-
An apparatus to manipulate and identify individual Ba ions from bulk liquid Xe
Authors:
K. Twelker,
S. Kravitz,
M. Montero Díez,
G. Gratta,
W. Fairbank Jr.,
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
D. Beck,
C. Benitez-Medina,
M. Breidenbach,
T. Brunner,
G. F. Cao,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
S. J. Daugherty,
C. G. Davis,
R. DeVoe,
S. Delaquis,
T. Didberidze,
J. Dilling,
M. J. Dolinski
, et al. (55 additional authors not shown)
Abstract:
We describe a system to transport and identify barium ions produced in liquid xenon, as part of R&D towards the second phase of a double beta decay experiment, nEXO. The goal is to identify the Ba ion resulting from an extremely rare nuclear decay of the isotope $^{136}$Xe, hence providing a confirmation of the occurrence of the decay. This is achieved through Resonance Ionization Spectroscopy (RI…
▽ More
We describe a system to transport and identify barium ions produced in liquid xenon, as part of R&D towards the second phase of a double beta decay experiment, nEXO. The goal is to identify the Ba ion resulting from an extremely rare nuclear decay of the isotope $^{136}$Xe, hence providing a confirmation of the occurrence of the decay. This is achieved through Resonance Ionization Spectroscopy (RIS). In the test setup described here, Ba ions can be produced in liquid xenon or vacuum and collected on a clean substrate. This substrate is then removed to an analysis chamber under vacuum, where laser-induced thermal desorption and RIS are used with time-of-flight (TOF) mass spectroscopy for positive identification of the barium decay product.
△ Less
Submitted 22 March, 2017; v1 submitted 2 July, 2014;
originally announced July 2014.
-
An improved measurement of the 2νββ half-life of Xe-136 with EXO-200
Authors:
J. B. Albert,
M. Auger,
D. J. Auty,
P. S. Barbeau,
E. Beauchamp,
D. Beck,
V. Belov,
C. Benitez-Medina,
J. Bonatt,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
J. Chaves,
B. Cleveland,
S. Cook,
T. Daniels,
M. Danilov,
S. J. Daugherty,
C. G. Davis,
J. Davis,
S. Delaquis,
R. DeVoe,
A. Dobi
, et al. (72 additional authors not shown)
Abstract:
We report on an improved measurement of the 2νββ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those…
▽ More
We report on an improved measurement of the 2νββ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those directly related to the present measurement. The Xe-136 2νββ half-life is found to be 2.165 +- 0.016 (stat) +- 0.059 (sys) x 10^21 years. This is the most precisely measured half-life of any 2νββ decay to date.
△ Less
Submitted 29 January, 2014; v1 submitted 25 June, 2013;
originally announced June 2013.
-
Search for Neutrinoless Double-Beta Decay in $^{136}$Xe with EXO-200
Authors:
M. Auger,
D. J. Auty,
P. S. Barbeau,
E. Beauchamp,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
T. Brunner,
A. Burenkov,
B. Cleveland,
S. Cook,
T. Daniels,
M. Danilov,
C. G. Davis,
S. Delaquis,
R. deVoe,
A. Dobi,
M. J. Dolinski,
A. Dolgolenko,
M. Dunford,
W. Fairbank Jr.,
J. Farine,
W. Feldmeier,
P. Fierlinger,
D. Franco
, et al. (53 additional authors not shown)
Abstract:
We report on a search for neutrinoless double-beta decay of $^{136}$Xe with EXO-200. No signal is observed for an exposure of 32.5 kg-yr, with a background of ~1.5 x 10^{-3} /(kg yr keV) in the $\pm 1σ$ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay $T_{1/2}^{0νββ}$($^{136}$Xe) > 1.6 x 10$^{25}$ yr (90% CL), corresponding to effective Majorana ma…
▽ More
We report on a search for neutrinoless double-beta decay of $^{136}$Xe with EXO-200. No signal is observed for an exposure of 32.5 kg-yr, with a background of ~1.5 x 10^{-3} /(kg yr keV) in the $\pm 1σ$ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay $T_{1/2}^{0νββ}$($^{136}$Xe) > 1.6 x 10$^{25}$ yr (90% CL), corresponding to effective Majorana masses of less than 140-380 meV, depending on the matrix element calculation.
△ Less
Submitted 20 July, 2012; v1 submitted 24 May, 2012;
originally announced May 2012.
-
The EXO-200 detector, part I: Detector design and construction
Authors:
M. Auger,
D. J. Auty,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
E. Beauchamp,
C. Benitez-Medina,
M. Breidenbach,
D. Chauhan,
B. Cleveland,
R. Conley,
J. Cook,
S. Cook,
A. Coppens,
W. Craddock,
T. Daniels,
C. G. Davis,
J. Davis,
R. deVoe,
A. Dobi,
M. J. Dolinski,
M. Dunford,
W. Fairbank Jr,
J. Farine,
P. Fierlinger
, et al. (56 additional authors not shown)
Abstract:
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most…
▽ More
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most innovative aspects of the design that revolve around the reduction of backgrounds, the efficient use of the expensive isotopically enriched xenon, and the optimization of the energy resolution in a relatively large volume.
△ Less
Submitted 23 May, 2012; v1 submitted 10 February, 2012;
originally announced February 2012.
-
Xenon purity analysis for EXO-200 via mass spectrometry
Authors:
A. Dobi,
C. Hall,
S. Slutsky,
Y. -R. Yen,
B. Aharmin,
M. Auger,
P. S. Barbeau,
C. Benitez-Medina,
M. Breidenbach,
B. Cleveland,
R. Conley,
J. Cook,
S. Cook,
I. Counts,
W. Craddock,
T. Daniels,
C. G. Davis,
J. Davis,
R. deVoe,
M. Dixit,
M. J. Dolinski,
K. Donato,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger
, et al. (51 additional authors not shown)
Abstract:
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We ha…
▽ More
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We have used the technique to screen the EXO-200 xenon before, during, and after its use in our detector, and these measurements have proven useful. This is the first application of the cold trap mass spectrometry technique to an operating physics experiment.
△ Less
Submitted 5 September, 2011;
originally announced September 2011.
-
Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200
Authors:
N. Ackerman,
B. Aharmim,
M. Auger,
D. J. Auty,
P. S. Barbeau,
K. Barry,
L. Bartoszek,
E. Beauchamp,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
B. Cleveland,
R. Conley,
E. Conti,
J. Cook,
S. Cook,
A. Coppens,
I. Counts,
W. Craddock,
T. Daniels,
M. V. Danilov,
C. G. Davis,
J. Davis,
R. deVoe
, et al. (78 additional authors not shown)
Abstract:
We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, th…
▽ More
We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.
△ Less
Submitted 22 November, 2011; v1 submitted 21 August, 2011;
originally announced August 2011.
-
A xenon gas purity monitor for EXO
Authors:
EXO Collaboration,
A. Dobi,
C. Hall,
S. Herrin,
A. Odian,
C. Y. Prescott,
P. C. Rowson,
N. Ackerman,
B. Aharmin,
M. Auger,
P. S. Barbeau,
K. Barry,
C. Benitez-Medina,
M. Breidenbach,
S. Cook,
I. Counts,
T. Daniels,
R. DeVoe,
M. J. Dolinski,
K. Donato,
W. Fairbank Jr.,
J. Farine,
G. Giroux,
R. Gornea,
K. Graham
, et al. (35 additional authors not shown)
Abstract:
We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas pressure of one atmosphere or more. The theory of operation of the GPM is discussed along with the interactions of oxygen and other impurities with the GPM's tu…
▽ More
We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas pressure of one atmosphere or more. The theory of operation of the GPM is discussed along with the interactions of oxygen and other impurities with the GPM's tungsten filament. Lab tests and experiences in commissioning the EXO-200 double beta decay experiment are described. These devices can also be used on other noble gases.
△ Less
Submitted 9 June, 2011;
originally announced June 2011.
-
A magnetically-driven piston pump for ultra-clean applications
Authors:
F. LePort,
R. Neilson,
P. S. Barbeau,
K. Barry,
L. Bartoszek,
I. Counts,
J. Davis,
R. deVoe,
M. J. Dolinski,
G. Gratta,
M. Green,
M. Montero Díez,
A. R. Müller,
K. O'Sullivan,
A. Rivas,
K. Twelker,
B. Aharmim,
M. Auger,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
B. Cleveland,
R. Conley,
J. Cook
, et al. (55 additional authors not shown)
Abstract:
A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pum** more than 16 standard liters per minute (SL…
▽ More
A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pum** more than 16 standard liters per minute (SLPM) of xenon gas with 750 torr differential pressure.
△ Less
Submitted 26 April, 2011;
originally announced April 2011.
-
A simple radionuclide-driven single-ion source
Authors:
M. Montero Díez,
K. Twelker,
W. Fairbank Jr.,
G. Gratta,
P. S. Barbeau,
K. Barry,
R. DeVoe,
M. J. Dolinski,
M. Green,
F. LePort,
A. R. Müller,
R. Neilson,
K. O'Sullivan,
N. Ackerman,
B. Aharmin,
M. Auger,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
S. Cook,
T. Daniels,
K. Donato,
J. Farine,
G. Giroux,
R. Gornea
, et al. (32 additional authors not shown)
Abstract:
We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon α-particle detector and vapor depositing a layer of BaF2 over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+ ions from the BaF2 layer and emit them in the surrounding environment. The simultaneous detect…
▽ More
We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon α-particle detector and vapor depositing a layer of BaF2 over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+ ions from the BaF2 layer and emit them in the surrounding environment. The simultaneous detection of an α particle in the substrate detector allows for tagging of the nuclear decay and of the Ba+ emission. The source is simple, durable, and can be manipulated and used in different environments. We discuss the fabrication process, which can be easily adapted to emit most other chemical species, and the performance of the source.
△ Less
Submitted 19 August, 2010;
originally announced August 2010.
-
Characterization of large area APDs for the EXO-200 detector
Authors:
R. Neilson,
F. LePort,
A. Pocar,
K. Kumar,
A. Odian,
C. Y. Prescott,
V. Tenev,
N. Ackerman,
D. Akimov,
M. Auger,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
R. Conley,
S. Cook,
R. deVoe,
M. J. Dolinski,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger,
B. Flatt,
R. Gornea,
G. Gratta,
M. Green,
C. Hall
, et al. (27 additional authors not shown)
Abstract:
EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more tha…
▽ More
EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more than 800 LAAPDs for selective installation in the EXO-200 detector.
△ Less
Submitted 13 June, 2009;
originally announced June 2009.
-
Systematic study of trace radioactive impurities in candidate construction materials for EXO-200
Authors:
D. S. Leonard,
P. Grinberg,
P. Weber,
E. Baussan,
Z. Djurcic,
G. Keefer,
A. Piepke,
A. Pocar,
J. -L. Vuilleumier,
J. -M. Vuilleumier,
D. Akimov,
A. Bellerive,
M. Bowcock,
M. Breidenbach,
A. Burenkov,
R. Conley,
W. Craddock,
M. Danilov,
R. DeVoe,
M. Dixit,
A. Dolgolenko,
I. Ekchtout,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger
, et al. (32 additional authors not shown)
Abstract:
The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma…
▽ More
The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma counting, alpha counting, neutron activation analysis, and high-sensitivity mass spectrometry.
△ Less
Submitted 4 August, 2008; v1 submitted 28 September, 2007;
originally announced September 2007.
-
A microfabricated sensor for thin dielectric layers
Authors:
P. Fierlinger,
R. DeVoe,
B. Flatt,
G. Gratta,
M. Green,
S. Kolkowitz,
F. Leport,
M. Montero Diez,
R. Neilson,
K. O'Sullivan,
A. Pocar,
J. Wodin
Abstract:
We describe a sensor for the measurement of thin dielectric layers capable of operation in a variety of environments. The sensor is obtained by microfabricating a capacitor with interleaved aluminum fingers, exposed to the dielectric to be measured. In particular, the device can measure thin layers of solid frozen from a liquid or gaseous medium. Sensitivity to single atomic layers is achievable…
▽ More
We describe a sensor for the measurement of thin dielectric layers capable of operation in a variety of environments. The sensor is obtained by microfabricating a capacitor with interleaved aluminum fingers, exposed to the dielectric to be measured. In particular, the device can measure thin layers of solid frozen from a liquid or gaseous medium. Sensitivity to single atomic layers is achievable in many configurations and, by utilizing fast, high sensitivity capacitance read out in a feedback system onto environmental parameters, coatings of few layers can be dynamically maintained. We discuss the design, read out and calibration of several versions of the device optimized in different ways. We specifically dwell on the case in which atomically thin solid xenon layers are grown and stabilized, in cryogenic conditions, from a liquid xenon bath.
△ Less
Submitted 24 March, 2008; v1 submitted 4 June, 2007;
originally announced June 2007.
-
A linear RFQ ion trap for the Enriched Xenon Observatory
Authors:
B. Flatt,
M. Green,
J. Wodin,
R. DeVoe,
P. Fierlinger,
G. Gratta,
F. LePort,
M. Montero Diez,
R. Neilson,
K. OSullivan,
A. Pocar,
S. Waldman,
E. Baussan,
M. Breidenbach,
R. Conley,
W. Fairbank Jr.,
J. Farine,
C. Hall,
K. Hall,
D. Hallman,
C. Hargrove,
M. Hauger,
J. Hodgson,
F. Juget,
D. S. Leonard
, et al. (17 additional authors not shown)
Abstract:
The design, construction, and performance of a linear radio-frequency ion trap (RFQ) intended for use in the Enriched Xenon Observatory (EXO) are described. EXO aims to detect the neutrinoless double-beta decay of $^{136}$Xe to $^{136}$Ba. To suppress possible backgrounds EXO will complement the measurement of decay energy and, to some extent, topology of candidate events in a Xe filled detector…
▽ More
The design, construction, and performance of a linear radio-frequency ion trap (RFQ) intended for use in the Enriched Xenon Observatory (EXO) are described. EXO aims to detect the neutrinoless double-beta decay of $^{136}$Xe to $^{136}$Ba. To suppress possible backgrounds EXO will complement the measurement of decay energy and, to some extent, topology of candidate events in a Xe filled detector with the identification of the daughter nucleus ($^{136}$Ba). The ion trap described here is capable of accepting, cooling, and confining individual Ba ions extracted from the site of the candidate double-beta decay event. A single trapped ion can then be identified, with a large signal-to-noise ratio, via laser spectroscopy.
△ Less
Submitted 12 April, 2007;
originally announced April 2007.
-
Observation of single collisionally cooled trapped ions in a buffer gas
Authors:
M. Green,
J. Wodin,
R. DeVoe,
P. Fierlinger,
B. Flatt,
G. Gratta,
F. LePort,
M. Montero Diez,
R. Neilson,
K. OSullivan,
A. Pocar,
S. Waldman,
D. S. Leonard,
A. Piepke,
C. Hargrove,
D. Sinclair,
V. Strickland,
W. Fairbank Jr.,
K. Hall,
B. Mong,
M. Moe,
J. Farine,
D. Hallman,
C. Virtue,
E. Baussan
, et al. (15 additional authors not shown)
Abstract:
Individual Ba ions are trapped in a gas-filled linear ion trap and observed with a high signal-to-noise ratio by resonance fluorescence. Single-ion storage times of ~5 min (~1 min) are achieved using He (Ar) as a buffer gas at pressures in the range 8e-5 - 4e-3 torr. Trap dynamics in buffer gases are experimentally studied in the simple case of single ions. In particular, the cooling effects of…
▽ More
Individual Ba ions are trapped in a gas-filled linear ion trap and observed with a high signal-to-noise ratio by resonance fluorescence. Single-ion storage times of ~5 min (~1 min) are achieved using He (Ar) as a buffer gas at pressures in the range 8e-5 - 4e-3 torr. Trap dynamics in buffer gases are experimentally studied in the simple case of single ions. In particular, the cooling effects of light gases such as He and Ar and the destabilizing properties of heavier gases such as Xe are studied. A simple model is offered to explain the observed phenomenology.
△ Less
Submitted 5 July, 2007; v1 submitted 14 February, 2007;
originally announced February 2007.
-
A liquid xenon ionization chamber in an all-fluoropolymer vessel
Authors:
EXO Collaboration,
F. LePort,
A. Pocar,
L. Bartoszek,
R. DeVoe,
P. Fierlinger,
B. Flatt,
G. Gratta,
M. Green,
T. Koffas,
M. Montero Diez,
R. Neilson,
K. O'Sullivan,
S. Waldman,
J. Wodin,
D. Woisard,
E. Baussan,
M. Breidenbach,
R. Conley,
W. Fairbank Jr.,
J. Farine,
C. Hall,
K. Hall,
D. Hallman,
C. Hargrove
, et al. (20 additional authors not shown)
Abstract:
A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low radioactivity contamination, provide some details of the construction techniques, and show the energy resolution achieved with a prototype all-fluoropolymer ionization detector.
A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low radioactivity contamination, provide some details of the construction techniques, and show the energy resolution achieved with a prototype all-fluoropolymer ionization detector.
△ Less
Submitted 19 November, 2006;
originally announced November 2006.