement of scattered beam intensity and angular distribution as a function of curvature demonstrate excellent focusing to within the mosaic spread of the surface. The reflectivity of the room temperature mirror is about ten percent. Potential uses are discussed, ranging from immediate applications in intensity and resolution enhancement of helium scattering experiments, to such long term possibilities as hyper-cooling of the beam or fabrication of a scanning atom microscope.
△ Less
Submitted 16 January, 2022;
originally announced January 2022.
-
Three-dimensional view of ultrafast dynamics in photoexcited bacteriorhodopsin
Authors:
Gabriela Nass Kovacs,
Jacques-Philippe Colletier,
Marie Grünbein,
Yang Yang,
Till Stensitzki,
Alexander Batyuk,
Sergio Carbajo,
R Doak,
David Ehrenberg,
Lutz Foucar,
Raphael Gasper,
Alexander Gorel,
Mario Hilpert,
Marco Kloos,
Jason Koglin,
Jochen Reinstein,
Christopher Roome,
Ramona Schlesinger,
Matthew Seaberg,
Robert Shoeman,
Miriam Stricker,
Sébastien Boutet,
Stefan Haacke,
Joachim Heberle,
Karsten Heyne
, et al. (3 additional authors not shown)
Abstract:
Bacteriorhodopsin (bR) is a light-driven proton pump. We use time-resolved crystallography at an X-ray free-electron laser to follow the structural changes in multiphoton-excited bR from 250 femtoseconds to 10 picoseconds. Quantum chemistry and ultrafast spectroscopy allow identifying a sequential two-photon absorption process, leading to excitation of a tryptophan residue flanking the retinal chr…
▽ More
Bacteriorhodopsin (bR) is a light-driven proton pump. We use time-resolved crystallography at an X-ray free-electron laser to follow the structural changes in multiphoton-excited bR from 250 femtoseconds to 10 picoseconds. Quantum chemistry and ultrafast spectroscopy allow identifying a sequential two-photon absorption process, leading to excitation of a tryptophan residue flanking the retinal chromophore, as a first manifestation of multi-photon effects. We resolve distinct stages in the structural dynamics of the all-trans retinal in photoexcited bR to a highly twisted 13-cis conformation. Other active site sub-picosecond rearrangements include correlated vibrational motions of the electronically excited retinal chromophore, the surrounding amino acids and water molecules as well as their hydrogen bonding network. These results show that this extended photo-active network forms an electronically and vibrationally coupled system in bR, and most likely in all retinal proteins.
△ Less
Submitted 22 May, 2019;
originally announced May 2019.
-
A pump-probe XFEL particle injector for hydrated samples
Authors:
U. Weierstall,
R. B. Doak,
J. C. H. Spence
Abstract:
We have developed a liquid jet injector system that can be used for hydrated sample delivery at X-ray Free Electron Laser (XFEL) sources and 3rd generation synchrotron sources. The injector is based on the Gas Dynamic Virtual Nozzle (GDVN), which generates a liquid jet with diameter ranging from 300 nm to 20 μm without the clogging problems associated with conventional Rayleigh jets. An improved n…
▽ More
We have developed a liquid jet injector system that can be used for hydrated sample delivery at X-ray Free Electron Laser (XFEL) sources and 3rd generation synchrotron sources. The injector is based on the Gas Dynamic Virtual Nozzle (GDVN), which generates a liquid jet with diameter ranging from 300 nm to 20 μm without the clogging problems associated with conventional Rayleigh jets. An improved nozzle design is presented here. A differential pum** system protects the vacuum chamber and an in-vacuum microscope allows observation of the liquid jet for diagnostics while it is being exposed to the X-ray beam. A fiber optically coupled pump laser illuminating the jet is incorporated for pump-probe experiments. First results with this injector system have been obtained at the LCLS.
△ Less
Submitted 11 May, 2011;
originally announced May 2011.
-
Tomographic femtosecond X-ray diffractive imaging
Authors:
K. E. Schmidt,
J. C. H. Spence,
U. Weierstall,
R. Kirian,
X. Wang,
D. Starodub,
H. N. Chapman,
M. R. Howells,
R. B. Doak
Abstract:
A method is proposed for obtaining three simultaneous projections of a target from a single radiation pulse, which also allows the relative orientation of successive targets to be determined. The method has application to femtosecond X-ray diffraction, and does not require solution of the phase problem. We show that the principle axes of a compact charge-density distribution can be obtained from…
▽ More
A method is proposed for obtaining three simultaneous projections of a target from a single radiation pulse, which also allows the relative orientation of successive targets to be determined. The method has application to femtosecond X-ray diffraction, and does not require solution of the phase problem. We show that the principle axes of a compact charge-density distribution can be obtained from projections of its autocorrelation function, which is directly accessible in diffraction experiments. The results may have more general application to time resolved tomographic pump-probe experiments and time-series imaging.
△ Less
Submitted 27 May, 2009; v1 submitted 9 June, 2008;
originally announced June 2008.
-
Gas Dynamic Virtual Nozzle for Generation of Microscopic Droplet Streams
Authors:
D. P. DePonte,
U. Weierstall,
D. Starodub,
K. Schmidt,
J. C. H. Spence,
R. B. Doak
Abstract:
As shown by Ganan-Calvo and co-workers, a free liquid jet can be compressed in iameter through gas-dynamic forces exerted by a co-flowing gas, obviating the need for a solid nozzle to form a microscopic liquid jet and thereby alleviating the clogging problems that plague conventional droplet sources of small diameter. We describe in this paper a novel form of droplet beam source based on this pr…
▽ More
As shown by Ganan-Calvo and co-workers, a free liquid jet can be compressed in iameter through gas-dynamic forces exerted by a co-flowing gas, obviating the need for a solid nozzle to form a microscopic liquid jet and thereby alleviating the clogging problems that plague conventional droplet sources of small diameter. We describe in this paper a novel form of droplet beam source based on this principle. The source is miniature, robust, dependable, easily fabricated, and eminently suitable for delivery of microscopic liquid droplets, including hydrated biological samples, into vacuum for analysis using vacuum instrumentation. Monodisperse, single file droplet streams are generated by triggering the device with a piezoelectric actuator. The device is essentially immune to clogging.
△ Less
Submitted 28 March, 2008;
originally announced March 2008.
-
X-Ray Powder Diffraction from Sub-Micron Crystals of Photosystem-1 Membrane Protein
Authors:
D. A. Shapiro,
D. DePonte,
R. B. Doak,
P. Fromme,
G. Hembree,
M. Hunter,
S. Marchesini,
K. Schmidt,
D. Starodub,
U. Weierstall,
H. Chapman,
J. Spence
Abstract:
We demonstrate that powder diffraction data can be collected from sub-micron crystals of a mbrane protein with nearly two orders of magnitude more atoms than the molecules commonly used for powder diffraction. The crystals of photosystem-1 protein were size-selected using a 500 nm pore- size filter and delivered to a soft x-ray beam with a photon energy of 1.5 keV using a dynamically focused mic…
▽ More
We demonstrate that powder diffraction data can be collected from sub-micron crystals of a mbrane protein with nearly two orders of magnitude more atoms than the molecules commonly used for powder diffraction. The crystals of photosystem-1 protein were size-selected using a 500 nm pore- size filter and delivered to a soft x-ray beam with a photon energy of 1.5 keV using a dynamically focused micro-jet developed for the serial crystallography experiment at beamline 9.0.1. The 10-micron jet places many such randomly oriented crystals in the x-ray beam simultaneously resulting in a powder diffraction pattern which extends to 28 angstrom resolution with just 200 seconds of x-ray exposure. The use of the jet for particle delivery allows for a thin sample, appropriate for the soft x-rays used, and continuously refreshes the crystals so that radiation damage is not possible. The small size of the crystals requires the use of lower energy photons for increased scattering strength and increased spacing between powder rings. The powder patterns obtained in this way, from abundant nano-crystals, could be used to provide low resolution molecular envelopes if phased using techniques such as compressive sensing which do not require atomic resolution data. The results also serve to test our aerojet injector system, with future application to femtosecond diffraction in Free Electron X-ray Laser schemes, and for Serial Crystallography using a single-file beam of aligned hydrated molecules.
△ Less
Submitted 25 September, 2008; v1 submitted 27 March, 2008;
originally announced March 2008.
-
Dose, exposure time, and resolution in Serial X-ray Crystallography
Authors:
D. Starodub,
P. Rez,
G. Hembree,
M. Howells,
D. Shapiro,
H. N. Chapman,
P. Fromme,
K. Schmidt,
U. Weierstall,
R. B. Doak,
J. C. H. Spence
Abstract:
The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the a…
▽ More
The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function following iterative solution of the phase problem, and reconstruction of an electron density map in the projection approximation. These calculations include counting shot noise and multiple starts of the phasing algorithm. The results indicate counting time and the number of proteins needed within the beam at any instant for a given resolution and X-ray flux. We confirm an inverse fourth power dependence of exposure time on resolution, with important implications for all coherent X-ray imaging. We find that multiple single-file protein beams will be needed for sub-nanometer resolution on current third generation synchrotrons, but not on fourth generation designs, where reconstruction of secondary protein structure at a resolution of 0.7 nm should be possible with short exposures.
△ Less
Submitted 22 June, 2007;
originally announced June 2007.
-
Droplet beams for serial crystallography of proteins
Authors:
U. Weierstall,
R. B. Doak,
J. C. H. Spence,
D. Starodub,
D. Shapiro,
P. Kennedy,
J. Warner,
G. G. Hembree,
P. Fromme,
H. Chapman
Abstract:
Serial diffraction of proteins requires an injection method to deliver protein molecules - preferably uncharged, fully hydrated, spatially oriented, and with high flux - into the crossed beams of an alignment laser and a focused probe beam of electrons or X-rays of typically only a few tens of microns diameter. The aim of this work has been to examine several potential droplet sources as to thei…
▽ More
Serial diffraction of proteins requires an injection method to deliver protein molecules - preferably uncharged, fully hydrated, spatially oriented, and with high flux - into the crossed beams of an alignment laser and a focused probe beam of electrons or X-rays of typically only a few tens of microns diameter. The aim of this work has been to examine several potential droplet sources as to their suitability for this task. We compare Rayleigh droplet sources, electrospray sources, nebulizers and aerojet-focused droplet sources using time-resolved optical images of the droplet beams. Shrinkage of droplets by evaporation as a means of removing most of the water surrounding the proteins is discussed. Experimental measurements of droplet size, conformation of proteins after passing through a Rayleigh jet, and triboelectric charging are presented and conclusions are drawn about the source configuration for serial diffraction. First experimental X-ray diffraction patterns from Rayleigh droplet beams doped with 100nm gold balls are shown.
△ Less
Submitted 11 January, 2007;
originally announced January 2007.
-
Surface Phonons and Other Localized Excitations
Authors:
Philip B. Allen,
Seth Aubin,
R. B. Doak
Abstract:
The diatomic linear chain of masses coupled by harmonic springs is a textboook model for vibrational normal modes (phonons) in crystals. In addition to propagating acoustic and optic branches, this model is known to support a ``gap mode'' localized at the surface, provided the atom at the surface has light rather than heavy mass. An elementary argument is given which explains this mode and provi…
▽ More
The diatomic linear chain of masses coupled by harmonic springs is a textboook model for vibrational normal modes (phonons) in crystals. In addition to propagating acoustic and optic branches, this model is known to support a ``gap mode'' localized at the surface, provided the atom at the surface has light rather than heavy mass. An elementary argument is given which explains this mode and provides values for the frequency and localization length. By reinterpreting this mode in different ways, we obtain the frequency and localization lengths for three other interesting modes: (1) the surface vibrational mode of a light mass impurity at the surface of a monatomic chain; (2) the localized vibrational mode of a stacking fault in a diatomic chain; and (3) the localized vibrational mode of a light mass impurity in a monatomic chain.
△ Less
Submitted 13 August, 1999;
originally announced August 1999.